8 Pin Plug type DIN W8 H8mm 8 Pin plug counter Features Upgraded counting speed : 1cps / cps / 2kcps / 5kcps Decimal point setting(fixed decimal point of display) Wide range of power : 1-2VAC 5/6Hz 12-2VAC 5/6Hz, 12-2VDC universal Memory protection for 1years(Using non-volatile semiconductor) Selectable Up/Down for counting value Built-in Microprocessor Please read Caution for your safety in operation manual before using. Ordering information FS Item A Digit Specifications A B Single preset Indicator 9999(digit) 5 99999(5digit) FS 8-pin plug counter 출력회로의수 Min. input signal width input Input Approx. 2ms No-voltage input Impedance at short- : Max. 7kΩ Residual voltage at short- : Max. 1VDC Impedance at open- : Min. 1kΩ.5 to 5sec. Single preset FSA - Model Totalizer(Indicator) - FS5B Digit digit 5digit Digit size W.8 H7.6mm W H8mm AC Voltage type 1-2VAC 5/6Hz AC/DC Voltage type 12-2VAC 5/6Hz, 12-2VDC Allowable voltage range 9 to 11% of rated voltage AC Voltage type Indicator : Max..7VA Single preset : Max. 5.7VA(1-2VAC 5/6Hz) consumption Indicator : Max..5VA Single preset : Max. 5.5VA(12-2VAC 5/6Hz) AC/DC Voltage type Indicator : Max. 2.8W Single preset : Max. W(12-2VDC) Max. counting speed for CP1, CP2 Selectable 1cps/cps/2kcps/5kcps by internal DIP switch One-shot output time Control Contact Type SPST(1a) - output Capacity 25VAC A resistive load - Memory protection Approx. 1 years(when using non-volatile semiconductor memory) External power 12VDC ±1% 5mA max. Insulation resistance 1MΩ(at 5VDC megger) Di strength 2VAC 5/6Hz for 1 minute Noise AC power ±2kV the square wave noise(pulse width : 1μs ) by the noise simulator strength DC power ±5V the square wave noise(pulse width : 1μs ) by the noise simulator Vibration Mechanical.75mm amplitude at frequency of 1 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour Malfunction.5mm amplitude at frequency of 1 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 minutes Shock Mechanical m/s²(approx. G) in each of X, Y, Z directions for times Malfunction 1m/s²(approx. 1G) in each of X, Y, Z directions for times Relay Mechanical Min. 1,, operations - life cycle Electrical Min. 1, operations(25vac A at resistive load)- Environment Ambient temperature -1 to 55, storage: -25 to 65 Ambient humidity 5 to 85%RH, storage: 5 to 85%RH Unit weight Approx. 1g Approx. 12g Environment resistance is rated at no freezing or condensation. J-59
Connections FSA DC 5mA FS5B DC 5mA 5 5 6 6 NO CTACT OUT: 25VAC A 2 7 RESISTIVE 2 7 COM LOAD 1 8 1 8 V V Dimensions Bracket - + 8 1-2VAC 5/6Hz 12-2VAC 5/6Hz, 12-2DC 9.5 85 72.5 - + cut-out Min. 55 1-2VAC 5/6Hz 12-2VAC 5/6Hz, 12-2DC (: mm) 61.8 5 +.6 Min.65 5 +.6 (Sold separately) PG-8 8 21 16 PS-8 5 2.5 2 2-ø.5 1 1 ø25 7 5 J-6 Input connections No-voltage input(npn) Solid-state input(standard : NPN output type ) Contact input FS Series FS Series FS Series RL 1kΩ 5.kΩ 5.kΩ 5.kΩ Black Black V (NPN output) CP1, CP2(INHIBIT), input RL 1 kω Black R1 (NPN open collector output) Voltage input(pnp) FXY series is for no voltage input type, it is not available to count applying DC voltage from the external. For using PNP type, please use as the following to count. PNP output Please set R1 value to make the composed resistance of RL+R1 as Max. 7Ω is an impedance for short-. CP1, CP2(INHIBIT), input V PNP open collector output type FS Series FS Series 5.kΩ 5.kΩ Black R1 V V In case of PNP open collector output type, please connect lower than 7Ω of R1 to input terminal before using. V Please select the counting speed as cps when it is used for counter.
8 Pin Plug type Input & output connections 12VDC Description of inner DIP switches Total value of load capacity and current consumption should not be exceed current capacity(max. 12VDC 5mA) There is no output operation mode SW(No. 6, 7, 8) in FS5B. Max. counting speed PR18-5DN 8 7 6 1cps Setting function of decimal point the decimal point. Black 5 2 1 cps 2kcps 5kcps GND 2 operation mode 5 1 8 - + Memory protection(/) Max. counting speed N C(Not used) Up/Down mode 6 7 Load Up/Down mode Memory protection Please select proper capacity of load not to exceed contact capacity. Contact capacity : 25VAC A Max. Contact type : 1a The max. counting speed is upgraded as 8 DIP SW numbers. 1 5 Down mode Up mode Disable the memory protection Enable the memory protection RUN mode Press button for When "DP"is flashing, over sec., it advances one touch the Reset to decimal point setting button. mode. Changing the decimal point (Factory default) Set the position of decimal point using, button of digital switch. Return to RUN mode Press button for over sec., it returns to RUN mode. It returns to RUN mode if no button or digital switch is applied for 6sec. in decimal point setting status. The decimal point setting is existed in indication type. J-61
Counting operation of indication mode(indication model) Up mode Down mode +Max. display value +Max. display value -Max. display value operation mode One-shot output(.5 to 5sec.) Retained output mode () F F C R K P Q S Up mode Down mode Operation after count up The display value continues until reset signal is applied then output is held. Retained output will be maintained until Reset signal is applied. value and retained output are maintained until Reset signal is applied. The display value returns to reset start status when display value is reached to setting value. The display value is held until output is then returns to reset start status. The display value continues until reset signal is applied. The display value is held during oneshot output time, counting process is returned to reset start status as soon as output is. The display value continues during oneshot output time. Up input mode - is when ( value) (Setting value) Down input mode- is when ( value) (Zero) One-shot output time is set by front TIME adjuster. J-62
8 Pin Plug type Proper usage Reset function Reset In case of changing the input mode after ing the power, please take a external reset or manual reset. If reset is not executed, the counter will be working as previous mode. Reset signal width It is reset perfectly when the reset signal is applied during min. 2ms regardless of the contact input & solid-state input. 1 Error display Error signal Error description Returning method ERR Zero setting status Change the setting value to non zero status When Error is displayed, the output continues state. There is no Error function in indicator. Reset input 2 1: In case of a contact reset, it is reset perfectly if the time of reset signal is applied during min. 2ms even though chattering is occurred. 2: It can be input the signal of CP1&CP2 after min. 5ms from closing time of reset signal. power The power 12VDC which is provided to is built in it. Please use it under Max. 5mADC. Min. signal width 1 1 1 2 2 1: Please make duty ratio(/) 1:1. 1cps : Min..5sec. 2: Min. signal width cps : Min.16.7ms 2kcps : Min..25ms 5kcps : Min..1ms Max. counting speed This is a response speed per 1 sec. when the duty ratio (:) of input signal is 1:1. If the duty ratio is not 1:1, the width between and should be over min. signal width and the response speed is getting slower against input signal. If either or signal is shorter than minimum signal width, this product may not respond. Detach the case from body While pushing the Lock part with with driver to the front, push the terminal block. 1) Widen the lock toward outside, push the plug to the front. 8-pin plug 2) Detach the case. Push the terminal block to front part Please be careful to use with tools, it may cause injury. The inner voltage starts to rise up for the first 1ms after power on, the input may not work at this time. And also the inner voltage drops down for the last 5ms after power off, the input may not work at this time. 1ms The unstable time 5ms against the input signal. Ta Tb Ta Therefore Ta( width) and Tb( width) needed to be over min. signal width. Max. counting speed is 1/2 value of rated spec. when duty ratio is 1:. It can not respond if it is smaller than min. signal width(ta). J-6