Power Line Series Compensation Demonstrator (EMS Version)

Similar documents
9063-RC Data Acquisition and Control Interface

AC Power Transmission Training System Add- On to ( )

Distribution Transformer Trainer

DC and AC Power Circuits Training System

9063 Data Acquisition and Control Interface

Data Acquisition and Control Interface

Electricity and Electronics Training System - Module 1 and 2

Digital Communications Simulation Software (LVSIM -DCOM)

Electricity Fundamentals Training System

PlantPAx Distributed Control System (DCS) Demonstrator - Pressure, Flow, Level, Temperature (3531-V0)

Orbit Simulator Software (9581-H0)

Antenna Training and Measuring System

AC Power Transmission Training System

AC Power Transmission Training System

CNC Lathe System Training System (Light Duty)

CNC Mill Training System (Heavy Duty)

Servo Robot Training Systems

CNC Mill Training System (Light Duty)

Satellite Communications Training System

Exercise 2. The Buck Chopper EXERCISE OBJECTIVE DISCUSSION OUTLINE. The buck chopper DISCUSSION

5250 Servo Robot Training Systems

Single-Phase Grid-Tied Inverter (PWM Rectifier/Inverter)

5500 CNC Lathe Systems (Heavy Duty)

Voltage Compensation of AC Transmission Lines Using a STATCOM

Exercise 7. The Buck/Boost Chopper EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. The Buck/Boost Chopper

Operation of a Three-Phase PWM Rectifier/Inverter

The Single-Phase PWM Inverter with Dual-Polarity DC Bus

Exercise 4. Ripple in Choppers EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Ripple

Four-Quadrant Dynamometer/Power Supply

Introduction to High-Speed Power Switching

Communications Technologies Training Systems

Exercise 6. The Boost Chopper EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. The boost chopper

Generator Operation with Speed and Voltage Regulation

Exercise 8. The Four-Quadrant Chopper EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. The Four-Quadrant Chopper

Three-Phase Transformer Banks

Solving Simple AC Circuits Using Circuit Impedance Calculation

Dynamic Power Factor Correction Using a STATCOM


Harmonic Reduction using Thyristor 12-Pulse Converters

The Discussion of this exercise covers the following points:

Microwave Technology Training Systems

University of Saskatchewan Department of Electrical and Computer Engineering EE Power Electronics Lab Exercise 4

Single-Phase Power Transformers

Variable Gain Photoreceiver Fast Optical Power Meter

8010-7A Home Energy Production Training System

The Discussion of this exercise covers the following points: Phasor diagrams related to active and reactive power

Variable Gain Photoreceiver Fast Optical Power Meter

Exercise 3. Phase Sequence EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Phase sequence fundamentals

Single-Phase Power Transformers

Variable Gain Photoreceiver - Fast Optical Power Meter

True RMS Bench Multimeters 2831E and 5491B

200 MHz Variable Gain Photoreceiver

PMSM Control Using a Three-Phase, Six-Step 120 Modulation Inverter

Speed Feedback and Current Control in PWM DC Motor Drives

Three-Phase AC Power Circuits

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Three-Phase AC Power Circuits

Exercise 3. Doubly-Fed Induction Generators EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Doubly-fed induction generator operation

True RMS Bench Multimeter 5492B

Portable Multi-Channel Recorder Model DAS240-BAT

Exercise 1. Basic PWM DC Motor Drive EXERCISE OBJECTIVE DISCUSSION OUTLINE. Block diagram of a basic PWM dc motor drive DISCUSSION

True RMS Bench Multimeters 2831E and 5491B

Bidirectional PWM DC Motor Drive with Regenerative Braking

Data Sheet Version R&S RT-ZVCxx Multi-Channel Power Probe Specifications

WaveStation Function/Arbitrary Waveform Generators

Electricity and New Energy. DC Power Electronics. Courseware Sample F0

True RMS Bench Multimeter 5492B

Digital Communications Training Systems

Grid-Tied Home Energy Production Using a Solar or Wind Power Inverter without DC-to-DC Converter

TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM TCA292D Datasheet

Ultra Low-Noise Variable Gain Low-Frequency Voltage Amplifier

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Variable Gain Low Frequency Voltage Amplifier

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

evolution wireless G4 ew 112 P G4 Camera Lavalier ME 2 Set ew 122 P G4 Camera Lavalier ME 4 Set

Variable Gain 100 MHz Wideband Voltage Amplifier

Model 3102D 0-2 kv H.V. Power Supply

ArbStudio Arbitrary Waveform Generators

Low Noise Variable Gain Low Frequency Voltage Amplifier

evolution wireless G4 ew 512 P G4 Pro Camera Lavalier MKE 2 Set

5320A. Multifunction Electrical Tester Calibrator. Extended Specifications

evolution wireless G4 ew 100 ENG G4 Camera Lavalier + Plug-on Transmitter Set

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

Model LIA100. Lock-in Amplifier

Arbitrary/Function Generator AFG1000 Series Datasheet

evolution wireless G4 ew 135 P G4 Camera Handheld Set

WaveStation Function/Arbitrary Waveform Generators

evolution wireless G4 ew 100 G4-ME2 ew 100 G4-ME4 Lavalier Set

AC Current Probes CT1 CT2 CT6 Data Sheet

Variable-Gain High Speed Current Amplifier

CMC 256plus - protection relay test set and universal calibrator

evolution wireless G4 ew 300 G4-Base SK-RC Bodypack Base Set

Power Circuits and Transformers

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

evolution wireless G4 ew 500 FILM G4 Pro Camera Lavalier MKE 2 +

DC Electronic Loads 8500 Series

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

evolution wireless G4 ew 300 G4-HEADMIC1-RC Bodypack Headmic Set

Agilent U2300A Series USB Modular Multifunction Data-Acquisition Devices

Transcription:

Power Line Series Compensation Demonstrator (EMS Version) LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 07/2018

Table of Contents General Description 2 2 Table of Contents of the (s) 2 Additional Equipment Required to Perform the Exercises 2 Specifications 2 Module Options Description 3 General Description The Power Line Series Compensation Demonstrator (EMS Version) is a variant of the Power Line Series Compensation Demonstrator, 8362, that does not include any test equipment. It is mounted in a full-size EMS module and uses a Data Acquisition and Control Interface, 9063, with the Power Line Series Compensation Function Set, 9069-S, and the LVDAC-EMS software for all the required measurements. Description Power Line Series Compensation Demonstrator (User Guide) 31993-E0 Table of Contents of the (s) Power Line Series Compensation Demonstrator (User Guide) (31993-E0) 1 Power Transfer Capability of a Transmission Line 2 Effects of Series Compensation on Power Transfer Capability and System Stability 3 Effect of Series Compensation on Regulation of the Receiver Voltage 4 Reduction of the Transmission Losses on Parallel Lines Using Series Compensation Additional Equipment Required to Perform the Exercises 1 Data Acquisition and Control Interface 9063-00 1 Power Line Series Compensation Function Set 9069-S0 Specifications Parameter Power Requirement Current Service Installation Line 1 Simulation Length Simulated Nominal Power Line 2 Simulation Length Simulated Nominal Power Value 2 A (circuit-breaker protected) Standard single-phase ac outlet 200 km 4500 MW 300 km 3000 MW Compensation 17 %, 25 %, and 34 % Front panel switches for various system configurations Physical Characteristics Intended Location Dimensions (H x W x D) Net Weight Toggle type (16), rotary type (1) On a table able to support the weight of the equipment 308 x 291 x 440 mm (12.1 x 11.5 x 17.3 in) TBE 2 Festo Didactic

Module Options Description Data Acquisition and Control Interface 9063-00 The Data Acquisition and Control Interface (DACI) is a versatile USB peripheral used for measuring, observing, analyzing, and controlling electrical and mechanical parameters in electric power systems and power electronics circuits. For these purposes, a set of computer-based instruments as well as a variety of control functions are available for the DACI. These instruments and control functions are accessed through the LVDAC-EMS software. The LVDAC-EMS software, as well as all available upgrades, is free and can be downloaded anytime on the Festo Didactic website. Together, the DACI and the LVDAC-EMS software allow training in various areas such as electric power technology, ac/dc machines, renewable energy, transmission lines, and power electronics using modern and versatile measuring instruments and control functions. LVDAC-EMS also offers the possibility to use pre-built SCADA interfaces for several applications to ease the view and understanding of the process taking place. The user guide provided allows students to quickly become familiar with the instruments and control functions available. 9063-0 includes only the DACI, 9063, with no control function set activated. This enables the user to customize the DACI by individually picking the computer-based instruments and control function sets that he wants to activate in the DACI. Alternately, variant 9063-0 is also used in several courses as an extension module. This means that it is used in conjunction to another DACI in which particular control function sets are activated. Both DACIs are connected to a single computer running LVDAC-EMS. When used in such a way, variant 9063-0 shares all control function sets activated in the other DACI. For example, if the Computer-Based Instrumentation Function, 9069-1, and the Three-Phase PWM Rectifier/Inverter Control Function Set, 9069-5, are activated in the other DACI, these function sets will also be available in variant 9063-0. This enables the user to perform courses requiring the use of more than one DACI without having to activate the same control function sets in all DACIs. Description Computer-Based Instruments for EMS (User Guide) 86718-E0 Table of Contents of the (s) Computer-Based Instruments for EMS (User Guide) (86718-E0) 1 Familiarization with the Metering Window and the Data Table 2 Familiarization with the Oscilloscope 3 Familiarization with the Phasor Analyzer 4 Familiarization with the Harmonic Analyzer 5 Measuring Three-Phase Power Using the Metering Window Additional Equipment Required to Perform the Exercises Festo Didactic 3

1 1 Personal Computer 8990-00 Optional Equipment 1 24 V AC Power Supply 2 30004-20 Specifications Parameter Power Requirements Voltage Maximum Current Frequency Insulated Voltage Inputs (4) Range (Low / High Scales) Impedance (Low / High Scales) Bandwidth Accuracy Insulation Measurement Category Insulated Current Inputs (4) Range (Low / High Scales) Impedance (Low / High Scales) Bandwidth Accuracy Insulation Measurement Category Analog Inputs (8) Voltage Range Impedance Bandwidth Measured Parameters Parameter-to-Voltage Ratio A/D Converter for Insulated and Analog Inputs (16) Type Resolution Integral Non-Linearity Differential Non-Linearity Maximum Sampling Rate FIFO Buffer Size Analog Outputs (2) Voltage Range (2) Operational Load Impedance D/A Converter for Analog Outputs (2) Type Resolution Integral Non-Linearity Differential Non-Linearity Digital Inputs (3) Value 24 V 0.4 A 50/60 Hz -80 to +80 V / -800 to + 800 V (user-selectable through software) 326.6 kω / 3.25 MΩ DC to 65 khz (-3 db) 1% (dc to 10 khz) 800 V CAT II (283 V ac/400 V dc versus ground) -4 to +4 A / -40 to +40 A (25 A rms) 5 mω / 50 mω DC to 65 khz (-3 db) 1% (dc to 10 khz) 800 V CAT II (283 V ac/400 V dc versus ground) -10 to +10 V > 10 MΩ DC to 125 khz User-selectable through software User-determined through software Successive approximation 12 bits ±1.5 LSB ±1 LSB 600 ksamples/s (one channel) 16 ksamples -10 to +10 V > 600 Ω Resistor string 12 bits ±8 LSB -0.5 to +0.7 LSB Types Encoder (2), synchronization (1) 1 Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user. Only one computer is required per station. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo representative to obtain the correct part. 2 Required if power is not supplied by the Power Supply, 8821-2. This model is available in multiple voltage- and frequency dependent variants. Contact a Festo representative to obtain the correct part. 4 Festo Didactic

Parameter Signal Level Maximum Input Frequency Impedance Digital Outputs (9) Types Signal Level Maximum Output Frequency Impedance Control Functions Activated Set Communication Port Value 0-5 V (TTL compatible) 50 khz 5 kω Control (6 on a DB9 connector and 2 on 2 mm banana jacks), synchronization (1 on a DB9 connector) 0-5 V (TTL compatible) 20 khz (software-limited) 200 Ω Type USB 2.0 Accessories Included Accessories 2 m USB interconnection cable (1) Physical Characteristics Dimensions (H x W x D) Net Weight No control function set is activated in the DACI, 9063-0. When used as an extension module to another DACI, all control function sets activated in the other DACI are also activated in 9063-0. 24 V power cable (1) 2 mm banana plug test leads (3) DB9 connector control cable (1) 154 x 287 x 410 mm (6.1 x 11.3 x 16.1 in) 3.9 kg (8.6 lb) Power Line Series Compensation Function Set 9069-S0 The Power Line Series Compensation Function Set enables the Series Compensation function in LVDAC-EMS. Additional Equipment Required to Perform the Exercises 1 Power Line Series Compensation Demonstrator (EMS Version) 8362-A0 Festo Didactic 5

Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification. Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered trademarks of their respective holders. Festo Didactic Inc. 2018. All rights reserved. Festo Didactic SE Rechbergstrasse 3 73770 Denkendorf Germany P. +49(0)711/3467-0 F. +49(0)711/347-54-88500 Festo Didactic Inc. 607 Industrial Way West Eatontown, NJ 07724 United States P. +1-732-938-2000 F. +1-732-774-8573 Festo Didactic Ltée/Ltd 675 rue du Carbone Québec QC G2N 2K7 Canada P. +1-418-849-1000 F. +1-418-849-1666 www.labvolt.com www.festo-didactic.com 6 Festo Didactic