Product description Ecology Technical data Urbanline Euro Selekta Clad (selekta façade profiles and heritageselekta façade profiles) are identical in terms of their core material and surface texture. However, they are available with different surface coatings. The particle wood core consists of processed timber. We use exclusively untreated pulpwood in the form of wood shavings, thinning material and round timber from sustainable, domestic forestry. Imported timber is not used - especially from tropical climates. The binding agent used is a thermosetting artificial resin with building authority approval for outdoor use. s a wood preservative, we use an eco-friendly boron-based product with building authority approval that does not contain lindane or PCP. For the low flammability version, a mixture of boric acid and borax is used as a fire protection agent. No isocyanates, phosphates or halogens are added. Several layers of paper are impregnated with artificial resins for use as a coating. The surface and core are fused together without seams in a single process under the application of pressure and heat. Colorpan Base coating of paper impregnated with melamine resin, followed by coloured Colorpan surface coating using a pure, water-based acrylate. The pigments added are free of toxic heavy metals (no lead, chrome or cadmium). Dekopan Plus Multi-layer coating, printed or dyed; transparent, weatherresistant surface coating of the decor side. Rear side brown, no colour options. Technical data Values Unit Test specification. Density 800 90 kg/m EN. Flexural strength 0 N/mm EN 0. Elasticity modulus 000 000 N/mm EN 0. Tensile strength vertical to the surface.0.0 N/mm EN 9. Screw withdrawal strength ) 800 00 N WERZLIT TEST STNDRD. Swelling after storage after h 0. 0. % EN in water at 0 C after h.0.0 % EN. Moisture content 0 % EN 8. Temperature resistance under permanent load under temporary load 9. Fire behavior, class Standard version: B = normal flammability, special version B: low flammability Length change due to moisture/heat exposure ) -0 to +0 +0 C C WERZLIT TEST STNDRD B and B ) DIN 0 mm/m WERZLIT TEST STNDRD. Thermal conductivity λ 0 0.0 W/m K DIN. Water vapour permeability diffusion-equivalent air layer thickness m DIN. Cross-cut test ) GT 0 GT EN ISO 09. Scratch resistance 0.. N EN 8. Light fastness Level 8 DIN 00. Chemical resistance limited resistance EN 8. Cigarette burn resistance not resistant to burns as for EN 8 8. Colour deviation ) Δ E < DIN 0 9. Impact load impact resistant WERZLIT TEST STNDRD ) mm particle board screw, using a hole of mm diameter, 0 mm deep. ) Not available for all products, please ask for specific information. ) Maximum expected length change under extreme climate fluctuations. ) Gt 0 is the best, Gt is the worst value. ) With measurement geometry 0 /, standard illuminant C. v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
General information, Profile dimensions, Calculating the required quantity & Guidelines 0 0 Coverage widths + - Scope The scope of these installation instructions covers all installation variants of façade cladding, including soffits. 9 8 Calculating the required quantity (Calculation values exclude cutting waste) Required quantity/m Required quantity/m Coverage width Standard lengths Façade profile Façade screw. x 0, stainless steel Urbanline Euro Selekta Clad (Colorpan/Dekopan plus) at max. fastening spacing = mm (heritage-selekta) mm 00 mm. linear m 0. pcs. (selekta) mm 00 mm. linear m 0. pcs. Note! Top view The DIN requirements are presented here in The wood decors are equivalent to natural wood surfaces, meaning that different grain textures are possible within a single shipment (plain and/or mottled). Unfortunately, sorting at the factory is not possible! In order to obtain a uniform overall finish, we recommend considering this fact and, for example, laying out the façade profiles before starting with the installation. Wind side e d a simplified form as a general rule of thumb. Precise information on this topic must be taken from DIN 0, Part from March 00. The building dimensions are naturally Installation lengths View (cladding side) of primary importance for determining the size of area with increased For installation lengths of more than 00 mm, the profiles must wind suction (exterior be cut to a maximum length of 00 mm in order to minimise the expansion joints. Wind side B pressure coefficients). Sub-framework for façade cladding e/ d-e/ ccording to DIN 0, Part, the increased wind suction at the edge areas of the building walls must be considered when planning the sub-framework. The fastening spacing of the Urbanline Euro Selekta Clad (WERZLIT façade) profiles must be reduced to max. 00 mm in these areas; additional support battens must be provided as necessary. d Example: Wind side Cladding side rea with increased suction Batten spacing in area Normal area Batten spacing in area B e = m d = 8 m = e/ = m max. 00 mm B = d-e/ = m max. mm If two opposite main wind directions exist (e.g. west/east), area must naturally also be observed on the other side of the cladding wall. In the above example, area B would then only be m wide. Fire Protection see attached Fire Test Report v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Horizontal installation Sub-framework max.. Urbanline Euro Selekta Clad (UESC (Selekta / heritage-selekta façade profile). Façade screw. x 0, stainless steel. Support batten 0 mm x 0 mm, spacing max. mm. Fastening with screws x 0, stainless steel. Counter batten at least 0 mm x 0 mm. Dowel and screw with building authority approval. Insulation in two layers, pressure-resistant B - C Sections. UESC selekta / heritage-selekta façade profile. Back ventilation spacing at least 0 mm *) *) For selekta façade profiles in version B (low flammability) at least 0 mm. 00 - Important Building Design Notes: Sub-framework The supporting wall must be watertight and correct flashings used in the event of any water penetration i.e. severe storms There must be ventilation/ drainage at the base of the wall Install breathable sarking over the stud frame keeping all overlaps pointing downwards 0 mm and tape all joints Composite products expand B Horizontal section C Vertical section and contract with temperature longitudinally see installation instructions for joint options. v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Horizontal installation X Fastening spacing. UESC (selekta / heritage-selekta façade) profile max. 00 X. Façade screw. x 0, stainless steel. Punched holes. Support batten 0 mm x 0 mm X = or more supports, max. mm max. 00 X X = for only supports, max. 00 mm; Profile excess length max. 00 mm Fastening materials Fastening spacing B Sub-framework, alternative Use only screws. x 0, stainless steel. lways centre the screws in the punched fastening holes of the façade profile. B Sub-framework alternative 0 e. g. aluminium and wood sub-frameworks. Building wall. Thermal insulation. Support batten max. 0 0. U bracket lternatively, other sub-framework systems C Start of installation, alternative D Internal corner can also be used, such as for very thick insulation layers. C Start of installation from below. selekta / heritage-selekta façade profile. Starting profile T + G, aluminium. Starting profile P, aluminium (alternative) We recommend a max. 0 mm projection of the starting profile P. Ventilation profile, plastic D Internal corner. selekta / heritage-selekta façade profile. Jointing tape, plastic or suitable construction adhesive. luminium internal corner profile (lternative). Ventilation opening, continuous Please note: Baseboard termination t least 00 mm spacing to the floor. void designs that allow moisture build-up. v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Horizontal installation External corner. UESC (selekta / heritage-selekta façade profile). External corner C, aluminium (two-part). luminium external/internal corner profile (lternative). Cylinder sheet screw.9x, stainless steel The external corner C consists of lower 0. 0. profile and cover profile. The cover profile is clipped on after installation of the façade External Corner C Side Termination profile and secured to each profile bar in the upper area using cylinder sheet screws, pre-drilled to ø. mm. Please note: The luminium External/ Internal corner profile can be used in reverse for Internal corner applications at least 0mm B Side termination. UESC (selekta / heritage-selekta façade profile). Cover angle 0/0, aluminium D Connection to pitched roof. Sealing material. Connection profile F, aluminium C Roof connection. UESC (selekta / heritage-selekta façade profile). Edge trim profile, aluminium (alternative spacer bar, 9 mm). Ventilation profile, plastic. Ventilation opening, continuous. Roof tile v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Horizontal installation - B - C Window lintel connection. selekta / heritage-selekta façade profile Connection profile F, aluminium Z profile, aluminium External corner profile, plastic (Cut off lower leg) Ventilation profile, plastic Cladding panel (alternative) 8 0 Edge trim profile, aluminium 8 Ventilation opening, continuous Window lintel connection t the transition between the reveal and the lintel, the connection profiles F are given a mitre cut. 0 B The Z profile, aluminium, covers the vertical connection profile F. 0 C Window sill connection. selekta / heritage-selekta façade profile Ventilation profile, plastic Z profile, aluminium Outer window sill Ventilation opening, continuous 0 8 B Window lintel connection, alternative D Window reveal connection D Window reveal connection. selekta / heritage-selekta façade profile. Connection profile F, aluminium. Sealing material. luminium external corner profile. Outer window sill 0 mm approx. 0 mm C Window sill connection v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Horizontal Installation only for (selekta) UESC Profile butt joints The profiles can be installed in staggered arrangement or with a continuous vertical joint. Staggered arrangement. selekta façade profiles, cutting length. Install support battens in each joint area max. 00 mm Staggered arrangement max. D X Notching of the groove lip. Jointing tape, plastic Profile butt joint with butt connector max. 00 mm max. 00 mm When installing in a staggered arrangement, the expansion joints can be closed with butt connectors. Notch the groove lip on the back side of the façade profile. See images C to D B - C - D Butt connector / (for selekta façade profile ) Place the butt connector / on the lower façade profile and nail it to the support batten. Slide the notched façade profiles from both sides onto the butt connector, expansion joint 0 mm. B Butt connector / E Continuous profile butt joint. selekta façade profile. Butt connector /, plastic D Notching of the groove lip X = mm, for butt connector / 0 E - F Continuous vertical profile butt joint C Profile butt joint without butt connector F Cover profile T + G. selekta façade profile. Support batten, width at least 00 mm. Jointing tape, plastic. Cover profile T + G, aluminium. Pan head screw x 0, stainless steel Tip: Peg a mm wide batten to the sub-framework at the joint location. Position the façade profiles flush on both sides. fter installation of the façade profiles, remove the batten and screw on the cover profile T + G in its place. v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Horizontal installation only for (heritage-selekta) UESC Profile butt joints The profiles are installed in a staggered arrangement. There is no need to ensure an orderly joint arrangement. No battens are required under the joints. Staggered arrangement. heritage-selekta façade profile. No support batten is required in the joint area. Minimum length of the first profile: mm Staggered arrangement 8 v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
max. Installation Instructions: Urbanline Euro Selekta Clad Vertical installation only for UESC (selekta) 00 - Sub-framework. selekta façade profile. Façade screw. x 0, stainless steel. Support batten 0 mm x 0 mm, spacing max. mm. Fastening with screws x 0, stainless steel. Counter batten at least 0 mm x 80 mm, or at least 0 mm higher than second layer of thermal insulation. (See also note for B C, no. ). Dowel and screw with building authority approval. Insulation in two layers, pressure-resistant B - C Sections. selekta façade profile. Back ventilation spacing at least 0 mm*) *) For selekta façade profiles in version B (low flammability) at least 0 mm. Sub-framework 0 mm B Horizontal section C Vertical section 9 v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Vertical installation only for UESC (selekta) max. 00 max. 00 Fastening spacing. UESC (selekta façade profile) X X. Façade screw. x 0, stainless steel. Punched holes. Support batten 0 mm x 0 mm X = or more supports, max. mm X X = For only supports, max. 00 mm; profile excess length max. 00 mm Fastening materials Fastening spacing B Sub-framework, alternative Use only screws. x 0, stainless steel. lways centre the screws in the punched fastening holes of the façade profile. B Sub-frameworks alternatives at mind. least 0 mm. Building wall. Thermal insulation, two layers. Counter batten. U bracket C Start of installation D Connection to pitched roof. Support batten 0 mm x 0 mm lternatively, other sub-framework systems can also be used, such as for very thick insulation layers. D Connection to pitched roof. selekta façade profile C Start of installation from below. selekta façade profile. Layering profile, aluminium. Ventilation profile, plastic. Ventilation opening, continuous. Ventilation profile, plastic. Ventilation opening, continuous. Roof tile E Internal corner. selekta façade profile E Internal corner, alternative 0 Please note: Baseboard termination at least 00 mm spacing to the floor. void designs that allow moisture build-up.. Spacer bar, 9 mm. luminium internal corner profile. Jointing tape, plastic or suitable construction adhesive v.ul..9. 0 Phone 00 8 8 Email sales@urbanline.com.au
Vertical installation only for UESC (selekta) External corner. selekta façade profile. Spacer bar, 9 mm. External corner C (two-part), aluminium. luminium external/internal corner profile. Cylinder sheet screw.9 x, stainless steel The external corner C consists of lower profile and cover profile. The cover profile is clipped on after installation of the façade profile and secured to each profile bar in the upper area using cylinder sheet screws, pre-drilled to ø. mm. 0.. 0 Please note: The luminium External/Internal corner profile can be used in reverse for Internal corner applications External corner, alternative B Connection to side in niche. selekta façade profile. Spacer bar, mm. Cover angle 0/0, aluminium. Sealing material, e. g. Compriband 0 B Connection to side in niche v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Vertical installation only for UESC(selekta) - B - C Window lintel connection. selekta façade profile. Connection profile F, aluminium. Z profile, aluminium. External corner profile, plastic (cut off lower leg). Ventilation profile, plastic 0. Edge trim profile, aluminium Spacer bar, 9 mm (alternative to ). Ventilation opening, continuous Window lintel connection t the transition between the reveal and the lintel, the connection profiles F are given a mitre cut. 0 B The Z profile, aluminium, covers the vertical connection profile F. 0 C Window sill connection. selekta façade profile. Ventilation profile, plastic. Outer window sill. Z profile, aluminium. Ventilation opening, continuous B Window lintel connection, alternative D Window reveal connection D Window reveal connection. selekta façade profile. Connection profile F, aluminium. Spacer bar 9 mm. luminium external corner profile, alternative external corner C, aluminium. Sealing material, e. g. Compriband. Edge trim profile, aluminium C Window sill connection 0 mm approx. 0 mm. Outer window sill v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
Installation Instructions: Urbanline Euro Selekta Clad 0 0 Butt joints and diagonal installation - B Vertical installation, continuous. selekta façade profile Install support battens 0 mm x 0 mm in each joint area Jointing tape, plastic 00 - X = max. Vertical installation B Continuous horizontal butt joint Z profile or, aluminium, maintain a 0 mm expansion joint at top and bottom C - D Vertical / horizontal installation, continuous horizontal butt joint The sub-framework must be modified at C Vertical / horizontal installation D Continuous horizontal butt joint the butt joint according to the installation direction. E Vertical / horizontal installation F Continuous vertical butt joint *) For selekta façade profiles in version B (low flammability) at least G Diagonal 0 mm! installation Note: Position the vertical support battens at the transition point at least mm above the horizontal counter batten to ensure back ventilation*).. selekta façade profile Support battens 0 mm x 0 mm Jointing tape, plastic Z profile or, aluminium, maintain 0 mm gap at top and bottom L Back ventilation spacing at least 0 mm *) E - F Vertical / horizontal installation, continuous vertical butt joint. selekta façade profile. Support batten, width at least 00 mm. Jointing tape, plastic. Cover profile T + G, aluminium. Pan head screw x 0, stainless steel Vertical installation B Continuous horizontal butt joint profiles, remove the batten and screw 9 G Diagonal installation, X = max. a Tip: Peg a mm wide batten to the sub-framework at the joint location. L Position the façade profiles flush on both sides. fter installation of the façade 8 depending on thermal insulation + 0 mm for back ventilation spacing 0 0 Vertical installation B Continuous horizontal butt joint 00 -- 0 0 C Vertical / horizontal installation D Continuous horizontal butt joint X = max. max. E Vertical / horizontal installation F Continuou E Vertical / horizontal installation F Continuous vertical butt joint G Diagonal installation G Diagonal installation on the cover profile T + G in its place. G Diagonal installation sub-framework. selekta façade profile. Counter batten, cross-section (see also note for C D, no. ). pproved dowel incl. stainless steel screw. Support batten 0 mm x 0 mm. Fastening with screws x 0, stainless steel. Façade screw. x 0, stainless steel. Layering profile, aluminium, see also page 8 8. Façade profile end pieces, fasten with at least screws 9. Install corresponding battens Vertical installation B Continuou Vertical installation B Continuous horizontal butt joint X = max. max. a C Vertical / horizontal installation D Continuou L 00 - C Vertical / horizontal installation D Continuous horizontal butt joint L Support batten spacing = BS Fastening spacing = X (measure parallel to the façade profile) The spacing of the support battens BS depends on the selected installation angle α and the fastening spacing X X = or more supports, max. mm X = For only supports, max. 00 mm Examples: 00 - E Vertical / horizontal installation F Continuous vertical butt joint X = max. X = max. 0 0 0 9 8 8 X = max. Installation angle α 0 max. mm max. mm BS = or more supports 0 0 BS = For only supports 0 0 a 0 0 0 v.ul..9. 9 X = max. Phone 00 8 8 Email sales@urbanline.com.au
Soffits - B Soffit, installed lengthwise. Universal angle selekta / heritage-selekta façade profile Spacer bar 9 mm Ventilation profile 0 lternative edge trim profile Roof tile 0 C Soffit, installed crosswise Verge section, soffit installed lengthwise B Wall connection, alternative. Cover angle 0/0, aluminium 8. Sealing material 9. Ventilation opening, continuous 0. Starting profile P 9 at least 0 0 0 8 C Verge section, soffit installed crosswise v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au
General guidelines rguments for a back-ventilated curtain cladding of the exterior wall Energy savings Weather protection ttractive design Increased building value Handling The selekta façade profiles must be stored in their packaging, lying flat and dry until use. Sawing with power tools Hard metal saw blade, high number of teeth, (tooth pitch approx. 0 mm), saw blade with alternate top bevel or hollow-tooth flat-top teeth. Sawing with hand saws well-sharpened and dressed saw with small teeth is sufficient. Fastening the façade profiles Only with WERZLIT façade screws. x 0, stain- less steel. Centre the fastening screws through the existing punched holes. The screws may only be screwed in until the screw head rests against the surface. Fastening of all connection profiles Only with WERZLIT façade screws. x 0, stainless steel. Please note: Heavy structures, such as an awning, climbing trellis, etc., may not be fastened directly to the cladding or its sub-framework. Provide separate sub-frameworks. Sub-framework Façade profiles are typically fastened to a wood sub-framework. In principle, the following guidelines should be followed for wood sub-frameworks: a) The wood must correspond to grade S0 (or MS0) according to DIN 0. b) The individual cross-section must be selected according to DIN 0, Part. c) The wood must be protected according to DIN 8800, wood preservation. d) The sub-framework must be fastened using dowels and screws with building authority approval and in accordance with the instructions of the manufacturer. e) The support battens must be fastened to the counter battens with at least wood screws, stainless steel, per intersection, in a diagonal arrangement. f) The sub-framework must be level and plumb. Dimensional tolerances can be found in DIN 80 Part and Part. g) ll Structural framework must be in accordance to ustralian Building Standards & Local Building Codes. Thermal insulation The thermal insulation must be dimensioned according to the current German energy conservation regulations (EnEV). The thermal insulation material must be fastened with appropriate hardware, such as insulation pins, in accordance with the instructions of the manufacturer. The installation must be made windproof to prevent cold air from flowing behind it. We therefore recommend installing in two layers with overlapping joints. The insulation must be flush against the wall. Back ventilation The back ventilation spacing must be at least 0 mm *). Expansion The length change of the façade profiles is approx. mm/linear m, depending on moisture and temperature. Expansion joints of 0 mm must be maintained at profile butt joints and profile connections. Sealing cut edges Cut edges must be sealed free of pores with Werzalit edge sealant. Exception: Sufficiently covered cut edges under the roof overhang. *) For selekta façade profiles in version B (low flammability) at least 0 mm. The back ventilation cross-section may not be regularly diminished by battens or other objects. The ventilation inlets and outlets must have consistent widths of at least 0 mm. If you have additional questions, please contact Urbanline rchitectural 00 8 8. Subject to changes due to technical improvements. v.ul..9. Phone 00 8 8 Email sales@urbanline.com.au