National Accelerator Laboratory

Similar documents
National Accelerator Laboratory

National Accelerator Laboratory

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

Both single and double sided silicon detectors of dierent shapes and strips conguration, including prototypes. and wedge). These detectors, and other

The LHCb Vertex Locator : Marina Artuso, Syracuse University for the VELO Group

National Accelerator LaboratoryFERMILAB-TM-1966

&wf-9+/ob/--21*~~ II. Ron Harper and Robert A. Hike

The LHCb Silicon Tracker

Resolution studies on silicon strip sensors with fine pitch

Pixel hybrid photon detectors

THE MEASURED PERFORMANCE OF A 170 GHz REMOTE STEERING LAUNCHER

EUDET Pixel Telescope Copies

GA A22897 QUASI-OPTIC COMPONENTS IN OVERSIZED CORRUGATED WAVEGUIDE FOR MILLIMETER-WAVE TRANSMISSION SYSTEMS

STUDY OF NEW FNAL-NICADD EXTRUDED SCINTILLATOR AS ACTIVE MEDIA OF LARGE EMCAL OF ALICE AT LHC

ITk silicon strips detector test beam at DESY

Pixel sensors with different pitch layouts for ATLAS Phase-II upgrade

The BaBar Silicon Vertex Tracker (SVT) Claudio Campagnari University of California Santa Barbara

This paper describes the main design considerations and features of the SVT, and it presents preliminary noise results obtained when the detectors wer

Laser Surface Profiler

The Architecture of the BTeV Pixel Readout Chip

Test Beam Measurements for the Upgrade of the CMS Phase I Pixel Detector

Up-conversion Time Microscope Demonstrates 103x Magnification of an Ultrafast Waveforms with 300 fs Resolution. C. V. Bennett B. H.

Integrated CMOS sensor technologies for the CLIC tracker

Preparing for the Future: Upgrades of the CMS Pixel Detector

Monolithic Pixel Sensors in SOI technology R&D activities at LBNL

The CMS Silicon Strip Tracker and its Electronic Readout

Thin Silicon R&D for LC applications

Total Absorption Dual Readout Calorimetry R&D

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH A 1024 PAD SILICON DETECTOR TO SOLVE TRACKING AMBIGUITIES IN HIGH MULTIPLICITY EVENTS

Lecture 2. Part 2 (Semiconductor detectors =sensors + electronics) Segmented detectors with pn-junction. Strip/pixel detectors

A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University

GA A25836 PRE-IONIZATION EXPERIMENTS IN THE DIII-D TOKAMAK USING X-MODE SECOND HARMONIC ELECTRON CYCLOTRON HEATING

Introduction to Radar Systems. Radar Antennas. MIT Lincoln Laboratory. Radar Antennas - 1 PRH 6/18/02

Pixel detector development for the PANDA MVD

Sensor production readiness

Calibration of Scintillator Tiles with SiPM Readout

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades

K. Desch, P. Fischer, N. Wermes. Physikalisches Institut, Universitat Bonn, Germany. Abstract

Performance of a Single-Crystal Diamond-Pixel Telescope

`First ep events in the Zeus micro vertex detector in 2002`

Towards a 10 μs, thin high resolution pixelated CMOS sensor system for future vertex detectors

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Test-beam measurements on prototype ladders for the LHCb TT station and Inner Tracker

VELO: the LHCb Vertex Detector

Commissioning and operation of the CDF Silicon detector

The LHCb Vertex Locator (VELO) Pixel Detector Upgrade

A REGULATED POWER SUPPLY FOR THE FILAMENTS OF A HIGH POWER GYROTRON

Measurements With Irradiated 3D Silicon Strip Detectors

INFRARED MEASUREMENTS OF THE SYNTHETIC DIAMOND WINDOW OF A 110 GHz HIGH POWER GYROTRON

Detection of Targets in Noise and Pulse Compression Techniques

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

GA A25824 A NEW OVERCURRENT PROTECTION SYSTEM FOR THE DIII-D FIELD SHAPING COILS

SHADOWGRAPH ILLUMINIATION TECHNIQUES FOR FRAMING CAMERAS

GA A23281 EXTENDING DIII D NEUTRAL BEAM MODULATED OPERATIONS WITH A CAMAC BASED TOTAL ON TIME INTERLOCK

The High-Voltage Monolithic Active Pixel Sensor for the Mu3e Experiment

Design, fabrication and characterization of the first AC-coupled silicon microstrip sensors in India

Towards an ADC for the Liquid Argon Electronics Upgrade

Understanding the Properties of Gallium Implanted LGAD Timing Detectors

Five-beam Fabry-Perot velocimeter

Updating APVDAQ, a software designed for testing APV25 Chips. Andreas Doblhammer (e )

Development of Pixel Detectors for the Inner Tracker Upgrade of the ATLAS Experiment

GA A22577 AN ELM-RESILIENT RF ARC DETECTION SYSTEM FOR DIII D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

DEVELOPMENT OF THE PULSE TRANSFORMER FOR NLC KLYSTRON PULSE MODULATOR* Abstract

Design and performance of a high rate, high angular resolution beam telescope used for

CMOS Detectors Ingeniously Simple!

The ACT External HEPA Push-Through Filter Assembly. A. A. Frigo, S. G. Wiedmeyer, D. E. Preuss, E. F. Bielick, and R. F. Malecha

THE 110 GHz MICROWAVE HEATING SYSTEM ON THE DIII D TOKAMAK

Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade

The Status of the DELPHI Very. April 30,1996. e a b c e e. a d c e e. C. Mariotti, J. Masik, E. Margan, N. Neufeld, H. Pernegger, M.

Development of a monolithic pixel sensor based on SOI technology for the ILC vertex detector

A new strips tracker for the upgraded ATLAS ITk detector

k SLAC-PUB-7583 July 1997 Co/vF PULSE TRANSFORMER R&D FOR NLC KLYSTRON PULSE MODULATOR*

STUDY OF THE RADIATION HARDNESS OF VCSEL AND PIN ARRAYS

Sandia National Laboratories MS 1153, PO 5800, Albuquerque, NM Phone: , Fax: ,

National Accelerator Laboratory

Accelerator and Fusion Research Division Lawrence Berkeley Laboratory University of California Berkeley, CA 94720

Test (Irradiate) Delivered Parts

High Explosive Radio Telemetry System. Federal Manufacturing & Technologies. R. Johnson, FM&T; B. Mclaughlin, FM&T;

A monolithic pixel sensor with fine space-time resolution based on silicon-on-insulator technology for the ILC vertex detector

An ASIC dedicated to the RPCs front-end. of the dimuon arm trigger in the ALICE experiment.

Seminar. BELLE II Particle Identification Detector and readout system. Andrej Seljak advisor: Prof. Samo Korpar October 2010

A 130nm CMOS Evaluation Digitizer Chip for Silicon Strips readout at the ILC

UCRL-ID Broad-Band Characterization of the Complex Permittivity and Permeability of Materials. Carlos A. Avalle

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

Performance of Keck Adaptive Optics with Sodium Laser Guide Stars

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

Test Results of the HTADC12 12 Bit Analog to Digital Converter at 250 O C

Tracking properties of the two-stage GEM/Micro-groove detector

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors

Studies of silicon strip sensors for the ATLAS ITK project. Miguel Arratia Cavendish Laboratory, University of Cambridge


PoS(Vertex 2016)071. The LHCb VELO for Phase 1 Upgrade. Cameron Dean, on behalf of the LHCb Collaboration

Description and Evaluation of Multi-Geometry Silicon Prototype Sensors for the LHCb Inner Tracker

Performance of Smoothing by Spectral Dispersion (SSD) with Frequency Conversion on the Beamlet Laser for the National Ignition Facility

Detector And Front-End Electronics Of A Fissile Mass Flow Monitoring System

arxiv: v1 [physics.ins-det] 18 Apr 2013

BTeV Pixel Detector and Silicon Forward Tracker

Plans for RPC DHCAL Prototype. David Underwood Argonne National Laboratory

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Milestone Report

The LHCb VELO Upgrade

Transcription:

Fermi National Accelerator Laboratory FERMILAB-Conf-97/343-E D0 Preliminary Results from the D-Zero Silicon Vertex Beam Tests Maria Teresa P. Roco For the D0 Collaboration Fermi National Accelerator Laboratory P.O. Box 500, Batavia, Illinois 60510 October 1997 Submitted to Nuclear Instruments and Methods A and Published Proceedings of the 6th International Workshop on Vertex Detectors (VERTEX 97), Mangaratiba, Rio de Janeiro, Brazil, August 31-September 5, 1997 Operated by Universities Research Association Inc. under Contract No. DE-AC02-76CH03000 with the United States Department of Energy

Disclaimer This report was prepared asanaccount of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specic commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reect those of the United States Government or any agency thereof. Distribution Approved for public release; further dissemination unlimited.

FERMILAB-Conf-97/343-E Preliminary Results from the D-Zero Silicon Vertex Beam Tests 1 Maria Teresa P. Roco 2 for the D-Zero Collaboration Fermi National Accelerator Laboratory Batavia, IL. 60510 USA Abstract Extensive tests of the D-Zero silicon vertex detectors and the nal version of the SVX-II chip and readout electronics were performed at a test beam facility equipped witha2tesla magnet at FNAL. Preliminary results are reported on the performance of the SVX-II chip, charge collection properties, signal to noise ratio, cluster pulse height and spatial resolution. 1 Introduction Run II of the Fermilab Tevatron collider is scheduled to begin in 1999. With the proposed accelerator parameters we expect over a tenfold increase in the luminosity upto210 32 =cm 2 =s. In addition, the bunch crossing interval will decrease from 3.5 s to 132 ns. The D0 detector is currently being upgraded in order to optimize its physics reach in Run II. An integral part of the D0 upgrade [1], the silicon vertex detector [2] will be a critical component in the identication of tt events. Directly surrounding the beam interaction region, the silicon tracker has the capability to discriminate tracks originating from decays of long-lived particles and to precisely determine the primary interaction vertex. The design specications for the silicon detectors were chosen to give good spatial resolution, minimum noise in the readout electronics and maximum radiation tolerance. 1 Presented at the 6th International Workshop on Vertex Detectors (VERTEX '97), Aug. 31- Sept. 5, 1997, Mangaratiba, Rio de Janeiro 2 Email: roco@f nal:gov Preprint submitted to Elsevier Preprint

Recently, we have performed extensive tests of the silicon detectors at a test beam at Fermilab. Several single-sided silicon detectors and a prototype small angle double-sided detector were tested with the nal version of the SVX-II chip and the readout electronics. The readout frequency was set at 53 MHz. Preliminary results on the performance of the SVX-II chip, charge collection properties, signal to noise ratio, cluster pulse height and spatial resolution are presented for the single-sided test ladders. Studies on radiation damage eects based on tests performed on a previously irradiated detector are also shown. 2 Test devices and test beam setup The test devices included four beam telescope elements using six single-sided 50 m pitch silicon detectors operating at 35 V bias voltage. They are fabricated on n-type silicon of 300 m thickness. Each detector has 384 strips read out by three 128-channel SVX-II chips. The detectors are AC-coupled to the readout electronics by capacitors integrated directly onto each strip. The coupling capacitor is formed by a 200 nm dielectric (SiO 2 )layer between the strip implant and the Al metalization. Polysilicon resistors (2 M ) are used to bias the strips. Beam tests were performed at Fermilab N-West with a 125 GeV charged pion beam. The test beam setup is shown schematically in Fig. 1. Four detectors were used as vertical sensors (v) and two were used as horizontal sensors (h) providing six space points in x and y to measure the trajectory of the incoming beam particle. The coincidence of four scintillator counters located upstream and downstream of the telescope elements provided the beam trigger. To simulate the superconducting solenoid in the upgraded detector, the test beam setup included a magnet which can provide a ~ B eld of up to 2 Tesla. The magnetic eld is in the direction parallel to the detector strips. A test ladder, constructed by wire-bonding two detectors together, is mounted on a remotely controlled movable table allowing rotation around the vertical axis as well as translation in the horizontal and vertical directions perpendicular to the beam. Rotations around the horizontal axis are done manually. The reference frame is shown in Fig. 2 with the z-axis along the beam direction. The x-axis is parallel to detector strips. Two single-sided test ladders were tested including one previously irradiated up to 1 MRad. For angular dependence studies data were taken with the plane of the test detector rotated at several values of and. A partially instrumented prototype double-sided 2 o detector was also tested. Results for the double-sided detector will be presented in a later publication. 2

125 GeV beam π trigger counter 2T magnet trigger counter v v,h v,h v test detector in B field movable table Fig. 1. Test beam setup. Shown are four telescope elements and a remotely controlled movable table where test detectors are mounted. y θ scans x φ scans z 125 GeV π beam Fig. 2. The z-axis is parallel to the beam direction, while the x-axis is parallel to the detector strips. Data were taken with the plane of the test detector rotated for several values of and. The magnetic eld is in the direction parallel to the detector strips and can be varied up to 2 Tesla. 2.1 Readout System The charge on each silicon strip, stored as a voltage across a capacitor, is digitized by the SVX-II chip which is wire-bonded directly to the detector. The SVX-II chips are connected to a kapton/copper exible printed circuit, the High Density Interconnect (HDI), containing an 8-bit data bus, clock and control line traces, bypass capacitors, resistors for chip biasing, and a \tail" for external connections. Port cards control the operation of the SVX-II chips by sending clock pulses and control signals across an 8.5 m cable connected to the HDI. The SVX-II chips respond by sending channel and data information 3

back to the port cards. Data is sent to the VME Readout Buer(VRB) module via an optical link. A controller card in the VME crate acts as the interface between the VRB module and the rest of the data acquisition system. A more detailed description of the silicon vertex detector, the SVX-II chip and the readout electronics are given in [2] and in this proceedings [3]. 3 Single-sided Test Ladder Results Fig. 3. Test ladder cluster charge distribution for 125 GeV charged pions at normal incidence with B =2 Tesla. A most probable value of 25 ADC counts is obtained by tting a Gaussian convoluted Landau distribution. This corresponds to a signal to noise ratio of about 18. For each event the coherent baseline shift is obtained by tting the raw pulse heights distribution of all 128 channels of an SVX chip with a Gaussian. The raw pulse height ofevery channel is corrected for this baseline shift to obtain the pedestal. The average random noise level is the Gaussian width of the pedestal distribution. The values of N i of the same SVX chip are uniform with an average channel to channel variation typically less than 1 ADC count. A selection criteria was applied in order to separate signals from noise. The baseline corrected pulse heights of each channel are scanned for signals larger than ve times the random noise N of the channel. A cluster charge is dened 4

as the sum of this signal and the signals of all contiguous channels i above 2N. i The cluster position is dened as the charge centroid, x o = P Q ix i i, where Q i i the sum is over all the constituent strips. Clusters which include bad channels are excluded. Fig. 3 shows the cluster charge distribution of the single-sided test ladder for 125 GeV charged pions at normal incidence with B =2 Tesla. The signal to noise ratio S=N is dened as Q mp = N, where Q mp is the most probable value of the cluster charge. To determine Q mp the cluster charge in Fig. 3 is tted with a Gaussian convoluted Landau distribution as shown. Since the channel to channel variation of N i for the same SVX-II chip is small, the average is used in this analysis. A signal to noise ratio of about 18 was obtained for the single-sided test ladder. Data were taken at various and incidence angles and at various magnetic eld settings. For B = 0 (circles) and B = 2 Tesla (squares), the most probable value of the cluster charge is plotted as a function of in Fig. 4, in good agreement with the geometric scaling of Q with 1= cos shown as the dashed curve. The charge pulse height and the width of the pulse height distribution are independent of the magnetic eld. P Fig. 4. The cluster charge Q mp is plotted as a function of the incidence angle for B = 0 Tesla (circles) and 2 Tesla (squares) in good agreement with the geometric scaling of Q with 1= cos. 5

The spatial resolution was studied by performing an unweighted linear least squares t on the particle track using special alignment runs where the magnet was taken out of the beam line. There were three parameters used in the t corresponding to the four telescope elements (v coordinates) and excluding the second element, TBT2. The residuals, shown in Fig. 5, represent the dierence between the linear t and the measured position in TBT2. These residuals contain the contributions from the intrinsic resolution and the systematic uncertainty from multiple Coulomb scattering. Correcting for these contributions, we obtain a spatial resolution consistent with 10 m. Fig. 5. The residuals representing the dierence between the linear t and the measured position in telescope element TBT2. These residuals contain the intrinsic resolution and the systematic uncertainty from multiple Coulomb scattering. 4 Irradiated Test Ladder Results Wehave also tested a single-sided ladder whichwas previously irradiated up to 1 MRad 15% with 8 GeV protons at the Fermilab booster facility. This ladder was stored in room temperature for 4 months after irradiation. The ladder operated at a bias voltage of 120 V based on laser test stand measurements. Fig.6 shows the depletion voltage curve as a function of bias voltage, where the 6

y-axis is the number of counts normalized to unity. The irradiated ladder shows a much slower rise compared to the non-irradiated ladder. These measurements also show that the irradiated ladder was functional at greater than 200 V bias voltage and did not show any sign of breakdown. Fig. 6. Depletion voltage measurements from the laser test stand. The vertical axis is in arbitrary units normalized to one. The irradiated ladder shows a much slower rise compared to the non-irradiated ladder. From the test beam data for normally incident 125 GeV charged pions, the cluster charge Q mp with B =2Tesla was measured to be 30 % lower compared to the single-sided non-irradiated ladder. We also studied the dependence of the cluster charge and noise on the chip parameters such as the ramp trim and preamplier band width (PABW) z. Radiation damage eects include an increase in the detector leakage current and a corresponding increase in noise. We observed this increase by comparing the random noise, expressed in number of electrons referred to as the equivalent noise charge, plotted as a function of the PABW in Fig. 7 for both the irradiated and non-irradiated z For dierent bunch crossing or interaction times, the response or the bandwidth of the SVX-II preamplier is adjusted by means of internal switches and capacitors to provide the optimal preamplier output risetime and hence minimum noise. 7

single-sided test ladders. The irradiated ladder was operated at room temperature with a leakage current of 1 A/strip. The measured noise is consistent with being dominated by shot noise due to leakage current. 90 ns 350 ns Fig. 7. The random noise expressed in number of electrons, referred to as the equivalent noise charge, is plotted as a function of the preamplier bandwidth for both the irradiated and non-irradiated single-sided test ladders. 5 Summary We have performed extensive tests of the D0 silicon vertex system, with the - nal version of the SVX-II chip and the readout electronics, at a Fermilab test beam facility equipped with a 2 Tesla magnet. Under test beam conditions the system proved to work quite well. The study of the angular dependence of the cluster charge shows good agreement with the expected geometrical scaling with 1= cos. With a signal to noise ratio of 18 for the single-sided test ladders, the spatial resolution for perpendicular tracks is determined to be consistent with 10 m using an unweighted linear t. Studies on radiation 8

damage eects based on tests performed with a detector previously irradiated up to 1 MRad show a substantial increase in the depletion voltage and equivalent noise charge. Comparison with a non-irradiated ladder show that the cluster charge in the irradiated detector is degraded by as much as 30 %. From laser test stand measurements, we did not observe the breakdown of the irradiated detector for voltages up to 200 V indicating that the breakdown voltage was well above depletion voltage. These studies give us condence that the silicon vertex detector will function until the end of Run II. References [1] D0 Upgrade Technical Design Report [2] D0 Silicon Tracker Technical Design Report, D0-Note 2169 (unpublished) [3] see Ron Lipton's talk 9