Indicator (4digit) (5digit) 8-pin plug counter

Similar documents
И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

TA Series. Analog Setting Non-Indicating type, PID Control. Analog and non-indicating type, PID control, set temperature by dial.

Multi Function Timer with Free power, Compact size W38 H42mm

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

No mark Time-limit contact 1c Time-limit contact 2c,Time-limit contact A 1c+Instantaneous contact 1c(selectable) DIN W48 H48mm (4digit)

Solid-State Digital Counter H7AN

No-mark 12-24VDC X 1. Multi-input mode. DIN W72 H36mm DIN W96 H48mm (5digit) D Display Unit

Cylindrical type proximity sensor

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

DIN W48 H24mm, W72 H36mm Loop powered digital scaling meter [M4NS/M4YS Series]

Count/Time Totalizers

Self-Powered Counters H7ET

Model Display digit Size Output Power supply 24VAC 50/60Hz, 24-48VDC 9999 (4-digit) 1-stage setting

High Speed Response Type With Built-in Output Protection Circuit

High Speed Response Type With Built-in Output Protection Circuit

Opaque materials of Min. Ø60mm. Hysteresis - Max. 10% at rated setting distance

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

Y Type. W Type. AC voltage AC current

Area sensor with plastic case

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

New 1. Temperature unit P J K R. N Indicator. X 12-24VDC VAC 50/60Hz. Indicator Alarm/Sub output. I Indicator

No mark VAC 50/60Hz, VDC 1 12VDC 2 24VAC 50/60Hz, 24VDC. selectable by output operation mode

Series 10-ZSE30A(F)/10-ISE30A

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

GE Series. Model and Suffix code. Power Supply. Dimensions & Panel Cutout DANGER

Two outputs: contact and non-contact

Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

WHEN A PLC IS TOO MUCH, AND SPACE FOR

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Compact Preset Counter

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

APPENDIX APPENDIX A 1

Self-powered Counter

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

M4Y/M4W/M5W/M4M Series

Analog Timer TTL Series

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

T3S/ T3H/ T4M/ T4L. Digital switch setting type. Features. Ordering information T 3 S B 4 R P 4 C

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Multifunctional counter tico 772/773/774

Pulse Scaler for DIN Rail Attachment

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

Solid-state Timer H3DS

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Maximum Value for OEMs SM. NX70 High-speed Counters (NX70-HSC1, NX70-HSC2) User Manual

FX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

05/09/2012

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

2.1 General Specifications

Model Number Structure

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

02/11/2015

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

A new approach to static electricity countermeasures

Single-phase Voltage Relay

Field Network SRT Series

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Model Number Structure

Ultraminiature Photoelectric Switches with Self-contained Amplifier

02/11/2015

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

SPST-NO SPDT DPST-NO DPDT

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

0.01kV (0 to ±0.99 kv)

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Diameter ø50mm Shaft type Absolute Multi-turn Rotary Encoder

Process Meter. Applicable

Single-phase Current Relay

Fuzzy Temperature Controllers E5AF

Monitoring voltages of 3-phase 4 wires with a single unit

Digital Fiber-Optic Switches

Position Indicator with/without Limit Values

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

E2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information

Featuring a 100 μs sampling period and ±0.1% linearity

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

CompoBus/D-type Digital Controller

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Model Number Structure

Basic Composition. Merits. Presettable/Read-out Counter for High-speed Addition and Subtraction. Electronic. Counters. Maximum operating speed

Specification. Scanning Laser Range Finder C /6. Date:

QL55 Series Luminescence Sensor

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Simplified Operations for TM-3100 Series Digital Tachometer

Transcription:

8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC 5/6Hz, 12-2VDC universal Memory protection for 1years(Using non-volatile semiconductor) Selectable Up/Down for counting value Built-in Microprocessor Please read Caution for your safety in operation manual before using. Ordering information FS Item A Digit Specifications A B Single preset Indicator 9999(digit) 5 99999(5digit) FS 8-pin plug counter 출력회로의수 Min. input signal width input Input Approx. 2ms No-voltage input Impedance at short- : Max. 7kΩ Residual voltage at short- : Max. 1VDC Impedance at open- : Min. 1kΩ.5 to 5sec. Single preset FSA - Model Totalizer(Indicator) - FS5B Digit digit 5digit Digit size W.8 H7.6mm W H8mm AC Voltage type 1-2VAC 5/6Hz AC/DC Voltage type 12-2VAC 5/6Hz, 12-2VDC Allowable voltage range 9 to 11% of rated voltage AC Voltage type Indicator : Max..7VA Single preset : Max. 5.7VA(1-2VAC 5/6Hz) consumption Indicator : Max..5VA Single preset : Max. 5.5VA(12-2VAC 5/6Hz) AC/DC Voltage type Indicator : Max. 2.8W Single preset : Max. W(12-2VDC) Max. counting speed for CP1, CP2 Selectable 1cps/cps/2kcps/5kcps by internal DIP switch One-shot output time Control Contact Type SPST(1a) - output Capacity 25VAC A resistive load - Memory protection Approx. 1 years(when using non-volatile semiconductor memory) External power 12VDC ±1% 5mA max. Insulation resistance 1MΩ(at 5VDC megger) Di strength 2VAC 5/6Hz for 1 minute Noise AC power ±2kV the square wave noise(pulse width : 1μs ) by the noise simulator strength DC power ±5V the square wave noise(pulse width : 1μs ) by the noise simulator Vibration Mechanical.75mm amplitude at frequency of 1 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour Malfunction.5mm amplitude at frequency of 1 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 minutes Shock Mechanical m/s²(approx. G) in each of X, Y, Z directions for times Malfunction 1m/s²(approx. 1G) in each of X, Y, Z directions for times Relay Mechanical Min. 1,, operations - life cycle Electrical Min. 1, operations(25vac A at resistive load)- Environment Ambient temperature -1 to 55, storage: -25 to 65 Ambient humidity 5 to 85%RH, storage: 5 to 85%RH Unit weight Approx. 1g Approx. 12g Environment resistance is rated at no freezing or condensation. J-59

Connections FSA DC 5mA FS5B DC 5mA 5 5 6 6 NO CTACT OUT: 25VAC A 2 7 RESISTIVE 2 7 COM LOAD 1 8 1 8 V V Dimensions Bracket - + 8 1-2VAC 5/6Hz 12-2VAC 5/6Hz, 12-2DC 9.5 85 72.5 - + cut-out Min. 55 1-2VAC 5/6Hz 12-2VAC 5/6Hz, 12-2DC (: mm) 61.8 5 +.6 Min.65 5 +.6 (Sold separately) PG-8 8 21 16 PS-8 5 2.5 2 2-ø.5 1 1 ø25 7 5 J-6 Input connections No-voltage input(npn) Solid-state input(standard : NPN output type ) Contact input FS Series FS Series FS Series RL 1kΩ 5.kΩ 5.kΩ 5.kΩ Black Black V (NPN output) CP1, CP2(INHIBIT), input RL 1 kω Black R1 (NPN open collector output) Voltage input(pnp) FXY series is for no voltage input type, it is not available to count applying DC voltage from the external. For using PNP type, please use as the following to count. PNP output Please set R1 value to make the composed resistance of RL+R1 as Max. 7Ω is an impedance for short-. CP1, CP2(INHIBIT), input V PNP open collector output type FS Series FS Series 5.kΩ 5.kΩ Black R1 V V In case of PNP open collector output type, please connect lower than 7Ω of R1 to input terminal before using. V Please select the counting speed as cps when it is used for counter.

8 Pin Plug type Input & output connections 12VDC Description of inner DIP switches Total value of load capacity and current consumption should not be exceed current capacity(max. 12VDC 5mA) There is no output operation mode SW(No. 6, 7, 8) in FS5B. Max. counting speed PR18-5DN 8 7 6 1cps Setting function of decimal point the decimal point. Black 5 2 1 cps 2kcps 5kcps GND 2 operation mode 5 1 8 - + Memory protection(/) Max. counting speed N C(Not used) Up/Down mode 6 7 Load Up/Down mode Memory protection Please select proper capacity of load not to exceed contact capacity. Contact capacity : 25VAC A Max. Contact type : 1a The max. counting speed is upgraded as 8 DIP SW numbers. 1 5 Down mode Up mode Disable the memory protection Enable the memory protection RUN mode Press button for When "DP"is flashing, over sec., it advances one touch the Reset to decimal point setting button. mode. Changing the decimal point (Factory default) Set the position of decimal point using, button of digital switch. Return to RUN mode Press button for over sec., it returns to RUN mode. It returns to RUN mode if no button or digital switch is applied for 6sec. in decimal point setting status. The decimal point setting is existed in indication type. J-61

Counting operation of indication mode(indication model) Up mode Down mode +Max. display value +Max. display value -Max. display value operation mode One-shot output(.5 to 5sec.) Retained output mode () F F C R K P Q S Up mode Down mode Operation after count up The display value continues until reset signal is applied then output is held. Retained output will be maintained until Reset signal is applied. value and retained output are maintained until Reset signal is applied. The display value returns to reset start status when display value is reached to setting value. The display value is held until output is then returns to reset start status. The display value continues until reset signal is applied. The display value is held during oneshot output time, counting process is returned to reset start status as soon as output is. The display value continues during oneshot output time. Up input mode - is when ( value) (Setting value) Down input mode- is when ( value) (Zero) One-shot output time is set by front TIME adjuster. J-62

8 Pin Plug type Proper usage Reset function Reset In case of changing the input mode after ing the power, please take a external reset or manual reset. If reset is not executed, the counter will be working as previous mode. Reset signal width It is reset perfectly when the reset signal is applied during min. 2ms regardless of the contact input & solid-state input. 1 Error display Error signal Error description Returning method ERR Zero setting status Change the setting value to non zero status When Error is displayed, the output continues state. There is no Error function in indicator. Reset input 2 1: In case of a contact reset, it is reset perfectly if the time of reset signal is applied during min. 2ms even though chattering is occurred. 2: It can be input the signal of CP1&CP2 after min. 5ms from closing time of reset signal. power The power 12VDC which is provided to is built in it. Please use it under Max. 5mADC. Min. signal width 1 1 1 2 2 1: Please make duty ratio(/) 1:1. 1cps : Min..5sec. 2: Min. signal width cps : Min.16.7ms 2kcps : Min..25ms 5kcps : Min..1ms Max. counting speed This is a response speed per 1 sec. when the duty ratio (:) of input signal is 1:1. If the duty ratio is not 1:1, the width between and should be over min. signal width and the response speed is getting slower against input signal. If either or signal is shorter than minimum signal width, this product may not respond. Detach the case from body While pushing the Lock part with with driver to the front, push the terminal block. 1) Widen the lock toward outside, push the plug to the front. 8-pin plug 2) Detach the case. Push the terminal block to front part Please be careful to use with tools, it may cause injury. The inner voltage starts to rise up for the first 1ms after power on, the input may not work at this time. And also the inner voltage drops down for the last 5ms after power off, the input may not work at this time. 1ms The unstable time 5ms against the input signal. Ta Tb Ta Therefore Ta( width) and Tb( width) needed to be over min. signal width. Max. counting speed is 1/2 value of rated spec. when duty ratio is 1:. It can not respond if it is smaller than min. signal width(ta). J-6