TRIO-PS-2G/1AC/24DC/5

Similar documents
MINI-PS AC/24DC/1.3

MINI-PS AC/2X15DC/1

QUINT-PS-24DC/24DC/10

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

QUINT-PS/ 3AC/24DC/10

QUINT-PS AC/24DC/40

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 3AC/24DC/40

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

QUINT-PS/ 1AC/24DC/20

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

QUINT-PS/1AC/24DC/10. Power supply unit. Data sheet. 1 Description

Power supply CP-E 24/0.75

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Type CP-S, CP-C & CP-A Switch mode

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-D 24/1.3

Power supply CP-T 24/40.0 Primary switch mode power supply

CP-T range Product group picture

CP-T range Benefits and advantages

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-D 12/2.1

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

CP-E range Benefits and advantages

MINI MCR-SL-UI-f(-SP)

PHOENIX CONTACT - 09/2009

Switching power supplies CP range, Linear power supplies CP-L range. Content

MINI MCR-SL-UI-I-LP-NC

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Primary switch mode power supplies Product group picture

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

PHOENIX CONTACT

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

MACX MCR-UI-UI-UP(-SP)(-NC)

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

PHOENIX CONTACT

For Immediate Delivery call KMParts.com at (866)

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

Transformers, Power Supply Units and Socket Outlets

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Power Supplies 3. SDN-C Compact DIN Rail Series

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Electronic timer CT-TGD.22

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

INTERFACE. User Manual

Datasheet. PRO-M Series Power Supplies

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

LDW240 Series are single, two or three phase DIN Rail Switching Power Supplies.

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Electronic Circuit Protector ESX10-T

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Electronic timer CT-SDD.22

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

PHOENIX CONTACT - 01/2007

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

24 V DC, 12 W output 12 V DC, 12 W output 24 V DC, 36 W output

Three-phase monitoring relay CM-PFS

Installation / Monitoring Technique

Product Specification sheet

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

wenlok.com.mx Switched-mode and uninterruptible power supplies, and electronic fuses Let s connect. Power supply Catalogue 2015/2016

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

Device circuit breakers Selective power distribution: branch out, individual adaptation, modular extension

Output Voltage* (nom.)(adjustable)

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Thyristor power controller B DI1002 V1.0 Manual/Operating instructions

Electronic Circuit Protector ESX10

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

High precision measurement system for current and voltage IHC-A/B-RM01/03

Transcription:

TRIOPS2G/1AC/24DC/5 Power supply unit Data sheet 105900_en_01 PHOENIX CONTACT 20150831 1 Description TRIO POWER power supplies with standard functionality The power supplies of the TRIO POWER family convince due to their slim and robust design. The dynamic boost (1.5 x I N for 5 seconds) absorbs starting currents and short overload situations securely during operation and without a drop in output voltage. The pushin connection technology on the front enables fast and toolfree wiring of the devices. Features Especially slim design Worldwide use, thanks to widerange input Safe operation, thanks to electrically and mechanically robust design Reliable starting of heavy loads, thanks to dynamic boost (1.5 x I N for 5 seconds) Simplified error diagnostics for remote signaling via DC OK signal contact OVP (Over Voltage Protection) limits surge voltages to 30 V (EN611312) Toolfree connection via pushin connection technology Technical data (short form) Nominal input voltage range 100 V AC... 240 V AC 110 V DC... 250 V DC 50 Hz... 60 Hz Frequency range Nominal output voltage > 24 V DC, constant capacity restricted Nominal output current I N / I Dyn 5 A / 7.5 A (5 s) Residual ripple 50 mv PP Protection against surge voltage on 30 V DC the output MTBF (IEC 61709, SN 29500) Efficiency for 230 V AC and nominal values Maximum power dissipation NO Load 24 V DC ±1 % 24 V DC... 28 V DC > 3380000 h (25 C) > 1970000 h (40 C) > 900000 h (60 C) > 90 % < 1 W Power loss nominal load max. < 16 W Ambient temperature (operation) 25 C... 70 C > 60 C Derating: 2,5 %/K Weight 0.45 kg Dimensions W/H/D 35 mm / 130 mm / 115 mm Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products.

TRIOPS2G/1AC/24DC/5 2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 3 5 Safety regulations and installation notes... 7 6 Basic circuit diagram... 7 7 Structure... 8 8 Cooling... 8 9 Mounting position and dimensions... 9 9.1 Mounting position... 9 9.2 Device dimensions... 10 10 Mounting/removal... 11 10.1 Assembly... 11 10.2 Removal... 11 11 Device connection terminal blocks... 11 11.1 Pushin connection technology... 11 12 Input... 12 12.1 Position of input terminals... 12 12.2 Protection of the primary side... 12 13 Output... 13 13.1 Position of output terminals... 13 13.2 Protection of the secondary side... 13 13.3 Output characteristic curve... 13 14 Dynamic boost... 14 15 Signaling... 14 15.1 DC OKLED... 14 15.2 Floating signal contact... 14 16 Derating... 15 16.1 Temperaturedependent derating... 15 16.2 Positiondependent derating... 16 17 Operating modes... 19 17.1 Series operation... 19 17.2 Parallel operation... 19 17.3 Redundant operation... 19 17.4 Increasing power... 20 105900_en_01 PHOENIX CONTACT 2

TRIOPS2G/1AC/24DC/5 3 Ordering data Description Type Order No. Pcs./Pkt. Primaryswitched TRIO POWER power supply with pushin connection for DIN rail mounting, input: 1phase, output: 24 V DC/5 A TRIOPS2G/1AC/24DC/5 2903148 1 Accessories Type Order No. Pcs./Pkt. Multichannel, electronic device circuit breaker with active current limitation for protecting four loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails. Multichannel, electronic device circuit breaker with active current limitation for protecting eight loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails. VARIOFACE module, with two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 70.4 mm VARIOFACE module with pushin connection and two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 57.1 mm CBM E4 24DC/0.510A NOR 2905743 1 CBM E8 24DC/0.510A NOR 2905744 1 VIP2/SC/PDM2/24 2315269 1 VIP3/PT/PDM2/24 2903798 1 Our range of accessories is being continually extended, our current range can be found in the download area. 4 Technical data Input data Nominal input voltage range (for DC, connect a suitable fuse) Input voltage range Electric strength, max. 100 V AC... 240 V AC 15 %... 10 % 110 V DC... 250 V DC 85 V AC... 264 V AC 99 V DC... 275 V DC 300 V AC 15 s Current consumption (for nominal values) 2.2 A (100 V AC) 1.1 A (240 V AC) 1.4 A (110 V DC) 0.6 A (250 V DC) Frequency 50 Hz... 60 Hz Inrush current limitation (at 25 C) 16 A (typical) Inrush surge current I 2 t < 0.6 A 2 s Input fuse internal (device protection) 6.3 A Mains buffering > 20 ms (120 V AC) > 100 ms (230 V AC) A choice of suitable fuses 6 A... 16 A (Characteristics B, C, D, K) Input connection data Connection method Pushin connection Conductor cross section, solid 0.2 mm²... 4 mm² Conductor cross section, flexible 0.2 mm²... 2.5 mm² Cross section AWG 24... 12 Stripping length 10 mm 105900_en_01 PHOENIX CONTACT 3

TRIOPS2G/1AC/24DC/5 Output data Nominal output voltage 24 V DC ±1 % Setting range of the output voltage Output current 24 V DC... 28 V DC (> 24 V DC, constant capacity restricted) 5 A 7.5 A (5 s) Control deviation < 1 % (change in load, static 10 %... 90 %) < 3 % (Dynamic load change 10 %... 90 %, 10 Hz) < 0.1 % (change in input voltage ±10 %) Efficiency > 90 % (for 230 V AC and nominal values) Rise time 12 ms (U OUT (10 %... 90 %)) Residual ripple 50 mv PP Connection in parallel Connection in series Protection against surge voltage on the output Output connection data Connection method Yes, for redundancy and increased capacity Yes 30 V DC Pushin connection Conductor cross section, solid 0.2 mm²... 4 mm² Conductor cross section, flexible 0.2 mm²... 2.5 mm² Conductor cross section AWG 24... 12 Stripping length 8 mm Signaling DC OK Types of signaling Signal threshold Type of signaling Status indicator Type of signaling Maximum switching voltage Continuous load current LED, floating signal contact U OUT < 0.9 x U N LED green Switch contact 30 V AC/DC 100 ma Signal connection data Connection method Pushin connection Conductor cross section, solid 0.2 mm²... 1.5 mm² Conductor cross section, flexible 0.2 mm²... 1.5 mm² Conductor cross section AWG 24... 16 Stripping length 8 mm General data Insulation voltage input/output Degree of protection Protection class Inflammability class in acc. with UL 94 (housing) MTBF (IEC 61709, SN 29500) Type of housing Hood version Dimensions W / H / D (state of delivery) Weight 4 kv AC (type test) 3 kv AC (routine test) IP20 II (in closed control cabinet) V0 > 3380000 h (25 C) > 1970000 h (40 C) > 900000 h (60 C) Polycarbonate Polycarbonate 35 mm / 130 mm / 115 mm 0.45 kg 105900_en_01 PHOENIX CONTACT 4

TRIOPS2G/1AC/24DC/5 Power consumption Maximum power dissipation NOLoad Power loss nominal load max. < 1 W < 16 W Ambient conditions Ambient temperature (operation) 25 C... 70 C (> 60 C Derating: 2,5 %/K) Ambient temperature (storage/transport) 40 C... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, noncondensing) Maximum altitude 5000 m (> 2000 m, observe derating) Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 6006826) 15 Hz... 150 Hz, 4g, 90 min. Shock 30g in each direction, according to IEC 60068227 Pollution degree 2 Climatic class 3K3 (in acc. with EN 60721) Standards Electrical Equipment for Machinery EN 602041 Electrical safety (of information technology equipment) IEC 609501/VDE 0805 (SELV) Electronic equipment for use in electrical power installations EN 50178/VDE 0160 (PELV) SELV IEC 609501 (SELV) and EN 602041 (PELV) Safe isolation DIN VDE 0100410 Limitation of mains harmonic currents EN 6100032 Network version/undervoltage Semi F470706 Rail applications EN 501214 Approvals UL UL Listed UL 508 UL/CUL Recognized UL 609501 Current approvals/permissions for the product can be found in the download area under phoenixcontact.net/products. 105900_en_01 PHOENIX CONTACT 5

TRIOPS2G/1AC/24DC/5 Conformance with EMC Directive 2004/108/EC Noise immunity according to EN 6100062 Electrostatic discharge EN 6100042 Electromagnetic HF field EN 6100043 Fast transients (burst) EN 6100044 Surge current loads (surge) EN 6100045 Conducted interference EN 6100046 EN 6100062 requirement Tested Housing contact discharge 4 kv (Test intensity 2) 6 kv (Test intensity 4) Housing air discharge 8 kv (Test intensity 3) 8 kv (Test intensity 4) Comments Criterion B Criterion A Frequency range 80 MHz... 1 GHz 80 MHz... 1 GHz Test field strength 10 V/m (Test intensity 3) 10 V/m (Test intensity 3) Frequency range 1.4 GHz... 2 GHz 1 GHz... 2 GHz Test field strength 3 V/m (Test intensity 2) 10 V/m (Test intensity 3) Frequency range 2 GHz... 2.7 GHz 2 GHz... 3 GHz Test field strength 1 V/m (Test intensity 1) 10 V/m (Test intensity 3) Comments Criterion A Criterion A Input 2 kv (Test intensity 3 asymmetrical) 4 kv (Test intensity 4 asymmetrical) Output 2 kv (Test intensity 3 asymmetrical) 2 kv (Test intensity 3 asymmetrical) Signal 1 kv (Test intensity 2 asymmetrical) 1 kv (Test intensity 2 asymmetrical) Comments Criterion B Criterion A Input Output 1 kv (Test intensity 2 symmetrical) 2 kv (Test intensity 3 asymmetrical) 0.5 kv (Test intensity 1 symmetrical) 0.5 kv (Test intensity 1 asymmetrical) 3 kv (Test intensity 3 symmetrical) 6 kv (Test intensity 4 asymmetrical) 1 kv (Test intensity 2 symmetrical) 2 kv (Test intensity 3 asymmetrical) Signal 1 kv (Test intensity 2 asymmetrical) 1 kv (Test intensity 2 asymmetrical) Comments Criterion B Criterion B Input/output asymmetrical asymmetrical Frequency range 0.15 MHz... 80 MHz 0.15 MHz... 80 MHz Voltage 10 V (Test intensity 3) 10 V (Test intensity 3) Comments Criterion A Criterion A Key Criterion A Criterion B Normal operating behavior within the specified limits. Temporary impairment to operational behavior that is corrected by the device itself. Emitted interference in acc. with EN 6100063 Radio interference voltage in acc. with EN 55011 Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential All technical specifications are nominal and refer to a room temperature of 25 C and 70% relative humidity at 2000 m above sea level. 105900_en_01 PHOENIX CONTACT 6

TRIOPS2G/1AC/24DC/5 5 Safety regulations and installation notes 6 Basic circuit diagram Before startup please ensure: Installation and startup may only be carried out by qualified personnel. The relevant countryspecific regulations must be observed. NOTE: Danger if used improperly The device is a builtin device. The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry environment. Do not subject the device to any load that exceeds the described limits. Do not subject the device to mechanical and/or thermal loads that exceed the specified limits. It is not permissible to open or modify the device. Do not repair the device yourself but replace it with an equivalent device. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from violation. CAUTION: Before startup please ensure: Connection must be performed by specialist personnel and protection against electric shock ensured. It must be possible to switch off the device outside the power supply according to the regulations in EN 609501 (e.g., by line protection on the primary side). All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! EXPLOSION HAZARD! Only remove equipment when it is disconnected and not in the potentially explosive area. DANGER Never carry out work on live parts! The housing can become very hot, depending on the ambient temperature and load! L/ N/ Figure 1 Key: Block diagram Rectification Switch Electrically isolated signal transmission Regulation Transformer Filter Floating switching output 13 14 105900_en_01 PHOENIX CONTACT 7

TRIOPS2G/1AC/24DC/5 7 Structure 8 Cooling 2 5 Output DC 24V 5A TRIO POWER Heat is dissipated from the power supply via the heatsinks integrated into the housing surfaces. Convection to dissipate heat from the power supply only takes place in small dimensions above the housing openings. 4 13 14 DC OK 3 2428V 1 Input AC 100240V L/ N/ 6 Figure 2 Function elements No. Description of the function elements 1. Connection terminal block input voltage: Input L/N 2. Connection terminal block output voltage: Output DC / 3. Potentiometer, output voltage: 24 V DC... 28 V DC 4. Signaling DC OK LED 5. Floating signal contact: max. 30 V AC/DC, 100 ma 6. Integrated universal snapon foot Figure 3 Convection The power supply can be aligned without minimum lateral clearance up to an ambient temperature of 40 C. In a temperature range up to 70 C, a lateral minimum clearance of 10 mm between two active components (e.g., power supply) is required. The device can be snapped onto all DIN rails in accordance with EN 60715 and should be mounted in the normal mounting position. To ensure sufficient wiring space to wire the power supply, we recommend a vertical minimum clearance from other devices of 50 mm. Depending on the cable duct used, a smaller clearance may be possible. 105900_en_01 PHOENIX CONTACT 8

TRIOPS2G/1AC/24DC/5 9 Mounting position and dimensions 9.1 Mounting position 35 115 TRIO POWER 50 Output DC 24V 5A 13 14 DC OK 230 2428V 130 Input AC 100240V L/ N/ Figure 4 Locked areas Possible mounting positions: Normal mounting position, installation depth 115 mm ( DIN rail) 105900_en_01 PHOENIX CONTACT 9

TRIOPS2G/1AC/24DC/5 9.2 Device dimensions 121 10 115 TRIO POWER 13 14 130 24 7,5 L/ N/ 24 5 9 35 40,5 Output DC 24V 5A 3,5 7,5 DC OK 2428V Input AC 100240V 68 80 78 45 10 Figure 5 Device dimensions 105900_en_01 PHOENIX CONTACT 10

TRIOPS2G/1AC/24DC/5 10 Mounting/removal 10.1 Assembly Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. A B 11 Device connection terminal blocks 11.1 Pushin connection technology All connection terminal blocks on the power supply have pushin connection technology on the front. The power supply is wired by simply plugging in the connecting cables, no tools are required. For the necessary connection parameters for the terminal blocks, please refer to the technical data. 11.1.1 Plug in connecting cable The wiring is carried out by simply plugging the connecting cable into the contact opening provided. Insert the connecting cable as far as it will go. A Figure 6 Assembly on standard DIN rail 10.2 Removal Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. Figure 7 A B D Removing the DIN rail C Figure 8 Insert connecting cable (pushin connection technology) 11.1.2 Loosen the connecting cable To disconnect the wiring, take a suitable screwdriver and insert it into the opening for release. Then carefully pull the connecting cable out of the contact opening. Figure 9 B A Release connecting cable (pushin connection technology) 105900_en_01 PHOENIX CONTACT 11

TRIOPS2G/1AC/24DC/5 12 Input The power supply can be operated on singlephase AC or DC power grids in accordance with the nominal input voltage. Connection is via the INPUT L/N connection terminal blocks. For operation on two of the phase conductors of a threephase system, an isolating facility for all poles must be provided. TNS L N PE TNC L PEN 12.2 Protection of the primary side Installation of the device must correspond to EN 60950 regulations. It must be possible to disconnect the device from the voltage using a suitable separator outside the power supply. For example, the primaryside line protection is suitable for this (see technical data). An internal, approved AC/DC fuse is available as device protection. Additional device protection is not required. If an internal fuse trips, this is due to a device fault. In this case, the device must be inspected in the factory. Opening the device or repairing it yourself is prohibited. L/ N/ L/ N/ L N TT L N it L1 L2 L3 Input AC 100240V L/ N/ L/ N/ L/ N/ Figure 12 Schematic diagram, switching the input terminals Figure 10 Network types 12.1 Position of input terminals Input AC 100240V L/ N/ Figure 11 Position of input terminals 105900_en_01 PHOENIX CONTACT 12

TRIOPS2G/1AC/24DC/5 13 Output A DC voltage for supplying the load is provided at the output of the power supply. The load is connected via the OUTPUT / connection terminal blocks. By default, the power supply is preset to a nominal output voltage of 24 V DC. The output voltage can also be set to the range from 24 V DC to 28 V DC using the potentiometer in order to compensate for a possible voltage drop due to the long cable lengths between the power supply and the load to be supplied. 13.1 Position of output terminals Output DC 24V 5A Figure 14 Output DC 24V 5A R Load Schematic diagram, switching the output terminals 13.3 Output characteristic curve The power supply works with a dynamic power reserve, the dynamic boost, as shown in the U/I characteristic curve in the figure. In the event of a secondaryside short circuit or overload, the output current is limited to 1.5 x I N. The module does not switch off, but supplies a continuous output current instead. The secondary voltage is then reduced until the short circuit is eliminated. The U/I characteristic curve with the dynamic power reserve enables high switchon currents of capacitive loads or inductive loads to be supplied reliably. U [V] OUT U N dyn. Boost t 5 s U < 0,9 x U N Figure 13 Position of output terminals 13.2 Protection of the secondary side The power supply is electronically shortcircuitproof and idlingproof. In the event of an error, the output voltage is limited. It must be ensured that all output cables are dimensioned accordingly for the maximum output current or have separate protection. The connecting cables on the secondary side should have large cross sections to keep the voltage drops in the cables as low as possible. Figure 15 I N 1,5 x I N I OUT [A] U/I characteristic curve with dynamic load reserve U N = 24 V I N = 5 A I dyn. BOOST = 7,5 A P N = 120 W P dyn. BOOST = 180 W 105900_en_01 PHOENIX CONTACT 13

TRIOPS2G/1AC/24DC/5 14 Dynamic boost The following example is used to explain how the power supply dynamic boost functions. Example: The power supply supplies a connected base load of 80% until time point t 1 (see illustration, schematic diagram of the dynamic boost behavior). If an additional load is activated while the power supply is in operation, the dynamic boost is requested for the period of time t 1 to t 2. The power supply provides the maximum dynamic power reserve of an additional 70% (ΔP dyn. Boost = 1.5 x I N x U N P Initial load ). As such, the requested overall total power corresponds to 150% of the nominal power. This power can be accessed directly for at least 5 s in the event that the output voltage remains the same. On reaching time point t 2, the dynamic boost is once more returned to the output value of the base load for thermal offloading of the power supply. In this case, the base load amounts to the same value of 80%, as prior to time point t 1. If the request to supply the load still exists, when the time intervals t 2 to t 3 have expired (at least 7 s), a new cyclical switching of the dynamic power reserve occurs, to a total of 70%. 15 Signaling 15.1 DC OKLED The DC OKLED is available for function monitoring. The LED is continuously illuminated when the output voltage is > 90 % of the nominal output voltage U OUT (24 V DC). 13 14 DC OK 2428V I OUT [A] I dyn. Boost 100% 80% Figure 17 Location of the elements Figure 16... 5s 7s 5s 7s t 1 t 2 t 3 t 4 t 5 t [s] Schematic diagram of dynamic boost behavior 15.2 Floating signal contact A floating diagnostics contact can be used to forward data to a higherlevel control system. When opened, the diagnostics contact indicates an underrange of more than 90% for the nominal output voltage U OUT. Depending on the connected base load, the power supply firmware determines the time intervals for the dynamic boost procedure or the time required for the release of thermal tension. The ratio of dynamic boost time and time for thermal tension release always varies, depending on load. PLC Digital Input DI x max. 30V AC/DC 100 ma 13 14 DC OK 2428V Figure 18 Wiring principle 105900_en_01 PHOENIX CONTACT 14

TRIOPS2G/1AC/24DC/5 16 Derating 16.1 Temperaturedependent derating The device provides both the I N nominal output current and the I dyn. BOOST dynamic output current at ambient temperatures up to 60 C. For ambient temperatures above 60 C, the ambient power must be decreased by 2.5% per Kelvin increase in temperature. For ambient temperatures above 70 C or in the event of a thermal overload, the device does not switch off. The output power will be decreased by enough to allow device protection. Once the device has cooled down, the output power will be increased again. I OUT [A] 1,5 x I N dyn. Boost t 5 s I N 0 25 20 40 60 [ C] Figure 19 Temperature derating in normal mounting position 105900_en_01 PHOENIX CONTACT 15

TRIOPS2G/1AC/24DC/5 16.2 Positiondependent derating The power supply can be installed onto all 35 mm DIN rails according to EN 60175. The normal mounting position of the power supply is horizontal. When installing in a different mounting position, derating should be adhered to. The characteristic curve can be used to determine the maximal output power to be drawn for each ambient temperature for different mounting positions. Normal mounting position Rotated mounting position 90 Xaxis 105900_en_01 PHOENIX CONTACT 16

TRIOPS2G/1AC/24DC/5 Rotated mounting position 180 Xaxis Rotated mounting position 270 Xaxis 105900_en_01 PHOENIX CONTACT 17

TRIOPS2G/1AC/24DC/5 Rotated mounting position 90 Zaxis Rotated mounting position 270 Zaxis 105900_en_01 PHOENIX CONTACT 18

TRIOPS2G/1AC/24DC/5 17 Operating modes 17.1 Series operation Two power supplies can be switched in series, to double the output voltage. For connection in series, only power supplies of the same performance class should be used. An output voltage of, for example, 48 V DC can be provided, if two 24 V power supplies are connected in series. Various voltage levels are made possible by varying the switching of the respective output voltage and the measurement reference point. I N Figure 21 I N Σ =I N Schematic diagram in parallel operation Figure 20 48 V 24 V 24 V 48 V Wiring principle, voltage levels with two power supplies 17.2 Parallel operation Devices of the same type can be connected in parallel to increase both redundancy and power. By default upon delivery, no further adjustments are required. If the output voltage is adjusted, a uniform distribution of power is guaranteed by setting all parallel operated power supply units to exactly the same output voltage. To ensure symmetrical current distribution we recommend that all cable connections from the power supply unit to the busbar are the same length and have the same cross section. Depending on the system, for parallel connection of more than two power supplies a protective circuit should be installed at each individual device output (e.g., decoupling diode, DC fuse or circuit breaker). This prevents high return currents in the event of a secondary device fault. 17.3 Redundant operation Redundant circuits are suitable for supplying systems which place particularly high demands on operational reliability. If a fault occurs in the primary circuit of the first power supply unit, the second device automatically takes over the complete power supply without interruption, and vice versa. For this purpose, the power supply units to be connected in parallel must be large enough to ensure that the total current requirements of all loads can be fully met by one power supply unit. External decoupling diodes or ORING modules are required for 100% redundancy. 17.3.1 Decoupling with diode module I N Figure 22 Σ =I N Schematic diagram, decoupling with diode module I N 105900_en_01 PHOENIX CONTACT 19

TRIOPS2G/1AC/24DC/5 17.3.2 Decoupling with ORING module I N I N Σ =I N Figure 23 Schematic diagram, decoupling with ORING module 17.4 Increasing power The output current can be increased to n x I N in the case of n parallel connected devices. Parallel connection for increasing power is used when extending existing systems. A parallel connection is recommended if the power supply unit does not cover the current consumption of the most powerful load. Otherwise, the load should be distributed between individual devices that are independent from one another. I N I N Figure 24 Σ =2xI N Schematic diagram of increased performance 105900_en_01 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 20 phoenixcontact.com