ARMADILLO STAINLESS VAULT CLOSURE REPLACEMENT KIT

Similar documents
JANUARY 2002 ARMADILLO

COYOTE HI-COUNT CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES

COYOTE SPLICE CASE (ADOBE SERIES) FOR UNDERGROUND, AERIAL, AND BURIED SPLICES

SUMITOMO RECOMMENDED PROCEDURE SRP SP-F FutureFLEX SPLICE CASE KIT INSTALLATION PROCEDURES

COYOTE Terminal Closure (Single Chamber) Hermetically Sealed With Hardened Adapters

FIBERLIGN (FDC8) Drop Cable Storage Bracket

FIBERLIGN Suspension: Double & Spread Double

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

SUPERSEDED REVISION. Reasons for reissue of this instruction sheet are provided in Section 7, REVISION SUMMARY.

Frameless Inline Door With Return QCI5263

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

Sliding Glass Door Assembly and Installation Guide

Installation Instructions Stainless Steel Wall Panels

Pow-R-Feed Systems Service Manual

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

3 Emergency Breakaway Coupling

3" [76.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

Frameless Inline Door QCI5248

SPACER APPLICATION: KEY POİNTS FOR HİGH QUALİTY İG UNİTS

1. TOOLS + MATERIALS REQUIRED

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

Frameless Fixed Panel Slider

Body Repair. Collision Repair. Specification. Fastener Specifications Fastener Specifications. Blind Rivet. Flow Drill Screw (FDS) Torque FDS

Frameless Inline Door QCI5254

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

INSTALLATION INSTRUCTIONS. UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE

Palladian/ Keystone Models 202/204 Maintenance Kit

Rigid and Flex Tubular Skylights Installation Instructions

ATLANTIS RAIL Contact Information

Assembly Instructions 10 X 10 Aluminum Frame Building

Char-Lynn Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor November, 1996

Introduction. Depending on your kennel project, you may have some or all of the following hardware: Part # Description Part # Description 1468

Installation Materials Required: Tools Required: 6" self-adhesive flashing. Shims. 3-foot level 6-foot level Tape measure 1/8" drill bit

NEW Plastic Sweep Installation Instructions 40/30 Loop Antennas

Frameless Heavy Glass Door with Header

UNIT No FRAMELESS PIVOT SHOWER DOOR

Chapter 6 Frame And Lens Repairs

INSTALLATION INSTRUCTIONS KK-K9-C12-K CHEVY IMPALA

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

SCULL HANDLES AND GRIPS INSTRUCTION BOOKLET

Frameless Inline Door QCI5250

Frameless Heavy Glass Door with Wall Mount Hinges

INSTALLATION INSTRUCTIONS for DALTON LED SERIES

Frameless Bypass Slider

1 of 2 3/3/2017 4:49 PM

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Included in Hardware Kit. Jeep Cut-Out Fender Flare Set of 4 Set Part # Rev STEP 1 PRIOR TO INSTALLATION

Slide the stock rubber tank mount caps onto the ends of the CS-1 tank mount:

WEAR SAFETY GLASSES WHEN INSTALLING THIS KIT.

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Grain Tank Cross Auger Trough Liner for John Deere 9400 / 9500 Combine

Frameless Door QCI5284

Panel Guard Installation For Adhesive Attachment

Curium 19H Installation Instructions & Parts List

Dubnium 11 Installation Instructions & Parts List

No November, Char-Lynn. Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor

Frameless Bypass Slider

Series Sloped glazed Curtain wall. Installation Instructions

Installation of Fiberglass Windows

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

Two Panel Frameless Bypass Door

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05

MTS-ACB. RENOGY Photovoltaic Module Adjustable Curved Bracket E Philadelphia St, Ontario, CA Version: 1.

PRODUCT: BALDUR + ODEN

Curium 19.4H Installation Instructions & Parts List

Installation Instructions

WK9 WORKTOP KIT Assembly Guide

Chalk Line. #4 Phillips Driver Bit. Cable Cutters

ASCENT & ASCENT XL AFTERMARKET INSTALLATION MANUAL SLIDE-OUT COVER

Frameless Fixed Panel Slider QCI5279

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

GroundControl. Follow instructions contained in this manual. Incorrect installation could result in serious injury or damage to property.

START HERE BEFORE YOU BEGIN FIG 1 STEP 2

Frameless Inline Door QCI5288

southpaw enterprises, inc.

SCF-4 Canister Closures (SCF-4C18-01)

Fiber Splice Box (FSB-D) Installation Instructions

FIXED PANEL SLIDER QCI5241

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

INSTALLATION INSTRUCTIONS 960 RODA GLASS TO GLASS HINGES ANGLED FRAMELESS PANEL / DOOR / PANEL CELESTA DRESDEN TRESOR

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

ASCENT SS & ASCENT SC

INSTALLATION INSTRUCTIONS

N. 15th Street, Middlesboro, KY FLIP TARP DUMP BODY INSTALLATION INSTRUCTIONS

1/4 FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE 1400A-1700A-1800A

Installation Instructions for. Handrail Component System

Dura-Lock Roof System

INSTALLATION OF WELLS SUPER QUICK CHUCK LEFT HAND ON RED WING LATHE

Terminal Replacement Procedures

Snap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel. Contents

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

Cabinet is 90% assembled, all you need to do is to attach the legs, lay the glass top on the cabinet, connect the faucet, drains & ptrap.

Radon 07 Installation Instructions & Parts List

Transcription:

SEPTEMBER 2002 ARMADILLO STAINLESS VAULT CLOSURE REPLACEMENT KIT Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. CONTENTS PAGE 1. NOMENCLATURE...1 2. DESCRIPTION...2 3. ORDERING THE REPLACEMENT KIT...2 4. PREPARATION OF CLOSURE...3 5. DETERMINING CORRECT APPLICATION...3 6. END PLATE INSTALLATION...3 7. SPLICE CASE APPLICATION...8 8. COMPLETED INSTALLATION...8 9. SAFETY CONSIDERATIONS...8 1.00 NOMENCLATURE 1.01 Parts shown below are for a common or typical ARMADILLO Stainless Vault Closure Replacement Kit (Figure 1, & Table A) Splice Case Halves Torque Bars 4. 5. 1. 6. 11. 10. 8. 7. 12. FIGURE 1 - VAULT CLOSURE REPLACEMENT KIT NOTE: Be sure to order the correct Replacement Kit for each individual splice before application. 9. 13. 14. 15. 2. 3. 17. 16. 1. Flame Retardant End Plates 2. LOCKBAR Fastener (front) 3. LOCKBAR Fastener (back) 4. PLP Cue Card 5. Application Procedure 6. Strand Hanger 7. Hanger Studs 8. Cable LOCK-TAPE Roll 9. Air Flange Plug 10. Exterior Bonding Clamp 11. Tip CABLE MeaSURE Tape 12. Black Starter Bolts 13. Feeder CABLE MeaSURE Tape 14. Silicone Sealant 15. Heat Shield Tape 16. End Plate LOCK-TAPE Strips (for LOCK-TAPE Strip only application) 17. Emery Cloth for Scuffing Sheath 1

2.00 DESCRIPTION 2.01 GENERAL - This application procedure covers the description and installation of the Preformed Line Products Company ARMADILLO Stainless Vault Closure for splices in entrance cables in central office vaults, cable entrance facilities (CEF), and subscriber buildings. 2.02 For the correct method, tools and materials to be used in performing work items not specifically described in this section, refer to the applicable practices of the Company. 2.03 The Preformed Line Products Company ARMADILLO Stainless Vault Closure meets all of the requirements specified in the Bell Core Technical Reference PUB 55006. 2.04 It is usable for straight, branch, butt or special application splice configurations. 2.05 It will accommodate LEAD, STALPETH, or ALVYN sheathed cable or a mixture of all three. 2.06 One side of the feeder-cable end plate is covered with a silver-covered heat shield. Be careful not to damage this covering while working with the end plate. 2.07 The Vault Closure End Plate, tip cable end, is designed to hold a maximum of 5 psi air pressure. 2.08 The fire resistant tip cable end plate will accommodate cables ranging in diameter from.492" (1.25 cm) to 1.502" (3.815 cm). 3.00 ORDERING THE REPLACEMENT KIT 3.01 Ordering Form - The tip and feeder cable end plates must be custom drilled to match the vault cable splice since a combination of sizes and pair counts are possible. 3.02 In completing the ordering form the hole size of each tip and feeder cable should be indicated at the desired drill location. Refer to the backside of the from for examples of various end plate designs. (Figure 2) 3.03 Include the needed length of the PLP closure, a chosen closure identification number, and INDICATE IF ANY CABLES HAVE A LEAD SHEATH. (Figure 3) Ace Tele. Co. Joe Smith Main Street CA. #1 1-900 (000) 000-0000 R 1/20/02 1007 8 8 8 9 9 9 8 8 7 7 8 7 FIGURE 3 - ORDERING FORM (EXAMPLE) 3.04 Use the CABLE Mea-SURE TM Tape to determine: (Figure 4) Proper size hole in end plate Number of wraps of LOCK-TAPE TM sealing system to be applied to the sheath; one or two half-lapped layers to be wrapped around the cable. Use A blade and one half-lap of LOCK-TAPE seal FIGURE 4 - CABLE MEA-SURE TM TAPE The shaded area = two half-laps Use C blade and one half-lap of LOCK-TAPE seal Use M blade and two half-laps of LOCK-TAPE seal The clear area = one half lap Use O blade and two half-laps of LOCK-TAPE seal 3.05 If the index line falls on the line between areas, proceed as if the index line had fallen immediately to the right of the area division line. NOTE: Measure the cable at the area where the end plate will be placed, as cable will vary in diameter along its length. 3.06 Measuring Tip Cable - Use the Tip CABLE Mea-SURE Tape to determine the proper size hole in the end plate. (Figure 5) 3.07 If the index line falls on the division line between areas, choose the hole number of either area. FIGURE 5 - TIP CABLE MEA-SURE TM TAPE 3.08 Allow two weeks from receipt of order for shipment of customized ARMADILLO Stainless Replacement Vault Closure. 3.09 Proceed with installation only after receipt of closure. FIGURE 2 - VAULT CLOSURE ORDERING FORM 2 2002 Preformed Line Products Company. All rights reserved.

4.00 PREPARATION OF SPLICE CLOSURE 4.01 Remove present closure from splice bundle and clean the tip and feeder cables in the area where the end plate will be installed. 4.02 Check the cable seal area. Cables should be in good condition and not damaged. The end plate should only be applied on undamaged sheath. 4.03 If more working room is necessary, loosen bonding hardware. 5.00 DETERMINING CORRECT APPLICATION 5.01 Begin the end plate installation by referring to the appropriate application section. End plate application Section Feeder Cable Only 6.01 Tip Cable Only 6.21 Combination of Feeder and Tip Cables 6.33 6.00 END PLATE INSTALLATION 6.01 Feeder Cable Only - Disassemble the end plate by removing the two bolts. Warning: Scuff lightly, do not remove too much material. 6.02 With the emery cloth provided, remove any sharp edges from plastic and foam in the area of the cable opening(s). (Figure 6) NOTE: This simple operation will help prevent catching the sheath and pinching it when later drawing the end plate sections together. Use only the emery cloth provided for this procedure. FIGURE 7 - MARKING SHEATH AREA TO BE CLOSED 6.04 Remove all grease, cable lubricant, mud, etc. from the sheath. Using the emery cloth provided, thoroughly scuff AROUND THE CABLE, NEVER LENGTHWISE along it; scuff sheath for 6 inches (152 mm). 6.05 Coat the scuffed area of the sheath with "C" cement and allow it to dry to a tacky base. Use the removed backing from a LOCK-TAPE strip to wipe off any excess cement to help it dry fast. 6.06 Half-lap 1-1/2" (38 mm) LOCK-TAPE sealant around cable (back side up) in area coated with "C" cement. Stretch tape to reduce its width to 1-1/8" (29 mm) while applying. Use one or two halflapped layers as determined by the previously made measurement. (Figure 8) NOTE: Be sure to remove backing from white side while applying tape. The white side is the sticky side and should be applied toward the cable. Figure 9 shows the completed application of one half-lap of LOCK-TAPE strip. 1-1/2" (38 mm) 1-1/8" (29 mm) FIGURE 6 - DRESSING CABLE OPENING(S) 6.03 Use an end plate half to mark the sheath area at the cable opening to be cleaned and scuffed. (Figure 7) FIGURE 8 - APPLYING LOCK-TAPE STRIP FIGURE 9 - LOCK-TAPE STRIP APPLIED TO SHEATH (FOR LEAD SHEATH CABLE, APPLY ONE EXTRA HALF-LAP.) 3

6.07 FOR LEAD CABLES ONLY. Follow the above procedure for sheath preparation but apply only ONE EXTRA half-lapped layer of LOCK-TAPE sealing system. 6.08 Be sure to keep the LOCK-TAPE sealant wrap dry and free from grease and dirt. 6.09 Apply a thin coat of "C" cement to the inside surfaces of the end plate. (Figure 10) Use backing removed from LOCK-TAPE strips to dry "C" cement applied to end pate. (Figure 11) FIGURE 12 - LOCK-TAPE STRIP APPLIED TO END PLATE HALF 6.11 Square cut the tape away from the bolt hole areas just beyond the metal inset. (Figure 13) FIGURE 10 - APPLICATION OF "C" CEMENT TO END PLATE SURFACE FIGURE 13 - TRIMMING LOCK-TAPE STRIP FROM AROUND BOLT HOLE 6.12 Before applying the end plate halves to the cable, apply "C" cement 1/2" (38 mm) wide adjustment to the hole and 1/2" (38 mm) wide into the hole for the total width of the end plate. (Figure 14) FIGURE 11 - DRYING "C" CEMENT 6.10 When "C" cement becomes tacky, remove protective backing from LOCK-TAPE strips and without stretching it apply it, white side down, to each end plate half. Follow the curve of the hole cut for the cable. Trim end of strips allowing 1/2" (38 mm) of overhang. (Figure 12) FIGURE 14 - APPLYING "C" CEMENT TO END PLATE HALF 6.13 The completed preparation of the feeder cable end plate halves. (Figure 15) 4

(Figure 19 Illustrates the appearance of the LOCK- TAPE sealant application after trimming.) FIGURE 15 - COMPLETED PREPARATION OF END PLATE HALVES 6.14 Before applying the end plate, use the 800-422 Cable Shaper to produce a slightly oval shape to the cable to prevent pinching the sheath. (Figure 16) DO NOT OVERSHAPE LEAD CABLES! Warning: Do not use air-wrenches for the following operation. FIGURE 18 - TRIMMING EXCESS LOCK-TAPE STRIP FIGURE 16 - PLACING END PLATE ON CABLE 6.15 Position the end plate on the cable at the proper point so as to align the torque bar slot near the bottom of the splice. Bring the end plate halves together evenly, tightening each bolt in rotation 2 or 3 turns at a time. 6.16 Using a ratchet wrench draw the end plate halves completely together until the excess LOCK-TAPE strips separate and lay back. (Figure 17) FIGURE 19 - LOCK-TAPE SEALANT APPLICATION AFTER TRIMMING 6.18 Cover outside seam of end plate with 1-1/2" (38 mm) wide heat-shield tape. Apply tape to one side of seam first, then allowing room for LOCK- TAPE strips to expand, apply to other side of seam. Use sufficient tape to extend 1/6" to 1/4" (.62 cm) onto circumference of the end plate and 1" (25 mm) onto the cable. (Figure 20) FIGURE 17 - LOCK-TAPE STRIPS SEPARATED AND FOLDED BACK 6.17 When end plates are completely together, trim excess LOCK-TAPE strips with snips to within approximately 1/4" (.62 cm) of the end plate. Do not pull the tape when trimming. (Figure 18) FIGURE 20 - APPLYING HEAT SHIELD MATERIAL TO SEAM 5

6.19 Use heat-shield tape to cover LOCK-TAPE strips over cable with 2 half-lapped layers; start at the end plate and work out to 3 inches (76 mm) or beyond end of LOCK-TAPE sealant application and work back. (Figure 21) 6.25 FOR LEAD SHEATH CABLE ONLY. Thoroughly scuff around the cable using the emery cloth provided and coat the area with "C" cement. Apply one half-lapped layer of 1-1/2" (38 mm) LOCK-TAPE sealant adhesive to the area of cable where the end plate will be placed. 6.26 Before applying the end plate, oval the tip cables to prevent pinching the sheath. (Figure 23) FIGURE 21 - HEAT SHIELD MATERIAL ON CABLE 6.20 If there is any damage to the heat-shield tape on the end plate, cover such places with pieces of heat-shield tape/material. 6.21 Tip Cable Only - Feeder cable end plate must first be applied. Refer to section 6.01. 6.22 After Feeder cable end plate is in place apply the bottom torque bar. The offset in the torque bar should face the splice bundle. Use the free end of the torque bar to mark the area on the tip cables where the end plate will be placed. (Figure 22) FIGURE 23 - CORRECT SHAPE OF TIP CABLES 6.27 Attach torque bar to bottom retainer core and using the core as a fixture, begin assembling unit starting with the bottom section. PLP TIP Before assembling, support the tip cables in the alignment they'll lay into the end plate grooves. 6.28 Use the tube of sealant and a caulking gun to lay 1/4" (.62 cm) wide beads of silicone lengthwise across seam and 1/4" (.62 cm) from each outside edge. (Figure 24) Silicone should follow down into the contour of each groove. Lay cables in the grooves on top of the sealant. (Figure 25) FIGURE 22 - CORRECT POSITION OF TORQUE BAR FIGURE 24 - APPLICATION OF SILICONE SEALANT 6.23 Remeasure tip cables and confirm proper end plate selection. 6.24 Disassemble the end plate. NOTE: Each section is lettered on the outside face. End plate must be reassembled in the same order to assure the proper alignment of the holes. All letters will be on the same surface. FIGURE 25 - APPLICATION OF TIP CABLES 6

6.29 In the same manner, lay silicone beads to bottom of the matching section and place over top of cables and squeeze hand tight. The silicone will remain workable for approximately 45 minutes, depending on the temperature. 6.30 Build up the remaining sections of the unit by using the same procedure. 6.31 Upon completion, apply top retainer core and tighten bolts on the end plate until the aluminum cores bottom against each other. DO NOT EXCEED 140 IN LBS OF TORQUE (.0158 knm). (Use extra length starter bolts if necessary. Replace with standard length bolts to final tightening.) 6.32 The silicone will be extruded out from all of the seams. DO NOT REMOVE EXCESS SILICONE AT THIS TIME. (Figure 26) NOTE: Be sure to remove backing from white side while applying tape. The white side is the sticky side and should be applied toward the cable. 8.39 FOR LEAD CABLES ONLY - Follow the above procedure for sheath preparation but apply only ONE EXTRA half-lapped layer of LOCK- TAPE adhesive strip. 1-1/2" (38 mm) 1-1/8" (29 mm) FIGURE 26 - COMPLETED APPLICATION OF TIP CABLES 6.33 Combination Feeder and Tip Cables - Remesure feeder and tip cables to confirm proper end plate selection. 6.34 Dissemble the end plate. NOTE: each section is lettered on the outside face. End plate must be reassembled in the same order to assure the proper alignment of the holes. All letters will be on the same surface. Preparation of Feeder Cable(s) only 6.35 Mark the sheath area at the feeder cable opening to be cleaned and scuffed. 6.36 Remove all grease, cable lubricant, mud, etc. from only the feeder cable(s) sheath. Using the emery cloth provided, thoroughly scuff AROUND THE CABLE, NEVER LENGTHWISE along it; scuff sheath for 6 inches. 6.37 Coat the scuffed area of the sheath with "C" cement and allow it to dry to a tacky base. Use the removed backing from a LOCK-TAPE strip to wipe off any excess cement to help it dry fast. 6.38 Half-lap 1-1/2" (38 mm) LOCK-TAPE strip around cable (black side up) in area coated with "C" cement. Stretch tape to reduce its width to 1-1/8" (29 mm) while applying. Use one or two halflapped layers as determined by the previously made measurement. (Figure 27) FIGURE 27 - APPLYING LOCK-TAPE STRIP (SEE FIGURE 9) 6.40 Be sure to keep the LOCK-TAPE Sealant wrap dry and free from grease and dirt. NOTE: Do not wrap LOCK-TAPE strip on tip cables Installation of End Plate 6.41 Before applying the end plate, oval the cables to prevent pinching the sheath. (Figure 28) FIGURE 28 - CORRECT SHAPE OF CABLES 6.42 Using two half-lapped layers of heat shield tape, cover the LOCK-TAPE wrap expected to protrude out from end plate; start at the estimated location of the end plate and work out to 3 inches (76 mm) or beyond end of LOCK-TAPE strip and work back. 6.43 Using the threaded retainer core as a fixture, begin assembling the unit starting with the bottom section. 7

PLP TIP Before assembling, support the cables in the alignment they'll lay into the end plate grooves. 6.48 The silicone will be extruded out from all the seams, DO NOT REMOVE EXCESS SILI- CONE AT THIS TIME. (Figure 30) 6.44 Use the tube of sealant and a caulking gun to lay 1/4" (.62 cm) wide beads of silicone lengthwise across seam and 1/4" (.62 cm) from each outside edge. (Figure 29) Silicone should follow down into the contour of each groove. Lay cables in the grooves on top of the sealant. Around Cable Excess Silicone Excess Silicone at Seam FIGURE 29 - APPLICATION OF SILICONE SEALANT 6.45 In a similar manner, lay silicone beads to bottom of the matching section and over top of cables and squeeze hand tight. Insure that any feeder cables are only applied over LOCK-TAPE wrap. The silicone will remain workable for approximately 45 minutes, depending on temperature. 6.46 Build up the remaining sections of the unit by using the same procedure. 6.47 Upon completion, apply top retainer core and tighten bolts on the end plate until the aluminum cores bottom against each other. DO NOT EXCEED 140 IN LBS OF TORQUE (.0158 kn). Use extra length starter bolts if necessary. Replace with standard length bolts to final tightening. FIGURE 30 - COMPLETED APPLICATION OF CABLES 7.00 SPLICE CASE APPLICATION 7.01 To complete application, attach the top torque bar to the tip cable end plate and the feeder cable end plate, and tighten the bolts. 7.02 Assemble the shells over both end plates by referring to the LOCK-BAR cue card or the tightening instructions label affixed to the front shell. 8.00 COMPLETED INSTALLATION 8.01 After it sets (at least 24 hours), the dried silicone may be torn easily from the seams and not damage the seal. DO NOT ATTEMPT TO REMOVE EXCESS SILICONE FROM AROUND THE CABLES. 8.02 The maximum recommended pressure for the Vault Closure End Plate is 5 psi (34.5 kpa) after a 24 hour cure time. The unit should be flashtested at no more than 3 psi (20.7 kpa) immediately after installation. 9.00 SAFETY CONSIDERATIONS 9.01 This application procedure is not intended to supersede any company construction or safety standards. This procedure is offered only to illustrate safe application for the individual. Failure to follow these procedures may result in personal injury. 9.02 When working in the area of energized lines, extra care should be taken to prevent accidental electrical contact. 9.03 For proper performance and personal safety, be sure to select the proper size PREFORMED Product before application. 9.04 This product is intended for use by trained craftsman only. This product should not be used by anyone who is not familiar with, and not trained in the use of it. P.O. Box 91129, Cleveland, Ohio 44101 440.461.5200 www.preformed.com e-mail: inquiries@preformed.com SP2669-1 8