Simplified Operations for TM-3100 Series Digital Tachometer

Size: px
Start display at page:

Download "Simplified Operations for TM-3100 Series Digital Tachometer"

Transcription

1 Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display, BCD output, analog output, or comparator output) and can be customized by adding optional cards in order to match your application. TM-3110 TM-3120 TM-3130 TM-3140 Display only With BCD open collector output With analog output With comparator output This section describes the operation procedures for the above four standard models. For the measurement and calculation functions of the optional card TM-0350 (RS-232C/GATE), please refer to the complete instruction manual. Basic Concept The TM-3100 series has the following three basic concepts: Measures the frequency of the input signal and displays the results in various measurement items after calculation. By simply setting the unit of measurement item, the results are converted and automatically displayed. Two measurement modes, such as NORMAL (normal continuous measurement) and SS (measurement between start and stop timings), are available. If the system is to be used as a replacement of the TM-2100, TM-800, or TM-8000 series or as a general tachometer or speedometer, select the NORMAL (normal continuous measurement) mode. The SS measurement mode and optional TM-0350 (RS-232C/GATE card) are newly equipped functions. Measurement Mode (MEAS MODE) Two measurement modes of NORMAL and SS are available. 1. NORMAL mode In the NORMAL mode, measurement is continued with a specified update time interval (e.g.: 1 second) and displayed. The NORMAL mode is used for general rotation speed or line speed measurements. This mode is compatible with old models (TM-800/8000 and TM-2100 series) because the measurement method is the same

2 2. SS mode (Measurement between start and stop timing) The SS mode is used to measure the AVERAGE, MAX (maximum), and MIN (minimum) values in a measurement section. Depending on what condition of the start and stop measurement section is specified, either MANUAL or AUTO measurement is used. In the MANUAL mode, the measurement section is determined by the START and STOP switches (or by the external input of the TM-0350). In the AUTO mode, the measurement section is determined by the setup of the start condition and measurement time. The details are provided in later sections. MANUAL Measurement value (rotation speed, etc.) Start input (Key switch, external control terminal or RS-232C) Stop input SS measurement stopped SS measurement in progress (average, maximum, and minimum values) Time SS measurement stopped AUTO Measurement value (rotation speed, etc.) Start input (Key switch, external control terminal, or RS-232C) SS measurement start value SS measurement stop value (time) SS measurement stopped Ready for SS measurement SS measurement in progress (average, maximum, and minimum values) SS measurement stopped Time Caution: Be careful when you use the SS mode as the measurement mode, Normal or SS will affect the operation of the comparator and BCD output functions

3 Measurement Item and Calculation Formula The TM-3100 series tachometer measures the period (frequency) of the input signal. Process the calculation by using the measurement frequency with the value which sets at the measurement item as the coefficient value, and display with the specified unit. For example, when sets the number of pulses per rotation or the diameter of the roller, the rotation speed (r/min) or the circumferential speed (m/min) can be displayed. The measurement items and the calculation formula (parameters) are listed in the following table. Note that the unit conversion coefficient (K) is automatically processed according to the setup of the measurement unit. * K: Unit conversion coefficient (fixed coefficient for converting the display unit, e.g., seconds to minutes) Measurement Display Unit Calculation Formula Item ROTATION (Rotation Speed) r/s, r/min, r/h ROTATION = Measurement Frequency PULSE FACTOR K L.SPEED (Circumferential Speed) VELOCITY (Moving Speed) PERIOD (Period) TIMES (Number of Times) FREQ (Frequency) FLOW (Flow Rate) P.TIME (Passing Time) OTHER (Engineering Unit) mm/s, m/s, mm/min, L.SPEED = Measurement Frequency PULSE DIAMETER π m/min FACTOR K mm/s, m/s, mm/min, VELOCITY = Measurement Frequency PULSE DISTANCE FACTOR m/min, km/min, mm/h, K m/h, km/h s, min PERIOD = 1 Measurement Frequency K 1/s, 1/min, 1/h TIMES = Measurement Frequency FACTOR K Hz, khz FREQ = Measurement Frequency FACTOR K ml/s, ml/min, ml/h, l/s, l/min, l/h FLOW = Measurement Frequency FACTOR K s, min P.TIME = PROCESS LENGTH L.SPEED FACTOR K L.SPEED = Measurement Frequency PULSE DIAMETER π EU/s, EU/min, EU/h OTHER = Measurement Frequency FACTOR K Example use of FACTOR Assume that a decelerator is used and the rotation detector is fixed to the input axis. If it is desired to display the rotation speed of the output axis, setup the gear deceleration ratio as FACTOR. Generally, FACTOR is setup as

4 Setup Menu If the system is used for the first time, it is necessary to setup each menu item one by one. The following flow chart shows the sequence of basic control switch operations for each parameter setup. Note that the actual display item varies with the situation. Panel switches and the basic operations <Setup Mode: Main item > INPUT: Input parameter setup Menu Main item selection Select item MEASURE: Measurement parameter setup Save setup and move to next item To sub item setup MEASURE > MEASURE MODE: Measurement mode setup <Sub Item: Set value (example)> Move digit Setup value Save the setup value and move to next item - 4 -

5 Menu items There are eight menu items as follows, from INPUT to OTHER. Note that the OPTION menu will not be displayed when the TM-0350 (RS232C/GATE) option is not used. Measurement mode display OTHER: Other parameter setup Menu: Setup mode Setup for the input signal INPUT: Input parameter setup OPTION: Optional parameter setup Setup for the measurement method, item, and unit Setup for display method and measurement section MEASURE: Measurement parameter setup OUTPUT: Output parameter setup Setup for display digits and update period Setup for BCD, COMP, ANALOG, and other outputs FUNCTION: Calculation parameter setup DISPLAY: Display parameter setup Setup for the TM-0350 Setup for the RS232C and CONDITION - 5 -

6 Setup Flowcharts The following shows the flowcharts of each menu item setup. 1. INPUT (Setup for input conditions) The INPUT menu is used to setup the installation of the input signal. AC: Sine wave signal For MP-900/9000 series Electromagnetic detectors and other detectors DC: Pulse signal (rectangular wave) For MP-981, RP-721, RP rotary encoder, and other detectors PULL UP: Open-collector interface Switch Detector Signal waveform AC amplifier Electromagnetic detector DC amplifier PULL UP Electromagnetic detector (MP-981) Rotary encoder Photoelectric detector (LG-916/930) Proximity switch (open collector interface) Low pass filter OFF: No filter is used 100 Hz: LPF of fc = 100 Hz is enabled (when DC and PULL UP are enabled) 20 khz: LPF of fc = 20 khz is enabled (when AC is enabled) 2. MEASURE (Setup for measurement functions) In the MEASURE menu, setup the measurement method, measurement item, and associated measurement conditions. Generally use NORMAL mode Setup the measurement unit. Setup the number of pulses per rotation. Setup the roller diameter. Setup the distance per pulse. Setup the process passing length (mm) - 6 -

7 3. FUNCTION (Setup for the display method and measurement start/stop conditions) In the FUNCTION menu, setup the display method and measurement start/stop conditions. [When MEAS=NORMAL] [When MEAS=SS] OFF: Setup the no input signal period before the display shows zero. Setup the average number of changing the main display value into the moving average value. SS: Start and stop of measurement MANUAL: Manual start and stop AUTO: Setup condition SHORT: One hour or less measurement section with the data updated every 1 second. LONG: 30 hours or less measurement section with the data updated every 30 seconds. Setup the measurement section. 4. DISPLAY (Setup for the display) In the DISPLAY menu, setup the number of display digits and display update. 1 LINE: Single line display 2 LINES: Two-line display Main display only Main and sub displays Setup the measurement to be displayed on the second line. OBJECT: Displays the same value as on the main display. Setup the display digits after decimal point. Round off the specified digit and display. Ex. If the data is , it will be displayed as follows: OFF: , 1 DIGIT: , 2 DIGITS: Setup the display update interval. Setup the brightness of the fluorescent display - 7 -

8 5. OUTPUT (Setup for BCD, COMP, and ANALOG outputs) In the OUTPUT menu, setup the BCD, comparator, and analog output parameters. Select optional output function from BCD, comparator, and analog outputs. MENU switch Select data item for BCD output Setup the COMP 1 to 3 conditions. Setup the voltage (current) output range. UPPER, LOWER: Set the upper/lower limits for COMP 1 to 3. OK: output with normal operation ERROR: output with an operational error. Continuous comparator operation The output is held until reset. Setup the one-shot output pulse width Setup the amount of hysteresis for the comparator setup value. Setup the minimum time of the continuous time which satisfies the comparator condition Setup the display value that should correspond to 0 V output. Setup the output timing. Setup the display value that should corresponds to 10 V (full scale) output. COMP 1 (or 2 or 3), UPPER (or LOWER) Setup the update time of DA convertor. Setup desired comparator reference values (LOWER/UPPER for COMP 1 to 3). MENU button When the output zero/full has an error ZERO: Adjust to 0V. FULL: Adjust to 10V

9 6. OTHER (Setup for saving panel conditions) In the OTHER menu, setup the saving/loading of setup conditions, the RS-232C, and option list. The setup values are saved in a backup memory. In addition, the setup values can be saved in COND 1 to COND 4. Save the setup conditions. Load the conditions saved. Clear the backup memory. Display the list of version information and optional configuration data. (or DC) Saving the setup value 1. Backup memory The setup conditions of the main menu are saved in a backup memory. When the system is powered on, the setup conditions of the backup memory will be automatically loaded. 2. CLEAR Resets the setup conditions of the backup memory to the factory default values. 3. CONDITION The setup conditions of the backup memory can be saved as COND 1 to COND 4. The contents of COND 1 to COND 4 can be loaded to the backup memory by the LOAD operation. Key Protect Setup the Key Protection Press the COND/> switch on the front panel for more than 2 seconds. The message K.P. (Key Protect) will appear on the bottom center of the display, and the system will not accept any key operation. Cancel the Key Protection Press the COND/> switch on the front panel for more than 2 seconds. The message K.P. (Key Protect) will disappear from the bottom center of the display, and the key protection function will be cancelled

10 BCD Output To enable this function, an optional BCD output card (TM-0322 [open collector interface] or TM-0321 [TTL level interface]) is required. Note that the TM-0322 card is incorporated to the TM The measurement value (to be selected from instantaneous, average, maximum, and minimum values) will be delivered to the BCD parallel output in the 6-digit positive logic. The normal mode and request mode are available. BCD output terminal AA-8207 (BCD connection cable, 3 m) BCD terminal HDRA-E36MA+ (case) HDRA-E36LPTH (connector) 36-pin, half-pitch BCD pin assignment Pin Signal Pin Signal 1 BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, BCD output, Start input 8 BCD output, Stop input 9 BCD output, Reset input 10 BCD output, NC 11 BCD output, NC 12 BCD output, NC 13 BCD output, NC 14 BCD output, NC 15 BCD output, Data request 16 BCD output, NC 17 BCD output, Print command 18 BCD output, GND

11 Setup items related to the BCD output Setup item Setup value Remarks BCD MODE (BCD output mode) BCD OUTPUT (Output data content) REQUEST CONTINUE MAIN MAX MIN AVG Request mode Normal mode Normal output Maximum value output Minimum value output Average value output BCD output mode Normal (CONTINUE) mode BCD data Print command About 100 ms About 10 ms Request mode 50 ms or more Request signal About 10 μs BCD data Print command About 10 ms 50 ms or less BCD output specification BCD output Print command output Request signal Positive logic, 6-digit parallel output - TM-3120: Open collector output - TM-0321: TTL output Negative pulse TTL output (pulse width: about 10 ms) Negative pulse TTL input (trailing edge), 10 μs or more Caution: The print command outputs TTL level even for the TM

12 Analog Output For analog output, the TM-0330 (analog output card) is required. Note that TM-0330 card is incorporated to the TM Either voltage output or current output is selected for the analog output. The display value that corresponds to the full scale voltage (or current) can be setup freely. Analog output terminal Voltage/current output Common Not used Not used Not used Not used Setup items related to the analog output Setup item Setup value Remarks OUTPUT MODE VOLTAGE Voltage output (Analog output mode) CURRENT Current output 0-5V 0 to 5 V VOLTAGE RANGE 1-5V 1 to 5 V (Output voltage range) 0-10V 0 to 10 V CURRENT RANGE 4-20mA 4 to 20 ma (Output current range) 0-16mA 0 to 16 ma ANALOG ZERO (Analog zero value) to ANALOG FULL (Analog full value) to ANALOG UPDATE (Analog output update time) CALIBRATION (Analog output calibration) 10 ms, 20 ms, 50 ms 100 ms, 200 ms, 500 ms, 1 s ± 0 to 20% Adjustable for more than ± 20%, up to 100%

13 Analog output specification Output signal (Voltage/Current selectable) Output method Output voltage range Output current range 12 bit D/A conversion (The resolution depends on the setup value.) 0 to 10 V, 0 to 5 V, 1 to 5 V 4 to 20 ma, 0 to 16 ma Load resistance Voltage output 100 kω or more Linearity Current output 500 Ω or less ± 0.3% of F.S. Analog output calibration Voltage output ± 5 % of F.S. or more Zero drift Span drift Output update time Current output ± 3 % of F.S. or more ± 0.05 % of F.S. / C ±0.05 % of F.S. / C 10, 20, 50, 100, 200, 500 ms, 1 s Comparator Output For comparator output, the TM-0340 (comparator output card) is required. Note that the TM-0340 card is incorporated to the TM Three comparator outputs, COM 1, 2, and 3, are available. The mode is to be selected from AUTO (automatic recovery mode), MAINTENANCE (output hold mode), and PULSE (single-shot output mode). Either UPPER or LOWER judgment is made with the measurement value, compared with the setup value. It is also possible to setup the system to output the status of ERROR (operation error) or OK (normal operation). Note that the comparator output in the case of SS measurement will be synchronized with the measurement start/stop timing. Comparator output terminal Comparator 1 contact Comparator 1 contact Comparator 1 contact

14 Setup items related to the Comparator output Setup item Setup value Remarks COMP SETTING (Setup item) COMP WORKING (Judgment mode), for each comparator COMP UPPER (Upper judgment threshold), for each comparator COMP LOWER (Lower judgment threshold), for each comparator COMP MODE (Comparator mode) COMP HYSTERESIS (Hysteresis setup) SHOT PULSE WIDTH (Output pulse width) COMP DELAY (Delay time) COMP1 Comparator 1 COMP2 Comparator 2 COMP3 Comparator 3 MODE UPPER LOWER OK ERROR 0 to to AUTO MAINTENANCE PULSE ± 20% (in 1% increment) 10 to 2000 ms (in 10 ms increment) 0 to 1000 ms (in 50 ms increment) To comparator mode setup Upper limit setup Lower limit setup Short-circuit the relay when it is determined normal. Short-circuit the relay when it is determined error. Automatic recovery mode Output hold mode One-shot output mode Available only for the automatic mode. Available only for the one-shot output mode. Comparator output specification UPPER setup LOWER setup OK setup ERROR setup Output type Measurement mode COMP delay function Reset function 6-digit setup (Relay is ON when; UPPER display value) 6-digit setup (Relay is ON when; LOWER > display value) The relay is ON when both UPPER and LOWER output contacts are open. The relay is ON when any error occur other than the RS communication error. Single make contact output Three outputs of COMP 1, COMP 2, and COMP 3 (with one UPPER, LOWER, OK, or ERROR output) Selection of the comparator operation mode Automatic recover mode Output hold mode Shot output mode The comparator automatically recovers when the rotation speed is within the specified range. Comparator hysteresis Adds a hysteresis to the comparator reference value for recovery. The output status is held even after the rotation speed is returned to the specified range. OFF (factory default output), 10 to 2000 ms in 10 ms increments The comparator output is held for a period of time when the rotation speed is within the specified range. 0 to 1000 ms in 50 ms increments The comparator produces the output only when the reference value is exceeded continuously for a specified period. Returns to the comparator hold mode

15 Maximum rating Output interface Output update time DC: 30 V/1 A AC: 250 V/1 A Terminal block About 10 ms Comparator output specification 1. Comparator automatic recover mode: AUTO The comparator will continuously output the comparison result for the measurement value. For the judgment, a hysteresis can be setup to provide the difference between the rising edge (when the comparator turns ON) and trailing edge (when the comparator turns OFF). The following example shows the case when COMP 1 is setup to UPPER and COMP 2 is setup to LOWER comparators, with the rotation speed of 1000 r/min, and the hysteresis of 10%. Lights off (contact OFF) UP lights on (contact ON) Lights off (contact OFF) LO lights on (contact ON) Hysteresis Lights off (contact OFF) LO lights on (contact ON) Lights off (contact OFF) 2. Comparator hold mode: MAINTENANCE Once the comparison condition is satisfied, the result of comparator output will be held. When the RESET switch is pressed or an external reset signal is applied with optional TM-0350, the comparator output will be reset. Note that in the case of SS measurement, the reset function can be used only after the measurement is stopped. Lights off (contact OFF) UP lights on (contact ON) LO lights on (contact ON)

16 3. Comparator pulse output mode: PULSE When the comparison condition is satisfied, a single-shot output is operated within the setup period of time. For example, when the output pulse time (SHOT PULSE WIDTH) is setup to 50 ms, the system operates as shown in the following figure. Lights off (contact OFF) UP lights on (contact ON) Lights off (contact OFF) LO lights on (contact ON) Lights off (contact OFF) 4. Comparator output delay: COMP DELAY The comparator output turns on when the comparison condition is continuously satisfied for a period of time. This delay can be specified in any comparator mode. By using the comparator output delay function, a stable operation can be expected. For example, when the comparator output delay (COMP DELAY) is set to 50 ms, the comparator output will be turned on after the input level exceeds the UPPER reference level, while the output is held for the 50 ms period. Lights off (contact OFF) UP lights on (contact ON) Lights off (contact OFF) After 50 ms has passed 5. Comparator normal: OK Comparator error: ERROR Besides the UPPER and LOWER comparator setups, OK and ERROR setup is available. When OK is selected, it outputs when the system is operating normally. Conversely, when ERROR is selected, it outputs when the system is operating abnormally due to improper input signal or setup conditions. Comparator normal: OK When the system is normally operating, the contact is turned ON. When either one of other two comparators is operated, the contact is turned OFF (excluding the case ERROR is set). Comparator error: ERROR The contact will be turned ON when an error occurs (excluding the RS communication errors)

17 SS (start and stop) Measurement Either MANUAL or AUTO measurement mode can be used. In either mode, a single measurement is completed from the start to stop. When repeating the measurement, it is to be started again. 1. SS-MANUAL mode In the SS-Manual mode measurement, the average and other values are measured in the interval from the point when the START switch is pressed until the STOP switch is pressed. Measurement value (rotation speed, etc.) Start input (Key switch, external control terminal, or RS-232C) Stop input SS measurement stopped SS measurement in progress (average, maximum, and minimum values) Time SS measurement stopped 2. SS-AUTO mode In the SS-Auto mode, pressing the START switch sets the system ready for measurement. The measurement starts when the setup start condition is satisfied and stops when the setup stop condition is satisfied. Then, measures in the interval between the start and stop times. Example: When the condition is; START at 2000 r/min and STOP after 10 seconds If the START switch is pressed at the rotation speed of 1000 r/min, the measurement will start when it reaches 2000 r/min after gradual acceleration. Then, the average, maximum, and minimum values are measured in the passing intervals of 10 seconds. As another example, if the START switch is pressed at the rotation speed of 2500 r/min and the rotation speed is decreased to 2000 r/min, the measurement will be started at this point. Please be careful about the rotation speed when you press the START switch. The measurement value will be displayed on the sub display. Measurement value (rotation speed, etc.) Start input (Key switch, external control input, or RS-232C) SS measurement start value SS measurement stop value (time) 10 seconds SS measurement stopped Ready for SS measurement SS measurement in progress (average, maximum, and minimum values) SS measurement stopped Time

18 Main display and sub display When DISPLAY - 2 LINE is selected in the setup mode, the main display shows the NORMAL measurement value and the sub display shows either the average, maximum, or minimum value of the SS measurement according to the selected value. Examples of the main display in a single line mode and the main/sub display in the two line mode are shown as follows. Main Display of TM-3140 (with the comparator function) (1 LINE display mode) The display of instantaneous rotation speed is updated every 1 second. Main and Sub Displays of TM-3110 (display only) (2 LINE display mode) SS: Indicates while measuring the maximum value. MAX: Display of maximum value in the measurement section which updates every 1 second

19 Function Board The rear card slots A to D are assigned to specific boards: slot A for the comparator, slot B for BCD or RS-232C/GATE, slot C for analog output, and slot D for the input board. For the TM-3110 (display only), TM-3120 (open collector BCD output), TM-3130 (analog output), and TM-3140 (comparator output), the specific function cards are already mounted in the corresponding rear slots. Any vacant slot can be used for an additional function. For example, you can add TM-0340 comparator to a TM-3130 system. If it is desired to implement an additional function after the unit has been delivered, the unit must be returned to the supplier Label on lateral side Rear panel Optional unit DC POWER (12 to 24 VDC) Optional unit Instead of the BCD board, an RS-232C/GATE board can be assigned

20 Power source connection (1) Wiring to AC power source (2) Wiring to DC power source Wiring to AC power source 100 to 240 VAC, 50/60 Hz, 30VA MAX. White Black 12 to 24 VDC, 15VA MAX 50 mm or less Wiring to DC power source Green Function grounding AC power supply type Ferrite core Function grounding DC power supply type (TM-0301) Example connection wiring of INPUT signal Wiring to MX-700 series signal lines (signal cable for LG-916/930) Red Black Blue Green White (not used) To LG-916/930 Shield cable (For the instance, the shield cable is connected to the power earth terminal.) The shield cable is connected to the power earth terminal. However, this method is not applicable for the electromagnetic compatibility (EMC) requirements. For EMC compatibility, please refer to the instruction manual

21 General Specifications Input Amplifier input type AC/DC selectable AC amplifier Signal waveform Sine wave: 0.2 to 45 Vrms Signal voltage range Signal frequency range Square wave: 0.6 to 63 Vp-p 1 Hz to 100 khz DC amplifier Signal waveform Square wave of 5 μs or longer pulse width Signal voltage range Hi level: +4 to +30 V Lo level: 1 to +1 V Signal frequency range 0.1 Hz to 100 khz Time measurement 10 ms to 3600 s Input impedance 10 kω min. Input type Voltage/No voltage (open collector interface) Low pass filter OFF, fc = 100 Hz, or fc = 20kHz, selectable Input connector Terminal block Function/Calculation Calculation type Frequency calculation type Time reference Crystal oscillator (20 MHz) Rotation speed measurement Display value (±0.01%) ± 1 count accuracy The display value is the actual count value excluding the decimal point. Measurement time 10 ms + 1 cycle time (periodic calculation type) Auto zero OFF and 0.5 to 10 s (factory default: 1 s). See below. OFF, 0.5 s, 1.0 s, 2.0 s, 3.0 s, 4.0 s, 5.0 s, 6.0 s, 7.0 s, 8.0 s, 9.0 s, 10.0 s When the signal is not inputted for 11 seconds or longer, the display will be reset to zero, excluding the setup time. For the passing time measurement, a measurement error will be declared when there is no signal for 3600 seconds or longer. Rapid deceleration tracking When the input signal is reduced rapidly and the signal is not function inputted for around one second or longer, the measurement is automatically decelerated with this function and the display shows zero after around 11 seconds. Moving average OFF (factory default), 2, 4, 8, 16, 32, 64, 128 Peak hold function OFF (factory default), average, maximum, minimum Section data Holds the peak value during the section from start to stop of the measurement

22 Setup Panel condition memory Pulse setup Roller diameter setup Pulse distance setup Process line length setup Factor The measurement condition, which keeps the current conditions, and other four conditions are memorized. 1 to P/R 0.1 to mm 0.1 to mm 0.1 to mm E (-3 to 3) EU/PULS Display Display Fluorescent display tube Display update time Average display 0.2 s (factory default), 0.4 s, 0.5 s, 0.6 s, 0.8 s, 1.0 s to 10 s (in 1.0 s steps) Unit display Rotation speed (ROTATION) r/s, r/min, r/h Number of decimal points Selection of digits fixed to zero SIG indicator Error display Brightness selection Circumferential speed (L.SPEED) Moving speed (VELOCITY) Period (PERIOD) mm/s, m/s, mm/min, m/min mm/s, m/s, mm/min, m/min, km/min, mm/h, m/h, km/h s, min 1/s (cycles) (TIMES) 1/s, 1/min, 1/h Frequency (FREQ) Flow rate (FLOW) Passing time (P.TIME) Arbitrary engineering unit (OTHER) OFF (factory default) Selectable from 1, 2, and 3 digits Hz, khz ml/s, ml/min, ml/h, l/s, l/min, l/h s, min EU/s, EU/min, EU/h OFF (factory default); minimum of 1 or 2 digits Blinks in synchronization with input signal. - Backup memory error - Board error - Maximum input frequency exceeded - Maximum display digit exceeded - Memory full error - Setup value error LOW, MID, HI Output Pulse output Output voltage Hi: +4.5 V or more Lo: +0.5 V or less Output logic Load resistance Negative logic 100 kω or more

23 Power supply for detector Output voltage: 12 VDC ±10% Maximum output current 100 ma General specifications Power voltage 100 to 240 VAC, 50/60 Hz, 30 VA max. Power consumption TM to 19 VA Operating temperature range Storage temperature range Operating humidity range Storage humidity range Location of use Outer dimensions Weight Voltage resistance Insulation resistance Applicable standards TM-3120 TM-3130 TM-3140 ANALOG, BCD, COMP 0 to +50ºC -10 to +60ºC 30 to 80% (without condensation) 30 to 85% (without condensation) 13 to 21 VA 16 to 25 VA 12 to 21 VA 20 to 30 VA Indoors, up to an altitude of 2000 m 96 (W) 48 (H) 140 (D) mm or less Around 310 g AC 1500 V (Input to FG, 1 min.) 10 MΩ min. (with a DC 500 V mega) CE marking Low voltage directive EMC directive EN :2001 (2nd) Over-voltage category II, Pollution degree 2 EN : 2006, embedded board type Mark CE This mark declares compatibility to the applicable EC directive. This mark indicates the double insulation structure. Accessories Instruction manual 2 (Specification 1, Basic operation procedure 1) Mounting fixture 1 set

Digital Tachometer. TM-3100 series. Introducing a new digital tachometer with a clear display and ability to add functions separately and easily!

Digital Tachometer. TM-3100 series. Introducing a new digital tachometer with a clear display and ability to add functions separately and easily! Digital Tachometer TM-00 series Customize your tachometer with added function, which matches your own application. Highly compatible with personal computers and controllers. Provided with wide variety

More information

TM-2100 Series. Digital Tachometer INSTRUCTION MANUAL ONO SOKKI CO., LTD. SIG SIG SIG SIG DIGITAL TACHOMETER TM-2130 DIGITAL TACHOMETER TM-2110

TM-2100 Series. Digital Tachometer INSTRUCTION MANUAL ONO SOKKI CO., LTD. SIG SIG SIG SIG DIGITAL TACHOMETER TM-2130 DIGITAL TACHOMETER TM-2110 TM-2100 Series Digital Tachometer INSTRUCTION MANUAL DIGITAL TACHOMETER TM-2110 DIGITAL TACHOMETER TM-2130 SIG SIG TM-2110 TM-2130 DIGITAL TACHOMETER TM-2120 DIGITAL TACHOMETER TM-2140 SIG SIG LOWER 1

More information

Digital Tachometers/Sensors and Peripherals. LG/SP/MP/RP series FV/FT/PA/TM series

Digital Tachometers/Sensors and Peripherals. LG/SP/MP/RP series FV/FT/PA/TM series Digital Tachometers/Sensors and Peripherals LG/SP/MP/RP series FV/FT/PA/TM series Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that

More information

FT-2500 Advanced Tachometer Operation manual

FT-2500 Advanced Tachometer Operation manual FT-2500 Advanced Tachometer Operation manual ONO SOKKI CO., LTD. Simplified Operation Manual for FT-2500 Advanced Tachometer FT-2500 Advanced Tachometer is a new rotational speed indicator that analyses

More information

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display 5 1/2 Digit DMM Series Enabling Dual Input and Display R6451A/6452A R6451A: General-Purpose Low-Price DMM with Standard Functions R6452A: Full-Functional DMM with Dual- Channel Input and Dual Display (Photo

More information

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0. SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm

More information

PM 6669 High-Precision Frequency Counter Specifications

PM 6669 High-Precision Frequency Counter Specifications PM 6669 High-Precision Frequency Counter Specifications Product Home Features Specifications Models, Options & Accessories Measuring functions Definitions Input specifications Auxiliary functions TimeBase

More information

15. Specifications WF1947/WF

15. Specifications WF1947/WF 15. Specifications 15.1 Oscillation Mode...15-2 15.2 Waveform...15-2 15.3 Frequency, Phase...15-3 15.4 Output Characteristics...15-3 15.5 Signal Characteristics...15-5 15.6 Modulated Oscillation Mode...15-7

More information

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE HITEK POWER XR1000 1 KW X-RAY POWER SUPPLY MODULE Component power supply for industrial x-ray systems, elemental analysis equipment, x-ray diffraction spectrometers, and materials process monitoring applications

More information

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: DA3. Plug-in Signal Conditioners M-UNIT Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary

More information

Bipolar Output Working Standard

Bipolar Output Working Standard 6166 DC Voltage/Current Source 6½-digit working standard suitable for calibration High-accuracy and highly stable with bipolar output l Wide dynamic range and high resolution Voltage source: ±10nV to ±1200V

More information

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides

More information

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE HITEK POWER XR1000 1 KW X-RAY POWER SUPPLY MODULE The HiTek Power XR1000 series is a component power supply for industrial x-ray systems, elemental analysis equipment, x-ray diffraction spectrometers,

More information

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7 Page 1 of 7 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-701B /PM /AL Phase Marker Function Analysis Function 0 Without 0 Without With Y With 1 (When /ALY

More information

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5

VM-703 TACHOMETER & ECCENTRICITY MONITOR MODULE Page 1 of 5 Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec, code is not specified. ) VM-703 /NB1 /CSU /TRP /TB Non-incendive * 1 Custom set up Tropical spec. I/O terminal block for: 1

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5 02B ABSOLUTE VIBRATION Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec, code is not specified. ) 02B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor

More information

1. BP4620 SPECIFICATIONS

1. BP4620 SPECIFICATIONS 1. SPECIFICATIONS 1. SPECIFICATIONS 1-1 1.1 Specification Conditions 1-2 1.2 Output 1-3 1.3 Output Limiters 1-5 1.4 Signal Sources 1-6 1.5 Monitor Output 1-7 1.6 Measurement Functions 1-7 1.7 Sequence

More information

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

96M0374. Instruction Manual. Analog Sensor Controller. RD Series Instruction Manual Analog Sensor Controller RD Series 96M0374 Safety precautions This manual describes how to install the RD Series as well as its operating procedures and precautions. Please read this

More information

BS-3520 Digital Indicator

BS-3520 Digital Indicator BS-3520 Digital Indicator The Better Way for Weighing & easurements Table of Contents. Introduction...3 - Trait... 3-2 Warning... 4 2. Specification...5 3. External Size...6 4. Description on Front Panel...7

More information

1 Model 3153 Automatic Insulation Voltage Withstand Testing Voltage Control from a PC Full Remote Control All test parameters can be controlled by RS-232C or GP-IB, including test voltage, cut-off current,

More information

Digital Electric Micrometer. DEG2000 Instruction Manual

Digital Electric Micrometer. DEG2000 Instruction Manual Digital Electric Micrometer DEG2000 Instruction Manual Contents 1. Introduction 1 2. Main Features 1 3. Main Modes 1 4. Names and Functions of Controls and Parts 2 5. Specifications 9 6. Operation 11 6.1

More information

SPECIFICATIONS Digital Indicator 1. General

SPECIFICATIONS Digital Indicator 1. General SPECIFICATIS Digital Indicator 1. General The instrument is a digital indicator for the purpose of instrumentation, and suitable for the application in hopper, tank scale, and so on. 2. Specifications

More information

MTY (81)

MTY (81) This manual describes the option "d" of the SMT-BD1 amplifier: Master/slave electronic gearing. The general information about the digital amplifier commissioning are described in the standard SMT-BD1 manual.

More information

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5 DISPLAY VM-7 Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive Monitor Function

More information

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES

INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES 2001 INSULATION / VOLTAGE WITHSTAND TEST INSTRUMENT SERIES Safety Standards Measuring Instruments 3153 3159 3158 3154 ISO14001 JQA-E-90091 http://www.hioki.co.jp/ HIOKI company overview, new products,

More information

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520

INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520 INSULATION / WITHSTANDING Test Instrument series 3153/3159/ST5520 3153 3159 Not CE Marked ST5520 This electrical safety test instrument series is designed for insulation resistance and voltage withstand

More information

HITEK POWER OL600W SERIES

HITEK POWER OL600W SERIES 600 W HIGH VOLTAGE POWER SUPPLIES The HiTek Power OL600W series range of single output high voltage power supplies meets the exacting requirements found in electron beam, ion beam, and x-ray systems, as

More information

STEPPING MOTOR EMULATION

STEPPING MOTOR EMULATION OPERATING MANUAL SERIES SMTBD1 OPTIONAL FUNCTIONS (Version 2.0) European version 2.0 STEPPING MOTOR EMULATION OPTION C This manual describes the option "C" of the SMT-BD1 amplifier: Stepping motor emulation.

More information

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale. Electronics & Software Type 5080A... Multichannel Laboratory This universal laboratory charge amplifier can be used for force and torque measurements with piezoelectric dynamometers or force plates. Piezoelectric

More information

NI 6013/6014 Family Specifications

NI 6013/6014 Family Specifications NI 6013/6014 Family Specifications This document lists the I/O terminal summary and specifications for the NI 6013/6014 family of devices. This family includes the following devices: NI PCI-6013 NI PCI-6014

More information

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: 47LV. Digital Panel Meters 47 Series Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

An ideal AC Hipot Tester with low cost of ownership realized, built on more than 50 years of experience in market. Hipot (Withstanding Voltage) Tester

An ideal AC Hipot Tester with low cost of ownership realized, built on more than 50 years of experience in market. Hipot (Withstanding Voltage) Tester M O D E L T O S 5 2 0 0 An ideal AC Hipot Tester with low cost of ownership realized, built on more than 50 years of experience in market NEW Hipot (Withstanding Voltage) Tester AC Hipot Tester TOS5200

More information

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for sensors with incremental output Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer.

Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer. Digital Tachometers / Sensors and Peripherals Select the rotation detector/rotation display unit that is optimal for your needs from the wide range of products that Ono Sokki is proud to offer. Rotation

More information

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And

More information

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224 No. CP-SS-E // Dot Printing Model Smart Recorder SRF0// The Smart Recorder SRF 0// Dot Printing Model accepts DC voltage, thermocouple, resistance temperature detector (RTD), communications and ON/OFF

More information

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz 8 Pin Plug Type DIN W48 H48mm 8 Pin Plug Features Upgraded counting speed: 1cps / 3cps / kcps / 5kcps Selectable voltage input (PNP) method or no-voltage input () method Decimal point setting (fixed decimal

More information

n DC Voltage Measurement (DCV) 7461A n AC Voltage Measurement (ACV, ACV (AC+DC)) 7451A 7461A/7451A Additional error depending on the integration time

n DC Voltage Measurement (DCV) 7461A n AC Voltage Measurement (ACV, ACV (AC+DC)) 7451A 7461A/7451A Additional error depending on the integration time Specifications Unless otherwise specified, the measurement accuracy is guaranteed for one year under the following conditions: Temperature; 23±5 C, relative humidity; 85% or less (75% or less in resistance

More information

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B71-0173-11 CONTENTS USING THE PRODUCT SAFELY Ⅰ-Ⅳ 1. FEATURES... 1 2. SPECIFICATIONS... 2 3. FRONT AND REAR PANELS... 5 3.1. Front Panel... 5 3.2. Rear Panel...

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES 2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES Medium-voltage rack-mount power supplies Page 2 The MV2000 series high-performance, medium output

More information

SCC-FV01 Frequency Input Module

SCC-FV01 Frequency Input Module USER GUIDE SCC-FV01 Frequency Input Module Conventions The SCC-FV01 frequency input module is a frequency-to-voltage converter designed to measure signals from frequency-generating sensors and other periodic

More information

N30P DIGITAL PANEL METER

N30P DIGITAL PANEL METER N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,

More information

Specifications. PCI Bus. Analog Input Input Characteristics

Specifications. PCI Bus. Analog Input Input Characteristics Specifications A This appendix lists the specifications of the NI 6034E/6035E/6036E. These specifications are typical at 25 C unless otherwise noted. The first section provides the specifications for the

More information

4 K to 512 K words (2 n, n = 12 to 19) or 2 to 10,000 control points (linear interpolation between control points)

4 K to 512 K words (2 n, n = 12 to 19) or 2 to 10,000 control points (linear interpolation between control points) The values of items marked with *1 are guaranteed values. All other values are either nominal values or typical (typ.) values, and are not guaranteed. Conditions unless otherwise mentioned are as follows:

More information

Connection and Operation

Connection and Operation Connection and Operation LED Display Control Module Motor Regeneration Unit Terminals Power Connection Terminals Protective Earth Terminal Internal Potentiometer Acceleration Time Potentiometer Deceleration

More information

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology

High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-speed, High-Accuracy Digital Displacement Inductive Sensor EX-V Series High-speed Sub-micron Displacement Sensor with 40,000 Samples/sec. High Accuracy Inductive Gauging Technology High-Performance

More information

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395 GE Infrastructure Sensing Druck DPI 841/842 Frequency calibrator and Frequency loop calibrator User manual - K395 A1 B1 10 1 A 2 9 A 3 8 2 3 7 6 11 4 5 B1 12 A2 DPI 842 13 15 14 A3 19 18 17 16 27 20 21

More information

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value. Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable

More information

User s Manual Current Probe. IM E 2nd Edition IM E

User s Manual Current Probe. IM E 2nd Edition IM E User s Manual 700937 Current Probe 2nd Edition Introduction Thank you for purchasing the 700937 Current Probe. This Instruction Manual contains useful information about the instrument s functions and operating

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800 NOVOHALL Rotary Sensor non-contacting Series RSC-2800 Special features Non-contacting, magnetic technology Measuring range up to 360 Available with push-on coupling or marked shaft Simple mounting Protection

More information

High Speed Milliohm Resistance Meter

High Speed Milliohm Resistance Meter High Speed Milliohm Resistance Meter 20 mω to 23 MΩ wide resistance range 10 ms measurement time 0.03% accuracy 1 μω resolution Automatic thermal and electromagnetic noise rejection Programmable reference

More information

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental NOVOHALL Rotary Sensor non-contacting Series RSC2800 digital SSI, SPI, Incremental The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional

More information

DIGITAL STORAGE OSCILLOSCOPES

DIGITAL STORAGE OSCILLOSCOPES 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com DIGITAL STORAGE OSCILLOSCOPES Digital Storage Oscilloscope 100MS/s Acquisition (40MS/s 2 Acquisition) 100MHz 2 channel. OUTLINE

More information

Analog Timer TTL Series

Analog Timer TTL Series Analog r TTL Series Part Number Description TTL - ❶ ❷ ❸ ❶ Pin Type 8 : 8Pin Socket and Panel mounted ❷ Timing Mode A : A, A1, F1, I B : A, A1, B, F ❸ Supply Voltage 110/220VAC 24VDC 110VDC General Specification

More information

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A... Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric

More information

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS AIM & THURLBY THANDAR INSTRUMENTS TF960 TF930 PFM3000 High performance 3GHz and 6GHz frequency counters PFM3000-3GHz low-cost handheld frequency counter TF930-3GHz bench/portable universal counter with

More information

NI DAQPad -6020E Family Specifications

NI DAQPad -6020E Family Specifications NI DAQPad -6020E Family Specifications This document lists the I/O terminal summary and specifications for the NI DAQPad-6020E family of devices. This family includes the following devices: NI DAQPad-6020E

More information

7075 WAVEFORM GENERATOR SIGNAL SOURCE

7075 WAVEFORM GENERATOR SIGNAL SOURCE 2000 7075 WAVEFORM GENERATOR SIGNAL SOURCE Internal Sweep Sequence Functions Arbitrary Waveform Generator with Four Independently Controllable Channels The 7075 WAVEFORM GENERATOR includes both function

More information

HITEK POWER OLS10K SERIES

HITEK POWER OLS10K SERIES 10 KW HIGH VOLTAGE POWER SUPPLIES The HiTek Power OLS10K series range of single-output high voltage power supplies meets the exacting requirements found in electron-beam, ion-beam, and x-ray systems, as

More information

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase

More information

Model 6517B Electrometer / High Resistance Meter Specifications

Model 6517B Electrometer / High Resistance Meter Specifications VOLTS Accuracy (1 Year) 1 / C 2V 10µV 0.025+4 0.003+2 20V 100µV 0.025+3 0.002+1 200V 1mV 0.06+3 0.002+1 NMRR: 2V and 20V range > 60dB, 200V range > 55dB. 50Hz or 60Hz 2 CMRR: >120dB at DC, 50Hz or 60Hz.

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Power analyzers and Energy Meters Power Analyzer Type WM14-96 Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

MODEL SS - DIN-RAIL SPEED SWITCH

MODEL SS - DIN-RAIL SPEED SWITCH MODEL SS - DIN-RAIL SPEED SWITCH! SIMPLE ON-LINE TRIP FREQUENCY SETTING (USING ACTUAL INPUT SIGNAL OR FREQUENCY GENERATOR)! USER SETTABLE TRIP FREQUENCY FROM 0.1 Hz to 25 KHz! OVER-SPEED, UNDER-SPEED,

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),

More information

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications. Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

Safety Precautions. Copyright / Trademarks

Safety Precautions. Copyright / Trademarks Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User s Manual thoroughly before use. Make sure

More information

Publication Number ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR. User s Guide

Publication Number ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR. User s Guide Publication Number 101201 ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR User s Guide Introduction This user's guide is used for all models of ATFxxB series of DDS function generator. xx in the model number

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

SCC-DI01 Isolated Digital Input Module

SCC-DI01 Isolated Digital Input Module USER GUIDE SCC-DI01 Isolated Digital Input Module Conventions The SCC-DI01 is a single-channel, optically isolated digital input module that can sense AC and DC digital signals, including TTL, up to 30

More information

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)

More information

Racal Instruments. Product Information

Racal Instruments. Product Information Racal Instruments 6084A-104-DMM 1 GHz Digitizer and 7.5 Digit Digital Multimeter The Digitizer/DMM increases test system performance and density by packaging a 7.5 digit Digital Multimeter (DMM) together

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Model and

Model and Function Generator Model 72-14110 and 72-14111 0 Contents Function Generator... 0 Model 72-14110 and 72-14111... 0 Chapter 1 Safety Information... 3 1.1 Safety Terms and Symbols... 3 1.2 General Safety

More information

OSCILLOSCOPES. Oscilloscopes CS-5300 SERIES RS-232C OPTION OPTION CS-5370P/5370/5350 FEATURES OUTLINE. Photo: CS-5370P

OSCILLOSCOPES. Oscilloscopes CS-5300 SERIES RS-232C OPTION OPTION CS-5370P/5370/5350 FEATURES OUTLINE. Photo: CS-5370P Oscilloscopes 100MHz 2-Channel Programmable Oscilloscope ( With Digital Readout / Cursor) CS-5370P CS-5370 100MHz 3-Channel Oscilloscope ( With Digital Readout / Cursor) 50MHz 3-Channel Oscilloscope (

More information

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom SMARTWAVE Programmable AC/DC Power Source PRODUCT OVERVIEW of cycles for each segment, the user can

More information

Stepping Motor Station

Stepping Motor Station Stepping Motor Station PV-7300 System A single system can measure all seven of the characteristics important in a stepping motor, namely the -T characteristic, holding torque, detent torque, pull-in torque,

More information

LCSeries. Non-contact Speedometers SPEEDOMETER

LCSeries. Non-contact Speedometers SPEEDOMETER SPEEDOMETER Non-contact Speedometers LCSeries The LC-series is on-vehicle type of non-contact, non-marking speed measurement system with high accuracy. High-speed tests up to a maximum 320 km/h can be

More information

Torque Station Pro TS-7700 System

Torque Station Pro TS-7700 System For Motor Torque Measurement Torque Station Pro TS-7700 System The Torque Station Pro is designed to automatically measure motor torque characteristics. The compact configuration includes a built-in brake

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer ITN 1000-S ULTRASTAB I PM = 1000 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

Maxsine AC SERVO. EP100 QuickGuide. Maxsine Electric Co.,Ltd

Maxsine AC SERVO. EP100 QuickGuide. Maxsine Electric Co.,Ltd Maxsine EP100 QuickGuide AC SERVO Maxsine Electric Co.,Ltd 1.1 Standard wiring Position control Maxsine EP100(B) SERVO DRIVER SERVOMOTOR 3 Phase AC220V NFB MC PE R S T r CN2 U V W PE 14 5V 2 3 4 1 4 Pins

More information

DC Electronic Loads 8500 Series

DC Electronic Loads 8500 Series Data Sheet DC Electronic Loads 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating a variety of

More information

DM3100V2 Specifications

DM3100V2 Specifications DM3100V2 Specifications Analog input Number of slots 8-channel model: 4 (amplifier units can be intermixed) 16-channel model: 8 (amplifier units can be intermixed) Logic input Number of slots: 1 8 channels/unit

More information

Digital Indicators. K3HB Series (Pulse Input Series) Features

Digital Indicators. K3HB Series (Pulse Input Series) Features Digital Indicators K3B Series (Pulse Input Series) The K3B Series has been made complete with the addition of Digital Signal Input Models. Easy recognition of judgment results using two-color display that

More information

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Dual Channel Function/Arbitrary Waveform Generators 4050 Series Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary

More information

Arbitrary/Function Waveform Generators 4075B Series

Arbitrary/Function Waveform Generators 4075B Series Data Sheet Arbitrary/Function Waveform Generators Point-by-Point Signal Integrity The Arbitrary/Function Waveform Generators are versatile high-performance single- and dual-channel arbitrary waveform generators

More information

# Digital Multimeter

# Digital Multimeter #61-797 Digital Multimeter - 1 - TABLE OF CONTENTS 1.Introduction Precautions and Safety Information Symbols Safety 2.Specifications General Specifications Electrical Specifications Required Equipment

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

Torque Sensor Accessories and Services

Torque Sensor Accessories and Services ------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB

More information

TOS9200 SERIES Hipot Tester with Insulation Resistance Test

TOS9200 SERIES Hipot Tester with Insulation Resistance Test Perfect design for System Operation, introducing our top of the line of Hipot / Insulation Resistance Testers TOS9200(ACW/IR) TOS9201(ACW/DCW/IR) 4 Capable of performing hipot and insulation testing in

More information

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation User s Manual 701930 Current Probe Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the Current Probe (Model 701930). This instruction manual contains useful information

More information

Advanced Tachometer FT-2500

Advanced Tachometer FT-2500 // No rotational pulse signal is required for a measurement. The rotational speed is calculated from the frequency signal of light, magnetism, vibration, and sound. The is an advanced tachometer which

More information

Advanced Tachometer FT A digital tachometer that doesn't require. rotational pulse signals. FFT calculations performed by the device enable

Advanced Tachometer FT A digital tachometer that doesn't require. rotational pulse signals. FFT calculations performed by the device enable Advanced Tachometer A digital tachometer that doesn't require rotational pulse signals FFT calculations performed by the device enable measurement of rotational speed by sensing fluctuations in rotation-synchronized

More information