Reflection mode imaging with nanoscale resolution using a compact extreme ultraviolet laser

Similar documents
Nanoscale Imaging with Extreme Ultraviolet Lasers

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm

Sub 400 nm spatial resolution extreme ultraviolet holography with a table top laser

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Analysis of extreme ultraviolet microscopy images of patterned nanostructures based on a correlation method

Diffractive optical elements based on Fourier optical techniques: a new class of optics for extreme ultraviolet and soft x-ray wavelengths

FULL-FIELD microscopes are the most versatile and widely

Tabletop coherent diffractive microscopy with extreme ultraviolet light from high harmonic generation

Zoneplate lenses for EUV microscopy. EUVL workshop 2009 Iacopo Mochi, Kenneth A. Goldberg, Erik H. Anderson, Sungmin Huh

Talbot lithography: Self-imaging of complex structures

EUV and Soft X-Ray Optics

Present Status of the ASET At-Wavelength Phase-Shifting Point Diffraction Interferometer

The Coherent EUV Scatterometry Microscope for Actinic Mask Inspection and Metrology

Lensless diffractive imaging using tabletop, coherent, high harmonic soft x- ray beams

Critical dimension sensitivity to post-exposure bake temperature variation in EUV photoresists

EUV Plasma Source with IR Power Recycling

Recent Activities of the Actinic Mask Inspection using the EUV microscope at Center for EUVL

Sub-50 nm period patterns with EUV interference lithography

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

On-line spectrometer for FEL radiation at

Applications of Optics

Lithographic measurement of EUV flare in the 0.3-NA Micro Exposure Tool optic at the Advanced Light Source

SUPPLEMENTARY INFORMATION

Zone-plate-array lithography using synchrotron radiation

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Major Fabrication Steps in MOS Process Flow

Modeling of EUV photoresists with a resist point spread function

Nanopatterning in a compact setup using table top extreme ultraviolet lasers

Simple interferometric fringe stabilization by CCD-based feedback control

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

At-wavelength characterization of the EUV Engineering Test Stand Set-2 optic

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

Extreme ultraviolet interference lithography with incoherent light

Very short introduction to light microscopy and digital imaging

Diffractive optical elements and their potential role in high efficiency illuminators

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

A novel High Average Power High Brightness Soft X-ray Source using a Thin Disk Laser System for optimized Laser Produced Plasma Generation

UV EXCIMER LASER BEAM HOMOGENIZATION FOR MICROMACHINING APPLICATIONS

Fabrication of Probes for High Resolution Optical Microscopy

Discovering Electrical & Computer Engineering. Carmen S. Menoni Professor Week 3 armain.

TDI Imaging: An Efficient AOI and AXI Tool

Improving the Collection Efficiency of Raman Scattering

TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES

Pulse Shaping Application Note

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

MICROCHIP MANUFACTURING by S. Wolf

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems

Development of ultra-fine structure t metrology system using coherent EUV source

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

NIST EUVL Metrology Programs

Vertical External Cavity Surface Emitting Laser

High Resolution Microlithography Applications of Deep-UV Excimer Lasers

Characterization of field stitching in electron-beam lithography using moiré metrology

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

Bridging the Gap Between Tools & Applications

Waveguide-based single-pixel up-conversion infrared spectrometer

Instructions for the Experiment

Supporting Information: Experimental. Demonstration of Demagnifying Hyperlens

EUVL Activities in China. Xiangzhao Wang Shanghai Inst. Of Opt. and Fine Mech. Of CAS. (SIOM) Shanghai, China.

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Title: Laser marking with graded contrast micro crack inside transparent material using UV ns pulse

Low Voltage Electron Microscope

Light Microscopy. Upon completion of this lecture, the student should be able to:

Section 2: Lithography. Jaeger Chapter 2. EE143 Ali Javey Slide 5-1

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Spatially Resolved Backscatter Ceilometer

High harmonics generation: Spatial characterisation and applications

Micro-Optic Solar Concentration and Next-Generation Prototypes

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Fiber Lasers for EUV Lithography

Fabrication of micro structures on curve surface by X-ray lithography

Chapter 25. Optical Instruments

Will contain image distance after raytrace Will contain image height after raytrace

Comparison of actinic and non-actinic inspection of programmed defect masks

Testing Aspheric Lenses: New Approaches

Improvement of terahertz imaging with a dynamic subtraction technique

Development of a fast EUV movie camera for Caltech spheromak jet experiments

Imaging in the EUV region. Eberhard Spiller

Project Staff: Timothy A. Savas, Michael E. Walsh, Thomas B. O'Reilly, Dr. Mark L. Schattenburg, and Professor Henry I. Smith

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

Section 2: Lithography. Jaeger Chapter 2 Litho Reader. The lithographic process

Preparations for EUV Interferometry of the 0.3 NA MET Optic. Kenneth A. Goldberg, Patrick P. Naulleau, Paul E. Denham, Senajith B.

Novel laser power sensor improves process control

Attosecond technology - quantum control of high harmonic generation for phase matching

Effects of spherical aberrations on micro welding of glass using ultra short laser pulses

First lithographic results from the extreme ultraviolet Engineering Test Stand

Product Information Version 1.0. ZEISS Xradia 810 Ultra Nanoscale X-ray Imaging at the Speed of Science

Section 2: Lithography. Jaeger Chapter 2 Litho Reader. EE143 Ali Javey Slide 5-1

Commissioning of Thomson Scattering on the Pegasus Toroidal Experiment

Investigation of the Near-field Distribution at Novel Nanometric Aperture Laser

Guide to SPEX Optical Spectrometer

MICRO AND NANOPROCESSING TECHNOLOGIES

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

High power VCSEL array pumped Q-switched Nd:YAG lasers

Immersed transparent microsphere magnifying sub-diffraction-limited objects

Transcription:

Reflection mode imaging with nanoscale resolution using a compact extreme ultraviolet laser F. Brizuela, G. Vaschenko, C. Brewer, M. Grisham, C. S. Menoni, M. C. Marconi, and J. J. Rocca NSF ERC for Extreme Ultraviolet Science and Technology and Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO 80523 brizuela@engr.colostate.edu W. Chao, J. A. Liddle, E. H. Anderson, and D. T. Attwood NSF ERC for Extreme Ultraviolet Science and Technology and Center for X-ray Optics, Lawrence Berkeley National Laboratory, and University of California Berkeley, CA 94720 A. V. Vinogradov and I. A. Artioukov P.N. Lebedev Physical Institute, Moscow 117942, Russia Y. P. Pershyn and V. V. Kondratenko Metal and Semiconductor Physics Department, National Technical University KhPI, Kharkov, Ukraine Abstract: We report the demonstration of reflection mode imaging of 100 nm-scale features using 46.9 nm light from a compact capillary-discharge laser. Our imaging system employs a Sc/Si multilayer coated Schwarzschild condenser and a freestanding zone plate objective. The reported results advance the development of practical and readily available surface and nanostructure imaging tools based on the use of compact sources of extreme ultraviolet light. 2005 Optical Society of America OCIS codes: (180.7460) X-ray microscopy; (110.7440) X-ray imaging; (140.7240) UV, XUV, and X-ray lasers References and links 1. Y. Garini, B. J. Vermolen, and I. T. Young, From micro to nano: recent advances in high-resolution microscopy, Current Opinion in Biotechnology 16, 3-12 (2005). 2. W. Chao, E. Anderson, G. P. Denbeaux, B. Harteneck, J. A. Liddle, D. L. Olynick, A. L. Pearson, F. Salmassi, C. Y. Song, and D. T. Attwood, 20-nm-resolution soft x-ray microscopy demonstrated by use of multilayer test structures, Opt. Lett. 28, 2019-2021 (2003). 3. M. Weiland, Ch. Spielmann, U. Kleineberg, Th. Westerwalbesloh, U. Heinzmann, and T. Wilhein, Towards time-resolved soft X-ray microscopy using pulsed fs-high-harmonic radiation, Ultramicoscopy 102, 93-100 (2005). 4. A. R. Libertun, X. Zhang, A. Paul, D. Raymondson, E. Gershgoren, E. Gagnon, S. Backus, M. M. Murnane, H. C. Kapteyn, R. A. Bartels, Y. Liu, and D. T. Attwood, High-resolution EUV imaging using high harmonic generation, Conference on Lasers and Electro-Optics Technical Digest, Article JMD4 (2004). 5. J. A.Trail and R. L. Byer, Compact scanning soft-x-ray microscope using a laser-produced plasma source and normal-incidence multilayer mirrors, Opt. Lett. 14, 539-541 (1989). 6. I. A. Artioukov, A. V. Vinogradov, V. E. Asadchikov, Y. S. Kasyanov, R. V. Serov, A. I. Fedorenko, V. V. Kondratenko, and S. Y. Yulin, Schwartzschild soft-x-ray microscope for imaging of nonradiating objects, Opt. Lett. 20, 2451-2453 (1995). 7. G. Vaschenko, F. Brizuela, C. Brewer, M. Grisham, H. Mancini, C. S. Menoni, M. Marconi, and J. J. Rocca, Nano-imaging with a compact extreme ultraviolet laser, Opt. Lett. in press (2005). (C) 2005 OSA 30 May 2005 / Vol. 13, No. 11 / OPTICS EXPRESS 3983

8. D. S. DiCicco, D. Kim, R. Rosser, and S. Suckewer, First stage in the development of a soft-x-ray reflection imaging microscope in the Schwarzschild configuration using a soft-x-ray laser at 18.2 nm, Opt. Lett. 17, 157-159 (1992). 9. T. Haga, H. Kinoshita, K. Hamamoto, S. Takada, N. Kazui, S. Kakunai, H. Tsubakino, and T. Watanabe, Evaluation of finished extreme ultraviolet lithography (EUVL) masks using a EUV microscope, Jpn. J. Appl. Phys. 42, 3771-3775 (2003). 10. P. P. Naulleau, "Advanced EUV Lithography Capabilities at Lawrence Berkeley National Laboratory's Advanced Light Source," Proceedings, SEMI Technology Symposium 2004; P. P. Naulleau, K. A. Goldberg, E. H. Anderson, P. Denham, B. Hoef, K. Jackson, A. Morlens, and S. Rekawa, EUV microexposures at the ALS using the 0.3-NA MET projection optics, Microlithography 2005, paper [5751-04]. i.b. Procc. SPIE 5374, 881-91 (2004). 11. Yu. A. Uspenskii, V. E. Lavashov, A. V. Vinogradov, A. I. Fedorenko, V. V. Kondratenko, Yu. P. Pershin, E. N. Zubarev, and V. Yu. Fedotov, High-reflectivity multilayer mirrors for a vacuum-ultraviolet interval of 35-50 nm, Opt. Lett. 23, 771-773 (1998). 12. B. R. Benware, C. D. Macchietto, C. H. Moreno, and J. J. Rocca, Demonstration of a high average power tabletop soft x-ray laser, Phys. Rev. Lett. 81, 5804-5807 (1998). 13. Y. Liu, M. Seminario, F. G. Tomasel, C. Chang, J. J. Rocca, and D. T. Attwood, Achievement of essentially full spatial coherence in a high-average-power soft-x-ray laser, Phys. Rev. A 63, 033802 (2001). 14. Y. Wang, M.A. Larotonda, B.M. Luther, D. Alessi, M. Berrill, V.N. Shlyaptsev, and J.J. Rocca, Demonstration of saturated high repetition rate tabletop soft x-ray lasers at wavelength down to 13.9 nm, to be published, (2005). 1. Introduction As nanotechnology rapidly advances, compact and practical tools capable of imaging at nanometer scales are of growing interest. Several high-resolution imaging techniques currently exist. Compared to electron and scanning tip microcopies, optical microscopy is advantageous in that the sample requires little preparation, images are rapidly rendered and the sample s environment can be varied (e.g. exposed to an electromagnetic field). In particular, reflection mode optical microscopy provides readily accessible topographic information useful in the characterization of, for example, material surfaces, microelectronic integrated circuits, and lithographic masks. However, the resolution of conventional optical microscopes is limited by the wavelength of the illuminating source. To overcome this limitation several methods based on nonlinear optical effects, interference, and surface techniques, that improve the resolution of optical microscopy beyond the diffraction limit have been developed [1]. Higher resolution can also be achieved by using extreme ultraviolet (EUV) and soft x-ray light. Because in this spectral range the reflectivity of most materials is low, previous research at these wavelengths has typically focused on transmission mode imaging. In transmission mode the best resolution reported thus far, 20 nm, was obtained using 2.07 nm wavelength synchrotron radiation [2]. More compact sources, such as high order harmonic EUV sources [3,4] and laser plasma-based soft x-ray sources [5,6] have demonstrated the ability to resolve feature sizes below 1 μm. The best resolution obtained to our knowledge with a table-top EUV transmission microscope, ~ 120-150 nm, was recently demonstrated using a compact EUV laser as the illumination source [7]. In reflection mode, however, only a few experiments have been reported. A proof-of-principle experiment using a soft-x-ray recombination laser was carried out to demonstrate that differential reflectivity from material surfaces produces sufficient contrast in the EUV region [8]. Additionally, 13 nm synchrotron radiation was successfully used to image lithography masks in this mode [9] and to print features with resolution of 20 nm using annular illumination [10]. In this work we demonstrate the imaging of nanometer-scale features with a reflection mode table-top EUV microscope. The instrument utilizes a compact high average power, high repetition rate, 46.9 nm capillary discharge laser as an illumination source in combination with a Schwarzschild condenser and zone plate objective. The high pulse energy (~ 0.1-0.3 mj at 4 Hz) of the laser source used in this work allows us to observe features on a 100 nm (C) 2005 OSA 30 May 2005 / Vol. 13, No. 11 / OPTICS EXPRESS 3984

scale with a large field of view and exposures of only several seconds. The feasibility of obtaining reflection mode images with single shot laser illumination is also demonstrated. 2. Experimental setup The optical system of the EUV microscope is schematically shown in Fig. 1. This reflection mode imaging system consists of a compact capillary-discharge EUV laser, followed by a Schwarzschild condenser that focuses the light onto a sample positioned at 45 degrees relative to the illuminating beam. A freestanding zone plate objective forms a magnified image of the sample onto a back-thinned CCD detector positioned at 90 degrees with respect to the source. CCD Camera 46.9 nm Laser Schwarzschild Condenser Imaging Zone Plate Test Pattern Fig. 1. Schematic representation of the compact extreme ultraviolet microscope. The Sc/Si multilayer Schwarzschild condenser contains a primary convex mirror of 10.8 mm in diameter and a 50 mm secondary concave mirror. Together these two mirrors produce a hollow cone of 46.9 nm light that is focused onto the sample that is at ~ 5 cm from the output of the condenser. The Schwarzschild condenser has a numerical aperture (NA) of 0.18 and a throughput of only ~ 1%. This low throughput could be improved by at least one order of magnitude using Sc/Si multilayer coatings with the best reflectivity available at this wavelength, ~ 40% [11]. A freestanding zone plate was used as the imaging lens. The freestanding design maximizes throughput, as the use of any substrate material would significantly attenuate the 46.9 nm light. The zone plate was manufactured using electron-beam lithography onto a thin nickel foil attached to a silicon frame. It has a diameter of 0.5 mm, an outer zone width of 200 nm, and a NA of 0.12. The focal distance of the lens is 2.13 mm. To achieve high magnification of the imaging system (~ 480 ) the working distance was chosen to be very close to the focal distance of the objective, ~ 2.14 mm. The illumination source used is a table-top capillary discharge laser that emits radiation at a wavelength of 46.9 nm with a ~ 1.2 ns pulse duration and a spectral bandwidth of Δλ/λ<1 10-4 [12]. An Al 2 O 3 capillary 18 cm long was used during most of the experiment, resulting in pulse energy of ~ 0.1 mj [12]. Although a single laser shot produces a discernable image, most images were acquired by accumulating several shots to improve the signal-to-noise ratio and to illuminate a larger area on the sample. Nevertheless, since the laser can be operated at a repetition rate of several Hz, the exposure time was only several seconds. The images were collected on a CCD camera with a back-illuminated 1024 x 1024 array of 24x24 μm 2 pixels. During the experiment the camera was thermoelectrically cooled to a (C) 2005 OSA 30 May 2005 / Vol. 13, No. 11 / OPTICS EXPRESS 3985

temperature of -30 C to improve the signal-to-noise ratio. In this work the distance from the zone plate to the detector typically used is ~ 1 m. Two different samples were imaged. The first consisted of a specially designed nickel test pattern with concentric apertures as small as 100 nm. This sample was produced with the same technique used to fabricate the zone plates. The second sample was a test structure consisting of polysilicon lines patterned on a Si wafer produced for the optimization of the lithography process for chip manufacturing. At a wavelength of 46.9 nm and an incidence angle of 45 o the reflectivity of nickel and silicon are ~ 8 % and ~ 5 % respectively. Coherence effects such as speckle and interference fringes are introduced whenever a laser source is used for imaging. The degree of spatial coherence of the laser used in this work can be modified by selecting the length of the capillary tube. At a capillary length of 36 cm the light is essentially fully coherent [13]. Initially in the experiment we made use of a capillary 27 cm in length, resulting in a high average pulse energy of ~ 0.3 mj and a relatively high degree of spatial coherence. Using this configuration considerable coherence effects were noticeable. We found, however, that slight displacements of the condenser in the direction perpendicular to the beam during a multi-shot exposure significantly reduces these effects. To further reduce interference effects, the capillary length was decreased to 18 cm producing a lower coherence beam with pulse energy of ~ 0.1 mj. Under this condition clear images with only a small amount of speckle and other interference effects were observed as can be seen in the figures below. The shorter capillary is preferable for recording images with a single shot exposure since, in this case, the condenser cannot be moved during acquisition. Single shot images were used to adjust different parameters (i.e. focusing of the imaging zone plate and condenser, and sample positioning) in a quasi-real-time manner at a rate limited by the acquisition time of the CCD. After establishing the best focus for a particular area of the sample, multi-shot exposures were used to improve the image quality. 3. Results and discussion Figure 2 is an image of the Ni test pattern taken in reflection mode at a 45 o angle of incidence with a magnification of 480. The image was obtained accumulating 70 laser shots. To ensure complete illumination of the sample the condenser was slightly defocused and its position was continuously scanned during the acquisition. This scanning also helped to 5μm Fig. 2. EUV microscope image of a Ni test pattern image obtained at 45 o with a magnification of 480. For this image 70 laser shots were used with an exposure time of 70 seconds. The inner apertures are ~100 nm in size with ~ 800 nm separation. reduce coherence effects in the image. As seen in Fig. 2 the 100 nm apertures with ~ 800 nm separation that form the inner ring are discernible. The image was digitally compensated for the horizontal distortion introduced by the angular placement of the sample. Notice that (C) 2005 OSA 30 May 2005 / Vol. 13, No. 11 / OPTICS EXPRESS 3986

because the beam is not at normal incidence with respect to the sample, and the zone plate has a short estimated focal depth of ~3.5 μm, only a central ~ 10 μm wide vertical portion of the image is well defined. An image of the silicon sample is shown in Fig. 3. The image was taken at an angle of incidence of 45 o with a 20 second exposure. In the upper right corner of Fig. 3 (a), 100 nm polysilicon lines separated by 800 nm spaces are discernible, and in the lower right region, 250 nm lines with 250 nm separations are well resolved. Figure 3(b) shows an enlarged view of the 250 nm half-period lines. Even though the 100 nm lines can be seen in Fig. 3(a), their space/line-width ratio appears smaller than the value of eight corresponding to the structure in this sample. This can be attributed to the fact that the finest lines are narrower than the resolution limit of the instrument. a) b) 4 μm 1μm Fig. 3. (a) EUV microscope image of the silicon wafer with 100 nm polysilicon lines separated by 800 nm spaces (top right) and 250 nm half-period lines with equal lines and spaces. This image was obtained with an illumination angle of 45 o with 200 nm outer zone objective using a 20 second exposure (20 laser shots) and a magnification of 480 ; (b) enlarged view of the 250 nm lines/spaces. The spatial resolution of an imaging system is often measured using periodic structures (gratings) with high contrast and sufficiently small period. Here the resolution is defined as the half period of a dense (1:1) pattern that results in a 26.5 % modulation of the image [2] (Rayleigh-like modulation). Analysis of the image in Fig. 3 shows that the modulation obtained for the 250 nm half-period lines is better than 60 %, thus suggesting that the resolution of the imaging system is better than 250 nm. An accurate determination of the microscope s spatial resolution in reflection mode requires imaging of smaller periodic structures with high reflection contrast that were not available at the time of the experiment. However, the spatial resolution of the same instrument in transmission mode was estimated to be in the 120-150 nm range [7]. We expect that the reflection mode resolution is similar. The potential of the imaging system described here for a single shot mode is demonstrated in Fig. 4. In this mode the coherence effects were not mitigated by the scanning of the condenser position due to the very short (1.2 ns) duration of the laser pulse. Therefore with a longer plasma column of 27 cm that corresponds to a regime of relatively high coherence the image is affected by speckle (Fig. 4(a)). With a shorter, 18 cm, plasma column the spatial coherence of the source is significantly lower, thus resulting in a better quality image (Fig. 4(b)). It should be emphasized that the images shown in Fig. 4 were obtained with a very low, ~ 1 %, throughput condenser. We expect that throughput can be increased by a factor of 10 with improved coatings. The single shot mode of operation has proved to be extremely helpful for quick alignment of the imaging system with the laser running at 1 Hz repetition rate. This result demonstrates the feasibility of the development of a laser based high resolution EUV microscope capable of obtaining images of surfaces in quasi-real time regime at a rate mainly limited by the readout of the CCD detector. (C) 2005 OSA 30 May 2005 / Vol. 13, No. 11 / OPTICS EXPRESS 3987

(a) (b) 5µm 5µm Fig. 4. Single shot EUV microscope images of a silicon wafer with polysilicon lines obtained with (a) 27 cm and (b) 18 cm discharge capillary lengths. Shorter capillary length results in reduced coherence and improved image quality. The images were taken at 45 o reflection angle with the 200 nm outer zone width objective zone plate. 4. Conclusions In conclusion, we have achieved high resolution reflection mode imaging using a compact EUV microscope composed of a table-top EUV laser, a Schwarzschild condenser, and a freestanding zone plate objective. Images of both a nickel test pattern and a silicon wafer with features as small as 100 nm were obtained. Even though the reflectivity of these materials at 46.9 nm is low, the high photon flux of the EUV laser allowed us to obtain good quality images with exposures lasting only several seconds. The use of improved Sc/Si coatings on the condenser mirrors will readily allow high quality images to be obtained using a single laser shot with large field of view and better contrast. Moreover, the use of a zone plate with 50-100 nm outer zone widths should allow sub-100 nm resolution [2]. The combination of the above mentioned improvements may allow the development of a compact sub-100 nm resolution EUV microscope capable of inspecting surfaces in a quasi-real-time manner at a rate limited by the acquisition time of the CCD. These results and the recent demonstration of compact high repetition rate extreme ultraviolet laser sources operating in the gain-saturation regime at wavelengths as short as 13.9 nm [14] will likely enable the fabrication of compact diagnostic tools to probe surfaces with sub-100 nm features for nanotechnology, lithographic mask inspection, and material characterization. Acknowledgments This work was supported by the Engineering Research Centers Program of the National Science Foundation under NSF Award Number EEC-0310717. We extend our gratitude to Bryan Tracy and Judy An of AMD, for providing the wafer samples, and to the W.M. Keck Foundation and the US Civilian Research and Development Foundation (CRDF) for their financial support. The work at LBNL also received partial support from DOE/BES and DARPA. (C) 2005 OSA 30 May 2005 / Vol. 13, No. 11 / OPTICS EXPRESS 3988