Get started with DSO-X 2014A

Similar documents
ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Faculty of Engineering, Thammasat University

LAB I. INTRODUCTION TO LAB EQUIPMENT

54645D. Mixed Signal Oscilloscope

Experiment 9 The Oscilloscope and Function Generator

Appendix A: Specifications

Laboratory 1 Generating and viewing signals rev. 20e. Oscilloscope Settings

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

Notes on Experiment #1

UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering. ECE 2A & 2B Laboratory Equipment Information

Lab #5 Steady State Power Analysis

Combinational logic: Breadboard adders

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

HP 16533A 1-GSa/s and HP 16534A 2-GSa/s Digitizing Oscilloscope

Lab #1 Lab Introduction

EXPERIMENT 2 DIGITAL STORAGE OSCILLOSCOPE

Oscilloscope and Function Generators

EENG-201 Experiment # 4: Function Generator, Oscilloscope

Introduction to Oscilloscopes Instructor s Guide

A semester of Experiments for ECE 225

AP034-OM-E Rev D ISSUED: January 2000 ²

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

ECE65 Introduction to the Function Generator and the Oscilloscope Created by: Eldridge Alcantara (Spring 2007)

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

Specifications for DS1000CA Series

Agilent N2740A Education Training Kit for 1000 Series Oscilloscopes

Measurement Bench. Accessories. Power supply. Wave form generator. Multimetre. Oscilloscope. Dr. L.Scucchia

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

DSOXEDK Educator s Oscilloscope Training Kit. Lab Guide and Tutorial for Agilent 4000 X-Series Oscilloscopes

LAB II. INTRODUCTION TO LAB EQUIPMENT

Agilent Technologies 3000 Series Oscilloscopes

DIGITAL STORAGE OSCILLOSCOPES

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

Oscilloscope Fundamentals. For Electrical Engineering and Physics Undergraduate Students

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

DEPARTMENT OF INFORMATION ENGINEERING. Test No. 1. Introduction to Scope Measurements. 1. Correction. Term Correction. Term...

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

HP-3310B 20M Colored Handheld Oscilloscope

LAB I. INTRODUCTION TO LAB EQUIPMENT

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

University of Utah Electrical & Computer Engineering Department ECE 2210/2200 Lab 4 Oscilloscope

Agilent Technologies 3000 Series Oscilloscopes

DSO 3000 Series Oscilloscope

2 Oscilloscope Familiarization

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

U1604A Handheld Oscilloscopes, 40 MHz

A Few Words about Pulse Width Modulation. The Rigol DG2041A, DG4000, and DG5000 Series of Arbitrary Waveform Generators support PWM.

CPE 310L EMBEDDED SYSTEM DESIGN LABORATORY

Laboratory Equipment Instruction Manual 2011

Agilent Technologies 3000 Series Oscilloscopes

DSOXEDK Educator s Oscilloscope Training Kit

OSCILLOSCOPES. Oscilloscopes CS-5400 SERIES CS-5400/5450 FEATURES OUTLINE CS-5400

Electric Circuit II Lab Manual Session #1

Supplement. TDS5032 and TDS5034 Digital Phosphor Oscilloscopes

EC310 Security Exercise 20

L107 Lab. LAB basic HW Tools. Manual PS E3630A. E9340A LogicWave PC Logic Analyzer

2 Operation. Operation. Getting Started

Lab 3: RC Circuits. Construct circuit 2 in EveryCircuit. Set values for the capacitor and resistor to match those in figure 2 and set the frequency to

Test ID 5-15 Utility Line Impedance Test Procedures Guide

EE EXPERIMENT 1 (2 DAYS) BASIC OSCILLOSCOPE OPERATIONS INTRODUCTION DAY 1

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

/ Digital Oscilloscope

AE Agricultural Customer Services Play-by-Play Tekscope Manual

Agilent InfiniiVision 4000 X-Series Oscilloscopes. Service Guide

Introduction to Lab Instruments

Help Volume Agilent Technologies. All rights reserved. Instrument: Agilent Technologies 16533/34A Digitizing Oscilloscope

GDS MHz Handheld Digital Oscilloscope New Product Announcement

Sirindhorn International Institute of Technology Thammasat University at Rangsit

Specifications. Specifications and Characteristics Specifications

Digital 20MHz and 60MHz Oscilloscopes

Performance Characteristics

Parts to be supplied by the student: Breadboard and wires IRLZ34N N-channel enhancement-mode power MOSFET transistor

FLORIDA INTERNATIONAL UNIVERSITY ELECTRICAL & COMPUTER ENGINEERING LAB INSTRUMENTS USER MANUAL

Agilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet

Agilent 81133A/81134A

WaveAce 1000 and 2000 Oscilloscopes

DIGITAL STORAGE OSCILLOSCOPES

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment:

AC Measurements with the Agilent 54622D Oscilloscope

Agilent 33522A Function Arbitrary Waveform Generator. Tektronix TDS 3012B Oscilloscope

Procedures Guide. Tektronix. HDMI Sink Instruments Differential Impedance Measurement

Agilent 1000 Series Oscilloscopes. User s Guide

Agilent 54621A/22A/24A/41A/42A Oscilloscopes and Agilent 54621D/22D/41D/42D Mixed-Signal Oscilloscopes

Agilent Technologies 3000 Series Oscilloscopes

PC Based Digital Oscilloscope

Switch Mode Power Supply Measurements

Introduction to oscilloscope. and time dependent circuits

Keysight Technologies How to Make the Best Switch Mode Power Supply Measurements. Application Note

Oscilloscope Operation. Visualizing Signals and Making Measurements

EXPERIMENT 1 PRELIMINARY MATERIAL

SDS Series. Quick Guide

How to Setup and Use an Oscilloscope

Agilent 1000B Series Oscilloscopes. User s Guide

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

Test No. 2. Advanced Scope Measurements. History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 2

CHAPTER 6. Motor Driver

OSCILLOSCOPES. Oscilloscopes CS-5300 SERIES RS-232C OPTION OPTION CS-5370P/5370/5350 FEATURES OUTLINE. Photo: CS-5370P

3.003 Lab 3 Part A. Measurement of Speed of Light

Transcription:

Get started with DSO-X 2014A The oscilloscope has some built-in training signals! Connect two measurement cables with probes to the demo-connectors. Turn the oscilloscope on. Press Default Setup settings from before will be removed.

Scalefactors of the probes The probes will attenuate the signals 10:1, this fact must be known by the oscilloscope in order for it to present correct values. Chose the menu for Channel1, the yellow channel, and then press the Softkey Probe. Choose Probe and turn the Entry-knob to Ratio 10.0:1 and press it. Do the same with Channel2, the green channel.

Measurements of a sinus-voltage Press the button Help to display the soft-menu with the training signals. Choose Softkey Training Signals. Turn and choose Sine with the Entry-knob. Press the button Auto Scale, this is a fix it-button that often will find suitable settings to start your measurements with. Channel1 shows the sinusvoltage, and Channel2 a DC-voltage.

A better picture Set s/div (Horizontal) at 50 ns/div Set Channel1 V/div (Vertical) 500 mv/div Close Channel2 by pressing the button twice. Settings are shown on top of the screen.

Peak-Peak Period Frequency Use the grid to estimate the Peak-Peak value (Pk-Pk), the Period, and the Frequency. You can move the curve with the knobs for Horisontal and Vertikal position. (500 mv/div, 50 ns/div) T = [ns] f ˆ 1 = T V P P = = [khz] [V]

Automatical measurmets Press Meas. As default values for Freq and Pk-Pk are shown. Are the values the same as your estimate? In the softmenu Type you can also chose to calculate/measure AC-RMS-N or DC-RMS-N or Average-N Voltage Peak-Peak Maximum Minimum Amplitude Top Base Oveshoot Preshoot Average-N Average-full DC-RMS-N DC-RMS-full AC-RMS-N AC-RMS-full Time Period Frequency +Width -Width Duty Cycle Rise Time Fall Time Delay Phase

Automatical measurements compared to a DMM U DC DC-component average U AC AC-component rms-average U ACDC Total rms-average Average-N AC-RMS-N DC-RMS-N U = U + U ACDC 2 DC 2 AC U DC-RMS = U 2 Average + U 2 AC RMS

Auto Scale s limitations The fixitall-key Auto Scale, can t handle everything! In order to study complex signals one must use the advanced triggering-functions. You could always run a single sweep and display a steady curve, but it could be tidesome to try out how to display a certain part of the curve. That s the reason for the need of the trigger-functionerns. Press Help to reach the softkeymenu with the training signals. Chose Softkey Training Signals. Twist and choose Sine with the Entry-knob.

Trigg-menu Twist the knob Level and study how the curve moves around the triggeringpoint (in the middle of the screen). Trigger Level What will happen if you sets a trigger level outside the curve? Press the key Trigger to choose from the alternatives under Source or Slope in the trigger-menu. Try different settings. Wich ones will dispay a steady signal? Try to explain what happens. Source 1 2 3 4 External Line Slope (Rising) (Falling) (Alternating) (Either)

Auto Scale Press Auto Scale and find out wich settings the autoscale function does for this signal? Source 1 2 3 4 External Line Slope (Rising) (Falling) (Alternating) (Either) With this pure sine-signal Auto Scale performed good!

Noisy sine-voltage? Press Default Setup and then Help. Choose Training Signal, Sine with Noice. With Auto Scale the noisy sine-signal will show up. You can close Channel2. If you change the atenuation there will no longer be a steady display of the curve. To change the trigger-level will not help. It s hard to synchronise with to noisy signal. Filter the trigsignal. Solution: Mode Coupling, Noise Rej.

Waveform averaging The noisy sine-signal can be clean if one presents an average-curve out of many curves! Press the button Acquire, and then Acq Mode and choose Averaging. # Avgs 8 is the amount of curves N that is averaged together. Noise will be attenuated in proportion of the squareroot of N.

Phasemeasurement Press Default Setup and then Help. Choose Training Signal, Phase Shifted Sine. Choose Phase and set the value fo eg. 45. With Auto Scale traces of two sine-voltages are shown. If channel1 is the reference you can see that Channel2 is later in time (lagging in phase). Press Meas and choose Type, Phase. The measured value will be Phase(1 2): 45

Power measurement Suppose the two sine-traces represents current and voltage to a load. The product between a voltage and a current then represents instantaneous power to the load.

Power measurement Press Default Setup. Press Channel1 menu and choose Coupling AC. Do the same with Channel2. Press Math and choose Operator. Press Help. Choose Training Signal, Phase Shifted Sine. Choose Phase and set to 45. Do not press Auto Scale! Set the traces manualy with Horisontal and Vertical sensitivity we want to be able to continnue to set the phase and don t want to lose this menu.

Instantaneous power Study the power-curve at different phase between voltage and current. u = U p = u i 2 sin( ωt + ϕ) = U = 2 sin( ωt + ϕ) I i I 2 sin( ωt) 2 sin( ωt) = UI ( cos( ϕ) cos(2ωt + ϕ) ) Why has the power-curve the double frequency compared to current and voltage? At which phaseangles will the power be an symetric sine (with the average 0)?