Ludlum Medical Physics

Similar documents
LECTURE 1 The Radiographic Image

Visibility of Detail

QC Testing for Computed Tomography (CT) Scanner

STEREOTACTIC BREAST BIOPSY EQUIPMENT SURVEYS

Acceptance Testing of a Digital Breast Tomosynthesis Unit

X-RAYS - NO UNAUTHORISED ENTRY

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

1-1. GENERAL 1-2. DISCOVERY OF X-RAYS

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

- KiloVoltage. Technique 101: Getting Back to Basics

QC by the MPE in Belgium

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

PD233: Design of Biomedical Devices and Systems

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

Exposure System Selection

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Nuclear Associates

X-ray Tube and Generator Basic principles and construction

Test Equipment for Radiology and CT Quality Control Contents

Nuclear Associates

Nuclear Associates

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

RADIOGRAPHIC EXPOSURE

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

Beam-Restricting Devices

Y11-DR Digital Radiography (DR) Image Quality

Digital Imaging Considerations Computed Radiography

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

Overview of Safety Code 35

Digital radiography (DR) post processing techniques for pediatric radiology

Practical Aspects of Medical Physics Surveys of Mammography Equipment and Facilities

4. Contrast is the. There must The function of contrast is to:. The types of contrast are.

Photomultiplier Tube

Teaching Digital Radiography and Fluoroscopic Radiation Protection

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

diagnostic examination

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

Nuclear Associates , , , , , ,

CHAPTER 6 QC Test For Fluoroscopic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

The effect of compensating filter on image quality in lateral projection of thoraco lumbar radiography

REQUIREMENTS FOR LICENCE HOLDERS WITH RESPECT TO QUALITY CONTROL TESTS FOR DIAGNOSTIC X-RAY IMAGING SYSTEMS

NJDEP Medical Physicist s Radiographic QC Survey Registration Number:

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

Phantoms in Medical Physics (RT) U. Oelfke. Division of Radiotherapy & Imaging

2017 West Coast Educators Conference Orlando. Projection Geometry. 1. Review hierarchy of image qualities (amplified version):

DISC QC/QA Program for Digital Imaging Systems using the DR Radchex Plus Meter

X-ray Tube and Generator Basic principles and construction

Quality Control for Stereotactic Breast Biopsy. Robert J. Pizzutiello, Jr., F.A.C.M.P. Upstate Medical Physics, Inc

Calibration of KAP meters

8/2/2017. Radiologist Responsibilities. Radiologist Responsibilities. Medical Physicist Mammography Equipment Evaluation and Annual Survey

of sufficient quality and quantity

Mammography: Physics of Imaging

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

SUBCHAPTER 14. THERAPEUTIC INSTALLATIONS

CT Basics: Image Quality Module 6

Ask EuroSafe Imaging Tips & Tricks. Paediatric Imaging Working Group. Dose Management in Digital Radiography

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Acquisition, Processing and Display

TOPICS: CT Protocol Optimization over the Range of Patient Age & Size and for Different CT Scanner Types: Recommendations & Misconceptions

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

Nuclear Associates EZ CR-DIN Phantoms

7/20/2014. Outline. Outline. Disclosures. Learning Objectives. SBB: Practical Aspects of ACR Accreditation, QC and ACR On Site Surveys

Unfors EDD-30 Radiation Protection in Fluoroscopy

GE Healthcare. Performa. High-performance breast imaging

Nuclear Associates , , CT Head and Body Dose Phantom

Redefining Ergonomics

Collimation Assessment Using GAFCHROMIC XR-M2

THE ART OF THE IMAGE: IDENTIFICATION AND REMEDIATION OF IMAGE ARTIFACTS IN MAMMOGRAPHY

New spectral benefi ts, proven low dose

RaySafe X2. Effortless measurements of X-ray

PATIENT EFFECTIVE DOSES IN DIAGNOSTIC RADIOLOGY, NA

PHYSICS QUESTIONNAIRE FORM

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

TESTING FLAT-PANEL IMAGING SYSTEMS: What the Medical Physicist Needs to Know. JAMES A. TOMLINSON, M.S., D.A.B.R. Diagnostic Radiological Physicist

DIGITAL RADIOGRAPHY ARTIFACTS

While digital techniques have the potential to reduce patient doses, they also have the potential to significantly increase them.

Features and Weaknesses of Phantoms for CR/DR System Testing

Less effort. More insight.

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

X-RAY. Lecture No.4. Image Characteristics:

Visualization of sources of scattered radiation from x-ray equipment used for interventional radiology

MILADY. Product Data. Page 1 of 8

MaxRay Handheld X-ray Systems Operator Training Exam

XRC X-Ray Calibration System

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

NM Module Section 2 6 th Edition Christian, Ch. 3

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

Image Display and Perception

Assessment of Beam Alignment, Collimation and Half Value Layer of Some Selected X-Ray Machines in Plateau State, Nigeria

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

Transcription:

Ludlum Medical Physics Medical Imaging Radiology QA Test Tools NEW LUDLUM PRODUCT LINE Medical Physics Products

Medical Physics Products What are they? Products used to measure radiation output and to ensure the safety of the medical worker and the patient, as well as the quality of the diagnostic and therapeutic tests administered.** ** Key Difference between MP & HP

Who are the Users of the Medical Physics Products Health Physicist : - Safety of the environment - Safety of Employees/Public - RSO (Radiation Safety Officer) Medical Physicist: -Safety of the Patient (QA) -Quality of the Pictures Produced (QA) -Quality of the Dose Administered QA Tech: -Performs Daily QA Tests (consistency) -Reports results to Med. Physicist Service Tech: -Performs Acceptance Tests on Equip

Radiology Medical Imaging QA A Process that Monitors and Makes Corrections to the Radiation Imaging Equipment, to Ensure the Safety of the Medial Worker, the Patient, and the Quality of the Images Produced. TWO KEY COMPONENTS 1. Patient /Worker Safety Dosimetry ( Safety from Radiation ) 2. Photographic Quality of the Picture Image Quality ( Proper Interpretation-Diagnosis) -What makes a good quality picture possible -Requires a combination of Photographic Characteristics: These are: - Contrast, Density and Resolution (Shades / Dark-Light / Sharpness)

Monitoring and Making Corrections to Image Quality MEASURING IMAGE QUALITY STEP WEDGE - Evaluate Scale of Contrast -Difference in steps (shades of gray) Each Step, Twice the Density (thickness) Of the Previous Step for x-ray to penetrate.. Line Pair Test Pattern -Evaluate Resolution {Ability to see fine details} Lp/mm (Film: 6-10; DR: 2.5-5) Sharp edges vs. fuzzy Visibility of details

How Does the Image Look to the Radiologist Outcome of Imaging QA Image Quality Affects Interpretation of X-ray Examination Low Contrast Film Too many shades of gray Un-sharp edges High Contrast Film -Sharp clear edges

Quality Affects Visibility of Information Low Resolution Lung Fuzzy edges Not Clear High Resolution Lung Sharp edges good detail

QUALITY? High Contrast Hand Good Contrast Hand Too Few gray steps. Good Range of Gray Steps

Contrast too high few shades Good Contrast broad scale of shades

CT of the ABDOMEN -Good Image Quality important to make proper diagnosis The Abdomen view above is pictured in Cross-Sectional view and shows multiple cysts (*) in the region of the (P) Pancreas. Most are located between the left (K) Kidney and the (S) Spleen.

Factors Involved in Image Quality - Some Common Terminology X-ray Tube Wall Bucky Chest Board Collimator / Light Table Bucky Standard Table-Top / Wall X-ray Unit -Proper physical/mechanical alignment - Geometry

Correctly Aligned Angled excessively toward head

Light Field Radiation Field / Match-up Beam Alignment Test Tool Test Tool Image Result of Mis Aligned Collimator

Generation of X-rays X-rays are generated when the (cathode) filament inside the X-ray Tube creates free electrons, while a High Voltage is applied, causing these electrons to be driven into a Tungsten target material (anode). The x-rays emanate from the Anode and are focused and allowed to pass through a beryllium window. The opening is aligned to the Collimator housing, which filters and crops the beam to the needed size for the procedure.

PHANTOM (Attenuation Material) A mass of material that approximates tissue densities and characteristics in its physical properties that mimic human tissue - Interacts with x-rays just like human tissue

Some Tools used to Monitor the quality of the Diagnostic tests Nuc Med Bar Phantom (Resolution ) Light /Radiation Field Tool (Geometry) CR / DR Test Tool Model L-777 Thyroid Phantom (Attenuation)

NEW CT Phantom Versions Classic Separate Section Phantom Nested style Phantom Also Available in individual sections or Head/Body only nested versions

Classic Test Tools Screen Mesh/Resolution; Rotating Spoke Test tool Motion Tracking Contrast, Fine Resolution tool Contrast, gross resolution tool

Classic Test Tools Updated for Digital Use; Measure Contrast, Density, Resolution or just act as Attenuators to adjust (calibrate) imaging equipment Mini- CR/DR Patient Penetrometer Acrylic Modular Phantom Low Contrast Resolution

Finally a couple examples of Safety related Test Tools Tools for Shielding and general Radiation Protection

NEW New Dimension Series Platform of Instruments) MODEL 9DP Pressurized Ion Chamber The MP s Instrument of Choice to Measure Dose Associated with X-ray tube (collimator) Leakage & Scattered Radiation, as well as shielding verification. Also Available in H*10 (Ambient Dose) and Low Pressure Versions (9DP-1)

Medical Physics Safety For Both Medical and general HP applications - SAFETY - New DeCon Kit (Environmental) Clear Pb Lead Acrylic Shielding (Worker Safety)

MORE SAFETY RELATED EQUIPMENT Standard Lead and Lead Glass Shielding

Ludlum Measurements is a Manufacturer If you don t see it in the catalog or on the website, please call. We may be able to manufacture it for you Questions?