SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL "A-1"

Similar documents
MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

AUXILIARY FRAMING AND ACCESSORIES

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

MISCELLANEOUS SIGN CONNECTION DETAILS TYPICAL ROUTE MARKER ASSEMBLIES SIGN TO POST MICHIGAN DEPARTMENT OF TRANSPORTATION

New Product Release: October 2014 Boone Racks

FRONT AND REAR HOOD ASSEMBLY (GRAIN CART) REF PART# DESCRIPTION QTY RETAIL

Leveling Feet, Base Plates and Casters

Coro Character PVC Frame Instructions:

BRIDGE RAILING, 4 TUBE B-26-F POST DETAILS MICHIGAN DEPARTMENT OF TRANSPORTATION

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Assembly Instructions 10 X 10 Aluminum Roof Support

Ground Clamps Cable Tray

ALUMINUM PIPE GUIDERAIL 01/01/

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

STEEL PIPE GUIDERAIL 01/01/

WALL TO FABRICATED FLOOR

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Pole Mount Installation Manual

MAST ARMS & POLES. Ornamental Pole Top & Bases

INSTALLATION GUIDE. C20-DH STRAIGHT PARTITION Sprinter Partition ( Perforated Window, No Access, Steel )

UPM 6X Custom. UPM 6X CUSTOM Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

Steel Casework Metal Framing System

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

UPM 6X. UPM 6X Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

Factory Assistance: Phone: Fax: Page 1

FURNITURE LABORATORY METAL FRAMING SYSTEM. For additional information and help in planning contact Mott Manufacturing.

11 6 Round Building Assembly Instructions

Track Rack. * Track Racks are not lockable

Superstrut Stainless Steel Channels and Accessories

TREX POST MOUNT DECKING AND CONCRETE

Mast and Antennas for Field Day & Emergencies

Installation Instructions

Midwest Roadside Safety Facility

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility

APPENDIX FENCE GENERAL NOTES

Index Pipe Hangers and Straps

METER - INSTALLATION Pad Mount Transformer

CSS Central Mount System

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

8" PIVOT. Model 8000 Pivot - Prior to Feb 2002

Installation Instructions

STRUCTURAL HOLDING, CT6 TOOL BOARD, AND CART ASSEMBLY

HILGARD Part Number Spectrum Lane ~ Missoula MT ~

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

ASSEMBLY GUIDE. Mia Narrow Bookcase

INSTALLATION INSTRUCTIONS CONTOURED LIGHT BAR APPLICATION: CHEVY EQUINOX/ GMC TERRAIN PART NUMBERS: ,

3. Use base plate as template (see FIG. 4-1) to mark location for fasteners.

KS SERIES - VERTICAL INSTALLATION

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

Transmission Line Support Systems

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility

INSTRUMENT MOUNTING STANDS PRODUCT CATALOG Continuous Tray Support System for Instrumentation and Controls

SS1062, SS10621 & SS10621E Free Standing PWC & Fishing Boat Hoist SS1062 SS10621 SS10621E

INSTALLATION GUIDE. C20-FTM STRAIGHT PARTITION Transit Partition ( Perforated Window, No Access, Steel )

EZ-Lock Assembly Manual

Single 180 Double 180 Triple. 180 Quad

Kwik-Lock. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MPA-9000 Universal Ceiling Projector Mount Kit

P SERIES. and MASON CORPORATION

PRODUCT CATALOG Meadowview Rd Junction City, OR fax

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

Universal flat-panel mount

DOCK WEDGE - STANDARD

TABLE OF CONTENTS REQUIRED TOOLS

Obsolete as of 12/09/08

FIRE PROTECTION PRODUCTS

BASEBALL FOUL POLES GROUND SLEEVE MOUNTED

BASEBALL FOUL POLES SURFACE MOUNTED

1. Fasten press to bench or work surface using the mounting holes provided (Item 3).

Cat. No. A1200 A1200-S A1200-KO. Finishes & Materials. E142-1/4x100EG 1/4 x 1 A100-5/16EGC A100-3/8EGC. Standard Finish: Electrogalvanized

F-4 FURNITURE. Contents

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg)

1503 Follow Spot Yoke, Source Four LED

Gared Pro-S Portable Backstop

Open Up Your View With CABLE SYSTEMS

SECTION TRAFFIC SIGNAGE

Instruction Sheet For: SCM-2

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

Downtown Rack. Custom logo option available

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

RITE-HITE TPC. FOAM DOCK SEAL WITH HEAD CURTAIN Installation Instructions & Owner s Manual. Date of Installation:

ALUMINUM FOOTBALL GOALS INSTRUCTIONS WARNING WARNING Upright. Upright. Flag. Flag. Offset Pole.

PIPE/CONDUIT SUPPORTS

7141 & NATIONAL POLE VAULT STANDARDS SPECIFICATIONS

Boat Lift Canopy Frame Assembly Instructions

INSTALLATION INSTRUCTIONS

Brackets and Tenons. Product Specifications. PB Series

IF YOU DON T SEE IT HERE

Heavy Duty Ceiling Tilt Mount Installation Manual

FLOE DOCK FURNITURE WARNING ASSEMBLY INSTRUCTIONS

INSTALLATION GUIDE N5-DS48-4

Transcription:

1 1/2" x 60" Galvanized (thread both ends) Top Bolt See Detail "A-1" and Slotted Channel Parallel Conduit Clamp Warning Sign 3 Equal Bolt Spacings (3 places at 12" min. spacing) (1) 3/8"x 7" min. (4"x 6") or (1) 3/8" x 9" min.(6"x 8") (sized to fit wood post) stainless steel hex. head bolts with flat washers and square nuts 1 5/8" x 1 5/8" Galvanized Slotted Channel (12 ga) Bottom Bolt 1 1/2" female PVC adapter or 1 1/2" Only Galvanized Steel Pipe Plug (weap hole drilled) 6" (4"x 6" post) 8" (6"x 8" post) 1 1/2" schedule 80 PVC or rigid metal conduit (*) see note Flasher Controller Note: (*) For projects maintained by the Wayne Co. Department of Public Services (WCDPS), use rigid metal for conduit(s) from grade level to 10' (min.) above grade or as directed by the Engineer. DETAIL "A-1" Parallel Conduit Clamp Slotted Channel SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST File: PW:RD/TR/Signals/Web/Statewide SD/Final Rev. 10/21/14 Michigan Department of Transportation PREPARED BY TRAFFIC AND SAFETY ENGINEER OF DELIVERY ENGINEER OF DEVELOPMENT MICHIGAN DEPARTMENT OF TRANSPORTATION FOR SIGN MOUNTED BEACON DRAWN BY: DJF CHECKED BY: (SPECIAL DETAIL) 1 of 9

Stainless hex. head bolts with lock washers & spring nuts (See Detail "A") See detail "C" 1 5/8" x 3 3/4" x 3 15/16" Four hole galvanized corner angle with hex. head bolts, washers & nuts (See detail "B") 13/16" x 1 5/8" galvanized steel solid strut channel (12 ga.) 1 1/2" Female PVC Adapter 1 1/2" Galv Rigid "Tee" with back plate 1 1/2" Female PVC Adapter Four hole galvanized corner angle with hex. head bolts, washers & nuts (See detail "B") 1 1/2" Schedule 80 PVC or rigid metal Conduit (*) see note 1 1/2" Zinc plated s Stainless Steel hex. head bolts with lock washers & spring nuts (see Detail "A") steel 2 hole Rigid Pipe Clamp with (2) 3/8" galvanized lag screws (3'-0" Spacing) 6" (4"x 6" post) 8" (6"x 8" post) Steel Pipe Plug (weap hole drilled) s 1 1/2" Zinc Plated steel 2 hole rigid pipe clamp (2) 3/8" x 1" Stainless steel hex. head bolt, with lock washer, & 3/8" spring nut (500 series) 1 5/8" x 3 3/4" x 3 15/16" Four Hole galvanized corner angle (2) lock nuts 3 3/4" Flasher Controller (*) see note on sheet 1 of 9 1 5/8" 13/16" x 1 5/8" 1 5/8" (2) 5/16"x 4 1/2" min. (4"x 6") or Galvanized Steel (2) 5/16" x 6 1/2" min.(6"x 8") Solid Strut (sized to fit wood post) channel (12 ga.) stainless steel hex. head bolts (4) flat washers 3 15/16" Steel Coupling DETAIL "B" 1 1/2" 1 5/8" Steel pipe plug 13/16" x galvanized (2) 3/8" x 1 1/2" 1 5/8" rigid Weep hole (drilled) stainless steel Four hole conduit 13/16" Galvanized hex. head bolts galvanized steel 13/16" x 1 5/8" with lock washers corner angle strut Galvanized Steel DETAIL "A" and hex. head nuts channel Solid Strut Channel (12 ga.) 1 1/2" Zinc Plated (12 ga.) Steel 2 hole Rigid Pipe Clamp 1 1/2" (3'-0" Spacing) conduit SINGLE SIGN MOUNTED FLASHING BEACON DETAIL "C" INSTALLED ON TWO WOOD POSTS 2 of 9

13/16" 1 5/8" galvanized steel solid strut channel (12 ga.) 3 3/4" 2 1/2" perforated steel square tube (10 ga.) 1 5/8" 1 5/8" x 3 3/4" x 3 15/16" Four hole galvanized corner angle (2) 3/8" x 1 1/2" stainless steel hex. head bolts with lock washers and hex. head nuts DETAIL "D" (2) lock washers (2) square nuts (2) 5/16" x min. stainless steel hex. head bolts (4) flat washers FRONT VIEW Stainless steel hex. head bolts with lock washers & spring nuts (See detail "A") sheet 2 of 9 (typ) 1 1/2" galvanized rigid conduit Stainless steel hex. head bolts, washers and square nuts (see detail "D") (typ) Perforated steel square tube breakway system 1 1/2" schedule 80 PVC or rigid metal conduit (*) see note Four hole galvanized corner angle with hex. head bolts, flat washers and nuts (see detail "D") (typ) 1 5/8" x 3 3/4"x 3 15/16" Four hole galvanized corner angle (see Detail "D") (typ) 2 1/2" perforated steel square tube (10 ga.) Expansion joint 1" stainless steel banding 1 1/2" galvanized rigid conduit 1 1/2" schedule 80 PVC or rigid metal conduit (*) see note Perforated steel square tube breakway system Grade Level U.G. conduit/cable to flasher controller. SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON TWO STEEL POSTS (PERFORATED STEEL SQUARE TUBE BREAKAWAY SYSTEM) 3 of 9

1 1/2" x 60" Galvanized (thread both ends) rigid conduit. Top Bolt and Slotted Channel Warning Sign 3 Equal Bolt Spacings See Detail "A-1" on Rigid "Tee" with back plate Parallel Conduit Clamp (3 places at 12" min. spacing) (1) 3/8"x 7" min. (4"x 6") or (1) 3/8"x 9" min. (6"x 8") (sized to fit wood post) stainless steel hex. head bolts with flat washers and square nuts 1 1/2" Galv Rigid "Tee" with back plate 1 5/8" x 1 5/8" Galvanized Slotted Bottom Bolt Channel (12 ga) 1 1/2" female PVC adapter or 1 1/2" Galvanized Steel Pipe Plug (weap hole drilled) Only 1 1/2" schedule 80 PVC or rigid metal conduit (*) see note on 6" (4"x 6" post) 8" (6"x 8" post) Flasher Controller Wood posts Expansion joint Grade Level U.G. conduit/cable from flasher controller. SIGN MOUNTED DUAL FLASHING BEACONS INSTALLED ON TWO WOOD POSTS 4 of 9

rigid conduit. 1 1/2" x 60" Galvanized (thread both ends) Top Bolt and Slotted Channel Warning Sign 3 Equal Bolt Spacings See Detail "A-1" on Rigid "Tee" with back plate Parallel Conduit Clamp (3 places at 12" min. spacing) (1) 3/8" x min. stainless steel hex. head bolts with flat washers and square nuts 1 5/8" x 1 5/8" Galvanized Slotted Channel (12 ga) 1 1/2" Galv Rigid "Tee" with back plate Bottom Bolt 1 1/2" female PVC adapter or 1 1/2" Galvanized Steel Pipe Plug (weap hole drilled) Only 2 1/2" perforated steel square tube (10 ga.) 1 1/2" schedule 80 PVC or rigid metal conduit (*) see note Flasher Controller 2 1/2" perforated Expansion joint steel square tube (10 ga.) Expansion joint Grade Level breakeaway system U.G. conduit/cable to flasher controller. SIGN MOUNTED DUAL FLASHING BEACONS INSTALLED ON TWO STEEL POSTS (PERFORATED STEEL SQUARE TUBE BREAKAWAY SYSTEM MICHIGAN DEPARTMENT OF TRANSPORTATION 5 9 of

Aluminum cap (typ) Sign Optical with 12" 1W-1C (LED) yellow lens 1 1/2" bond bushing 1 1/2" hex nut Flat washer Bottom of Sign Optical Serrated washer Jam nut w/set screw 1 1/2" rigid metal conduit DETAIL "A-2" SIGN MOUNTED FLASHING BEACON SIDE VIEW Solar Engine Assambly (Orientation Facing South) Sign Optical with 12" 1W-1C (LED) Yellow lens Tilt Mount Top Plate/Base Bracket Aluminum cap (typ) Sign Optical with 12" 1W-1C (LED) yellow lens Iron Cross (Typ) Iron Cross slip fit Note: Use 6" x 8" wood posts(s) when supporting solar panel(s) U.G. conduit/cable to dual advance warning sign optical location when required. SIGN MOUNTED FLASHING BEACON (ONE SOLAR ENGINE ASSEMBLY) 6 of 9

FRONT VIEW Wood Pole SIDE VIEW Solar Engine Assembly (Orientation Facing South) 3/8"x 5" hex. head lag screw (2 min) 12" Extension height Set Screw Tilt Mount Top Plate/Base Bracket Aluminum Cap (Typ) 1 1/12" x 18" Rigid Pipe Iron Cross (Typ) 1 1/4" Plug to close hole 1 1/2" x 16" Rigid Pipe 3/8"x 5" hex. head lag screw (2 min) Aluminum Cap (Typ) Iron Cross slip fit Pole foot 1 1/4" hole Offset 1 1/4" Schedule 80 PVC or Rigid Metal Conduit (*) see note 1/14" Galvanized Steel 2 Hole Rigid Pipe Clamp (3'-0" Spacing) Solar Power Beacon Advance warning sign location SOLAR ENGINE ASSEMBLY MOUNTED WOOD POLE MICHIGAN DEPARTMENT OF TRANSPORTATION 7 of 9

FRONT VIEW Steel/ Concrete Pole SIDE VIEW Solar Engine Assembly (Orientation Facing South) 12" Extension Height Set Screw Tilt Mount Top Plate/Base Bracket Iron Cross (Typ) Aluminum Cap (Typ) 1 1/4" Plug to close hole 1 1/12" x 18" 1 1/2" x 16" Rigid Pipe Band Rigid Pipe 3/4" x 0.30 Min. Stainless Steel Aluminum Cap (Typ) Iron Cross slip fit Pole Foot 1 1/4" Hole Offset 1 1/4" Schedule 80 PVC or Rigid Metal Conduit (*) see note 3/4" x 0.30 Min. Stainless Steel Band (3' Spacing) Solar Power Beacon Advance warning sign location SOLAR ENGINE ASSEMBLY MOUNTED ON STEEL/CONCRETE POLE 8 9 of

Solar Engine Assembly (Orientation Facing South) 12" Extension Height Sign Optical with 12" 1W-1C (LED) Yellow lens Tilt Mount Top Plate Bracket Cap Post top (slip fitter) * Refer to Standard Plans for Miscellaneous Sign Connection Details 10' - 0" Variable Iron Cross (Typ.) Band Saddle * 3/4" x 0.30" Min. Stainless Steel Band Band Saddle (30" or less, strap at 2 locations) Aluminum Pedestal Frangible Square Aluminum Base SQUARE ALUMINUM BASE Note: Use pedestal collar for pedestal length greater than 14' SOLAR ENGINE MOUNTED ON PEDESTAL 9 of 9