General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

Models UT350/UT320 Digital Indicating Controllers

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

MICRO-CONTROLLER X (48 48 mm)

DIGITAL PROGRAM CONTROLLER

SHIMADEN DIGITAL INDICATORS

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

SHIMADEN DIGITAL INDICATOR

DIGITAL INDICATING CONTROLLER

Model UT551 Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User s Manual for Single-loop Control

Model UT750 Digital Indicating Controller User s Manual for Cascade Control

High Performance Process & Temperature Controllers

Model UP350 Program Controller

General Specifications

SHIMADEN PROGRAM CONTROLLER

SHIMADEN DIGITAL INDICATORS

General Specifications

Excellent low-cost Process & Temperature Controllers

DC1010/DC1020/DC1030/DC1040

MICRO-CONTROLLER X (96 96 mm)

Analogue temperature controllers

General Specifications

Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control

General Specifications

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Temperature Controllers E5 J

Model UP550 Program Controller User s Manual for Loop Control with PV Switching

Model UP351 Program Controller

MICRO-CONTROLLER X (48 96 mm)

Ramp/Soak Temperature Controller REX-P250

CompoBus/D-type Digital Controller

Model UP750 Program Controller User s Manual for Dual-loop Control

PROCESS & TEMPERATURE CONTROLLERS

MODEL: TC10EM. Temperature Controller TC10 Series

Process Controller. PX series INSTRUCTION MANUAL. Thank you for the purchase of HANYOUNG product. Please read this manual carefully.

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

Model UP550 Program Controller User s Manual for Cascade Primary-loop Control

APPENDIX APPENDIX A 1

Digital indicator for panel mounting With multi-function input Model DI25

General Specifications

General Specifications

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

General Specifications


SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control

HYBRID RECORDER OUTLINE

General Specifications

K3P ENG.qxd 23/10/ Pagina 1

General. Specification FA-M3 F3CX04-0N. Temperature Monitoring Module GS 34M6H11-03E. General. Components and Functions. Model and Suffix Codes

Model Number Structure

Temperature Controllers

HA400 HA900 HA401 HA901

General Specifications

SHIMADEN DIGITAL CONTROLLER

PROGRAMMABLE CONTROLLER

PROGRAM CONTROLLER OUTLINE

PID CONTROLLERS LT SERIES

Digital Temperature Controller

Fuzzy Temperature Controllers E5AF

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

General Specifications

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

General Specifications

General Specifications

General Specifications

Process displays For standard signals, temperature, resistance measurement

General Specifications

VIEW RECORDERS SPECIFICATIONS

REX-F400 REX-F700 REX-F900

General Specifications

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

General Specifications

C C1 C2 AL1 AL2 AL3. Micro-controller X. Model: PXR SEL PXR-4. Operation Manual. ECNO:406a

K Series. Controllers / mini-programmers with wattmeter function and independent timer

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

ADAM 4000/4100 Series

Temperature Controls

Process and Temperature Controllers

Transcription:

General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available. Easy-to-read displays show input and the setpoint. T/C or RTD inputs are standard and the output type is selectable: ON/OFF, voltage pulse or DC current. The controllers operate in an Automatic mode only. Optional alarm contact outputs, retransmission output, contact input setpoint selection and RS8 communication are available. Each features dynamic self-tunig function for easy start up. Super Control fuzzy logic for overshoot suppression is a proven champion. MODEL AND SUFFIX CODES Model Suffix code Description UT... Temperature controller for standard type (or for heating) for cooling Option R... V... N... R... V... /AL /HBA /RS /V Relay output (time-proportional PID or on/off control) pulse output (time-proportional PID) No cooling output (standard type) Relay output (time-proportional PID or on/off control) pulse output (time-proportional PID) Alarm outputs ( points) (Note) Heater disconnection alarm (includes optional /AL function) (Note) (Note) Communication function (Note) (Note) V DC / V AC Note: /AL option cannot be specified when /HBA option is specified. /HBA option already includes the /AL option. Note: /HBA option cannot be specifed at the same time. Note: When specifying the /RS option, be sure to order the required number of copies of Communication Functions Instruction Manual separeately. You will not be supplied and instruction manual just because you order for the / RS option Model Suffix code Description UT... Temperature controller for standard type (or for heating) for cooling Option R... V... A... N... R... V... A... /AL /HBA /EX /RET /RS /V Relay output (time-proportional PID or on/ off control) pulse output (time-proportional PID) to ma output (continuous PID) (Note) No cooling output (standard type) Relay output (time-proportional PID or on/ off control) pulse output (time-proportional PID) to ma output (continuous PID) Alarm outputs ( points) (Note) Heater disconnection alarm (includes optional /AL function) (Note) (Note) (Note) SP/SP switching, starting of timer, and RUN/STOP switching by external contacts(note) PV retransmission output in to ma (Note) Communication function (Note) (Note) V DC / V AC Note: /HBA option cannot be specifed when to ma output (heating-side) is specifed. Note: /AL option cannot be specifed when /HBA option is specifed. /HBA option already includes the /AL option. Note: /HBA option and /RET option cannot be specifed at the same time. Note: /EX option and /RS option cannot be specifed at the same time.(model UT only) Note: /EX option includes contact input (for switching between the SP and SP target setpoints using external contacts) and contact input (for enabling the timer). Note6: When specifying the /RS option, be sure to order the required number of copies of Communication Functions Instruction Manual separeately. You will not be supplied and instruction manual just because you order for the / RS option. GS CE-E Copyright Dec. (MC) 7th Edition Mar. 6 (YK)

MEASURED VALUE INPUT The UT series allows you to freely change the input type by software. Table.UT Measured Input s Input Type Thermocouple RTD Unspecified ( C) Code OFF ( F) Code - to C - to F K to 6 C to F to C to 7 F - to C - to F J - to C - to F T - to C 6 - to 7 F 6 E - to C 7 - to F 7 L - to C - to F U - to C - to 7 F - to 8 C - to F Pt to C 6 to 7 F 6 - to C 7 - to F 7 -. to. C 8 - to F 8 JPt - to C Table.UT Measured Input s Thermocouple RTD DC voltage Input Type ( C) Code( C) OFF ( F) Code( F) Unspecified -7 to 7 C - to F K. to 6. C. to. F. to. C. to 7. F -. to. C -. to. F J -. to. C -. to F T -. to. C 6 -. to 7. F 6 E -. to. C 7 -. to 8. F 7 R to 7 C 8 to F 8 S to 7 C to F B to 8 C to F N - to C - to F L -. to. C - to 6 F U -. to. C - to 7 F Platinel to C to F -. to 8. C -. to. F Pt. to. C 6. to 7. F 6 -. to. C 7 - to F 7 -. to. C 8 -. to. F 8 JPt -. to. C to mv to V to V to V. to.. to.. to.. to. Note Note: Scalling is enable in the following range. - to, -. to., -. to., -. to. All Rights Reserved. Copyright, Yokogawa Electric Corporation GS CE-E Mar., 6-

HARDWARE SPECIFICATIONS Input: point Input type: Universal; can be selected by soft ware Input accuracy (at ± C ambient temperature) Thermocouple: ± C However, ± C for thermocouple input-7 to - C ± C for thermocouple input- to C ± C for type R and S (± C for to C) ± C for type B (accuracy is not guaranteed for to C) RTD: ± C ±digit (mv, V)±.% Sampling period for measured value input: ms Burn-out detection: Functions for thermocouple or RTD input (burn-out upscale only; can not be switched off) Input resistance: MΩ or greater for thermocouple or DC mv input Approx. MΩ for DC V input Maximum allowable signal source resistance: Ω for thermocouple or DC mv input kω for DC V input Effect of signal source s resistance:less than whichever is greater, ±. µv/ Ω or ±.% / Ω Maximum allowable wiring resistance for RTD input: Ω /wire (The resistance values of three wires must be the same.) Effect of wiring resistance: ±. C / Ω maximum Allowable input voltage: ± V DC for thermocouple or DC mv input ± V DC for DC V input Noise rejection ratio (/6Hz) Normal mode noise: Min. db Common mode noise: Min. db (Min. db for DC V input) Error of reference junction compensation: ±. C (at - C) ±. C (at - C) The reference junction compensation cannot be switched off. Applicable Standards: Thermocouple and resistance temperature detector JIS/IEC/DIN (ITS) Response time: second or less, 6% ( - %) (The time required for transmission output to reach 6% of the maximum excursion when PV abruptly changes from % to %) : point (for standard type ) or points (for heating/cooling type) type: Choose one from () to () below: () Relay contact output Contact capacity: A at V AC or A at V DC (with resistance load) Note : The control output realy cannot be replaced by users () pulse output load resistance: On voltage: to 8 V DC 6 Ω or greater short-circuit current: Off voltage:. V DC or less approx. ma () Current output signal: to ma Maximum load resistance: 6 Ω accuracy: ±.% of span (at ± C ambient temperature) Display Measured value and setpoint display: [UT] -digit, 7-segment LED display [UT] -digit, 7-segment LED display Switchs between SP and PV display. Character height: See the table below. UT UT PV display (mm) 7.. SP display (mm) N/A. Status indicator lamps: LEDs Retransmission The retransmission output is provided only when the /RET option is specified, but is not available for the UT or a heating/cooling type. signal: PV(measured value) in to ma DC Maximum load resistance: 6 Ω accuracy: ±.% of span (at ± C ambient temperature) Contact Inputs The contact inputs are provided only when the /EX option is specified, but are not available for the UT. Functions: () Switching over two setpoints (SP and SP) () Starting a timer(see the following Alarm Functions. ) () RUN/STOP switching Specify two functions from the three functions using parameter DIS. All Rights Reserved. Copyright, Yokogawa Electric Corporation Input: points (with the shared common terminal) Input type: Non-voltage contact or transistor contact input Contact capacity: At least V, ma On/off judgment: On state for kω or less; Off state for kω or greater Alarm Functions Alarm Functions (Option Code /AL or /HBA) Alarm types: types (Waiting action can be set by software): PVhigh limit, PV low limit, Deviation high limit, Deviation low limit, De-energized on deviation high limit, De-energized on deviation low limit, Deviation high and low limits, High and low limits within deviation, De-energized on PV high limit, De-energized on PV low limit, self-diagnostic alarm, FAIL output Alarm output: relay contacts Relay contact capacity: A at V AC or A at V DC (with resistance load) Heater Disconnection Alarm Function (Option Code /HBA) The heater disconnection alarm is available when timeproportional PID control or on/off control is selected. Heater current setting range: to 8 A Alarm output: relay contact (The terminals are the same as those of the /AL option.) On time of burn-out detection: Min.. second Sensor: L-6-S-H or L--S6-8 (URD Co. Ltd.) To be purchased separately. Timer Function (Option Code /EX/AL or /EX/HBA) The output contact status changes when the preset time has passed since TMR contact turned on. The contact action can be selected by software from: () Make contact - the contact closes upon time-up. () Break - the contact opens upon time-up. Input contact type: See Contact Inputs above. Communication Function The communication function is provided only when the /RS option is specified. Communication Protocol Personal computer link: Used for communication with a personal computer, or UT link module of the FA-M controller (from Yokogawa Electric Corporation). Ladder communication: Used for communication with a ladder communication module of the FA-M, or a programmable controller of other manufacturers. MODBUS communication: Used for communication with equipment featuring the MODBUS protocol. Communication Interface Applicable standards: Complies with EIA RS-8 Number of controllers that can be connected: Up to Maximum communication distance:, m Communication method: Two-wire half-duplex, startstop synchronigation, non-procedural Baud rate:, 8, or 6 bps Safety and EMC Standards Safety: Compliant with IEC/EN 6- (CE), IEC/EN 6-- (CE), IEC/EN 6-- (CE), approved by CAN/CSA C. No. 6- (CSA), approved by UL 6-. Installation category: II, Pollution degree: Measurement category: I (CAT I) (UL, CSA) O (Other) (CE) Rated measurement input voltage: Max. V DC Rated transient overvoltage: V (*) * This is a reference safety standard value for measurement category I of CSA/UL 6-, and for measurement category O of IEC/EN 6--. This value is not necessarily a guarantee of instrument performance. EMC standards: Complies with EN 66, EN 6--, EN 6-- and EN (CE). Class A Group. All wires except those for the power supply and relay contact output terminals are shielded. During test, the controller continues to operate with the measurement accuracy within ±% of the range. KC marking: Electromagnetic wave interference prevention standard, electromagnetic wave protection standard compliance Construction, Mounting, and Wiring Construction: Dust-proof and Drip-proof front panel conforming to IP6. For side-by-side close installation, the controller loses its drip-proof protection. Casing: ABS resin and polycarbonate Case color: Black Mounting: Flush panel mounting Terminals: Screw terminals External dimensions: Refer to P.. Weight: UT/UT:Approx.g and Isolation (Common for All Models) Power supply Frequency Maximum power consumption Memory Withstanding voltage Insulation resistance Between primary terminals and secondary terminals (See Notes and.) Between primary terminals and secondary terminals (See Notes and.) Rated at - V AC V AC/DC when /V is specified or 6 Hz 8 VA maximum(w maximum) when /V is specified : W maximum Non-volatile memory CE: V AC for minute (Between relay terminals and secondary terminals V AC for minute) UL/CSA: V AC for minute (Note ) M Ω or more at V DC Note : The primary terminals are the power supply terminals and relay output terminals. The secondary terminals are the analog input and output terminals, the voltage pulse output terminals, and the contact input terminals. Note : The withstanding voltage is specified as V AC per minute to provide a margin of safety. Note : V power supply is the secondary terminal. Isolation The bold lines below indicate reinforced insulation, and the broken line indicates functional insulation. In case of CE conformity, alternate long and short dash line indicates basic insulation. Power supply terminals (- V AC) terminals: relay contacts Alarm output terminals ( relay contacts) V DC/ V AC Measured value input terminals input terminals for /HBA input terminals for /EX (Note ) Internal circuit (Note ) terminals: - ma DC output or voltage pulse (Note ) Retransmission output terminals: - ma (Note ) RS-8 terminals for /RS Note : The /EX option is not available for the UT. Note : Neither the measured value input terminals, input terminals for the /HBA option, nor input terminals for the /EX option are isolated from the internal circuit. Note : The UT does not have the to ma DC output. Note : The /RET option is not available for the UT. Environmental Conditions Normal Operating Conditions Warm-up time: At least minutes Ambient temperature: to C ( to C when mounted side-by-side) Rate of change of temperature: C/h or less Ambient humidity: to % RH (no condensation allowed) Magnetic field: A/m or less Continuous vibrations of to Hz: Amplitude of. mm or less Continuous vibrations of to Hz:. m/s (.G) or less Short-period vibrations:.7 m/s (.G) for seconds or less Shock: 8 m/s (G) for milliseconds or less Mounting angle: Upward incline of up to degrees; downward incline is not allowed. Altitude: m or less above sea level Maximum Effects from Operating Conditions () Temperature effects Thermocouple, DC mv and DC V input: ± µv/ C or ±.% of F.S. / C, whichever is the larger Resistance temperature detector: ±. C/ C or less Analog output: ±.% of F.S./ C () Effect from fluctuation of power supply voltage (within rated voltage range) Analog input: ±. µv/v or ±.% of F.S./V, whichever is the larger Analog output: ±.% of F.S./V Transportation and Storage Conditions Temperature: - to 7 C Humidity: to % RH (no condensation allowed) Shock: Package drop height cm (when packed in the dedicated package) GS CE-E Mar., 6-

FUNION BLOCK DIAGRAM In this block diagram of a UT series controller, the shaded Measured Value Input area functions are featured in all the UT series controllers Input Processing including the UT; the white area functions are featured in Bias Calculation the UT controller only. SP SP When ordering, please specify the model, suffix, and option First Order Lag codes according to the functions required. Super Calculation UT:digits, UT :digits PV Indication External Contact Inputs (/EX) DI SP/SP Timer function RUN/STOP Rate-of-change Limiter DI UT:digits, UT :digits SP Indication (/HBA) Specify using parameters Heater Disconnection Alarm PID Control Calculation Self-tuning Calculation Retransmission Scaling Alarm s (/AL or /HBA) Retransmission Relay Pulse - ma (/RET) (Heating-side for Heating/Cooling Control) Relay Pulse - ma Cooling-side for Heating/Cooling Control AL AL F.ai EXTERNAL DIMENSIONS UT Max..8 Max. 6 Max..8 Max. 7.8 8 8 Panel thickness to Mounting Bracket Terminal Cover F.ai UT Max..8 (.76) Max. 7.8 (.88) 8 Max. 6 8 Max..8 Panel thickness to Mounting Bracket Terminal Cover Normal Allowable Deviation= ±(Value of JIS B - tolerance grade IT8) / F.ai All Rights Reserved. Copyright, Yokogawa Electric Corporation GS CE-E Mar., 6-

PANEL CUTOUT DIMENSIONS General Mounting Min. 7 +.6 +.6 Min. 7 () +.6 Side-by-side Close Mounting () {(N-) 8+} +.6 N is the number of controllers. If N, then measure the actual length. F6.ai TERMINAL ARRANGEMENTS UT Terminal Arrangement Cooling-side (for heating/cooling type only) (Note ) Alarm s ALM ALM When "/AL" or "/HBA" is specified Universal input-selectable input type TC Input 7 + RTD Input 6 B 7 b 8 A Relay Contact Pulse 6 NO + -- 7 8 L N -V AC + V AC/DC -- When "/V" is specified Control-side (heating-side output for heating/cooling type) RS-8 Relay Contact Pulse RSB(+) RSA(-) (Note ), (Note ) SG (Note ) NO + -- When /RS is specified Note : The heater current detection input terminals (option code:/hba)are defined as terminals and for a standard type and as terminals and for a heating/cooling type. Note :For a heating/cooling model, you are not allowed to specify both the/hba and/rs options at the same time. UT Terminal Arrangement Retransmission + -- (Note ) When "/RET" is specified (Note ) Cooling-side (for heating/cooling type only) Relay Contact Pulse to ma DC NO + + -- -- (Note ) RS-8 RSB(+) RSA(-) SG When "/RS" is specified External Contact Inputs TMR STOP SP STOP When "/EX" is specified TMR STOP SP STOP Alarm outputs ALM ALM When /AL or "/HBA" is specified 6 7 8 Timer starts when DI=ON Timer stops when DI=OFF SP/SP SP when DI=ON Parameter DIS Timer starts RUN/STOP when DI=ON Timer stops STOP when when DI=OFF DI=ON RUN/STOP SP/SP STOP when SP when DI=ON DI=ON Universal input-selectable input type TC Input RTD Input DC mv or V Input 6 B 7 + 7 + 7 b 8 A (heating-side output for heating/cooling type) Relay Contact Pulse to ma DC NO + + + V AC/DC -- -- Note :The heater current detection input terminals(option code:/hba)are defined as terminals and for a standard model, and as terminals and for a heating/cooling model. When the / RET option is specified, these terminals are defined as terminals and. L N -V AC When "/V" is specified -- F7.ai All Rights Reserved. Copyright, Yokogawa Electric Corporation GS CE-E Mar., 6-