Construction details: Master-C type profiles and joints:

Similar documents
900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

900 SERIES WALL PANELS

Finesse Profiles. Nailstrip

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

Ekoroof LiteTile Dimensions

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

400 SERIES VERTICAL INSTALLATION

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

KS42 MF SERIES - HORIZONTAL INSTALLATION

TABLE OF CONTENTS A-1

REGAL. Installation Manual

The better way to build TM. Installation Manual ROOF SIPs


DW HORIZONTAL INSTALLATION

Everbright E610 polycarbonate light panels Installation guidance

Metl-Span CF-42 Santa Fe Wall Panels 24 Ga. Exterior / 26 ga. Interior Facings Allowable Connection Load 1,7,8,9,10 (psf) Two or More Equal Spans

Ekoroof LiteTile Headwall Flashing Installation Detail

DW VERTICAL INSTALLATION

TABLE OF CONTENTS A. PBR

DUTCH GABLE FREESTANDING CARPORT

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

Austin Standing Seam Awning Assembly and Installation Instructions. Assembly Instructions

Dura-Lock Roof System

eco-shake INSTALLATION INSTRUCTION

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

Table of Contents Light Gauge Metal Roof & Wall Panels

DUTCH GABLE CARPORT RECOMMENDED INSTRUCTION MANUAL

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

SECTION SHEET METAL FLASHING AND TRIM

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

lindab we simplify construction LindabSandwichPanels Installation instructions PIR Panels

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

INSTALLATION GUIDE. Outback. Flat Attached BEFORE YOU START ADDITIONAL MATERIALS TOOLS REQUIRED. VERAnDAHS PATIOS CARPORTS

OUTBACK FLAT ATTACHED VERANDAH PATIO CARPORT - INSTALLATION GUIDE BEFORE YOU START TOOLS REQUIRED ADDITIONAL MATERIALS

OHearneAssociates.com

SpeedZip. Fixing and Handling Guide

UL Construction No. 254

SpeedDeck. Fixing and Handling Guide

KS SERIES - VERTICAL INSTALLATION

Kocked Down with Ends Assembled

SLATE & SHINGLE INSTALLATION

ALL SEASON PATIO COVER

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

3/ /

GABLE ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

FischerTHERM plusdach The Sandwichelement with the special something

Installation Guide. 203 Chesterra Drive, Dahlonega, GA Toll-Free ~ Fax ~

TYPICAL FRAMING AND STITCH FASTENER PATTERNS FOR MAX-RIB PANELS

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

GIRTS ON BACK OF BUILDING

Cambridge English Application Instructions

ROOF CURB INSTALLATION INSTRUCTIONS: VERTICAL STANDING SEAM PANEL

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

Verge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Assembly instructions

Tuff-Rib Install Guide

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

Five Star Panel Installation Instructions

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

Panel Guard Installation For Adhesive Attachment

SHEET METAL FLASHING AND TRIM Christ on the Mountain

Brava Old World Slate Installation Guide

DIRECTIONS FOR APPLICATION

DETAIL CROFT FARM OUTBUILDING RESTORATION TOWNSHIP OF CHERRY HILL, NEW JERSEY

GLOSSARY OF TERMS SECTION 8

ROOFING APPLICATION STANDARD (RAS) No. 130

Ensure there is reasonable access for materials and working space, ensure the shed site is level and consider the disposal of run-off water.

A P P L I C A T I O N I N S T R U C T I O N S

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

INSTRUCTION GUIDE SANCTUARY CANOPY. C & A SUPPLIES LTD, Bidder Street, London E16 4ST tel: WEB:

FischerTHERM plusdach

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

PRODUCT EVALUATION Effective July 1, 2009 RC-204

INSTALLATION GUIDE. Flat Roof Homesheds TM. Onto Concrete BEFORE YOU START TOOLS REQUIRED

Steel Roofing & Siding INSTALLATION GUIDE

~ ~ -

Trapezoidal Roof KS1000 RW Installation Guide

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

METRO PANELS (EXPOSED

Austin Standing Seam Awning with Overhead Braces Assembly and Installation Instructions. Assembly Instructions

Technical Note No. 026

A Shell construction

24 X32 3 CAR GARAGE POLE BARN STYLE FRAME

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS FOR AZTEC SHELTER

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

System for 2+ Level Buildings

ARMORTAB R SUPER TM Shingles Installation Instructions

Pebbletex Adhered Mat Design. Typical Details

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

Transcription:

Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. #12-24 HWH fastener with 1/2 s shall be installed through a 1-9/16 x 20 ga. bearing plate with sealing rubber along the intermediate rib of each panel at each purling. for the distance between supports please consult the table of permissible loads EXPLODED VIEW OF A MASTER-C JOINT: sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. #12-24 HWH fastener with 1/2 s shall be installed through a 1-9/16 x 20 ga. bearing plate with sealing rubber along the intermediate rib of each panel at each purling. for the distance between supports please consult the table of permissible loads 30

Sheet overlaps: sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. a solution to be used when the length of roofing is greater than the maximum transportable: national = 16.00m and export = 39 a 1-9/16 x 20 ga. bearing plate with sealing rubber along the intermediate rib of each panel at each purling. self-tapping screws located on the sealant line >80 mm. (3 5/32 ) overlap Cutting can be in-factory (optional) or on site 200 mm. - 300 mm. (7 7/8-11 13/16 ) remove lower face and 200 mm. - 300 mm. (7 7/8-11 13/16 ) Cover cap overlaps: self-tapping screws one on each side of the overlap overlap must never coincide with sheet overlap pre-prepared for overlap slope min. 100 mm (4 ) manually cut a slot of 100 mm. minimum (4 ) (both lower sides of the ) preparation of overlap 31

Seam plate: 60 mm. (2 3/8 ) 30,30 mm. (1 3/16 ) 10,50 mm. (7/16 ) 20,26 mm. (7/8 ) Bearing plate: 40 mm. (1 9/16 ) 50 mm. (1 15/16 ) 10 mm. (3/8 ) 112 0 32

Cover cap fixing details: s shall be installed staggered 2.5 ft O.C. on either side of the seam cap panel Master-C ASTM E 2140 test Method for water penetration two (2) # 12-24 x 4-1/4 HWH fasteners with 1/2 were installed through a 2-3/8 x 1-9/16 x 16 ga. bearing plate along each panel seam at each purlin prior to installing the 24 ga. steel cap. The cap was installed by aplliying a continuous 3/4 wide bead of Bostik 915 FS TM to the inside of each vertical leg and snap-fitting over the seam. 33

Exterior Guttering: support fixing support a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. 100 (4 ) downpipe Gutter supports, one per 1.50m. (5 ft.) shall be installed on either side of the seam cap. Interior ing on concrete wall: Detail not recommended in geographical areas where the maximum intensity of rain > 20 cm. (10 )/ hour sellador elástico de poliuretano concrete wall weatherboard tapcon type screws a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. 100 4 downpipe concrete wall weatherboard tapcon type screws shall be installed on either side of the seam cap. 34

Central ing: Master-C panel sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. Master-C panel 100 (4 ) 100 (4 ) downpipe bonded sealing washer shall be installed on either side of the seam cap. Side interior ing: Detail not recommended in geographical areas where the máximum intensity of rain > 20cm. (10 ) /hour. a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. 100 downpipe see detail: parapet cap shall be installed on either side of the seam cap. 35

Ridge caps: sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. ridge cap fixing of ridge cap on ridges a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. fixing of ridge cap on ridges ridge cap Valley s: sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. front drip edge 100 4 35 13/8 35 13/8 100 4 valley valley drip edge 36

Top of slope to wall: half ridge cap a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. fixing of half-ridge cap on ridges see detail: parapet cap half ridge cap Copings for slope ends: panel fixing fixing of coping on ridges a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. coping at slope end self-adhesive profile joint coping at slope end #12-24 x 1 HWH fasteners with 1/2 bonded sealing washer 37

Frontal drip edge: a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. drip edge fixing: one screw per ridge 35 13/8 bonded sealing washer frontal drip edge frontal drip edge overhang <400 mm. 15 reinforcing bracket 1 every 1,500 mm. (5 ft.) fixing of reinforcing bracket; two rivets per bracket fixing rivet for reinforcing bracket reinforcing bracket; one every 1,500 mm. (5 ft.) FRONT COVER (other option) slope #12-24 x 1 HWH fasteners with 1/2 Master-C front cover available for 3G Eave drip to false ceiling: sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. drip edge fixing; one screw per ridge 35 13/8 front drip edge reinforcing bracket: 1 every 1,500 mm. (5 ft.) bonded sealing washer fixing of reinforcing bracket: two rivets per bracket front drip edge eave drip to false ceiling flashing false ceiling fixing rivet for reinforcing bracket reinforcing bracket; one every 1,500 mm. (5 ft.) 38

Side drip edge: side drip edge drip edge fixing drip edge fixing sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. bonded sealing washer Side drip edge Side slope: parapet cap rivet fixing rivet sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. parapet cap bonded sealing washer bonded sealing washer parapet cap wall-roof finish 39

Side slope to wall: concrete wall weatherboard tapcon type screw tapcon type screw fixing rivet concrete wall sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. tapcon type screw #12-24 x 1 HWH fasteners with 1/2 bonded sealing washer Side of slope to wall: #12-24 HWH fastener with 1/2 bonded sealing washers shall be installed through a 2-3/8 x 1-9/16 x 16 ga. seam plate along each panel seam at each purling prior to installing the 24 ga. panel cap. weatherboard fixing rivet #12-24 x 1 HWH fasteners with 1/2 bonded sealing washer weatherboard 40