GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Similar documents
Ø 1250 * 688 mm 93 kg ± 105m

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Ø560*336mm 4.25 kg 2100 ± 105m

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Single-Armored Cables, Fibers

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Outdoor, Fig 8 Armored, Multi Tube

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Outdoor, CCTV or CCTV, Fig 8 Armored.

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Fibre Optic Indoor/Outdoor Cable

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

Optical Systems Contents

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Standard Monotube SAFE

features and benefits

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

Exhibit A Construction Project Manual and Drawings

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Outside Plant All Dielectric

SPECIFICATION. Optical Fiber Cable

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Integrating Global Communications...

Type QG-G50-2C- M-BU

Datasheet Outside Plant Cable

Fiber Optic Outside Plant Cables (4-144 Fibers)

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Industrial Automation

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

COPPER + LWL RAW CABLES

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

FTTH Fiber Optical Cable

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Information technology. Generic cabling systems, General requirements

Z EE E E Z E Z Z Z Z Z

u n a B Optical Cables UNIFLEX CABLES LTD.

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

Electric cables. Cranes

Medium Voltage Power Cables

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

FiberHome Fiber Products

kv: medium voltage reeling cable with fibreoptics

Optical Characteristics of a Reduced Bending-Loss Fiber with a Bending Radius of 5 mm

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

NETWORK CONNECTIVITY SYSTEMS

OFS AllWave non-dispersion shifted single-mode optical fiber

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Application of Ultra-Low Bending Loss Fiber PureAccess-R5 to Optical Wiring in FTTx Access Networks

Data, Network and Bus Technology

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Nufern 980 nm Select Cut-Off Single-Mode Fiber

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Connection technology for wireless communication systems

Category 6 A F/FTP Euroclass C ca Cables

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Why Using Fiber for transmission

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

MULTIMEDIA CABLE H6091ZHB

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

Y O U R W A Y ENGINEERING PRODUCTS. adritec.com

Selection table for flat & ribbon cables

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

ABOUT US ABOUT US 1 CRANE CABLES

SUBMERSIBLE PUMP CABLES

Coaxial Cable. coaxial cable

X-ECT MX Electrical Cable Tie, X-EKS MX and X-EMTSC Conduit Clip Fastener

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Copper and Fiber Optic Cables

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

Category 6 UTP EuroClass C ca Cables

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

ZHONGTIAN TECHNOLOGIES CO., LTD

Product Bulletin. Belden DataTwist 4800 Cables

E2-E3 CONSUMER FIXED ACCESS. CHAPTER-4 OVERVIEW OF OFC NETWORK (Date Of Creation: )

Fiber Optic Principles. Oct-09 1

Jumper cable. Feeder cable + connector. Cable clamp. Grounding kit

Install & Go Cat.8 STP Trunk Cable Assembly Description

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Transcription:

GORN Central Loose Tube Cables Outdoor A-DQ(ZN)BY Improved Rodent Protection, 000N Permanent Load 05--0 v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM GORN0 GORN04 GORN06 GORN08 GORN GORN6 GORN4 50/5-OM BI GORN0 GORN04 GORN06 GORN08 GORN GORN6 GORN4 50/5-OM3 BI GORND0 GORND04 GORND06 GORND08 GORND GORND6 GORND4 50/5-OM4 BI GORNE0 GORNE04 GORNE06 GORNE08 GORNE GORNE6 GORNE4 ITU G.655 C&D GORN70 GORN704 GORN706 GORN708 GORN7 GORN76 GORN74 ITU G.65D & G.657A BI GORN80 GORN804 GORN806 GORN808 GORN8 GORN86 GORN84 ITU G.657A BI GORNF0 GORNF04 GORNF06 GORNF08 GORNF GORNF6 GORNF4 ITU G.657B3 BI GORNI0 GORNI04 GORNI06 GORNI08 GORNI GORNI6 GORNI4 Std. plywood reel (non-returnable) Std. delivery length Ø800*475mm 7.65 kg 00 ± 05m Applications For outdoor use in structured (data) wiring systems (campus backbone) For outdoor use in networks for telecom, cable TV and/or broadcast. Suitable for direct burial. Easy to install in ducts, tunnels and trenches. Features & Benefits A simple cable construction and consequently more cost-effective up to 4 fibres then multi-tube cables. With standard or improved rodent protection. Predicted lifetime > 30 years. These cables are all dielectric and therefore immune to lightning and electromagnetic interference (EMC-safe), spark-free and require no earthing.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794). Primary coated optical fibres: Ø 50 ± 5 um.. Central tube, jelly filled (non-dripping and silicon-free) with up to 4 fibres. Individually colour coded optical fibres: : red natural yellow blue green violet brown black orange - turquoise pink and white. 3 4: red natural yellow blue green violet brown grey orange turquoise pink and white with rings. 3. Swellable glass yarns as strength members and for the longitudinal watertightness and the improved rodent protection. 4. Black UV resistant PE outer jacket. Identification: BELDEN OFC cable type number x type of fibre + date-, meter- and marking. Mechanical Data No. of fibres Max. 4 Ø Central tube (mm) 3.3 nom./max. (mm) 7. / 7.4 Energy of flame (kj/m) 056 Weight (kg/km) 44

Optical Characteristics Characteristics Single-Mode Matched-Cladded optical fibres according to ITU. Mode-Field /Cladding Diameter (um) Attenuation B typical/ max. (db/km) Dispersion (ps/(nm-km) PMD A (ps/km) Cable Cut-off 7 G.655 C&D 8.4 ± 0.6 5 ± 0.7 0. / 0. 0. / 0.4 4.5 7.9 < 0.04 60 8 G.65D & G.657A BI OS 9. ± 0.4 5 ± 0.7 30 3 / 4 0.8 / 0.9 0.0 / 0.4 3. 7 0.06 60 F G.657A BI 8.9 ± 0.4 4.8 ± 30 4 / 5 0.9 / 0. 0.0 / 0.4 3.5 8 0. 60 I G.657B3 BI 8.8 ± 0.4 5 ± 0.4 30 4 / 5 0.9 / 0. 0.0 / 3.5 8 0.06 60 Note A- Link design value Note B- Due to cabling the optical attenuation values can increase with max. 0.05 db/km Characteristics Multi-Mode Graded-Index optical fibres according to IEC 60793 Fibre- Type Core/ Cladding Diameter (um) Attenuation C typical/ max. (db/km) Bandwidth (MHzkm) Ethernet Performance (m) GBE 0 GBE Num. Apert. (µm) 6.5/5 OM 50/5 OM BI 6.5 ±.5 5 ± 50 ±.5 5 ±.7 / 3.0 0.7 / 0.8.3 /.5 / 0.6 00 600 0 600 600 33 83 0.75 ± 0.05 0.0 ± 0.05 D 50/5 OM3 BI 50 ±.5 5 ±.3 /.5 / 0.6 000 0.0 ± 0.05 E 50/5 OM4 BI 50 ±.5 5 ±.3 /.5 / 0.6 3500 00 0.0 ± 0.05 Note C- Due to cabling the optical attenuation values can increase with max. 0.4 db/km 3

Macro Bending Performance Fibers Maximum attenuation increase for Bend Insensitive Single Mode fibers in db depending on turns and radius. 7 G.655 C & D 00 30 mm 0.05 0.05 0 5 mm 6 mm 0 mm 7.5 mm ) 5 mm 8 G.65D & G.657A BI OS 0.5.0 0.75.5 F G.657A BI 0. 0. 0..0 I G.657B3 BI 0. 0.08 0.5 0.5 0.45 Maximum attenuation increase for Bend Insensitive Multi Mode fibers in db depending on turns and radius. 6.5/5 OM 00 37.5 mm 5 mm ) 7.5 mm 50/5 OM BI 0. 0. D 50/5 OM3 BI 0. 0. E 50/5 OM4 BI 0. 0. 4

Mechanical, Physical and/or Environmental Characteristics Description: Tested according to: Requirement: According to Family specification: Storage Temperature Range IEC 60794---F -30 to +70 C IEC 60794-3-0 Installation Temperature Range -5 to +50 C Operating Temperature Range -30 to +70 C Bending Tube (Installation and Operation) > 5 mm Cable Water Blocking IEC 60794---F5 Pass Cable Min. Bend Operation (Long Term) IEC 60794---E 0 x Cable Diam. IEC 60794-3-0 Cable Min. Bend Installation (Short Term) IEC 60794---E6 0 x Cable Diam. Cable Max. Tensile Strength Operation (Long Term) IEC 60794---E 000 N IEC 60794-3-0 Cable Max. Tensile Strength Installation (Short Term) Cable Max. Crush Resistance Operation (Long Term) Cable Max. Crush Resistance Installation (Short Term) IEC 60794---E3 0 N 7.5 kn/m 5 kn/m IEC 60794-3-0 Safety Testing standard Toxicity NF X 70-00- Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Universal (halogen-free) cables for outdoor and/or indoor use. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 5