X-EKB, X-ECH Electrical Cable Fasteners

Similar documents
X-EKB, X-ECH Electrical Cable Fasteners

X-ECT MX Electrical Cable Tie, X-EKS MX and X-EMTSC Conduit Clip Fastener

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

BX 3 system: fasteners for Interior Finishing, Mechanical and Electrical and Building Construction applications

X-HS Threaded Hanger and X-CC Loop Hanger Systems

X-P High Performance Nail for Fastening to Concrete and Wood to Steel applications

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Direct Fastening Systems. Hilti. Outperform. Outlast.

Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish

Drywall Applications. Electrical and Mechanical Fastenings

Fastener selection guide. Concrete fastener selection Selecting the right nail for concrete What determines nail performance

DIRECT FASTENING SYSTEMS. Hilti. Outperform. Outlast.

DIRECT FASTENING TECHNOLOGY MANUAL 2018

Drive Pins. Powder Actuated Systems. Powder Actuated Systems

Hilti, Inc South 122 nd East Avenue Tulsa, OK

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

Government Letters Job Reference 18 21

Material Specifications Technical Data

Hardware Fitting Accessories Accessories

Price list Connectors for floor reinforcement

Façade Solution. Produces façade & cassette solutions

Barofor Round System (polyester coated) Panels, Posts, Accessories

Using Hilti powderactuated. to install suspended metal-framed gypsum board ceilings. The application. Selection of fasteners.

Fastener Basics. Common Fastener Types. Fastener Materials. Grade / Class and Fastener Strength

DX-Kwik X-M6H, X-M8H Threaded Studs and DNH, X-DKH Nails

4isofast Product code Page

MASONRY DRILL and CHISEL

IFRC SHELTER TOOL KIT

Hilti HIT-1 / HIT-1 CE Adhesive Anchor System

OptiLine 45 Floor boxes

SPECIAL EXTRUSIONS AND ACCESSORIES

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

Powder Actuated Fasteners - Drive Pins

Tech Guide. Screw Anchor Performance Why use a screw anchor? Ease in installation

UNI DIN UNI DIN 7982.

Interior Construction Catalog Edition. On the job. Every day. Hilti. Outperform. Outlast.

CLIC TOP 17. Features

ANCHORHD- Heavy Duty Anchors RW List Prices Page L - 1. Vertigo (Sammy) Rod hangars. Cap Screws. Drop-In Anchors. Coach Screws.

TI: Efficient self tapping fasteners into concrete without plugs

Accessories for cable trunking

+ + CFA Guidance Note: Powder Actuated Fixing Systems. Ensuring best fixings practice. Contents. 1.

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

PRODUCT INFORMATION 0.145/0.130" 100 5,

FASTENERS BUILDING DEPARTMENT

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

FASTENERS & ACCESSORIES

Continuous Fastener Galvanizing

Ø 1250 * 688 mm 93 kg ± 105m

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Oct-18

77 cm. 5243/3-GA (3 pcs.) 5243/3-BO (3 pcs.)

Air-supply elements. Air-supply elements MGE Flanged plate (p. 5-3) M12-1/4" (p. 5-4) Longitudinal end connector (p.

FEET, WHEELS, FLOOR FASTENINGS, SUPPORTS

Air-supply elements. 5-2 MGE 13.1 Air-supply elements. 45x90. 45x90 (p. 2 41) Rexroth strut profiles can be used as compressed-air

European Technical Assessment. ETA-14/0426 of 15 December English translation prepared by DIBt - Original version in German language

DIN 934 (1987) NEN 1560 NF E25-401

ESR-2024* Reissued September 1, 2011 This report is subject to renewal September 1, 2013.

IMPERIAL BLADES ATTACHMENTS & BLADES IMPERIAL BLADES, INC. Replacements for:

HSL-3 / HSL-3-R EXPANSION ANCHOR. Technical Datasheet Update: Dec-17

Football Goals 7,32x2,44 m

Grinding and polishing discs COMBIDISC Corundum A Abrasive disc holders

Heatex Identification System. The Heatex Product Programme Offers:

Freestanding Shelving System

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

SOLDERING & BRAZING SOLDERING & BRAZING

Fastener Basics. Common Fastener Types. Fastener Materials. Grade / Class and Fastener Strength

METALPLAST-SOPRANA BRUINO TO VIA VOLVERA 88/4 TELEPHONE FAX

DRYWALL FASTENING SOLUTIONS

Z Order-No ½ ½ x

Clamp Pair. Bore Diameter (mm) Clamp Material PP = Polypropylene PA = Polyamide PE = Polyethylene AL = Aluminum

PROMPT TRADING CO. Ph. No.: FOR RESCUE

>> ACCESSORIES 5 2 METALPLAST-SOPRANA

Diagonal Cutters for plastics DIN ISO

Selection table for flat & ribbon cables

HPD Aerated concrete anchor. Approvals / certificates. Basic loading data (for a single anchor)

Please direct powder-actuated and screw fastening technical inquiries to your local Hilti Field Engineer or Technical Support at

Hilti X-BT Threaded Fastener Specification. Supplement 02/2012. X-BT threaded fasteners for use in nuclear power plants

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: ASTROTECH STEELS PRIVATE LIMITED

Wiha Professional. Quality down to the last detail. Diagonal cutters and heavy duty diagonal cutters. Diagonal cutters and stripping pliers.

Perfect sawing. The complete FEIN program for sawing: Jigsaws P Hacksaws P With the FEIN sabre saw through thick and thin with ease.

INSTALLATION INSTRUCTIONS BANO HEIGHT-ADJUSTABLE CISTERN

HEICO BEFESTIGUNGSTECHNIK HEICO-NAILS PRODUCT CATALOGUE

Ripple Construction Products Pvt Ltd

Rotary actuators Rotary wing drives Series RAK. Brochure

F I X I N G M AT E R I A L

METALPLAST-SOPRANA BRUINO TO VIA VOLVERA

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

SECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY

SKILL. Wall mounted. Bollard

HTC Grinding Guide.

SUBMITTAL SHEET. Project Submittals by

Magnetic sensor MSK320 Incremental, digital interface, resolution 12.5 μm, scaling factor 64 1

Use the arrow keys to easily navigate through the course.

NBI Technical Approval

European Technical Assessment. ETA-14/0426 of 21 December English translation prepared by DIBt - Original version in German language

Heat Shrinkable Tubing SA47, SA47-LA, SA47-HT

CARBIDE END MILLS SPECIFICATIONS

MEFA mounting accessories

Technical Data Sheet ACRYLIC FILLER 4:1 Acrylic filler with anti-corrosion additives RELATED PRODUCTS. Acrylic and polyurethane thinner

TO O L K IT. Public Bike Repair

Transcription:

X-EKB, X-ECH Electrical Cable Fasteners Product data Dimensions Single Fastener X-EKB 8/4-FR X-EKB 16 (FR) X-U 37 PH 1 2 4 o 8.15 16.8 10 21.5 34 136/104 16.8 10 25 229.7 37 49 o 11.8 X-ECH-S (FR) X-ECH-M (FR) X-ECH- (FR) 5 40 6 7 40 52 52 142.5 23.3 58 66 52 142.5 35.5 70 27 95 112.4 Magazine fastener X-EKB 4 / 8 / 16 MX (FR) X-EKB 4 MX (FR) X-ECH-B MX X-ECH-15/30 MX 8 8 13.5 10 15 48 63 67.7 X-GHP 20/24 X-GN 27 X-EGN 14 1.8 20/24 21.8 1.9 27 28.9 1.8 14 15.8 X-U 16/22/27 8 4 X-P 20/24 G3 MX 1.8 s X-C 27 G3 MX o 6.5 1.9 s X-S 14 G3 MX 1.8 14 15.8 2.4 X-P 22 Ø 4.0 s X-P 20/24 B3 MX X-S 14 B3 MX Ø 8.2 X-P: 1.8 s 1.8 14 15.8 2.4 s 12/2017 www.hilti.group 353

General information Material specifications See Fastener selection Recommended fastening tools DX 460-F8, DX 460 MX, DX 5 F8, DX 5 MX, DX 351-F8, DX 351 MX, DX36, DX 2, 120 ME, 3 ME, BX 3 ME See X-EKB, X-ECH fastener program in the next pages and Tools and equipment chapter for more details. Approvals U (USA): X-EKB MX, X-ECH / FR_U37 CSTB (France): X-EKB_U 37, X-ECH_U37 Note: technical data presented in these approvals and design guidelines reflect specific local conditions and may differ from those published in this handbook. Applications Examples X-EKB for fastening cables X-ECH for fastening bunched cables oad data Fastener capacity X-EKB: Securing electrical cables to concrete ceilings and walls Max. capacity (number of cables in one X-EKB) at spacing of 50 100 cm Number of wires/cables and wire sizes Designation NYM 3 x 1.5 mm 2 ( 8 mm) NYM 5 x 1.5 mm 2 ( 10 mm) X-EKB 4 4 3 X-EKB 8 8 5 X-EKB 16 16 10 354 www.hilti.group 12/2017

X-ECH: Securing electrical cable to ceilings and walls Max. capacity at spacing of 60 80 cm Designation No. of nails Number of cables X-ECH-S and X-ECH/FR-S max. 15 NYM 5x1.5 2 (Ø 10 mm) X-ECH-M and X-ECH/FR-M max. 25 NYM 5x1.5 2 (Ø 10 mm) X-ECH- and X-ECH/FR- max. 35 NYM 5x1.5 2 (Ø 10 mm) X-ECH-15 MX and X-ECH-B 1 or 2 max. 15 NYM 3x1.5 2 (Ø 10 mm) X-ECH-30 MX and X-ECH-B 1 or 2 max. 30 NYM 3x1.5 2 (Ø 10 mm) Conditions: For concrete C12/15 to C45/55 (f cc = 15 to 55 N/mm 2 ) All visible placing failures have to replaced Damaged X-ECH have to replaced Application requirements Thickness of base material Concrete X-U, X-P: hmin = 80 mm X-P G3 MX, X-P B3 MX, X-GHP MX, X-GN MX hmin = 60 mm Steel til 4 mm tii Thickness of fastened material Fasteners recommended for cable 8 mm and 10 mm Spacing and edge distances X-EKB: approximately 50 100 cm (Adjust as necessary to control cable sag) X-ECH: approximately 60 80 cm (Adjust as necessary to limit sagging) Corrosion information These zinc-coated fasteners are not suitable for long-term service outdoors or in otherwise corrosive environments. For further detailed information on corrosion see relevant chapter in Direct Fastening Principles and Technique section. 12/2017 www.hilti.group 355

Fastener program Fastener with pre-mounted DX-nail: Technical information Shank Shank Ø length Fastener ds s Designation [mm] [mm] Tools X-EKB8 U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Á X-EKB16 U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Ä X-ECH-S U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Å X-ECH-M U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Æ X-ECH- U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 À X-EKB4-FR U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 À X-EKB8-FR U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Á X-EKB16-FR U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Ä X-ECH/FR-S U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Å X-ECH/FR-M U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Æ X-ECH/FR- U 37 4.0 37 DX460-F8, DX 5 F8, DX351-F8, DX36, DX 2 Â, Ã All nail shanks: carbon steel, HRC 58, galvanized 2 20 µm Sleeve/thimble: carbon steel, not hardened, galvanized 5 13 µm See Product data in previous pages Fastener with pre-mounted DX-nail: Order information Designation Item no. Plastic material X-EKB 4-FR U37 361581 Polyamide 2 ) X-EKB 8 U37 386231 Polyamide 1 ) X-EKB 8-FR U37 386233 Polyamide 2 ) X-EKB 16 U37 386232 Polyamide 1 ) X-EKB 16-FR U37 386234 Polyamide 2 ) X-ECH-S U37 386235 Polyamide 1 ) X-ECH-M U37 386236 Polyamide 1 ) X-ECH- U37 386237 Polyamide 1 ) X-ECH/FR-S U37 386238 Polyamide 2 ) X-ECH/FR-M U37 386239 Polyamide 2 ) X-ECH/FR- U37 386240 Polyamide 2 ) 1 ) halogen and silicon free, light grey RA 7035 2 ) halogen and silicon free, flame retardant, stone grey RA 7030 356 www.hilti.group 12/2017

Fastener without pre-mounted nail: Technical information Base material Cable Holder Fastening Technology Nail Concrete X-EKB (FR) 4 MX X-EKB (FR) 8 MX X-EKB (FR) 16 MX X-ECH-15 MX* X-ECH-30 MX* Steel * To be used with or BX technology ONY BX DX DX BX DX X-P 20/24 G3 MX X-C 27 G3 MX X-GHP 20/24 MX X-GN 27 MX X-P 20/24 B3 MX X-U 22/27 MX X-P 22/27 MX X-S 14 G3 MX X-EGN 14 MX X-S 14 B3 MX X-U 16 MX Fastener without pre-mounted nail: Order information Fastener Plastic material Designation Item no. Electrical Cable Holder Polyamide 1 ) X-EKB 4 MX 285712 Polyamide 1 ) X-EKB 8 MX 285713 Polyamide 1 ) X-EKB 16 MX 285714 Polyamide 2 ) X-EKB FR 4 MX 285715 Polyamide 2 ) X-EKB FR 8 MX 285716 Polyamide 2 ) X-EKB FR 16 MX 285717 Polyamide 1 ) X-ECH-15 MX 2018247 Polyamide 1 ) X-ECH-30 MX 2018248 Polyamide 1 ) X-ECH-15/B MX 2018729 (kit) Polyamide 1 ) X-ECH-30/B MX 2018891 (kit) Polyamide 1 ) X-ECH-B MX 2018391 1 ) halogen and silicon free, light grey RA 7035 2 ) halogen and silicon free, flame retardant, stone grey RA 7030 12/2017 www.hilti.group 357

System recommendation DX tools: Steel: 6.8/11M red cartridge Concrete: 6.8/11M yellow cartridge on soft and tough concrete 6.8/11M red cartridge on very tough concrete Masonry: 6.8/11M yellow or green cartridge, green for MX Fastener 120-ME tool: Gas can GC 20. GC21 and GC22 3 ME tool: Gas can GC 40, GC 41 and GC 42 BX 3-ME tool: no gas can required Tool energy adjustment by setting tests on site. Fastening quality assurance X-EKB fastening quality X-ECH fastening quality h NVS h NVS h NVS = 7 ± 2 mm h NVS = 7 ± 2 mm 358 www.hilti.group 12/2017