A. Submit manufacturer's technical data and installation for each type of sign required.

Similar documents
SECTION SIGNAGE

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION IDENTIFYING DEVICES

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

SECTION INTERIOR SIGNAGE

Advisory Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges.

SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

Americans with Disabilities Act (ADA) Federal Guidelines

A. Product Data: For each electrical identification product indicated.

SECTION INTERIOR SIGNAGE

A. Submit properly identified manufacturer's literature before starting work.

*********************************************************************************************************

Chapter 14. Signage Guidelines 14.2 GENERAL DESIGN OBJECTIVES 14.1 INTRODUCTION AND PURPOSE 14.3 GENERAL SIGN DESIGN GUIDELINES

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

SECTION BULLET- RESISTANT DOORS

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

Table of Contents. Ninety Edge. BevelED Edge. Reveal Collection ENCLOSURES 7 KIOSKS 8 ARC ENCLOSURES 9 KIOSKS 10. Carve collection.

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

Project: # Solano Community College District

SECTION IDENTIFYING DEVICES

Design and Construction Standards SECTION ATHLETIC LOCKERS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

INTERIOR SIGNAGE MANUAL

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

Guide Specification Section Interior Suspended Sliding Glass Doors

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

SECTION METAL FABRICATIONS

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

SECTION CABLE TRAYS

GUIDELINE SPECIFICATIONS

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

CHABOT-LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT COLLEGE CAMPUS MASTER SIGN PROGRAM, PHASE 2 BID NO

A. Interior and exterior non-illuminated tactile building signs including Braille.

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SECTION ARCHITECTURAL WOOD CASEWORK

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

SECTION HOLLOW METAL DOORS AND FRAMES

Item 550 Chain Link Fence

SECTION SWINGING AUTOMATIC ENTRANCES

Mohawk Sign 2010 ARCHITECTURAL GRAPHICS CATALOG. A Sign of Quality Since 1946

SECTION SHEET METAL FLASHING AND TRIM

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Construction Guidelines 1

APPENDIX FENCE GENERAL NOTES

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

PART MATERIALS. Section Fencing Materials. Description

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

ETCHED PLAQUES by Matthews International

DIVISION 6 WOOD AND PLASTICS

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SHEET METAL FLASHING AND TRIM Christ on the Mountain

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION METAL LOCKERS

SECTION ARCHITECTURAL WOODWORK

CITY OF TOMBALL. Section FIRE HYDRANTS 1.01 SECTION INCLUDES. A. Fire hydrants. B. Adjustment of fire hydrants and gate valves.

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

BUILDING SIGN PROGRAM JULY 2012

Environmental graphics

PRODUCT DATA CATALOG

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

Guide Specification Section Interior Aluminum Doors and Frames

Product Catalog. hardwaresuppliers.com

SECTION CHAIN LINK FENCING

The following instructions will guide you through the installation of your new vinyl railing stair kit.

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

Piping & Equipment Identification

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION MANUFACTURED CASEWORK

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

CHAPTER TWO Fire Lanes & Fire Access

Product Guide Specification

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

Melamine Plastic Laminate. Toilet Partition Installation Manual

FLOOR ANCHOR SYSTEM APPLICATIONS L TRACK APPLICATIONS

Summary of Modifications/Changes in this Update

Uniform Sign Plan (USP) MacGregor Village 86-USP-003

MITCHELL FURNITURE SYSTEMS, INC.

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

SECTION ELECTRICAL IDENTIFICATION

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

APPENDIX 6. SIGNAGE TYPES: Signage as manufactured by KROY Sign Systems, N. Hayden Road, Scottsdale AZ 85260

DIVISION 12 - FURNISHINGS. Section General Discussion. Introduction

Bovard Studios Inc. Section April 6, 2004 Page 1

TO O L K IT. Public Bike Repair

SECTION CHAIN LINK FENCING AND GATES

Beds may be put up or taken down quickly by use of a simple bolted connection at rails and uprights. MATERIALS LIST

PHOTOPOLYMER BRAILLE RASTER BRAILLE MOLDED BRAILLE QUICK SHIP ADA BRAILLE SIGNS. Photopolymer sign panel in a variety of thicknesses.

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

1.1 RELATED DOCUMENTS

ATI Evaluation Service A Division of Architectural Testing Certification Services

Transcription:

SECTION 10425 PART ONE GENERAL 1.1 SECTION INCLUDES A. Interior Building Signage. B. Handicapped parking signs. C. Permanent Project Sign. 1.2 DESCRIPTION A. Signage shall consist of room number and room function to meet the requirements of the Americans with Disabilities Act (ADA), ANSI A117.1 2003 and UFAS - 1988. 1.3 SUBMITTALS A. Submit manufacturer's technical data and installation for each type of sign required. B. Submit shop drawings listing sign size, letterform and letter heights. C. Submit one full size sample sign of type, style and color specified, including method of attachment. If approved, the sample will become part of the job. D. Submit Manufacturers descriptive literature and specifications, including color samples for selection by the Architect. Physical samples only will be accepted. E. Submit manufacturer's installation instructions. Include installation template and hardware. 1.4 PRODUCT HANDLING A. Deliver and store products to site under provisions of Section 01640 ʻProduct Handlingʼ. 1.5 VOC REGULATIONS A. All coatings must be Ozone Transport Commission (OTC) compliant for VOC Regulations. B. All Paints, primers sealers and adhesives shall comply with Green Seal (GS-36) for commercial adhesive and (GS-11) for architectural coatings. 10425-1

PART TWO PRODUCTS 2.1 INTERIOR BUILDING GRAPHIC PROCESS A. Tactile characters shall be raised the required 1/32" above sign face. Glue-on letters or etched backgrounds are not acceptable. B. All letters, numbers and/or symbols shall contrast with their background, either light characters on a dark background or dark characters on a light background. Characters and background shall have a non-glare finish. C. All tactile characters shall be accompanied by Grade 2 Braille. Braille dots shall have a domed or rounded shape. Braille shall be located beneath entire text and shall be separated 1 2" from the corresponding raised characters or symbols. Grade 2 Braille translations to be provided by signage manufacturer. D. Plaque material shall be a 1/8" thick laminate with a melamine resin surface and a phenolic resin core which provides resistance to abrasion, stains, alcohol, solvents, boiling water, and heat. The material shall be NEMA rated and have flammability and smoke values that meet the standards for flammability of interior materials. E. Background color as selected by architect from manufacturer's actual color samples. F. Letterform shall be Gill Sans upper case letters and numbers G. Size of letters and numbers shall be as follows: 1. Room numbers shall be 1 ". 2. Lettering for room ID signs shall be 5/8" or as noted. 3. Symbol size shall be 4". 4. Standard Grade 2 Braille shall be 1 2" below copy. 5. Corners: 1 2" radius 6. Copy position: CC (centered/centered) or as indicated on drawings. 2.2 HANDICAPPED PARKING SIGN 10425-2

A. Signs shall be.063" thick aluminum with radius corners. Blue/White silk-screened baked enamel finish. 12 inch by 18 inch reflective screened heavy gauge steel. All signs shall have a white background. Signs shall have the words Reserved Parking in capital letters above the Symbol of Access (wheelchair symbol). In addition, van accessible parking space signs shall have the words Van Accessible in capital letters below the Symbol of Access (wheelchair symbol). On all signs, the Symbol of Access or wheelchair symbol shall be white on a square blue background. B. Provide one for each handicapped space as indicated on the site plans. C. Mounting: 2 square painted steel posts, capped. 2.3 EXTERIOR BUILDING DESIGN A. Permanent Project sign shall be routed polymer casting, painted, per the concept sketch on the drawings. Signmaker shall confirm sign construction, detail, mounting, etc. PART THREE EXECUTION 3.1 EXAMINATION A. Verify surfaces are ready to receive work. Beginning of installation means installer accepts existing surfaces. 3.2 INTERIOR BUILDING INSTALLATION A. Install signs after surfaces are finished, in locations as indicated on the Drawings. B. Signs shall be mounted using vinyl tape and silastic adhesive. Mechanical mounting shall be used for In Case of Fire Do Not Use Elevator sign. C. All signs shall be mounted 60" from the finished floor to the center of the sign on the latch side of the door. The distance between the doorframe and sign should be 2". D. When the tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. If the door is glass, a blank sign of the same size shall be installed on the other side of the glass to conceal the adhesive. E. When the tactile sign is provided at double doors with two active leaves, the sign shall be to the right of the right hand door. 10425-3

F. Where there is no wall space on the latch side of a single door, or to the right side of double doors, signs shall be on the nearest adjacent wall. G. Signs containing tactile characters shall be located so that a clear floor area 18 x 18, centered on the tactile characters, is provided beyond he arc of any door swing between the closed position and the 45 open position H. Where there other conditions, consult with the Architect as to its alternate location. Installer assumes responsibility for suitable installation of the signs. 3.3 HANDICAPPED PARKING SIGN INSTALLATION A. Signs shall be securely mounted to steel posts with the bottom edge of the sign a minimum of 5ʼ-0 above ground level per ANSI A117.1. The signs shall be installed perpendicular to the driveway plane. 1. Review all locations of Symbol of Access Signs with the Ownerʼs Representative before placement. Posts for Symbol of Access signs shall be finished with two coats of paint. 2. Posts shall be 2 steel square posts, capped, in length required for mounting signs at ANSI minimum height. Set posts a minimum of 3ʼ below grade in concrete as per drawing detail and 2ʼ-0 from face of curb or edge of pavement, where able, to avoid post damage from automobiles. Post shall be break away. 3. Where posts are to be set in new concrete walks or curbs, place sleeve into concrete walk or curb for post to fit firmly into it. Keep sign out of flow of walkways or main routes. Do not install/allow signs to project into adjacent walking space. 4. Where posts are placed in planted or lawn areas, set posts firmly in a concrete footing 8 inches square and extending 2 feet below finish grade. Top of footing shall be even with finish grade. 5. Signs shall be secured to posts with two carriage bolts (3/8 inch hot dipped galvanized steel carriage bolts) at the top; and bottom of the sign, placed in such a manner as not to obscure the Symbol of Access and lettering. Strip mount bolt threads behind fastening nuts to make vandal proof. Top of signs shall be even with top of posts. 6. Sign height shall be high enough that the sign is not obstructed by the parked vehicles. 10425-4

7. After installation, clean soiled signs surface according to manufacturer's instructions. Protect from damage until acceptance. 3.4 PERMANENT PROJECT, DIRECTIONAL SIGNS INSTALLATION A. Signs shall be securely mounted with non-corrosive fasteners as shown on plan, or if not otherwise shown, on 4 x 4 treated posts with vinyl column covers. Posts shall be anchored to concrete footings. 3.5 CLEANING AND PROTECTION A. After installation, clean soiled signs surface according to manufacturer's instructions. Protect from damage until acceptance. END OF SECTION 10425-5