MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Similar documents
MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Hyperspectral MR-series FTIR Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

VSR VERSATILE SPECTRO-RADIOMETER FOR INFRARED APPLICATIONS PERFORMANCE WITHOUT COMPROMISE

Dario Cabib, Amir Gil, Moshe Lavi. Edinburgh April 11, 2011

Alexandrine Huot Québec City June 7 th, 2016

WIDEBAND HYPERSPECTRAL IMAGING FOR SPACE SITUATIONAL AWARENESS

High-performance MCT Sensors for Demanding Applications

Imaging Fourier Transform Spectrometry of Combustion Events Kenneth C. Bradley, Kevin C. Gross, and Glen P. Perram

SIGIS 2. Innovation with Integrity. Long Distance Identification, Visualization and Quantification of Gases FT-IR

INNOVATIVE SPECTRAL IMAGING

SIGIS 2. Innovation with Integrity. Long Distance Identification, Visualization and Quantification of Gases FTIR

Wind Imaging Spectrometer and Humidity-sounder (WISH): a Practical NPOESS P3I High-spatial Resolution Sensor

Int n r t o r d o u d c u ti t on o n to t o Remote Sensing

Hyperspectral goes to UAV and thermal

746A27 Remote Sensing and GIS

Outline for today. Geography 411/611 Remote sensing: Principles and Applications. Remote sensing: RS for biogeochemical cycles

RECONNAISSANCE PAYLOADS FOR RESPONSIVE SPACE

An Introduction to Remote Sensing & GIS. Introduction

SUPPLEMENTARY INFORMATION

AMIPAS. Advanced Michelson Interferometer for Passive Atmosphere Sounding. Concepts and Technology for Future Atmospheric Chemistry Sensors

Harmless screening of humans for the detection of concealed objects

Hyperspectral Sensor

An Introduction to Geomatics. Prepared by: Dr. Maher A. El-Hallaq خاص بطلبة مساق مقدمة في علم. Associate Professor of Surveying IUG

Hyperspectral Systems: Recent Developments and Low Cost Sensors. 56th Photogrammetric Week in Stuttgart, September 11 to September 15, 2017

746A27 Remote Sensing and GIS. Multi spectral, thermal and hyper spectral sensing and usage

METimage an innovative imaging radiometer for Post-EPS

Geo/SAT 2 INTRODUCTION TO REMOTE SENSING

High acquisition rate infrared spectrometers for plume measurement

NASTER System Definition Proposal

1. Theory of remote sensing and spectrum

Near-IR cameras... R&D and Industrial Applications

Hyperspectral Imager for Coastal Ocean (HICO)

THE SPACE TECHNOLOGY RESEARCH VEHICLE 2 MEDIUM WAVE INFRA RED IMAGER

Remote Sensing Platforms

Module 3 Introduction to GIS. Lecture 8 GIS data acquisition

ABB MEASUREMENT & ANALYTICS. TALYS ASP500 series Flexible analyzer for real-time control of chemical processes

Add CLUE to your SEM. High-efficiency CL signal-collection. Designed for your SEM and application. Maintains original SEM functionality

Development of four-dimensional imaging spectrometers (4D-IS)

A multispectral, high-speed, low-cost device in the UV-MWIR spectral range

Part I. The Importance of Image Registration for Remote Sensing

WHITE PAPER MINIATURIZED HYPERSPECTRAL CAMERA FOR THE INFRARED MOLECULAR FINGERPRINT REGION

John P. Stevens HS: Remote Sensing Test

Introduction to Remote Sensing

Cross Track Infrared Sounder (CrIS) Flight Model 1 Test Results

Remote Sensing 1 Principles of visible and radar remote sensing & sensors

Mid-Infrared Laser Heterodyne Systems From Earth Observation to Security and Defence. Damien Weidmann

Hyper-spectral, UHD imaging NANO-SAT formations or HAPS to detect, identify, geolocate and track; CBRN gases, fuel vapors and other substances

9/12/2011. Training Course Remote Sensing Basic Theory & Image Processing Methods September 2011

IMAGING RADIOMETER METimage FOR FUTURE OPERATIONAL EARTH OBSERVATION PLATFORMS IN POLAR ORBITS. Dr. A. Pillukat*, Dr. H.-P. Nothaft**, Dr. C.

Texture characterization in DIRSIG

CHARACTERISTICS OF REMOTELY SENSED IMAGERY. Radiometric Resolution

AVHRR/3 Operational Calibration

What Makes Push-broom Hyperspectral Imaging Advantageous for Art Applications. Timo Hyvärinen SPECIM, Spectral Imaging Ltd Oulu Finland

The studies began when the Tiros satellites (1960) provided man s first synoptic view of the Earth s weather systems.

Tunable wideband infrared detector array for global space awareness

Some Basic Concepts of Remote Sensing. Lecture 2 August 31, 2005

Norsk Elektro Optikk AS (NEO) HySpex Airborne Sensors System Overview

Current LWIR HSI Remote Sensing Activities at Defence R&D Canada Valcartier

FT-IR IMAGING THAT'S CLEARLY MEASURABLY AMAZING. Spotlight 400 FT-IR and 400N FT-NIR Imaging Systems

Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions

DEFENSE APPLICATIONS IN HYPERSPECTRAL REMOTE SENSING

Design and Performance of the Hyper-Cam, an Infrared Hyperspectral Imaging Sensor

MASSACHUSETTS INSTITUTE OF TECHNOLOGY LINCOLN LABORATORY 244 WOOD STREET LEXINGTON, MASSACHUSETTS

HYPERSPECTRAL IMAGERY FOR SAFEGUARDS APPLICATIONS. International Atomic Energy Agency, Vienna, Austria

NON-PHOTOGRAPHIC SYSTEMS: Multispectral Scanners Medium and coarse resolution sensor comparisons: Landsat, SPOT, AVHRR and MODIS

Getting Started. Spectra Acquisition Tutorial

REMOTE SENSING. Topic 10 Fundamentals of Digital Multispectral Remote Sensing MULTISPECTRAL SCANNERS MULTISPECTRAL SCANNERS

REMOTE CHARACTERIZATION OF CHEMICAL VAPOR PLUMES BY LWIR IMAGING FABRY-PEROT SPECTROMETRY. Presented at:

SR-5000N design: spectroradiometer's new performance improvements in FOV response uniformity (flatness) scan speed and other important features

Development of Chinese SI-traceable reference instruments and retrospective recalibration of historical satellite data

Introduction of Satellite Remote Sensing

Remote Sensing Calibration Solutions

Multispectral Scanners for Wildland Fire Assessment NASA Ames Research Center Earth Science Division. Bruce Coffland U.C.

Improving the Collection Efficiency of Raman Scattering

Remote Sensing Platforms

Concealed Objects Detection in Visible, Infrared and Terahertz Ranges M. Kowalski, M. Kastek, M. Szustakowski

Large format 17µm high-end VOx µ-bolometer infrared detector

Part 1. Introductory examples. But first: A movie! Contents

Govt. Engineering College Jhalawar Model Question Paper Subject- Remote Sensing & GIS

AN INTRODUCTION TO MICROCARB, FIRST EUROPEAN PROGRAM FOR CO2 MONITORING.

High Dynamic Range Imaging using FAST-IR imagery

Spectral Signatures. Vegetation. 40 Soil. Water WAVELENGTH (microns)

RADIOMETRIC CALIBRATION

Spectral and Radiometric characteristics of MTG-IRS. Dorothee Coppens, Bertrand Theodore

PRODUCT OVERVIEW FOR THE. Corona 350 II FLIR SYSTEMS POLYTECH AB

Gemini 8m Telescopes Instrument Science Requirements. R. McGonegal Controls Group. January 27, 1996

Blacksburg, VA July 24 th 30 th, 2010 Remote Sensing Page 1. A condensed overview. For our purposes

Place image here (10 x 3.5 )

Enhanced Chemical Identification Using High-Throughput Virtual-Slit Enabled Optical Spectroscopy and Hyperspectral Imaging

Microwave Remote Sensing

Observational Astronomy

NEC s EO Sensors and Data Applications

UNCLASSIFIED. UNCLASSIFIED R-1 Line Item #13 Page 1 of 11

Remote Sensing of the Environment An Earth Resource Perspective John R. Jensen Second Edition

ENMAP RADIOMETRIC INFLIGHT CALIBRATION, POST-LAUNCH PRODUCT VALIDATION, AND INSTRUMENT CHARACTERIZATION ACTIVITIES

Lecture 02. Introduction of Remote Sensing

High Accuracy IR Radiances-CLARREO Slide 1

Earth Exploration-Satellite Service (EESS) - Passive Spaceborne Remote Sensing

of the Small Satellite Mission Systematic Image Processing Eckehard Lorenz, DLR Berlin Ilmenau, Klaus Briess, TU Berlin 49th IWK

Lecture Notes Prepared by Prof. J. Francis Spring Remote Sensing Instruments

Transcription:

MR-i Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

FT-IR Spectroradiometry Applications Spectroradiometry applications From scientific research to deployable operational solutions, Fourier Transform Infrared (FT-IR) spectroradiometry has been established as an ideal technology to develop and enhance various military applications. For the defense industry, FT-IR spectroradiometry is used for: camouflage system development and thermal signature optimization; characterization of thermal emission signatures of aircraft engines; development, analysis and improvement of IR decoy emission spectra and advanced counter-measure systems; classifying fugitive emissions for developing infrared signature databases; classifying battlespace detonations, including bomb-hit detonation, muzzle flash, and missile launches; remote sensing of battlefield conditions for developing various deployable reconnaissance solutions. Schematized imaging Fourier transform spectroradiometer This powerful and innovative technique extends engineering modeling applications. It is also used to improve various types of IR emitting sources. FT-IR imaging spectroradiometers provide key information for modeling IR emitted source of energy and mapping the spatial evolution of the radiance. Combining the imaging spectroradiometer radiance measurement with retrieval algorithms enables the mapping of various atmospheric applications such as: meteorological turbulence sounding; atmospheric composition analysis; Stand-off detection and monitoring of a chemical cloud. Technology While conventional mono-pixel FT-IR spectroradiometers offer unique performance such as higher spectral resolution and enhanced sensitivity over the instrument field of view (FOV), multi-pixel FT-IR hyperspectral imagers now extend possibilities in infrared characterization. They provide accurate spatial characterization of a target s signature by spatially resolving the essential characteristics over the observed scene. The captured data is further exploited by combining the spectral and spatial information of the scene. As a result, an FT-IR imaging spectroradiometer has the unique capability of generating 3D images (2D images with spectral bands in the Z axis) providing a spectrum with every pixel of the mapped scene. IR characterization and modeling of a rocket plume 2 Hyperspectral Imaging FT-Spectroradiometers

The Forefront of Imaging Spectroscopy With over 35 years of innovation and being recognized as a world leader in spectroscopy, ABB is expanding its line of remote sensing products with a newly developed FT-IR hyperspectral imaging spectroradiometer. The MR-i features include the following. Proven robust design The MR-i is a commercial FT-IR imaging spectroradiometer. Its design is based on the ABB Bomem MR-Series spectroradiometers. It operates using the same MR304 / MR170 frictionless and rugged 4-port interferometer architecture. Dual-camera configuration The MR-i is the first commercially available FT-IR hyperspectral imaging spectoradiometer capable of dual-camera operation, simultaneously covering the MWIR and LWIR of the electromagnetic spectrum. The MR-i 4-port interferometer can accommodate a combination of two different types of camera modules (MWIR/LWIR), extending the instrument spectral range coverage or a combination of two identical camera modules (MWIR/MWIR), extending the instrument dynamic range. With this unique feature, the MR-i is capable of simultaneously acquiring and perfectly synchronizing the data of two interchangeable camera modules, making the instrument adaptable to multiple measurement scenarios. Sensitivity / extended dynamic range Some applications such as targeting an infrared signature often require simultaneous measurements of low and high intensity emission sources randomly dispersed over the mapped scene. The signal-to-noise performance of each individual detection module is affected by the integration time of the camera. Setting the integration time in respect to the energy level of the hot pixels will negatively impact the signal-to-noise performance of the cold pixels in the scene. On the other hand, having the integration time pre-set for maximum signal-to-noise performance of the cold pixels will cause saturation on the hot pixels. The MR-i offers an unmatched sensitivity for the characterization of a target s IR signature. With both ports equipped with detector modules covering the same spectral range (MWIR- MWIR or LWIR-LWIR), they can be individually set to different gains or integration time to extend the dynamic range of the instrument. This greatly enhances the brightest and faintest areas of the observed scene. Configuring the MR-i with two detection modules is like combining the functions of two imaging spectroradiometers in a single instrument, providing the following advantages: perfect synchronization of both cameras; ease of operation using one user interface; lower acquisition cost; lower maintenance costs. MCT Spectral Range InSb Spectral Range Cold Pixel Hot Pixel The MR-i dual detector broad spectral range Dynamic Range of an Observed Scene Hyperspectral Imaging FT-Spectroradiometers P 3

Fast scanning data acquisition rate The MR-i is the fastest commercially available FT-IR imaging spectroradiometer ever built. It generates the highest datacube measurement rate on the market. The MR-i is equipped with state-of-the-art cameras modules capable of the highest frame measurement rate available and is perfectly suited for the characterization of fast moving and rapidly evolving targets. The combination of both camera modules in a single instrument generates an unprecedented measurement rate and provides the best combination of spectral coverage, dynamic range, time resolution and spatial resolution performance ever seen on a COTS FT-IR imaging spectroradiometer instrument. Differential optical subtraction The MR-i can be configured with a linear array multi-pixel sensor optimised for differential acquisition in the VLWIR (cut off near 14µm). For this configuration, the instrument is equipped with a dual-input telescope capable of optical background subtraction. The resulting signal is the differential between the spectral radiance entering each input port, eliminating the clutter impact of the background. This specific configuration has been designed to support scientific research related to stand-off detection and identification of chemical agent threats. Differential optical subtraction The MR-i Spatial, Spectral and Time Resolution Modular / self-configurable instrument The MR-i can easily adapt to multiple applications. It is designed with user-configurable modular architecture, providing the user with the flexibility to adapt the instrument to the characteristics of a specific measurement scenario. The MR-i can be reconfigured by the user without the need for re-calibration or factory reworks by simply interchanging or combining various detection modules or input telescopes. 3 2 MR-i Modules 5 4 1 MR-i Spectroradiometer 2 Camera/detector module A 1 3 Camera/detector module B 4 Input telescope 5 Radiometric calibration sources 4 Hyperspectral Imaging FT-Spectroradiometers The MR-i Modular Design

MR-Series Heritage ABB designed multiple passive FT-IR radiometers based on high-resolution Fourier-Transform spectrometry for spaceborne applications. Today, ABB technology is used in various satellites for remote sensing applications such as: earth observation; climatology; atmospheric sounding. In spacecraft, ABB FT-IR radiometers are used to detect, identify and quantify each distinct species of gas in our atmosphere, based on the characteristics of their respective IR signatures. For over three decades, ABB has dominated the market by offering a comprehensive portfolio of highly reliable, rugged and field-proven FT-IR spectroradiometers used for various remote sensing applications. 15 years ago, ABB introduced the MR-Series FT-IR spectroradiometer for defense and atmospheric research organizations. There are now over 150 instruments routinely used throughout the world. MR-Series spectroradiometers have earned an excellent reputation based on: exceptionally high radiometric reproducibility; wavelength accuracy; high sensitivity; high spectral resolution; field operation reliability. The MR-i is the solution in hyperspectral imaging spectroradiometry. The MR-i is the only imaging spectroradiometer solution on the market offering: wide spectral range coverage; high dynamic range and signal-to-noise ratio; high time resolution; high spectral resolution; high spatial resolution; high accuracy; high reliability. The new MR-i The MR-i is built from the same proven technology and 4-port FT-IR configuration as used in the MR-Series spectroradiometers. ABB incorporated all the lessons learned and experience gained from the MR series when developing the new MR-i hyperspectral imaging spectroradiometer. This new spectroradiometer includes: newly developed acquisition and post-processing software modules; state-of-the-art IR cameras; improved optical configuration adapted for best imaging performances; our latest digitalization algorithms (time sampling). Hyperspectral Imaging FT-Spectroradiometers P 5

Contact us ABB Analytical Measurement 585 Charest Blvd East, suite 300 Quebec, (Quebec) G1K 9H4 Canada Phone: +1 418-877-2944 1 800 858-3847 (North America) Email: ftir@ca.abb.com Web: www.abb.com/analytical About ABB ABB Analytical Measurement continues to set the standards for FT-IR Spectroradiometry used in military, meteorological, and environmental applications. Building on more than 35 years of experience in Fourier spectrometers and optical instrumentation ABB s engineering department has the expertise and capabilities to efficiently serve customers interested in remote sensing aerospace applications. Its dedicated team of engineers offers the best solutions with reliable airborne and spaceborne instruments, infrared calibration systems, hyperspectral imagers, and software for ground segments and simulation. Printed in Canada 2011 Copyright 2011 by ABB. All Rights Reserved. Registered Trademark of ABB TM Trademark of ABB