Shielding Effectiveness Comparison Report

Similar documents
Shielding Effectiveness Report

Shielding Effectiveness Report HQDP

Shielding Effectiveness Report HQCD

RF Characterization Report

RF Characterization Report

RF Characterization Report

242, , FAX.

SMB Connectors. Adaptors-50Ω. Plug to Plug. Jack to Jack. Plug to Jack. Bulkhead Jack to Jack

WiFi Interface Identifier

MULTIFLEX The flexible alternative to SEMI-RIGID

EMC Precompliance Systems and Accessories Catalog

CABLE ORDERING INFORMATION How to Build Custom Cable Assemblies

Conduit measured transfer impedance and shielding effectiveness (typically achieved in the RS103 and CS114 tests)

Amphenol RF- BNC Connector Series

HILNA LS Low Noise Amplifier

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

STANDARD COAXIAL CONNECTORS. Eco 7/16 series

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric

Electromagnetic Effects, original release, dated 31 October Contents: 17 page document plus 13 Figures. Enclosure (1)

Double-Ridged Waveguide Horn Antennas

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

Valon Synthesizer RFI Test Report

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Report Of. Shielding Effectiveness Test For. DefenderShield. Test Date(s): September 1 October 2, 2012

Reverberation Chambers Design and Construction Considerations for Aerospace and Military Test Requirements

Correlation Between Measured and Simulated Parameters of a Proposed Transfer Standard

L1 Low Noise Amplifier

Regarding RF Isolation for small Enclosures

Amphenol RF UHF. UHF Connector Series UHF. Description. Features/Benefits. Applications

L1L2 Low Noise Amplifier

TABLE OF CONTENTS SECTION TITLE PAGE. 5. LIST OF EUT, ACCESSORIES AND TEST EQUIPMENT 10 EUT and Accessory List EMI Test Equipment

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

High Speed Characterization Report

SECTION 7 R114 / R115 / R116 / R117 / R112

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

pel.com Microwave & RF, March 23 rd, 2016.

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

High Speed Competitive Comparison Report. Samtec MMCX-J-P-H-ST-TH1 Mated With MMCX-P-P-H-ST-TH1 Competitor A (Mated Set) Competitor B (Mated Set)

Design guidelines Ultra Low Loss cable assemblies.

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

RADIOMETRICS Midwest Corporation

Alternative Radiated Emission Test Methods Progress Achieved in IND60 Project

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

Electromagnetic Compatibility ( EMC )

High Speed Characterization Report

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ADPC-G6 Report No.: LCS E

EXPANDED FREQUENCY ELECTROMAGNETIC INTERFERENCE (EMI) SHIELDING EFFECTIVENESS (SE) TESTING

EMC Near-field Probes + Wideband Amplifier

APPENDIX A TEST PLOTS. (Model: 15Z970)

A Test Lab Techno Corp. Report Number:1410FR27

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

SPECIFICATION. Part No. : GW

High Speed Characterization Report

RF TEST REPORT for Intentional Radiator No SHA-001

High Speed Characterization Report MEC8-1XX-02-X-DV-A

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

S14WI Splitter for Wireless Infrastructure

Test Report. Prepared for: Technologic Systems, Inc. Model: TS Description: Embedded Computer Board. Serial Number: N/A. FCC Part 15B Class A

PXI Modules 3066 PXI Multi-Way Active RF Combiner Data Sheet

PARTIAL RADIATED EMISSIONS AND RADIATED IMMUNITY TEST REPORT

MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

Semi Anechoic Chamber (SAC)

and GHz. ECE Radiometer. Technical Description and User Manual

Better system sensitivity through preamplifiers

A. TESTS: Bonding & Grounding and Radiated Susceptibility, RS103. B. TEST ITEM: One (1) 2U P/N (1P)11229-M , S/N (18S)4P5G

ReversePolarity Series(SMA,BNC,TNC)

Application Note #38B Automotive 600V/m Radar Pulse Test Solution

Screening Attenuation of Long Cables

Contents. CALIBRATION PROCEDURE NI PXIe-5668R 14 GHz and 26.5 GHz Signal Analyzer

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

Test and Measurement for EMC

Normalized Site Attenuation Test Report

Circuit Characterization with the Agilent 8714 VNA

S12 Splitter. Technical Product Data

Microwave Circuit Design and Measurements Lab. INTRODUCTION TO MICROWAVE MEASUREMENTS: DETECTION OF RF POWER AND STANDING WAVES Lab #2

A11 Amplifier. Technical Product Data

A11M Amplifier. Technical Product Data

Figure 1: Worst-Case Emissions *FCC Class B compliance not estimated 4 below 200 MHz due to lack of antenna calibration and chamber reflectivity

Double-Ridged Waveguide Horn

FISCHER CUSTOM COMMUNICATIONS, INC.

NI PXI-2555 Specifications

High Data Rate Characterization Report

USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) MODEL NUMBER: HILNA LS

YRS01 York Reference Source

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

FCC TEST REPORT. Table of Contents. FCC Measurement Report

REVERBERATION CHAMBER FOR EMI TESTING

Company report to support the development of the Ecma MM-EMF technical report (attached)

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

SMA Description Applications Features

8370 Court Avenue, Suite B-1 Ellicott City, Maryland (410) FCC CERTIFICATION

EXPERIMENT EM3 INTRODUCTION TO THE NETWORK ANALYZER

Transcription:

Shielding Effectiveness Comparison Report Shielded (RF316) and Double-Shielded (RS316) Series Cable Assemblies Mates with MCX, MMCX, MMCXV, SMA, SMB5, SSMB, BNC, TNC Description: 50Ω RG316 RF Cable WWW.SAMTEC.COM

Description: Single Table of Contents Overview... 1 Shielding Effectiveness Summary Data... 2 Characterization Details... 4 Product and Test System Descriptions... 4 Product Description... 4 Appendix A Test and Measurement Setup... 5 ETS/Lindgren 2090 Multi-Device Controller and HP Vector Network Analyzer... 6 Shielding Effectiveness Test Setup... 7 Measurement Station Accessories... 7 Shielded Room Noise Floor Verification... 8 Page:ii

Description: Single Overview Samtec has introduced an RG316 cable assembly with enhanced shielding effective- ness (SE) for applications with demanding electromagnetic requirements. Typical ap- is required to obtain the lowest possible noise floor for sensitive receivers. A second application is when sensitive industrial, automotive or military electronics must operate in an elevated field strength environment. A third common application is when stand- ard RG316 cable assembly does not provide the shielding required to meet regulatory compliance requirements, such as FCC Class B or Mil-Std-461. RG316 is a generic name for a flexible 50Ω coaxial cable. RF316 is the Samtec name for our single braid RG316 cable assembly. A new version of RG316 is available with two layers of shielding (RS316) Standard RG316 cable assemblies (P/N RF316-01SP-1-01SP-1-1000, SMA male to SMA male, 1 meter in length) and RS316 cable assemblies with the new double-layer shield (P/N RS316-01SP1-01SP1-1000, SMA male to SMA male, 1 meter in length) ), plications include microwave base stations where minimizing electromagnetic emissions were tested for SE. Samples were mated to Samtecc SMA to SMA bulkhead jacks and terminated at the far end. The testt results show a significant performance improvement in SE. A standard RF316 cable assembly has a SE of roughly 50 db whereass the double shielded RS316 achieves roughly 75 db. Page:1

Description: Single Shielding Effectiveness Summary Data The figure below shows the measured SE for a standard RG316 cable assembly and the new RS316 cable assembly. Note that above 5 GHz the test method does not allow for an accurate measurement of the RS316 due to dynamic range limitations. For example at 10 GHz we know that the RS316 has a shielding effectiveness of at least 65 db. It may actually be 70 db (or higher) but the testt equipment is dynamic range lim- ited. This is discussed more fully in Appendix A. Page:2

Description: Single To more clearly illustrate the performanc ce differencee between the samples, the differ- ence in SE is plotted in the figure below. This graph clearly shows that the RS316 ca- ble assembly has approximate ely 25 db more SE than the standard RG316 cable as- sembly. Shielding Effectiveness Report Page:3

Description: Single Characterization Details This report presents data that characterizes the SE of a cable assembly in a controlled environment. All efforts are made to reveal typical responses inherent to the system un- connectors are attached to bulkhead jacks. The bulkhead jacks are in specially manu- factured bulkheads fitted to fully shieldedd boxes. The mating connector to chassis panel interfacee is critical to shielding performance, and every attempt was made to mimic typi- der test (SUT). In this report, the SUT includes the cable assembly and mating connectors. The mating cal installation practices. Where available, recommended chassis panel cutout dimen- sions were used, and the mating connector typicallyy penetrates this panel cutout. Con- tures such as flanges or EMI gaskets when specified on the mating connector drawing. Product and Test System Descriptions Product Description Product test samples were 1 meter long RG316 Cable Assemblies. The cable is termi- nated by means of a screw-on SMA terminator on the opposite side of the bulkhead connector. The actual part numbers that were tested are shown in Table 1, which also identifies End 1 and End 2 of the assembly. nection between the panel and the mating connector relies on mating connector fea- Length Shield Part Number End 1 End 2 1000mmm 1000mmm Single layer braid Double layer braid RF316-01S P1-01SP1-- SMA straight 1000 plug RS316-01S P1-01SP1-- SMA straight 1000 plug SMA straight plug SMA straight plug Page:4

Description: Single Appendix A Test and Measurem ment Setup The Mode Stirred Chamber Method is documented in IEC 61000-4-21 and was used in this testing. The method relies on exposing a devicee to electromagnetic energy in a large resonant cavity (shieldedd room). An electrically large tuner perturbs the boundary conditions of the cavity resulting in different standing wave patterns and a randomized excitation of the device. Multiple device measureme ents are made at different tuner positions, and the results are averaged. Shielding effectiveness is definedd to be relative to an in-bandb, it means that the received power with the sample in place is 20 db lower than the received power when a reference antenna is in place. A log periodic antenna servess as reference antenna for IEC 61000-4-21. If the shielding effectiveness is 20 the reference from 200 MHz to 2 GHz, and a double-ridge guide horn antenna is the reference from 2 GHz to 20 GHz. This method has a practical high frequency limit de- termined by the instrumentation used, in this case 20 GHz. The low frequency limit is determined by the size of the chamber, which in thiss case is 200 MHz. The system used for this testing is a SMART 200 system by ETS-Lindgren and is shown in Figure 1. Figure 1: Mode Stirred Chamber Method Page:5

Description: Single ETS/Lindgren 2090 Multi-Device Controller and HP Vector r Network Analyzer Page:6

Description: Single Shielding Effectiveness Test Setup Test Instruments QTY Description 1 ETS/Lindgre en Smart200 Reverberation Chamber 1 ETS/Lindgre en 2090 Multi-Device Controller w/ Smart IMM Software 1 HP8720ES 50 MHz 20 GHz Vector Network Analyzerr Measurement Station Accessories QTY Description 1 Agilent 3499B Switch Controller 1 Agilent 8762C Coaxial Switch (DC 26.5 GHz) 1 Mini-Circuits ZHL 42W Coaxial Amplifier (10 MHz 4.2 GHz, +30 db gain) 1 Microwave Power L0218-30 Wideband Amplifier (2 18 GHz, +30 db gain) 2 Ramsey STE300 Shielded Boxes Page:7

Description: Single Shielded Room Noise Floor Verification Prior to performing shielding effectivenes ss testing of a particula sample, it is important to establish the noise floor of the anechoic test chamber by measuring the shielding ef- fectiveness of the receive line while terminated at the bulkhead connector with a preci- sion short. The measurement noise floor data is shown in the figure below labeled Precision short at bulkhead. The differencee between this measurement and that of an in- system. In the graph below the blue trace is the received power with the test sample replaced by a reference antenna Note that the units of the vertical scale are dbm andd representt measured power levels. Any sample that has a shielding effectiveness greater than the dynamic range will there- fore not be adequately characterized. band antenna (per IEC 6100-4-21) is the maximumm dynamic range of the measurement Page:8

Description: Single By subtracting the minimum power level (noise floor) from the maximum power level (in- band antenna) the measurement dynamic range is computed and is shown in the figure below. Page:9