Ø560*336mm 4.25 kg 2100 ± 105m

Similar documents
GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Ø 1250 * 688 mm 93 kg ± 105m

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Single-Armored Cables, Fibers

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Outdoor, Fig 8 Armored, Multi Tube

Optical Systems Contents

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Fibre Optic Indoor/Outdoor Cable

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Outdoor, CCTV or CCTV, Fig 8 Armored.

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

features and benefits

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Outside Plant All Dielectric

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Standard Monotube SAFE

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

Exhibit A Construction Project Manual and Drawings

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

Fiber Optic Outside Plant Cables (4-144 Fibers)

SPECIFICATION. Optical Fiber Cable

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Z EE E E Z E Z Z Z Z Z

Information technology. Generic cabling systems, General requirements

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Industrial Automation

Integrating Global Communications...

OFS AllWave non-dispersion shifted single-mode optical fiber

COPPER + LWL RAW CABLES

FiberHome Fiber Products

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

Category 6 A F/FTP Euroclass C ca Cables

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

Type QG-G50-2C- M-BU

Data, Network and Bus Technology

u n a B Optical Cables UNIFLEX CABLES LTD.

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

Nufern 980 nm Select Cut-Off Single-Mode Fiber

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

Datasheet Outside Plant Cable

Connection technology for wireless communication systems

Category 6 UTP EuroClass C ca Cables

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

NETWORK CONNECTIVITY SYSTEMS

FTTH Fiber Optical Cable

Electric cables. Cranes

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Application of Ultra-Low Bending Loss Fiber PureAccess-R5 to Optical Wiring in FTTx Access Networks

Jumper cable. Feeder cable + connector. Cable clamp. Grounding kit

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Install & Go Cat.8 STP Trunk Cable Assembly Description

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

Medium Voltage Power Cables

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Why Using Fiber for transmission

Fiber Optic Principles. Oct-09 1

Multi Fiber Cable Assemblies

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

Migration to 50/125 µm in the Local Area Network

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

GIGABIT ETHERNET. e-ready Building Next Generation IT infrastructures. The Cabling Partnership. Mike Gilmore Managing Director, e-ready Building

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

kv: medium voltage reeling cable with fibreoptics

Technical specification SiMTaCS Single Mode Tactical Cable System

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Cabling, FP PRO-series

CommunicationCables FIBER OPTICS OPGW FTTH

14 AWG 2 AWG: 600 Volt

ABOUT US ABOUT US 1 CRANE CABLES

CXP/CFP 100G MPO Cable Assembly

Optical Characteristics of a Reduced Bending-Loss Fiber with a Bending Radius of 5 mm

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Faster. Easier. Better.

Transcription:

GUMT Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)H Standard Rodent Protection 05-0-0 v3.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM GUMT0 GUMT04 GUMT06 GUMT08 GUMT GUMT6 GUMT4 -OM BI GUMT0 GUMT04 GUMT06 GUMT08 GUMT GUMT6 GUMT4 -OM3 BI GUMTD0 GUMTD04 GUMTD06 GUMTD08 GUMTD GUMTD6 GUMTD4 -OM4 BI GUMTE0 GUMTE04 GUMTE06 GUMTE08 GUMTE GUMTE6 GUMTE4 ITU G.657A BI GUMTA0 GUMTA04 GUMTA06 GUMTA08 GUMTA GUMTA6 GUMTA4 ITU G.657A BI GUMTF0 GUMTF04 GUMTF06 GUMTF08 GUMTF GUMTF6 GUMTF4 ITU G.657B3 BI GUMTI0 GUMTI04 GUMTI06 GUMTI08 GUMTI GUMTI6 GUMTI4 Std. plywood reel (non-returnable) Std. delivery length Ø560*336mm 4.5 kg 00 ± 05m Ø000*530mm 8 kg Applications Structured (premises) wiring systems: campus and/or building backbone (riser) and/or horizontal cabling. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Easy to install in ducts, tunnels and trenches. Not recommended for direct burial. Features & Benefits These cables are halogen-free (= FRNC and LSNH) and watertight and therefore suitable for internal and external use. Consequently splicing can be avoided and the installation gets more cost-effective. These cables are all dielectric (metal-free). Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794). Swellable reinforced yarns as common strength members and for the longitudinal watertightness.. Primary coated optical fibres: Ø 80 ± 5 um. 3. Tight buffered fibres: Ø 0.9 ± 0.05 mm. Colour coding of the buffered fibres: white red blue yellow green violet brown black orange turquoise pink grey The fibres 3 4 are ringmarked. 4. Swellable glassyarns for improved rodent protection. 5. Halogen-free (FRNC/LSNH) UV-resistant outer jacket. Identification: BELDEN OFC cable type number x type of fibre +date-, meter- and -marking. Mechanical Data No. of fibres 4 6 8 6 4 Ø nom. (mm) 5.4 5.4 5.9 5.9 7.6 8.6 9.6 Max. pulling tension (N) Short term 400 400 400 400 450 530 650 Energy of flame (kj/m) 9 96 347 37 6 845 08 Weight (kg/km) 5 6 30 3 45 53 65

Optical Characteristics Characteristics Single-Mode Matched-Cladded optical fibres according to ITU. Fibre-Type Mode-Field /Cladding Diameter (um) Attenuation B typical/ max. (db/km)) Dispersion (ps/(nm-km) PMD A (ps/km) Cable Cut-off A G.657A BI 8.9 ± 0.4 4.8 ± 0.3 30 0.34 / 0.35 0.9 / 0 / 4 3.5 8 0.06 60 F G.657A BI 8.9 ± 0.4 4.8 ± 0.3 30 0.34 / 0.35 0.9 / 0 / 4 3.5 8 0.06 60 I G.657B3 BI 8.8 ± 0.4 5 ± 0.4 30 0.34 / 0.35 0.9 / 0 / 3 3.5 8 0.06 60 Note A- Link design value Note B- Due to cabling the optical attenuation values can increase with max 0.5 db/km (30 nm), max. 0.09 db/km ( nm) and max. 7 db/km ( nm) Characteristics Multi-Mode Graded-Index optical fibres according to IEC 60793 Fibre- Type Core/ Cladding Diameter (um) Attenuation C typical/ max. (db/km)) Bandwidth (MHzkm) Ethernet Performance (m) GBE 0 GBE Num. Apert. (µm) 6.5/5 OM 6.5 ±.5 5 ±.7 / 3.0 0.7 / 0.8 00 600 0 33 75 ± 0.05 OM BI 50 ±.5 5 ±.3 /.5 / 0.6 600 600 83 0 ± 0.05 D OM3 BI 50 ±.5 5 ±.3 /.5 / 0.6 000 0 ± 0.05 E OM4 BI 50 ±.5 5 ±.3 /.5 / 0.6 3500 00 0 ± 0.05 Note C- Due to cabling the optical attenuation values can increase with max. 0.4 db/km 3

Macro Bending Performance Fibers Maximum attenuation increase for Bend Insensitive Single Mode fibers in db depending on turns and radius. Fibre-Type 00 5 mm 0 5 mm Turn 0 mm Turn 7.5 mm Turn 5 mm ) A G.657A 0.0 0.05 F G.657A 0.03 0. 0..0 I G.657B3 0.03 0.0 0.08 5 0.5 0.45 Maximum attenuation increase for Bend Insensitive Multi Mode fibers in db depending on turns and radius. Fibre-Type 6.5/5 OM 00 37.5 mm 5 mm ) 7.5 mm OM BI 0. 0.3 D OM3 BI 0. 0.3 E OM4 BI 0. 0.3 4

Mechanical, Physical and/or Environmental Characteristics Description: Tested according to: Requirement: According to Family specification: Storage Temperature Range IEC 60794---F -30 to +70 C IEC 60794--0 Installation Temperature Range -5 to +50 C Operating Temperature Range -30 to +70 C Strippability Secondary coating only 0 cm Secondary + primary coating 0 mm Bending radii for fibres and tight buffers Installation/operation For Bend Insensitive fibres >5 mm See Optical Characteristics Cable Water Blocking IEC 60794---F5 Pass Cable Min. Bend Operation (Long Term) IEC 60794---E 0 x Cable Diam. IEC 60794--0 Cable Min. Bend Installation (Short Term) IEC 60794---E6 0 x Cable Diam. Cable Max. Tensile Strength Operation (Short Term) IEC 60794---E See table with dimensions IEC 60794--0 Cable Max. Crush Resistance Operation (Long Term) Cable Max. Crush Resistance Installation (Short Term) IEC 60794---E3 3 kn/m 5 kn/m IEC 60794--0 Safety Testing standard Description / Value Reaction to fire IEC 6033-3-4 Smoke density IEC 6034- Halogen acid gas content IEC 60754- Zero Degree of acidity of gases IEC 60754- Min. 4.3 ph IEC 60754- Max. 0 µs/mm 5

Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. It is advisable to cap the cable-ends during storage. Options Indoor Mini-Breakout cables with tight buffered fibres or with excellent strippable dry semi-tight buffered fibres. Non-standard cable constructions with improved rodent protection, colours, details and/or additional information regarding specifications are available on request. 6