SURFACE FINISH. A galvanized finish is MnDOT s standard on new traffic control signal poles, mast arms, transformer bases, and luminaire extensions.

Similar documents
REQUEST FOR PROPOSALS

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION. SPECIFICATIONS FOR Interior Painting CONTRACT

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

CHAPTER 29 PROJECT COMPLETION DOCUMENTS

Painting Safety Procedure

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

1. Labels: Do not paint over UL, FMG, or other code-required labels or equipment name, identification, performance rating, or nomenclature plates.

A. Section includes surface preparation and the application of paint systems on exterior substrates.

SECTION 025 INDUSTRIAL PAINTING

Bid No :01 Exterior Roynon Elementary & La Verne Heights (Alternate #1) SCOPE OF WORK

CHAPTER 28 ACTIVATING/DEACTIVATING A SIGNAL

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

SIGNALS AND LIGHTING FIELD GUIDE

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.

B. Samples: For each exposed product and for each color and texture specified.

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION METAL FABRICATIONS

APPLICATION NOTE - SR001. Cold Weather Application

SECTION PAINTING

Tapecoat. Application Guideline

How to use a Touch Up Bottle & Brush

FABRICATING ARBOR. koroseal.com/arbor Arbor Veneered Components

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

SECTION EXTERIOR PAINTING PART 1 - GENERAL

Square Straight Steel - 4 Bolt Base Light Poles


SPECIAL SPECIFICATION Inch LED Traffic Signal Lamp Unit

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel and iron.

Storage and Installation of welded LL Hollow Metal Door Frames in Steel Studs

SECTION BULLET- RESISTANT DOORS

UNIT 11: PAINTING, STAINING, AND FINISHING

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel.

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB

Item 550 Chain Link Fence

A. Deviation from this standard must be approved by the Project Architect.

3M Scotchkote System Application Guide. High Performance Coating System for Degraded Plastisol Cladding Surfaces.

WOOD WOOD

EXTERIOR PAINTING

(H) PAINTING LIST OF BUREAU OF INDIAN STANDARD CODE OF PRACTICE (ISI)

TOOLS & SUPPLIES (Included in ProTops Tool Kit)

AquaCLAD Water-Reducible Rust Preventative Alkyd

4. Metal roof jacks at penetrations and attachments

HANDLING INSTRUCTIONS:

APPLICATION NOTE - SR001. Cold Weather Application

1.1 RELATED DOCUMENTS

Explorer Roof Rack Fitting Instructions: Roll Cage Mounted models only

Technical Data February, 2016

UNSIGNED HARDCOPY NOT CONTROLLED

Union County Vocational - Technical Schools Scotch Plains, New Jersey

INDEX TO CLAUSES PART 1 - GENERAL

SECTION 39 - MANHOLES TABLE OF CONTENTS

UPDATE REPORT 20 MONTHS AFTER TERMARUST OVERCOATING

SURFACE FINISH MAINTENANCE

SECTION PAINTS AND COATINGS. a. Section Submittal Procedures: Requirements for submittals.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION PRECAST CONCRETE STRUCTURES

Knowledge Requirements. Protective Coatings Applicator Abrasive Blast Cleaning Operator Spray Painting Operator. trainthepainter.

STANDARD SPECIFICATION FOR SHOP AND FIELD PAINTING

SUNBELT transformer WIDTFA3501 PAINTING TRANSFORMERS WITH WATERBORNE PAINT SYSTEMS INTERNAL USE ONLY DOCUMENT HISTORY

PAINTING PAINTING

MANUFACTURING INC. Specifications

LG BENIF characteristics


Handrail H Series. Product Installation. Instructions. Installation Instructions For. Wall Mounted and Freestanding Round Handrails

IGGA Guide Specification: Dowel Bar Retrofit (DBR) Introduction

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

3M Impact Protection Profile Installation System Instructions

ROOFING City of Grand Rapids Building Safety Division

Finishes and Finishing Techniques

.3 Comply with the requirements of the Manitoba Occupational Health and Safety Act and Regulations for Construction Projects.

EXCAVATION AND BACKFILL

SECTION COUNTERTOPS ecox PART 1 GENERAL

INSTALLATION MANUAL Sluice Gates, Stop-logs & Screens

BEST PRACTICES REPORT. Parks & Recreation Dept. City of Sioux Falls, SD PROJECT OVERVIEW: Industrial Customer: City of Sioux Falls Parks & Recreation

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized

Decorative Series Interior Doors

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Leaf Wetness Smart Sensor (Part # S-LWA-M003)

6400, 8400 and 9400 Series Sliding Patio Door

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Quality Marine Equipment Since Antifouling Paint For Metal Under The Waterline SPRAY. Application Instructions.

B. Related Sections: The following Sections contain requirements that relate to this Section:

Application of Air & Water Barrier Using Sprayers and Power Rollers TDS 410M

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

Application Notes! RIGID MATERIALS. Rigid material standards. Printing on Rigid Materials with the Gerber Solara ion & Gerber CAT UV

Specification Guide. Portable & Modular Buildings

SECTION MANUFACTURED CASEWORK

SPECIAL PROVISION TO SPECIAL SPECIFICATION Reflectorized Pavement Markings with Retroreflective Requirements

ROUND STEEL POLE STRAIGHT

3M Scotchkote System Application Guide. High Performance Corrosion Resistant System for Plastisol Coated Metal Cladding

Peter Krause ABN

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

C O M P A N Y C O M P A N Y

Series 9000 Vinyl Single Hung

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

Section Heavy Duty Slide Gates Tender No. [ ] Page 1

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Transcription:

A galvanized finish is MnDOT s standard on new traffic control signal poles, mast arms, transformer bases, and luminaire extensions. The galvanized finish is highly abrasion resistant, however should the galvanized finish be scratched off and the bare steel is exposed a field repair of the finish must be made. The field repair shall be as follows. A. Galvanized Pole or Mast Arm Finish Repair (2565.3Q) When the galvanized finish is damaged the repair must be in accordance with ASTM A780 Annex A2. Approved zinc rich paints can be found on MnDOT s Approved/Qualified Products List for signals. http://www.dot.state.mn.us/products/index.html 23-1

Some cities and counties require painted traffic control signal systems. If painting is required in the Contract Documents the painted poles, bases and mast arms must be pre-painted, over the galvanization at the manufacturer. See 2565.3X When painted poles or mast arms are delivered to the job site, any protective wrap provided by the manufacturer during shipping must be removed immediately (protective wrap tends to soften paint on painted poles). The collar used to erect the pole must be of such material as to ensure protection of the finish. Any damage to the finish (galvanized or paint) must be repaired as specified in the Contract Documents, to the satisfaction of the Engineer, and in accordance with the Manufacturer s recommendations. 23-2

REPAINTING EXISTING TRAFFIC CONTROL SIGNAL SYSTEMS If it is required to repaint an existing traffic control signal system refer to the Contract Documents for painting requirements. Almost all existing traffic control signal systems constructed in 1995 and earlier were painted with lead base paint which is now hazardous waste and must be removed and contained using the appropriate methods in accordance with the Contract Documents. There are very strict guidelines regarding hazardous material removal, disposal, and transportation in the Contract Documents that must be followed. Painting metallic structures and components of a traffic control signal system must conform to all the requirements in the Contract Documents. Painting metallic structures must consist of: Preparing the surface Furnishing and applying the paint Protecting and Drying the paint coatings Pedestrians, vehicles, and property must be protected against damages resulting from the painting operation and all work incidental to the painting operation. 23-3

Materials- The paint and other ingredients must conform to the specifications for the type and kind specified in the Contract Documents. The paint must be pre-mixed, ready to use, and must be delivered to the place of use in the original containers not to exceed 5 gallons in capacity. Inspection, sampling, and testing of paint must be as specified in the Contract Documents. Contents of the paint containers must not be altered unless permitted by the Engineer. Surface preparation and painting must not be started until all the materials have been inspected and approved by the Inspector. The finish paint must consist of two field coats. The paint must conform to the following requirements: Aluminum paint - moisture-cured polyurethane finish coat paint, as specified in the Contract Documents, must be applied on traffic control signal mast arms, luminaire vertical pole shaft extensions, and luminaire mast arms, and other materials as specified in the Contract. Yellow - Yellow polyurethane finish coat paint, as specified in the Contract Documents, must be applied on vehicle and pedestrian signal indication housings (except polycarbonate), mast arm pole standard vertical pole shafts, traffic control signal pedestal shafts, pedestal slipfitter collars, pedestal reinforcing collars (wind collars), all signal bracketing and pipe fittings (except cast aluminum one way mounts), and pedestrian push button stations. Green - Dark Green polyurethane finish coat paint, as specified in the Contract Documents, must be applied on traffic control signal pedestal bases and mast arm pole standard transformer bases. 23-4

Local agencies my use colors other than those detailed above. Consult contract documents for the correct required paint colors. Dull Non-Reflective Black paint must be used on metal visors, directional louvers, background shields, and vehicle and pedestrian signal indication housing doors (inside and outside). Polycarbonate signal heads, background shields, and visors do not require painting. Construction Requirements Paint application must not start until the Engineer has given permission and weather conditions are favorable. Paint must not be applied when the ambient air temperature is below 40 Fahrenheit (4 Celsius), when the air is misty or the metal surfaces are damp or frosted. 23-5

Do not apply paint when wind or traffic causes dust, dirt or sand to be carried onto surfaces being painted. Prior to the application of paint, the surface must be inspected for damage and unsatisfactory areas must be made smooth, and after that, repainted. Paint must be thoroughly mixed before being removed from the container and kept mixed during the application. Any paint samples taken must be withdrawn from the Contractor s bucket while the paint is being applied, without mixing. 23-6

Application of paint must be done in a neat, workman like manner, by brushing, spraying or rolling. Regardless of the method, the resulting painted surface must be smooth and uniform, without skips, drips, or areas of excessive paint. The previous coat must be dried through. This will usually require at least three days for aluminum paints in good drying weather. Longer drying periods will be required between coats when unfavorable weather conditions prevail. A dry through condition check can be easily made by pressing the thumb against the paint film, exerting maximum pressure and simultaneously turning the thumb through an angle of 90 degrees. Examine the painted surface for loosening, detachment, wrinkling or other evidence of distortion, which indicate insufficient drying. 23-7

The total dry paint thickness of four coats of paint must be as specified in the Contract. An instrument for measuring paint thickness is available from the MnDOT Materials Lab. If a deficiency in the total paint thickness is discovered in any part of the surface and if the deficiency is not severe enough to require the application of additional paint, an equitable reduction in payment will be made. A determination of the reduction percentage must include consideration of the reduced life, as well as, that of paint. Cleanup Painting will not be considered complete until the paint coats are in satisfactory condition and all foreign matter has been cleaned from the painted members. If paint spills, drips, or debris blows onto the surface to create an undesirable appearance, it must be removed by an approved method to the satisfaction of the Engineer. 23-8

For specific details about painting, finish touchups, finish repair, etc. on your project refer to the Contract Documents. 23-9

This Page Intentionally Left Blank 23-10