EMU Electronic AG. Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) Fax +41 (0)

Similar documents
3-Phase Energy meter with serial S-Bus interface

3-Phase Energy meter for high current measurement converter with Serial S-Bus interface

3-Phase Energy meter with Serial S-Bus interface

Data sheet Energy meter with integrated S-Bus interface

3-phase energy meters with S0 pulse output

S0 pulse counter. with S-Bus interface. Main features: Order number. Technical Data. Mounting

3 phase energy meters with integrated Serial Modbus interface

Single phase energy meter with Serial Modbus interface

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management Energy Meter Type EM110

Three-phase energy meter for transformer connection with S0 pulse output

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Energy Management Energy Analyzer Type EM112

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

3-phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Analyzer Type EM111

Energy Management Energy Meter Type EM340

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Single phase meter with direct connection and pulse or Modbus RS485 output

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Energy Management Energy Meter GM3T E GM3T-RS485 E

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Energy Management Energy Meter Type EM110

METERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

MID energy meter B21 Single-phase energy meter, 65 A

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

SINGLE PHASE STS PREPAID METER

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Energy Analyzer Type EM210 MID

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Data sheet AWD3 3-phase, bidirectional energy meter for current converter metering with integrated S0-output Controls Division

KE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

Energy Management Energy Meter GM3D

C series Product brief

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Multimeter 500CVD21 RTU500 series

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Data sheet. Kamstrup 382 DIN. Application

Energy Management Energy Meter Type EM21 72R Retro-Fit

Power analyzers and Energy Meters Power Analyzer Type WM14-96

RS485 AMR Interface E350 User Manual

COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Introduction DIN rail mounted electricity meters

Power-meters three-phase

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Energy Management Energy Analyzer Type EM24 DIN

This certificate must be used in conjunction with a certificate covering the product verification as required in Annex D or Annex F.

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Energy Management Energy Analyzer Type EM24 DIN

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Universal Radius Mounting Option. Fixed Radius Mounting Option

05/09/2012

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Energy Management Modular Power Analyzers Type WM2-96

Energy Management Energy Analyzer Type EM24 DIN

Energy Management Energy Analyzer Type EM24 DIN

Energy Measurement & Management

Power Meter Series PM3200 Functions and characteristics

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy.

Power consumption In operation At rest For wire sizing

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

PEM353. Universal measuring device

Power consumption In operation At rest For wire sizing

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

DATA SHEET Selectable AC transducer TAS-311DG

Technical data. Safety notes

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

Energy Management Energy Analyzer Type EM210

DELTAplus. DIN Rail Mounted electricity meters. Technical Documentation

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Technical data sheet. Technical data. Safety notes

Energy Management Energy Analyzer Type EM280-72D

Multi-channel DC power digital isolation transducer manual CE-AD81-34MN3-0.5

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

Energy Management Energy Analyzer Type EM270-72D

CompoNet Gateway Unit for CC-Link

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Specification GRUNER YSP 227C

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Measuring current transformers of the W, W series

Rotary Measurement Technology Incremental Encoders

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

ISOMETER IRDH575. Approvals

AEL.TF.19 AEL.TF.20 AEL.TF.21 AEL.TF.24 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE, REACTIVE AND CAPACITIVE ELECTRONIC ELECTRICITY METERS

Transcription:

EMU Electronic AG 3-phase Energy Meter with MID B and D EMU Elektronik AG Jöchlerweg 4, 6340 Baar Switzerland Tel. +41 (0)41 811 02 20 Fax +41 (0)41 811 02 21 Info@emuag.ch / www.emuag.ch Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) 41 811 02 20 Fax +41 (0) 41 811 02 21 info@emuag.ch

3-Phase Energy Meter for direct connection 63A EMU Light 3/65 ST Single Tariff EMU Light 3/65 DT Double Tariff Technical data: Direct connection Maximum current Imax: 63A Nominal voltage Un: 3x230/400V Own consumption: <0.7 W / Phase Start-up current: <15mA Nominal frequency fn: 50Hz Operating frequency: 45 55 Hz In conformity with CE In conformity with IEC 1036 Accuracy class: 1 Accuracy class: B according EN 50470-1 (MID) Operating Temperature range: - 25 C to +50 C Maximum range of measurement: 15mA to 63A Weight: ca. 320g Torque: 2 to 3 Nm Terminal: 7 x 8mm Terminal Tariff control: 2.5 x 3mm Terminal S0 Impulse: 2.5 x 3mm Humidity: Without condensation Operation position: Discretionary Installation: DIN BAR 35mm according EN60715 Tariff control: 230VAC Tariff 2 = Voltage applied Option: MID Approval The Energy Meter Series «EMU Light» is approved by MID Module B + D. The EMU Light is calibrated and certified ex factory. The EMU Light can be used for invoicing ex factory. Display Rolling kwh LCD display Digit dimension: 4 x 8mm 7 digits, one decimal position 000000.0 kwh A barchart is always displayed, giving an indication of the size of the instantaneous power Wrong connection of wires to EMU Light is indicated on display Data rotation on display every 8 second S0 Impulse output According EN 62053-31 Impulse width: 40ms Impulse number: 1 000 lmp/kwh Supply voltage minimal: 18VDC Supply voltage maximum: 30VDC Current: 5-15mA Other impulse number / width on request Subject to modifications and amendments. 1 1

3-Phase Energy Meter for CT connection /5A EMU Light 3/5 ST Single Tariff EMU Light 3/5 DT Double Tariff Technical data Current Transformer Connection /5A Maximum current Imax: 6A Nominal voltage Un: 3x230/400V Own consumption: <0.7 W / Phase Start-up current: <5mA Nominal frequency fn: 50Hz Operating frequency: 45 55 Hz In conformity with CE In conformity with IEC 1036 Accuracy class: 1 Accuracy class: B according EN 50470-1 (MID) Operating Temperature range: - 25 C to +50 C Maximum range of measurement: 5mA to 6A Weight: ca. 320g Torque: 1 Nm Terminal: 4 x 6mm Terminal Tariff control: 2.5 x 3mm Terminal S0 Impulse: 2.5 x 3mm Humidity: Without condensation Operation position: Discretionary Installation: DIN BAR 35mm according EN60715 Tariff control: 230VAC Option: CT Factor The CT Factor can be adjusted by EMU Elektronik in Switzerland.If the CT Factor is unknown, EMU Elektronik will adjust the CT Factor 5/5A. MID Approval The Energy Meter Series «EMU Light» is approved by MID Module B + D. The EMU Light is calibrated and certified ex factory. The EMU Light can be used for invoicing ex factory. Display Rolling kwh LCD display Digit dimension: 4 x 8mm 7 digits, one decimal position 000000.0 kwh A barchart is always displayed, giving an indication of the size of the instantaneous power Wrong connection of wires to EMU Light is indicated on display Data rotation on display every 8 second. S0 Impulse output According EN 62053-31 Impulse width: 40ms Impulse number: 1 000 lmp/kwh Supply voltage minimal: 18VDC Supply voltage maximum: 30VDC Current: 5-15mA Other impulse number / width on request Subject to modifications and amendments. 2 2

M-Bus Optional for series EMU Light According EN1434 Baudrate: Adjustable via M-Bus Wiring by twisted two-wire line YCYM or J-Y(St)Y 2 x 2 x 0,8 mm. Pluggable terminal on EMU Light. The maximum distance between master and slave / repeater, depending on the bus, cable cross-section and the baud rate, between 350m and 10km Any network structure possible. Rad out data Active Energy (kwh) Tariff 1 Active Energy (kwh) Tariff 2 (DT) Active Energy (kwh) Supply Tariff 1 (2Q ST) Active Energy (kwh) Supply Tariff 2 (2Q DT) Instant Active Power (W) Phase 1 Instant Active Power (W) Phase 2 Instant Active Power (W) Phase 3 Instant Active Power (W) total Instant Voltage (V) Phase 1 Instant Voltage (V) Phase 2 Instant Voltage (V) Phase 3 Instant Current (A) Phase 1 Instant Current (A) Phase 2 Instant Current (A) Phase 3 Instant Current (A) total Instant Power Factor (Cos Phi) Phase 1 Instant Power Factor (Cos Phi) Phase 2 Instant Power Factor (Cos Phi) Phase 3 15min Maximum Current (A) Phase 1 15min Maximum Current (A) Phase 2 15min Maximum Current (A) Phase 3 15min Maximum Power (W) Phase 1 15min Maximum Power (W) Phase 2 15min Maximum Power (W) Phase 3 Number of Power Supply Failures CT Factor (EMU Light 3/5) Constant S0 (Imp/kWh) 3

EMU Electronic AG Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) 41 811 02 20 Fax +41 (0) 41 811 02 21 info@emuag.ch