* TURNING SPACE ROLLED CURB SIDEWALK RAMP TYPE R (ROLLED SIDES) * TURNING SPACE ** RAMP

Similar documents
STANDARD CONSTRUCTION DETAILS PAVING REVISED -MAY 2017 DEPARTMENT OF ENGINEERING

S.R. 32 AT GRADE CROSSING

UNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2017 REVISIONS

From Off-The-Shelf to Market-Ready New Age Enclosures is your Single Source Solution. Let us quote modifiying our Stock Enclosures to meet your

Sample Plan RETAINING WALL DETAILS NARRATIVE. Sample Plan RETAINING WALL DETAILS CHECKLIST

From Off-The-Shelf to Market-Ready New Age Enclosures is your Single Source Solution. Let us quote modifiying our Stock Enclosures to meet your

GENERAL NOTES 1600 SYSTEM NOTES STRUCTURAL SEAL NOTES 1 - HANDLING, STORING AND PROTECTING ALUMINUM MATERIAL. 2 - GENERAL RULES

GEOTEXTILE FABRIC, 36 IN. WIDE TIRE COMPACTION ZONE MACHINE SLICE 8 IN IN. DEPTH SILT FENCE TYPE MS (MACHINE SLICED)

4. Current Standard Plates including Transmittal Letters are available on the web at:

PLEASANT VALLEY ROAD REHABILITATION 37 AVENUE TO 41 AVENUE FOR CONSTRUCTION ENG

PIER 35 ½ N Penn Street, Philadelphia, Pa SHOVEL READY PROJECTS

CONSTRUCTION PLANS FOR

Ultimate Trilennium Astragal Prehanger Installation Instructions

Series Door with In-Line Panel (GIH / AHD)

4. Current Standard Plans including Transmittal Letters are available on the web at:

Harmer Roof Drainage The Modulock Raised Deck Support Ranges

ARK CHEVRON INSTALLATION GUIDE

Joanna Towler, Roading Engineer, Professional Services, NZTA National Office Dave Bates, Operations Manager, NZTA National Office

TUR DOORS SHOWER DOORS

* * 33/3549A CS 33/3549A. 2-Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2015

Extremely small "footprint" and the highest circuit density available AK550. Front Wire Entry

NORTH STAR 2-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS

670 Freestyle/Style Door with In-Line Panel

RemoteTeller SYSTEM - RTS VAT 21 GX CUSTOMER UNIT COMPONENTS CUSTOM DESIGNED CUSTOMER AREA

Crime Scene Documentation. Crime Scene Documentation. Taking the C.S. What should my notes include. Note Taking 9/26/2013

Multi-Point Astragal Prehanger Installation Instructions

Canopy Bed Frame. Date: 8 Jun 15 www. potterybarn.com Page 1 of 12 Rev:

TP Series - Triple PV Top of Pole Solar LED Lighting System

Section 100 Street Sections

UPTOWN CANOPY FRAME T/F/Q

General Instructions 03HEL1010DDFW-V3. Please retain product label and instructions for future reference. 10x10 Helios Summer House

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007

Exercise 1-1. The Sine Wave EXERCISE OBJECTIVE DISCUSSION OUTLINE. Relationship between a rotating phasor and a sine wave DISCUSSION

SOUTH HAVEN FISHING PLATFORM AND BANK STABILIZATION DNR #

Fitting & User Instructions

Please Do Not Return Product to Store!

NORTH STAR 4-PANEL PATIO DOOR ASSEMBLY INSTRUCTIONS

Project: NEW CONCESSIONS/ TOILET BUILDINGS FOR FLOMATON HIGH SCHOOL FOR THE ESCAMBIA COUNTY BOARD OF EDUCATION BREWTON, ALABAMA

ModWood New Zealand Technical and Installation Guide

Job Sheet 2. Variable Speed Drive Operation OBJECTIVE PROCEDURE. To install and operate a Variable Speed Drive.

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Version (See back cover)

CHAPTER 2 LITERATURE STUDY

FOR DEVICES SOLD PRIOR TO

NOTE THAT THE HANDLE IS BELOW THE LOCK BASE

METHOD OF LOCATION USING SIGNALS OF UNKNOWN ORIGIN. Inventor: Brian L. Baskin

Rectangular type APS-10 to 15 Series

How to remove BRNS/BRFS series from a PWB

First Round Solutions Grades 4, 5, and 6

SOLVING TRIANGLES USING THE SINE AND COSINE RULES

STATEMENT OF ESTIMATED QUANTITIES SHEET C.S.A.H HENNEPIN AVE HENNEPIN COUNTY PROJECT 1755 SHEET 1 OF 1 3/15/2018

Version (See back cover)

Steel Stud Systems 1800 STUDCO. Studco Stud Fits positively into track. External Infill Framing Between concrete and steel structures

DELINEATOR REFERENCE POINT 200' TYPICAL SPACING (YELLOW DELINEATORS) END OF MERGE LANE TAPER DELINEATOR REFERENCE POINT

Lecture 20. Intro to line integrals. Dan Nichols MATH 233, Spring 2018 University of Massachusetts.

FATIGUE BEHAVIOUR OF COMPOSITE JOINTS WITH HEXAGON BOLTS

* * 98/9949 CS 98/ Point Latch includes these additional parts. 1-Point Latch (LBL) Customer Service. Installation Instructions

Options. Exposed Ends (EXP) Flush Ends (FL) Flush Unexposed Ends (FUE) Cabinet Systems Winter

ABB STOTZ-KONTAKT. ABB i-bus EIB Current Module SM/S Intelligent Installation Systems. User Manual SM/S In = 16 A AC Un = 230 V AC

A Development of Earthing-Resistance-Estimation Instrument

Description: SM-BGA socket for BGA223 19x15 array 0.5mm pitch 8mm x 10mm x 1.2mm DUT

Effect of High-speed Milling tool path strategies on the surface roughness of Stavax ESR mold insert machining

Floor Area Ratio. Note: Handicap parking is provided in accordance with ADA standards. SITE DATA FIRE LANE STRIPING FIRE HYDRANT PARKING COUNT

WETROOM WALK-IN AWL1500 AWL1200 AWL900 AWC850

OVERHEAD TRUSS REPLACEMENT

Unirac Code-Compliant Installation Manual

Version (See back cover)

WINDY HILL PROPERTY VENTURES

Translate and Classify Conic Sections

ITEM SPECIAL - NOISE BARRIERS GENERAL

Design and Modeling of Substrate Integrated Waveguide based Antenna to Study the Effect of Different Dielectric Materials

NOTE: UNLESS OTHERWISE SPECIFIED. 1. SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING

APPLICATION MANUAL. application manual >> ARMA-CHEK R. application manual

MODEL 351 POWERGLIDE SERIES INSTRUCTIONS FOR INSTALLING SARGENT DOOR CLOSERS WITH "H" HOLDER ARMS

T6-200 THERMAL IMAGING SYSTEM

MATKI ONE MOWP - WETROOM PANEL & BRACE BAR MOWV - WETROOM PANEL & CEILING BAR

Ultimate Flip Lever Astragal Prehanger Installation Instructions

Array chip resistors size ARC241/ARC242 ARV241/ARV242

MAXIMUM FLOWS IN FUZZY NETWORKS WITH FUNNEL-SHAPED NODES

HX-80N/80NAM. High Mount Outdoor Detector

INTRODUCTION TO TRIGONOMETRY AND ITS APPLICATIONS

Products no longer available

REVIEW, pages

Module 9. DC Machines. Version 2 EE IIT, Kharagpur

PLANNING & LAYOUT BENCH

Aquauno Select MINUTES. (duration) FREQUENCY LED. OFF 8h AQUAUNO SELECT 5 MIN FREQUENCY. the timer is being programmed;

Pro-Master Ridge Vent Enabling Attic Air to Exit. Moist, Hot Attic Air. Cool, Fresh Air Enters Through Soffit Vents

Ultimate Push Button Astragal Prehanger Installation Instructions

LIST OF ARCHITECTURE PLANS

The Cottage Beach Design

CAL. NX15 DUO-DISPLAY QUARTZ

NEW RETAIL BUILDING 7400 AMADOR VALLEY BOULEVARD DUBLIN CALIFORNIA Beaumont + Associates NEW RETAIL BUILDING PARCEL MAP PROJECT DATA

The Discussion of this exercise covers the following points:

NOTE: UNLESS OTHERWISE SPECIFIED. 1. SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING

NOTE: UNLESS OTHERWISE SPECIFIED. 1. SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING

Large Commercial Trunking

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2015

Kyushu Institute of Technology

NOTES 3D VIEW OF RAILING WITH TYPE 1 - PICKET INFILL PANEL. (42" Height shown, 54" Height Similar) TABLE 1 - RAILING MEMBERS ALTERNATIVE BOTTOM &

Transcription:

* MXIMUM TURNING SPCE IS 2.0% IN ECH DIRECTION OF TRVEL. MINIMUM DIMENSIONS 5' x 5'. SEE NOTES. ** MXIMUM RMP CROSS IS 2.0%, RUNNING 5% - 7% (8.3% MXIMUM). SEE NOTES. "NON-WLKING" RE * TURNING SPCE 24" CROSS FULL WIDTH PERMNENT OBSTRUCTION RMP TYPE R (ROLLED SIDES) * TURNING SPCE 24" CROSS FULL WIDTH 24" CROSS FULL WIDTH SIDE FLRE 10% MX. SIDE FLRE 10% MX. 10% MX. SIDE FLRE SIDE FLRE 10% MX. FULL CURB HEIGHT MY BE REDUCED TO CCOMMODTE MXIMUM SIDE FLRE RMP TYPE F (FLRED SIDES, TWO RMPS SHOWN) DEPRTMENT DIRECTOR Kirk T. Steudle MICHIGN DEPRTMENT OF TRNSPORTTION BUREU OF HIGHWY DEVELOPMENT STNDRD PLN FOR Michigan Department of Transportation PREPRED BY PPROVED BY: DIRECTOR, BUREU OF FIELD SERVICES RMP ND DETECTBLE WRNING DETILS DESIGN DIVISION DRWN BY: B.L.T. PPROVED BY: W.K.P. CHECKED BY: 1 OF 7 DIRECTOR, BUREU OF HIGHWY DEVELOPMENT F.H.W.. PPROVL PLN DTE

* MXIMUM TURNING SPCE IS 2.0% IN ECH DIRECTION OF TRVEL. MINIMUM DIMENSIONS 5' x 5'. SEE NOTES. ** MXIMUM RMP CROSS IS 2.0%, RUNNING 5% - 7% (8.3% MXIMUM). SEE NOTES. * TURNING SPCE "NON-WLKING" RE 24" CROSS FULL WIDTH WLKING RE SIDE FLRE 10% MX. RMP TYPE RF (ROLLED / FLRED SIDES) PVEMENT CURB & GUTTER RMP * TURNING SPCE 2" MX. 24" CROSS FULL WIDTH RMP 5% - 7% (8.3% MXIMUM) SEE NOTES 1" EXPNSION JOINT RMP ND TURNING SPCE SLB THICKNESSES SHLL BE S CLLED FOR ON THE PLNS REINFORCEMENT S IN DJCENT CURB & GUTTER GRDE BREK SECTION - PVEMENT SHLL END FLUSH WITH THE GUTTER PN *** TRNSITION DJCENT GUTTER PN CROSS SECTION TO PROVIDE 5.0% MXIMUM COUNTER CROSS THE RMP OPENING. RMP RMP SHLL END FLUSH WITH BCK OF CURB *** 5.0% MX. SECTION THROUGH CURB CUT (TYPICL LL RMP TYPES) MICHIGN DEPRTMENT OF TRNSPORTTION BUREU OF HIGHWY DEVELOPMENT STNDRD PLN FOR RMP ND DETECTBLE WRNING DETILS F.H.W.. PPROVL PLN DTE 2 OF 7

* MXIMUM TURNING SPCE IS 2.0% IN ECH DIRECTION OF TRVEL. MINIMUM DIMENSIONS 5' x 5'. SEE NOTES. "NON-WLKING" RE ** MXIMUM RMP CROSS IS 2.0%, RUNNING 5% - 7% (8.3% MXIMUM). SEE NOTES. * TURNING SPCE 24" CROSS FULL WIDTH RMP TYPE P (PRLLEL RMP) DO NOT USE IN RES WHERE PONDING MY OCCUR "NON-WLKING" RE "NON-WLKING" RE * TURNING SPCE 24" CROSS FULL WIDTH RMP TYPE C (COMBINTION RMP) USE 24" DEEP DETECTBLE WRNINGS IF MEDIN WIDTH IS T LEST 6'-0". OTHERWISE NO DETECTBLE WRNING IS REQUIRED. MEDIN WIDTH RMP TYPE M (MEDIN ISLND) MICHIGN DEPRTMENT OF TRNSPORTTION BUREU OF HIGHWY DEVELOPMENT STNDRD PLN FOR RMP ND DETECTBLE WRNING DETILS F.H.W.. PPROVL PLN DTE 3 OF 7

* MXIMUM TURNING SPCE IS 2.0% IN ECH DIRECTION OF TRVEL. MINIMUM DIMENSIONS 5' x 5'. SEE NOTES. ** MXIMUM RMP CROSS IS 2.0%, RUNNING 5% - 7% (8.3% MXIMUM). SEE NOTES. "NON-WLKING" RE * TURNING SPCE 24" 2" MXIMUM DETECTBLE WRNING BORDER OFFSET MESURED FROM THE ENDS OF THE RDIUS. SEE NOTES ( RDIL DETECTBLE WRNING SHOWN ) "NON-WLKING" RE * TURNING SPCE 24" 2" MXIMUM DETECTBLE WRNING BORDER OFFSET MESURED FROM THE ENDS OF THE RDIUS. SEE NOTES ( TNGENT DETECTBLE WRNING SHOWN ) RMP TYPE D (DEPRESSED CORNER) USE ONLY WHEN INDEPENDENT DIRECTIONL RMPS CN NOT BE CONSTRUCTED FOR ECH CROSSING DIRECTION MICHIGN DEPRTMENT OF TRNSPORTTION BUREU OF HIGHWY DEVELOPMENT STNDRD PLN FOR RMP ND DETECTBLE WRNING DETILS F.H.W.. PPROVL PLN DTE 4 OF 7

* THE SHLL BE LOCTED SO THT THE EDGE NEREST THE RIL CROSSING IS 6' MINIMUM ND 15' MXIMUM FROM THE CENTERLINE OF THE NEREST RIL. DO NOT PLCE DETECTBLE WRNING ON RILROD CROSSING MTERIL. (TYP.) 24" CROSS FULL WIDTH 6' MIN.* 15' MX.* RILROD CROSSING MTERIL (TYP.) PEDESTRIN GTE (WHERE PROVIDED) 24" CROSS FULL WIDTH DETECTBLE WRNING T RILROD CROSSING NEREST EDGE WITHIN 2" OF SHOULDER 24" CROSS FULL WIDTH SHOULDER DETECTBLE WRNING T FLUSH SHOULDER OR RODWY MICHIGN DEPRTMENT OF TRNSPORTTION BUREU OF HIGHWY DEVELOPMENT STNDRD PLN FOR RMP ND DETECTBLE WRNING DETILS F.H.W.. PPROVL PLN DTE 5 OF 7

LEGEND D SURFCE * GRDE BREK DETECTBLE WRNING 5' 5.0% MX. RUNNING BEYOND BOTTOM GRDE BREK. SEE SECTION B-B "NON-WLKING" RE WHERE EITHER END OF THE BOTTOM GRDE BREK IS MORE THN 5' FROM THE BCK OF CURB, THE DETECTBLE WRNING SHLL BE LOCTED T THE BCK OF CURB. (DOME ORIENTTION IS NOT SIGNIFICNT ON RDIUS) RMP LOCTED IN RDIUS (TYPE R SHOWN) (GRDE BREK GRETER THN 5') RMP PERPENDICULR TO RDIL CURB (TYPE F SHOWN) USE WITH RDIL CURB WHEN THE CROSSWLK ND ( RMP RE NOT LIGNED ) CROSSWLK MRKING PREFERRED LOCTION OF DRINGE INLET (TYP.) LTERNTE LOCTION OF DRINGE INLET (TYP.) B RMP PERPENDICULR TO TNGENT CURB (TYPE F ND TYPE RF SHOWN) WHERE BOTH ENDS OF THE BOTTOM GRDE BREK RE WITHIN 5' OF THE BCK OF CURB, THE DETECTBLE WRNING SHLL BE LOCTED B ON THE RMP SURFCE T * GRDE BREK (TYP) THE BOTTOM GRDE BREK. 2% (5.0% MX.) BEYOND BOTTOM GRDE BREK RMP LOCTED IN RDIUS (TYPE R SHOWN) (GRDE BREK LESS THN 5') PVEMENT CURB & GUTTER RMP * GRDE BREK RMP 5% - 7% (8.3% MXIMUM) SEE NOTES * GRDE BREKS T THE TOP ND BOTTOM OF CURB RMPS SHLL BE PERPENDICULR TO THE DIRECTION OF TRVEL. *** 5.0% MX. 2% (5.0% MX.) *** TRNSITION DJCENT GUTTER PN CROSS SECTION TO PROVIDE 5.0% MXIMUM COUNTER CROSS THE RMP OPENING. 1" EXPNSION JOINT PPROCH RE SHLL END FLUSH WITH BCK OF CURB SECTION B-B RMP ORIENTTION RMP ND TURNING SPCE SLB THICKNESSES SHLL BE S CLLED FOR ON THE PLNS 24" DEEP DETECTBLE WRNING, EXTENDING THE WIDTH OF THE RMP. MICHIGN DEPRTMENT OF TRNSPORTTION BUREU OF HIGHWY DEVELOPMENT STNDRD PLN FOR RMP ND DETECTBLE WRNING DETILS F.H.W.. PPROVL PLN DTE 6 OF 7

50% TO 65% OF BSE 0.2" 1.6" - 2.4" 1.6" - 2.4" LIGNED IN DIRECTION OF TRVEL ND PERPENDICULR (OR RDIL) TO GRDE BREK 0.9" TO 1.4" 0.65" MIN. 24" DOME SECTION 0.65" MIN. DOME SPCING DOME LIGNMENT DETECTBLE WRNING DETILS NOTES: DETILS SPECIFIED ON THIS PLN PPLY TO LL CONSTRUCTION, RECONSTRUCTION, OR LTERTION OF STREETS, CURBS, OR S IN THE PUBLIC RIGHT OF WY. RMPS RE TO BE LOCTED S SPECIFIED ON THE PLNS OR S DIRECTED BY THE ENGINEER. RMPS SHLL BE PROVIDED T LL CORNERS OF N INTERSECTION WHERE THERE IS EXISTING OR PROPOSED ND CURB. RMPS SHLL LSO BE PROVIDED T MRKED ND/OR SIGNLIZED MID-BLOCK CROSSINGS. SURFCE TEXTURE OF THE RMP SHLL BE THT OBTINED BY CORSE BROOMING, TRNSVERSE TO THE RUNNING. SHLL BE RMPED WHERE THE DRIVEWY CURB IS EXTENDED CROSS THE WLK. CRE SHLL BE TKEN TO SSURE UNIFORM GRDE ON THE RMP. WHERE CONDITIONS PERMIT, IT IS DESIRBLE THT THE OF THE RMP BE IN ONLY ONE DIRECTION, PRLLEL TO THE DIRECTION OF TRVEL. RMP WIDTH SHLL BE INCRESED, IF NECESSRY, TO CCOMMODTE SNOW REMOVL EQUIPMENT NORMLLY USED BY THE MUNICIPLITY. FOR NEW RODWY CONSTRUCTION, THE RMP CROSS MY NOT EXCEED 2.0%. FOR LTERTIONS TO EXISTING RODWYS, THE CROSS MY BE TRNSITIONED TO MEET N EXISTING RODWY GRDE. THE CROSS TRNSITION SHLL BE PPLIED UNIFORMLY OVER THE FULL LENGTH OF THE RMP. THE MXIMUM RUNNING OF 8.3% IS RELTIVE TO FLT (0%) REFERENCE. HOWEVER, IT SHLL NOT REQUIRE NY RMP OR SERIES OF RMPS TO EXCEED 15 FEET IN LENGTH. DRINGE STRUCTURES SHOULD NOT BE PLCED IN LINE WITH RMPS. THE LOCTION OF THE RMP SHOULD TKE PRECEDENCE OVER THE LOCTION OF THE DRINGE STRUCTURE. WHERE EXISTING DRINGE STRUCTURES RE LOCTED IN THE RMP PTH OF TRVEL, USE MNUFCTURER'S D COMPLINT GRTE. OPENINGS SHLL NOT BE GRETER THN ". ELONGTED OPENINGS SHLL BE PLCED SO THT THE LONG DIMENSION IS PERPENDICULR TO THE DOMINNT DIRECTION OF TRVEL. TRNSITION THE GUTTER PN CROSS SECTION SUCH THT THE COUNTER IN THE DIRECTION OF RMP TRVEL IS NOT GRETER THN 5.0%. MINTIN THE NORML GUTTER PN CROSS SECTION CROSS DRINGE STRUCTURES. THE TOP OF THE JOINT FILLER FOR LL RMP TYPES SHLL BE FLUSH WITH THE DJCENT CONCRETE. PROVIDE TURNING SPCES WHERE PEDESTRIN TURNING MOVEMENTS RE REQUIRED. WHEN 5' MINIMUM WIDTHS RE NOT FESIBLE, RMP WIDTH MY BE REDUCED TO NOT LESS THN 4' ND TURNING SPCES TO NOT LESS THN 4' x 4'. COVERGE IS 24" MINIMUM IN THE DIRECTION OF RMP/PTH TRVEL ND THE FULL WIDTH OF THE RMP/PTH OPENING EXCLUDING CURBED OR FLRED CURB TRNSITION RES. BORDER OFFSET NOT GRETER THN 2" MESURED LONG THE EDGES OF THE DETECTBLE WRNING IS LLOWBLE. FOR RDIL CURB THE OFFSET IS MESURED FROM THE ENDS OF THE RDIUS. CROSSWLK ND STOP LINE MRKINGS, IF USED, SHLL BE SO LOCTED S TO STOP TRFFIC SHORT OF RMP CROSSINGS. SPECIFIC DETILS FOR MRKING PPLICTIONS RE GIVEN IN THE "MICHIGN MNUL OF UNIFORM TRFFIC CONTROL DEVICES". FLRED SIDES WITH OF 10% MXIMUM, MESURED LONG THE RODSIDE CURB LINE, SHLL BE PROVIDED WHERE N UNOBSTRUCTED CIRCULTION PTH LTERLLY CROSSES THE RMP. FLRED SIDES RE NOT REQUIRED WHERE THE RMP IS BORDERED BY LNDSCPING, UNPVED SURFCE OR PERMNENT FIXED OBJECTS. WHERE THEY RE NOT REQUIRED, FLRED SIDES CN BE CONSIDERED IN ORDER TO VOID SHRP CURB RETURNS T RMP OPENINGS. DETECTBLE WRNING PLTES MUST BE INSTLLED USING FBRICTED OR FIELD CUT UNITS CST ND/OR NCHORED IN THE PVEMENT TO RESIST SHIFTING OR HEVING. MICHIGN DEPRTMENT OF TRNSPORTTION BUREU OF HIGHWY DEVELOPMENT STNDRD PLN FOR RMP ND DETECTBLE WRNING DETILS F.H.W.. PPROVL PLN DTE 7 OF 7