SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

Similar documents
SECTION SIGNAGE

SECTION INTERIOR SIGNAGE

SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION IDENTIFYING DEVICES

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

A. Interior and exterior non-illuminated tactile building signs including Braille.

INTERIOR SIGNAGE MANUAL

APPENDIX 6. SIGNAGE TYPES: Signage as manufactured by KROY Sign Systems, N. Hayden Road, Scottsdale AZ 85260

BUILDING SIGN PROGRAM JULY 2012

A. Submit manufacturer's technical data and installation for each type of sign required.

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

SECTION FASCIA INTERIOR FRAMED SIGNS & DIRECTORIES

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

INTERIOR DESIGN INTENT DRAWINGS - condensed version

INTERIOR DESIGN INTENT DRAWINGS - condensed version

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Americans with Disabilities Act (ADA) Federal Guidelines

*********************************************************************************************************

A. Submit properly identified manufacturer's literature before starting work.

System / SignMatch. The Original Modular System and Winner of the Design of the Decade Award by the Industrial Designers Society of America 4.5.

BUILDING SIGN PROGRAM SEPTEMBER 2016

SECTION Display Case Door Series 1301-CM

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

BUS RAPID TRANSIT FOURTH PLAIN BLVD

SECTION FINISH HARDWARE

Product Guide Specification

1. ASME A Scheme for the Identification of Piping Systems.

50948-RHN Putney. 14 Dec This document includes: N14 General internal signage systems. Code Section Revision Dated

SECTION INTERIOR SIGNAGE

ETCHED PLAQUES by Matthews International

SECTION BULLET- RESISTANT DOORS

SECTION IDENTIFYING DEVICES

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

A. It is preferred that all submittals to be submitted electronically in PDF format.

Advisory Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges.

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Product Guide Specification

PHOTOPOLYMER BRAILLE RASTER BRAILLE MOLDED BRAILLE QUICK SHIP ADA BRAILLE SIGNS. Photopolymer sign panel in a variety of thicknesses.

CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

Tenant Sign Criteria. Guidelines. Requirements. Braelinn Village, Peachtree City

Table of Contents. Ninety Edge. BevelED Edge. Reveal Collection ENCLOSURES 7 KIOSKS 8 ARC ENCLOSURES 9 KIOSKS 10. Carve collection.

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

Healthcare Portfolio

SECTION MANUFACTURED CASEWORK

Addendum for 2018-COA-486 and 2018-COA-487 for the LeRoux and Cho 77 Projecting signs

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

SECTION HOLLOW METAL DOORS AND FRAMES

Mohawk Sign 2010 ARCHITECTURAL GRAPHICS CATALOG. A Sign of Quality Since 1946

SECTION WOOD ACCORDION FOLDING DOORS

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

UNISTRUT CORPORATION 2. AREA DIRECTLY ABOVE THE SUPPORT TO BE FREE AND CLEAR OF ALL OBSTRUCTIONS. 3. EXISTING STRUCTURE TO BE CHECKED BY OTHERS.

UNISTRUT CORPORATION 2. AREA DIRECTLY ABOVE THE SUPPORT TO BE FREE AND CLEAR OF ALL OBSTRUCTIONS. 3. EXISTING STRUCTURE TO BE CHECKED BY OTHERS.

Piping & Equipment Identification

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Summary of Modifications/Changes in this Update

Architectural Aluminum Frames

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION MECHANICAL IDENTIFICATION

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

SECTION WOOD DOORS

CITY OF RICHMOND Notice of Public Opening. Contract: Richmond Speed Skating Oval Interior/ Exterior Signage Package

SECTION SWINGING AUTOMATIC ENTRANCES

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA

Environmental graphics

PHOTOPOLYMER MATERIAL

Tufftec Lockers Specifications & Drawings SPECIFICATIONS & DRAWINGS

DOOR STOPS & BUMPERS See page 321 for finish descriptions.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION PANELBOARDS

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

GUIDELINE SPECIFICATIONS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

WAYFINDING TEAM For client review. St. Cloud State University

3400 Tectura Designs Precast Concrete

Bovard Studios Inc. Section April 6, 2004 Page 1

Interior Graphics Master Plan Display Manual

St. Monica Food Pantry

D. Product Certificates: Signed by manufacturers of casework certifying that products furnished comply with requirements.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

Guide Specification Section Interior Aluminum Doors and Frames

Work Type Definition and Submittal Requirements Work Type: Subsurface Utility Engineering (SUE)

ATTACHMENT B1. Typical Facility Signage Standards and Guidelines/Sign Types

Design and Construction Standards SECTION ATHLETIC LOCKERS

SECTION FOLDING GLASS PANEL PARTITIONS

Transcription:

SECTION 10445 NON-ILLUMINATED INTERIOR DISPLAY SYSTEM FullView Display System includes concealed pin lock device to secure a clear cover and/or sign insert material into the frame. Vandal resistant. PART 1 - GENERAL 1.01 SUMMARY. A. Unit prices: Provide installed unit price for each type unit in designed system for extra possible required signage. 1.02 REFERENCES A. Standards of the following as referenced: 1. American National Standards Institute (ANSI). B. Industry standards: 1. Department of Justice, Office of the Attorney General, "Americans with Disabilities Act", Public Law 101-336, (ADA). 2. ANSI A117.1: Providing Accessibility and Useability for Physically Handicap People, 1986 edition. 1.04 DEFINITIONS A. Terms: 1. Braille: Grade 2 Braille including 189 part-word or whole word contractions in addition to Grade 1 Braille 63 characters. Tactile is required whenever braille is required; see SYSTEM DESCRIPTION Article below. 2. Non-tactile: Letters and numbers on signs with width-to-height ratio between 3:5 and 1:1 and stroke width ratio between 1:5 and 1:10 using upper case "X" to calculate ratios. Use typestyles with medium weight; upper and lower case lettering is permitted; serif typestyles are permitted. See SYSTEM DESCRIPTION Article below. 3. Symbols: Symbol itself is not required to be tactile but equivalent verbal description is required both in tactile letters and braille. 4. Tactile: 1/32" raised capital letters without serifs at least 5/8" height and not more than 2" height based on upper case "X". Braille is required whenever tactile is required; see SYSTEM DESCRIPTION Article below. 1.05 SYSTEM DESCRIPTION A. Signage under this section is intended to include items for identification, control, and information of building where installed as complete integrated system from a single manufacturer. B. ADA Design Requirements: 1. Signage requiring tactile graphics: a. Wall mounted signs designating permanent rooms and spaces such as, room numbers and restroom, department, office, and fire exit identifications. b. Individually applied characters are prohibited. C. ADA performance requirements: Standards Page 1 of 5

1.06 SUBMITTALS 1. Tactile graphics signs mounting requirements: a. Single doors: Mount 60" to sign centerline above finish floor and on wall adjacent to latch side of door. b. Openings: Mount 60" to sign centerline above finish floor adjacent opening. c. No wall space adjacent latch side of door, opening, or double doors: Mount 60" to sign centerline above finish floor on nearest adjacent wall. A. Product data: 1. Manufacturer's signed statement regarding compliance with QUALITY ASSURANCE Article. 2. Manufacturer's product literature indicating units and designs selected. 3. Evidence of manufacturer's computerized data retrieval program for tracking of Project for sign typography, message strip requirements and other pertinent data from schedule input to final computerized typography on finished product. B. Shop drawings: 1. Indicate materials, sizes, configurations, and applicable substrate mountings. 2. Signage schedule complete with location of each sign and required copy; include floor plans, if required. C. Samples: Full size samples for holder, insert, and copy in colors specified. Provide sample in small size sign. Samples will not be returned for use in Project. MANUFACTURER HAS AVAILABLE SOFTWARE PROGRAM FOR PERSONAL COMUPTERS - PC, CALLED "SIGNWORD PRO" ENABLING END USER TO PRODUCE GRAPHICS ON INSERT OR SIGN FACE. D. Contract close out: 1. Furnish appropriate checklist for aiding in reordering after Date of Substantial Completion. 2. Maintenance data and cleaning requirements for exterior surfaces. 3. Furnish one complete SignWord software package Windows 3.0 or Windows 95 or later, Windows NT 4.0 or later in Owner selected format for PC type computer. 4. Furnish SignWord Color paper system. 1.07 QUALITY ASSURANCE A. Qualifications: 1. Manufacturer: a. Work required under this section from manufacturers regularly engaged in work of this magnitude and scope for minimum of five years. b. Maintain computer link between schedule input and computerized typography production. 1.08 DELIVERY, STORAGE, AND HANDLING A. Acceptance at site: Coordinate delivery of work to Project site under this section for immediate installation. 1.09 SEQUENCING AND SCHEDULING Standards Page 2 of 5

A. Schedule system installation after related finishes have been completed. PART 2 - PRODUCTS 2.01 MANUFACTURED UNITS A. Acceptable product: 1. APCO; FullView Display System; 17 Jennycliffe Lane, St. Louis, MO 63005. Sandy Ellis 636.386.8087, fax 636.386.8806. sellis@apcosigns.com 1. Standard Assembly Combination of extruded aluminum components, composite aluminum sheet and injection molded components, creating modular signs with a special, concealed pin lock device to secure a clear cover and/or sign insert material into the frame. Possible sign insert/display combinations include: Display - Non-Glare Acrylic Lens with Subsurface Paper Insert / Digitial Output - ADA (Tactile/Braille) Plaques Assembly allows for flexibility of size and configuration, providing a modular, vandal-resistant solution for signs ranging from single-insert identification signs to large directories and directional signs. a. Surface Mounted Signs (Wall): Attachment to wall surfaces via or concealed mechanical fasteners. 2.02 FullView Display Systems A. Modular Sign System with tamper proof locking pin for sign types: name plate, room/floor identification, directional use: 1. Standard Sizes (acrylic lens dimensions shown): Vertical Edge Configurations - Surface Mount: (aluminum edge profiles at left/right of sign) Sign Type A: FVS5585(V). 5.5 height x 8.5 wide. Standard Assembly FullView aluminum holder, Square profile, 5.5 x 8.5 Novacryl Clear ADA Photopolymer with room number tipped A01 white. Right color band, sub surface silkscreened, color as selected. Building name masked off so paper color shows through. Paper insert by MSU Sign Shop. NMS-4 Notifier bar below to hold notes. 8.5 length, natural satin finish. Sign Type B: FVS1185(V). 11 height x 8.5 wide. Standard Assembly Standards Page 3 of 5

FullView aluminum holder, Square profile, 11 x 8.5 Novacryl Clear ADA Photopolymer with room number tipped A01 white. Right color band, sub surface silkscreened, color as selected. Building name masked off so paper color shows through. Paper insert MSU Sign Shop. NMS-4 Notifier bar below to hold notes. 8.5 length, natural satin finish. Sign Type C: FVS0806(V). 8 height x 6 wide. Standard Assembly FullView aluminum holder, Square profile, 8 x 6 Novacryl Clear ADA Photopolymer with room name and symbols tipped A01 white. Sub surface background color as selected. 2. Color: Selected by Architect from manufacturer's standard NS- Natural Satin anodized (204R1) 3. Select from Edge Shapes: Square 4. Select Mounting Wall Signs: MF Mechanical Fasteners B. Graphics: 1. Type sizes: Selected from manufacturer's standard sizes indicated in SCHEDULES Article for particular units; meet ADA requirements for letter proportions and sizes. Clear coating on ADA bands or painted and tipped surfaces as required in Schedules Article. (ARN) Arial Narrow 2.03 FABRICATION A. Shop assembly: 1. Fabricate units to configurations indicated on reviewed shop drawings. Internally reinforce units in accord with reviewed shop drawings. 2. Wrap each individual unit with polyethylene. Provide special Suction Cup Removal Tool (SCT) and Locking Pin removal tool. PART 3 - EXECUTION 3.02 INSTALLATION A. Install signage holders in locations with mounting types indicated in accord with reviewed shop drawings. Square, plumb, and level units. B. Install inserts not more than 48 hours prior to Date of Substantial Completion complete with correct copy in place. Conform to ADA requirements for tactile graphics signage. Standards Page 4 of 5

3.03 CLEANING A. Clean exposed surfaces not more than 48 hours prior to Date of Substantial Completion in accord with manufacturer's written cleaning instructions. 3.04 SCHEDULES A. See attached sheet for Schedule. END OF SECTION 10445 Standards Page 5 of 5