SUBMITTAL SHEET. Project Submittals by

Similar documents
Submittal Sheet. Product: Item# Description Unit Pack

SUBMITTAL TRANSMITTAL

Translucents Canopies. Design and Installation Guide October, 2017

SECTION BULLET- RESISTANT DOORS

SECTION METAL FABRICATIONS

Originally Issued: 08/28/2015 Revised: 08/26/2016 Valid Through: 08/31/2017

Installation Manual for Thermo Panel

FASTENERS BUILDING DEPARTMENT

Barofor Round System (polyester coated) Panels, Posts, Accessories

GUIDELINE SPECIFICATIONS

SIM. Mass Loaded Vinyl

Heckmann Building Products Inc. DOVETAIL SLOT AND ANCHORS SPECIFICATION SECTION MASONRY ANCHORS AND ACCESSORIES PART 1 GENERAL

METAL LATH PLASTERING ACCESSORIES

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

Coatings ASTM B117 SST Salt Spray Test Kesternick Phosphate Zinc E-Coat Dip Spin Coatings

B. Related Sections: The following Sections contain requirements that relate to this Section:

Technical Note No. 026

SECTION CHAIN LINK FENCING

MH Series Mitered Frames shall be as manufactured or furnished by Republic Doors and Frames, McKenzie, Tennessee

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS

PART MATERIALS. Section Fencing Materials. Description

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

Installation Manual for M4-Exterior Sheathing

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

Hex Cap Screws Coarse & Fine Thread

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

SECTION WOOD SHINGLES

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

SECTION HOLLOW METAL DOORS AND FRAMES

Nails, Fasteners, Connectors, and Framing

CSI Section DMI Light Gage Structural Steel Framing Systems. Blocking Fire Rated Pre-cut (Proprietary) Furring Wall Preservative Treated

NORMATIVE REFERENCES

USG BORAL HIGHLANDS CEILING SYSTEM Technical Manual (Installation Guide)

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson.

NORMATIVE REFERENCES

USG Ceiling Solutions USG PERFORATIONS METAL CEILING SYSTEMS SELECTION GUIDE

Multi-Institutional Academic Health Science & Research Center Evansville, IN

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Specialty Fastening Systems Solutions for the Construction Industry

ESR-1129 Reissued June 1, 2011 This report is subject to renewal in two years.

Slate Shingle Specifications

UNIFIED FACILITIES GUIDE SPECIFICATIONS

1.04 QUALITY ASSURANCE

RR-F-191/1D 14 May SUPERCEDING RR-F-191/1C July 22, 1981 FEDERAL SPECIFICATION SHEET

TECHNICAL DESIGN CATALOG

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

SECTION CARPENTRY

METALWORKS TARTAN PANELS General Installation Instructions

ROOFING City of Grand Rapids Building Safety Division

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

WoodWORKS Channeled Plank

Double Bar Plate Dowels for Saw-Cut Contraction Joints

Item 550 Chain Link Fence

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

SHEET METAL FLASHING AND TRIM Christ on the Mountain

APPENDIX FENCE GENERAL NOTES

Technical Data VARIABLES

Design and Construction Standards SECTION ATHLETIC LOCKERS

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

Securifor Polyester Coated Welded Mesh Panels

*Revised September 1, 2003

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION CABLE TRAYS

AXIOM Classic Trim. Assembly and Installation Instructions

A. Extent of structural precast concrete work is shown on drawings and in schedules.

SECTION CHAIN LINK FENCING AND GATES

Standard Specification for Fence Fittings 1

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

PROJECT INSTRUCTIONS Roofing

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

Drywall, Wood and Truss Uplift

AXIOM Classic Trim Installation Instructions

Mechanical Support Systems, Inc.

EXTERIOR NEW WALL CONSTRUCTION

eco-shake INSTALLATION INSTRUCTION

WOODWORKS Walls. Installation Instructions WALL

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

METALWORKS Linear (Interior & Exterior Applications)

Engineering Test Report

Hospital Grade Welded Ceiling System

Technical Note No. 028

TRELLIS. Trellis SOUTHERN FOREST PRODUCTS ASSOCIATION SOUTHEASTERN LUMBER MANUFACTURERS ASSOCIATION

WoodTrac Direct Mount Ceiling System

Powder Actuated Fasteners - Drive Pins

Subject: Specification Compliance

Go Your Own Way. Libretto. Gridless Metal Ceiling System

Transcription:

Galvanized Tie Wire and Hanger Wire Submittal of Product Performance SUBMITTAL SHEET Project Submittals by GRABBER CONSTRUCTION PRODUCTS, INC. Submittal Date: Contract Number: Project Name: Section Number: Contractor s Name: Page: 1/1

GALVANIZED STEEL TIE WIRE AND HANGER WIRE Meeting: ASTM A641 SCOPE This submittal covers wire for hanging and tying support CRC, Cold Rolled Channel grid work for stucco, acoustical or drywall ceilings. The selection of the accessory shall be determined by numerous factors not limited to: the project location, climate and environment resulting from excessive salt, moisture, humidity, pollution, wear, and temperature changes. MATERIALS Class 1 Coated (Hot Dip Galvanized) Wire THICKNESS OF BASE MATERIALS Minimum thicknesses meet ASTM C1063 Section FINISH Hot Dip Galvanized PACKAGING AND PACKAGE MARKING Tie Wire is generally available in 28 thru 45 inches lengths per hank. Straight and cut Hanger Wire is generally available in Bundles of 50 pieces 3 foot thru 34 feet Each factory hank shall be marked with manufacturer s name and wire diameter. CERTIFICATION When required a certification that products meets the requirements of ASTM A641 shall be provided. Grabber GALVANIZED WIRE MEETS THE FOLLOWING SPECIFICATIONS ASTM A510 Standard Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel, and Alloy Steel ASTM A641 Standard Specification for Zinc Coated (Galvanized) Carbon Steel Wire ASTM C1063 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster ASTM C1047 Standard Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base Country of Origin China, Taiwan, ROC Page: 2/5

16Ga (0.0625 in.) 18GA (0.0475 in.) GALVANIZED STEEL TIE WIRE Class 1 Coated Annealed Dead Soft meeting ASTM A641 This submittal covers wire to support CRC, cold formed channel used to support grid work for stucco, acoustical and drywall ceilings. ITEM DESCRIPTION Gauge DIAMETER LENGTH TW1645 TIE WIRE, 16 GAUGE X 45 16 0.0625 45 TW1828 TIE WIRE, 18 GAUGE X 28" 18 0.0475 28 TW1830 TIE WIRE, 18 GAUGE X 30" 18 0.0475 30 TW1845 TIE WIRE, 18 GAUGE X 45 18 0.0475 30 Refer to ASTM C754 for support spacing, fastener selection and further information regarding the proper installation with gypsum panel products. Refer to ASTM C1063 for support spacing, fastener selection and further information regarding the proper installation with metal lath. Page: 3/5

8GA 0.1620-in. 9GA 0.1480-in. 12GA 0.1055-in. GALVANIZED STEEL WIRE Class 1 Coated Annealed Dead Soft meeting ASTM A641 This submittal covers wire to for tying support Cold Rolled Channel, (CRC) used in the installation of the support horizontal and vertical grid work for stucco, acoustical or drywall ceilings. The selection of the accessory shall be determined by numerous factors not limited to: the project location, climate and environment resulting from excessive salt, moisture, humidity, pollution, wear, and building aesthetics. ITEM Description Length Gauge HW1203 HANGER WIRE 3' 12 HW1204 HANGER WIRE 4' 12 HW1205 HANGER WIRE 5' 12 HW1206 HANGER WIRE 6' 12 HW1207 HANGER WIRE 7' 12 HW1208 HANGER WIRE 8' 12 HW1210 HANGER WIRE 10' 12 HW1212 HANGER WIRE 12' 12 HW1214 HANGER WIRE 14' 12 HW1216 HANGER WIRE 16' 12 HW1218 HANGER WIRE 18' 12 HW1220 HANGER WIRE 20' 12 HW1222 HANGER WIRE 22' 12 HW1224 HANGER WIRE 24' 12 HW1226 HANGER WIRE 26' 12 HW1228 HANGER WIRE 28' 12 HW1230 HANGER WIRE 30' 12 HW1234 HANGER WIRE 34' 12 ITEM Description Length Gauge HW803 HANGER WIRE 3' 8 HW804 HANGER WIRE 4' 8 HW805 HANGER WIRE 5' 8 HW806 HANGER WIRE 6' 8 HW808 HANGER WIRE 8' 8 HW810 HANGER WIRE 10' 8 HW812 HANGER WIRE 12' 8 HW814 HANGER WIRE 14' 8 HW816 HANGER WIRE 16' 8 HW820 HANGER WIRE 20' 8 HW904 HANGER WIRE 4' 9 HW905 HANGER WIRE 5' 9 HW906 HANGER WIRE 6' 9 HW908 HANGER WIRE 8' 9 HW910 HANGER WIRE 10' 9 HW912 HANGER WIRE 12' 9 HW916 HANGER WIRE 16' 9 HW920 HANGER WIRE 20' 9 Refer to ASTM C754 for support spacing, fastener selection and further information regarding the proper installation with gypsum panel products. Refer to ASTM C1063 for support spacing, fastener selection and further information regarding the proper installation with metal lath. Master bundle of hanger wire Page: 4/5

SUBMITTAL APPROVALS: Prefabricated Corner Assembly JOB NAME CONTRACTOR DATE TRADEMARKS: The following trademarks used herein are owned by Grabber Construction Products, Inc.: GRABBER. NOTICE: We shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instruction or for other than the intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be (30) days of the date it was or reasonably should have been discovered. Page: 5/5