Measuring is our strong point

Similar documents
PowerIT Power Transducer Series 50

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Data Sheet. RISH Master Record %THD

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Technical Data Sheet AMIK 300 / 301

Digital Multifunction Instrument - Rish Master 3440

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

PEM353. Universal measuring device

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

AMIK 200 / 201 Technical Data Sheet

LAUREL ELECTRONICS, INC.

Introduction DIN rail mounted electricity meters

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

sustainable savings that can be viewed directly on the internet

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Theta 20A / 20V. Technical Data Sheet. Special Features

Technical Data Sheet. x1000. kwh R Y B

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm

Monitoring Electric Network Via Internet

Side view View from below Rear view

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

PLA 33. Power line analyzer. User and service manual. version 2.4

Applications. diris_581_d_1_gb_cat. Multimeasurement. Currents

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

 Applications DIRIS A40 DIRIS A40 DIRIS A40. diris_581_e_1_gb_cat

Multimeter 500CVD21 RTU500 series

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

DIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm

Applications. diris_581_e_1_gb_cat

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

Energy Management Modular Power Analyzers Type WM2-96

POINTAX 6000L2 Point Recorder

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Product Guide. Transducers

Measuring centers MC7x0 series Multifunction Meter MC740

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

MT 560/UMT TRANSDUCER & ANALYZER

Technical Data Sheet

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

PQube 3 Specifications

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Electronic timer CT-SDE

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR


Theta Hz. Technical Data Sheet. Special Features

DIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis

ISOMETER IRDH575. Approvals

N. TEST TEST DESCRIPTION

UMG 509-PRO. Multifunction power analyser with RCM

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Paperless Recorder PR20

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Energy Management Three-phase energy meter with output modules Type EM4-DIN

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Universal measuring transducer

3-phase meter with direct connection and pulse or Modbus RS485 output

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Single phase meter with direct connection and pulse or Modbus RS485 output

DATA SHEET Selectable AC transducer TAS-311DG

Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE

EMU Electronic AG. Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) Fax +41 (0)

Transienten. Datenspeicher

N. TEST TEST DESCRIPTION

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Universal-Transducer Multi-E11-MU

UPM209 1/5A CT, 80A Multifunction three-phase meter

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

Moving Test - MT3000

Energy Management Modular Smart Power Transducer Type SPT-90

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

XP2-R Power and Reverse Power Relay

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Transcription:

Measuring is our strong point Power measuring transducers E L E CT R O N manufacturing & services X

About us In 2008 we established ElectronXx GmbH on the This catalogue presents our range of measuring basis of more than 50 years of experience in electronics production. We produce over 250,000 components a year in the federal state of North Rhine-Westphalia (NRW). transducers. In addition to technical details, you will find all order information in a clearly organized, tabular form. Thanks our many years of experience with these constantly improved devices, we can advise you on all aspects of the diverse areas of Our specialized area of competence encompasses electronics, printed board assembly and complete device assembly. Our clientele includes leading industrial application. We look forward to your inquiries! companies as well as innovative small and medium-sized enterprises. Yours, The Management Board 2

Our history 1950 1951 1958 1959 1968 1981 1982 1996 1999 2000 2002 2008 2009 Beginning of construction at Heiligenhaus location Start of production of "Mechanical Measuring Devices " under AEG First use of transistors Assembly of first printed boards Conclusion of cooperation agreement AEG - Hartmann & Braun AG Hartmann & Braun AG becomes management company of Mannesmann AG Assembly of first SMD components Hartmann & Braun AG is integrated into Elsag Bailey Takeover by ABB Electronics production is outsourced to a newly formed company, ABB Electronics GmbH ABB Electronics GmbH becomes a member of the ElectronicNetwork Group and Initially operates under the company name Elektronik Zentrum West GmbH and later as EN ElectronicNetwork Heiligenhaus GmbH Spinoff of EN ElectronicNetwork Heiligenhaus GmbH from the group and launch of ElectronXx GmbH We relocate to Velbert Visit us: www.electronxx.de or www.electronxx-shop.de 3

PTA 50 Analog power measuring transducer for current Preferred models for sinusoidal variables Power measuring transducer PTA 50 for current 3KDE485100L 1 0 0 2 0 0 Variants for sinusoidal variables Power measuring transducer PTA 50 for current 3KDE485100V 0 0 0 0 Rated current I nom = 1 A / 5 A 1 I nom = 1,2 A / 6 A 2 I nom = 2 A / 10 A 3 I nom = 2,4 A / 12 A 4 OA* No. I nom = x A / 5 * x A 9 403/404 or 404 Measuring ranges: 1 A / 5 A to 2,4 A / 12 A Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 signal 0 20 ma 2 0 10 ma 3 0 1 ma 4 0... xx.x ma, range: 0 < xx.x < 20 ma 6 406 0 1 V 7 0 10 V 8 0... xx.x V, range: 0 < xx.x < 10 V 9 408 Additional order information Certificates Quality test certificate DIN 55350-18- 4.1.1(confirmation of order conformity)4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3,4) 499 * Order Attachment 1) For preferred models the order no. printed in bold characters up to the L is sufficient 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTA 50 PTA50 power measuring transducers do not require any additional power supply. The measuring transducer receives it from the measuring signal. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-mean-square values. The analog output can only emit dead zero signals, i.e. the output signal can only take on a value > 0 with an input signal > 0. The input signal can be max. 12 A. The double measuring ranges are always composed of a rated current x and its 5-fold value. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 4

PTV 50 Analog power measuring transducer for voltage Preferred models for sinusoidal variables Power measuring transducer PTV 50 for voltage 3KDE485110L 0 1 0 2 0 0 Variants for sinusoidal variables Power measuring transducer PTV 50 for voltage 3KDE485110V 0 0 0 0 Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 600 V 6 OA No.. Measuring ranges : 100 V / 120 V to 600 V max. Accuracy class : 0.3% Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 U nom = x V / 1,2 * x V (2 measuring ranges only up to 250 V) 9 403/404 or 404 signal 0 20 ma 2 0 10 ma 3 0 1 ma 4 0 xx,x ma, range: 0 < xx,x < 20 ma 6 406 0 1 V 7 0 10 V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 408 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTV 50 PTV50 power measuring transducers do not require any additional power supply. The measuring transducer receives it from the measuring signal. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-meansquare values. The analog output can only emit dead zero signals, i.e. the output signal can only take on a value > 0 with an input signal > 0. The input signal can be max. 600 V. Up to a max. input signal of 230 V, a second measuring range can be added with 1.2 times the value, but up to a max. of 250 V. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 5

PTM 50-AS Analog power measuring transducer for current Preferred models for sinusoidal variables Power measuring transducer PTM 50-AS for current 3KDE485120L 1 0 2 1 0 0 Variants for sinusoidal variables Power measuring transducer PTM 50-AS for current 3KDE485120V 0 2 0 0 Rated current I nom = 1 A / 5 A 1 I nom = 1,2 A / 6 A 2 I nom = 2 A / 10 A 3 I nom = 2,4 A / 12 A 4 OA No. I nom = x A / 5 * x A 9 401/402 or 402 Measuring ranges : 1 A / 5 A to 2,4 A / 12 A Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 signal 4 20 ma 1 0 20 ma 2 0 10 ma 3 0 1 ma 4 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/406 0 1 V 7 0 10 V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-AS PTM50-AS power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-mean-square values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 12 A. The double measuring ranges are always composed of a rated current x and its 5-fold value. The auxiliary energy is 80...265 VAC (80...300 VDC). The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 6

PTM 50-VS Analog power measuring transducer for voltage Preferred models for sinusoidal variables Power measuring transducer PTM 50-VS for voltage 3KDE485130L 0 1 2 1 0 0 OA No. Variants for sinusoidal variables Power measuring transducer PTM 50-VS for voltage 3KDE485130V 0 0 0 0 Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 570 V 6 Measuring ranges : 100 V / 120 V to 570 V max. Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 U nom = x V / 1,2 * x V (2 measuring ranges only up to 250 V) 9 403/404 or 404 signal 4 20 ma 1 0 20 ma 2 0 10 ma 3 0 1 ma 4 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/406 0 1 V 7 0 10 V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the devic 4) This code no. is not printed on the rating plate or packaging PTM 50-VS PTM50-VS power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. Sinusoidal input signals are converted into proportional root-mean-square values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 570 V. The double measuring ranges are always composed of a rated voltage x and its 1.2-fold value. The auxiliary energy is 80...265 VAC (80...300 VDC). The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 7

PTM 50-AN Digital power measuring transducer for current Preferred models for non-sinusoidal variables Power measuring transducer PTM 50-AN for current 3KDE485140L 1 0 2 1 0 0 OA No. Variants for non-sinusoidal variables Power measuring transducer PTM 50-AN for current 3KDE485140V 0 0 0 Rated current I nom = 1 A / 5 A 1 I nom = 1,2 A / 6 A 2 I nom = 2 A / 10 A 3 I nom = 2,4 A / 12 A 4 I nom = x A / 5 * x A 9 401/402 or 402 Measuring ranges : 1 A / 5 A to 2,4 A / 12 A Accuracy class : 0,3 % Overvoltage category : III Degree of contamination : 2 Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 Power supply Uh = 19 72 V,50/60 Hz, 19 100 V DC 1 Uh = 80 265 V,50/60 Hz, 80 300 V DC 2 signal 4 20 ma 1 0 20 ma 2 0 10 ma 3 0 1 ma 4 0 20 ma / 4 20 ma 5 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/406 0 1 V 7 0 10 V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-AN PTM50-AN power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. As a result, even non-sinusoidal input signals are converted into proportional root-meansquare values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 12 A. The double measuring ranges are always composed of a rated current x and its 5-fold value. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 8

PTM 50-VN Digital power measuring transducer for voltage Preferred models for non-sinusoidal variables Power measuring transducer PTM 50-VN for voltage 3KDE485150L 0 1 2 1 0 0 OA No. Variants for non-sinusoidal variables Power measuring transducer PTM 50-VN for voltage 3KDE485150V 0 0 0 Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 570 V 6 Measuring ranges : 100 V / 120 V to 570 V max. Accuracy class : 0,3 % Overvoltage category : III Degree of contamination: 2 Dimensions: 22,5 x 99,0 x 107,5 Degree of protection: Terminals IP20 U nom = x V / 1,2 * x V 9 403/404 or 404 Power supply Uh = 19 72 V,50/60 Hz, 19 100 V DC 1 Uh = 80 265 V,50/60 Hz, 80 300 V DC 2 signal 4 20 ma 1 0 20 ma 2 0 10 ma 3 0 1 ma 4 0 20 ma / 4 20 ma 5 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/406 0 1 V 7 0 10 V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-VN PTM50-VN power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. As a result, even nonsinusoidal input signals are converted into proportional root-mean-square values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 570 V. The double measuring ranges are always composed of a rated voltage x and its 1.2-fold value. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 9

PTM 50-FN Digital power measuring transducer for frequency Preferred models for non-sinusoidal variables Power measuring transducer PTM 50-FN for frequency 3KDE485160L 0 1 2 1 0 9 OA No. Variants for non-sinusoidal variables Power measuring transducer PTM 50-FN for frequency 3KDE485160V 0 0 9 Rated voltage U nom = 100 V / 120 V 1 U nom = 110 V / 133 V 2 U nom = 230 V / 250 V 3 U nom = 400 V 4 U nom = 500 V 5 U nom = 570 V 6 Measuring ranges : 30 Hz to 80 Hz Accuracy class : 0,3 % Overvoltage category : III Degree of contamination: 2 Dimensions: 22,5 x 99,0 x 107,5 Degree of protection: Terminals IP20 U nom = x V / 1,2 * x V 9 403/404 or 404 Power supply Uh = 19 72 V,50/60 Hz, 19 100 V DC 1 Uh = 80 265 V,50/60 Hz, 80 300 V DC 2 signal 4 20 ma 1 0 20 ma 2 0 10 ma 3 0 1 ma 4 0 20 ma / 4 20 ma 5 0 xx,x ma, range: 0 < xx,x < 20 ma 6 405/406 0 1 V 7 0 10 V 8 0 xx,x V, range: 0 < xx,x < 10 V 9 407/408 Measuring ranges Specify starting value min. 30 Hz and max. 78 Hz in plain text 9 409 Specify end value min. 32 Hz and max. 80 Hz in plain text 9 410 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18^.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTM 50-FN PTM50-FN power measuring transducers require an additional power supply. The arithmetic mean is formed from the input variables. As a result, even non-sinusoidal input signals are converted into proportional root-meansquare values. The analog output can also emit live zero signals, i.e. the output signal can also take on a value > 0 (e.g. 4 ma) with an input signal = 0. The max. input measuring range is 570 V. The starting value of the measuring range can be min. 30 Hz and max. 78 Hz. The limits for the end value are min. 32 Hz and max. 80 Hz. The measuring transducers are set on a permanent basis by us and cannot be changed by the user. 10

PTK 50-1 Digital power measuring transducer for all power system variables, 1-phase Preferred models for all power system variables, root-meansquare value Power measuring transducer PTK 50-1, 1-phase 3KDE485170L 5 7 2 0 1 0 OA No. Digital power measuring transducer, parameterizable for all variables in single-phase power systems or power systems with same load 2 analog outputs 1 digital outputs Accuracy class : 0,3 % Overvoltage category : III Degree of contamination: 2 Dimensions : 45,0 x 99,0 x 107,5 Degree of protection : Terminals IP20 Varians for all power system variables, root-mean-square value Power measuring transducer PTK 50-1, 1-phase 3KDE485170V 0 Rated current I nom = 1 2,5 A / 2 5 A 5 I nom = 2,4 6 A /4,8 10 A 6 Rated voltage U nom = 75 150 V / 150 300 V 7 U nom = 150 300 V / 300 570 V 8 Power supply Uh = 19 72 V,50/60 Hz, 19 100 V DC 1 Uh = 80 265 V,50/60 Hz, 80 300 V DC 2 Counication with parameterization interface RS232 1 with parameterization interface RS232 and additionally RS 485 MODBUS RTU 2 Options Delivery without customer-specific parameterization 0 Delivery with customer-specific parameterization 1 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTK 50-1 These power measuring transducers require an additional power supply. The root-mean-square value is formed from the input variables. As a result, even non-sinusoidal input signals are converted into proportional root-mean-square values. The analog output is bipolar so, for example, power flow directions can also be identified via the sign. Live zero signals are possible, the output characteristic curve can also be selected as non-linear. The PTK50-1 power measuring transducer has 2 analog outputs and additionally 1 digital output (open collector). These measuring transducers are freely parameterizable. You will find further information in the separate parameterization manual. These power measuring transducers can optionally be equipped with a bus connection as well. You will find further information in the separate interface manual. An external PTD50 display can be connected to these power measuring transducers. 11

PTK 50-3 Digital power measuring transducer for all power system variables, 3-phase Preferred models for all power system variables, root-meansquare value Power measuring transducer PTK 50-3, 3-phase 3KDE485180L 5 7 2 0 1 0 OA No. Digital power measuring transducer, parameterizable for all variables in three-phase power systems 3 analog outputs 2 digital outputs Accuracy class: 0.3% Overvoltage category: III Degree of contamination: 2 Dimensions : 67,5 x 99,0 x 107,5 Degree of protection : variants for all power system variables, root-mean-square value Power measuring transducer PTK 50-3, 3-phase 3KDE485180V 0 Rated current I nom = 1 2,5 A / 2 5 A 5 I nom = 2,4 6 A /4,8 10 A 6 Rated voltage U nom = 75 150 V / 150 300 V 7 U nom = 150 300 V / 300 570 V 8 Power supply Uh = 19 72 V,50/60 Hz, 19 100 V DC 1 Uh = 80 265 V,50/60 Hz, 80 300 V DC 2 Counication with parameterization interface RS232 1 with parameterization interface RS232 and additionally RS 485 MODBUS RTU 2 with parameterization interface RS232 and additionally CAN-BUS on request 3 Options Delivery without customer-specific parameterization 0 Delivery with customer-specific parameterization 1 Additional order information Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) CH6 Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) 499 1) For preferred models the order no. printed in bold characters up to the L is sufficient 2) Max. permissible voltage at the terminals 300/600 V, to ground 600 V 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging PTK 50-3 These power measuring transducers require an additional power supply. The root-mean-square value is formed from the input variables. As a result, even nonsinusoidal input signals are converted into proportional root-mean-square values. The analog output is bipolar so, for example, power flow directions can also be identified via the sign. Live zero signals are possible, the output characteristic curve can also be selected as nonlinear. The PTK50-3 power measuring transducer has 3 analog outputs and additionally 2 digital outputs (open collector). These measuring transducers are freely parameterizable. You will find further information in the separate parameterization manual. These power measuring transducers can optionally be equipped with a bus connection as well. You will find further information in the separate interface manual. An external PTD50 display can be connected to these power measuring transducers. 12

Power 50 accessories Digital measuring transducers for all power system variables PTD 50 Display for PTK 50-1 and PTK 50-3 Material No.: 3KDE485013L-0010 Dimensions: 96,0 x 96,0 x 72,0 Panel cutout : 92,0 x 92,0 (tolerance: + 0,8 ) Matching power supply: 3KDE485013L-0001 PDM Process Data Manager Material No.: V49830A-01003 Software for parameterization of PTK 50-1 and PTK 50-3 as well as for visualization of the process data Software on CD contains DRC200, PDV200, DA200-M and HDA100 Accessories: Parameterization cable for measuring transducers, model range 50 Material No.: 3KDE485013-0006 serial interface adapter for LKS interface Accessories The PTD50 display serves to indicate the measured values of the PTK50-1 and PTK50-3 devices. It is connected to the device via the stereo jack plug cable provided. It receives its auxiliary energy via a plug-in power supply unit (we recoend: 3KDE485013L-0001). The order and selection of the measured values to be displayed takes place during parameterization of the PTK50-1 or PTK50-3. You will find further information in the operating manual ENA3KDE485000R4283 and data sheet ENA3K- DE485000R1003. 13

PTW 50 WEB-Server for PTK 50-3, extension of ixmeter@work WEB-Server PTW 50 3KDE48510V- 9 7 6 0 3 8 9 Logs Modbus for PTK 50 HTTP FTP SNMP (planned) SSL (planned) Telnet DHCP Connections Ethernet RS 232 via phone plug jack I/O-connections WEB-Server PTW 50 complementing the PTK 50-3. A smart meter ixmeter@work results in combination with the PTK 50-3. Dimensions : 22,5 x 99,0 x 107,5 Degree of protection : Terminals IP20 PTW 50 The PTW50 Web Server is designed as an extension of the PTK50-3 and enables direct connection to a local network or to the Internet via an integrated Web Server. The Web Server makes it possible to take the meter reading with any PC offering JAVA TM capability via a Web browser. Extensive analyses are also possible. You can display the current values for voltage, current, apparent power, active power and reactive power as well as the power factors at the three current-carrying phases online at one-second intervals. The measured values are shown in the form of bar charts for the instantaneous value (including minimum and maximum value) and as line graphs. With regard to indication of the electric utility rate, the unit can optionally display the cumulative costs as well as the costs incurred based on actual consumption projected for the next minute, hour or day. You can, of course, export these values in tabular form. The Web Server can temporarily store mean values of the measured data at minute, hourly and daily intervals without connection to a PC so that retroactive analyses are also possible. 14

PT-SU Universal power measuring transducer for all power system variables and for network synchronization Digital measuring transducer for all power system variables and synchroscope up to 4 analog outputs and 1 digital output Accuracy class: 0,5 % Overvoltage category: III Degree of contamination: 2 Dimensions: 105,0 x 95,0 x 130,0 Degree of protection: Terminals IP20 OA No. Power measuring transducer SU V28451A- 1 3 Bauform Add-on enclosure 1 Measuring circuit Alternating current or three-phase current, balanced load 1 Three-phase current, unbalanced load (universal model) 3 Three-phase current, unbalanced load or synchroscope 4 variables Rated voltage, star connection: 30 V UN 290 V, delta: 50 V UN 500 V 1 Rated voltage, star connection: 115 V UN 490 V, delta: 200 V UN 850 2 Rated current ( 0,2 A IN 1,5 A ) 1 Rated current ( 1 A IN 7,5 A ) 2 Power supply 100 240 V AC/DC 1 48 60 V AC/DC 2 24 V AC/DC 3 modules 1x ma / V; 1x binary 1 3x ma / V; 1x binary 2 4x ma / V; 1x binary 3 Interface LKS interface 0 RS 485 interface + LKS interface 1 Additional order information Factory-configured 691 Rated frequency 16 2 / 3 Hz 511 Rated frequency 400 Hz 512 Certificates Quality test certificate DIN 55350-18-4.1.1 (confirmation of order conformity) 4) Quality test certificate DIN 55350-18-4.2.2 (with test point logging) 3)4) Accessories Parameterization software Ibis E 3 6 0 1 0 6 1 3) Can only be ordered before production of the device 4) This code no. is not printed on the rating plate or packaging ZAV2 ZAV2 PT-SU Freely parameterizable measuring transducer for measurement of all relevant power current variables U, I, P, Q, S, cos φ, sin φ, φ, f, 4 analog outputs and 1 binary output, 4 integrated power counters Comparison of two rated voltages regarding amplitude, frequency and phase (synchroscope) Parameterization and counication via standardized interface. User-friendly parameterization software with online display of all measured variables Add-on enclosure for standard bus mounting Electrical safety according to European standard and/or IEC regulations Various characteristic curves Correct measurement even with distorted sinusoidal shape 15

Terminal connection diagrams The power consumption is considered to be a positive power flow direction. Currents and voltages that are not connected are not displayed. Single-phase alternating current (~)[PTA 50, PTV 50, PTM 50,...PTK50-.] Three-wire three-phase current, balanced load (3~1E) Three-wire three-phase current, unbalanced load (3~2E) Terminal connection diagrams ATTENTION The terminals of the power supply of a delta voltage are to be assigned as if it involved connection of star voltage (an artificial neutral point is formed internally in the measuring transducer). Example: You have a delta voltage of 400 V so the star voltage is 230 V. Therefore, the terminals (terminal labelling 600/300 V) of the lower voltage have to be assigned: terminals 2.2, 5.2 and 8.2 for L1, L2 and L3. 16

Four-wire three-phase current, balanced load (3N~1E) [PTK 50-1, PTK 50-3] Four-wire three-phase current, unbalanced load (3N~3E) [PTK 50-3] 17

Notices 18

Notices 19

Table of contents PTA 50 4 PTV 50 5 PTM 50-AS 6 PTM 50-VS 7 PTM 50-AN 8 PTM 50-VN 9 PTM 50-FN 10 PTK 50-1 11 PTK 50-3 12 PTK 50-accessories (PTD 50 und PDM) 13 PTW 50 (smart meter) 14 PT-SU 15 Accessories SU: Parameterization software Ibis E Terminal connection diagrams 16-17 15 EL E CT R O N manufacturing & services X ElectronXx GmbH Haberstrasse 46 D-42551 Velbert Germany Telefon: +49 2051 60721-0 Telefax: +49 2051 60721-65 E-Mail: info@electronxx.de Internet: www.electronxx.de or www.electronxx-shop.de ENA_3KDE4850000K01R05EN