EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

Similar documents
COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. Transmitter for ph-value

Level Sensors Reed Contact Chain

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

Dissolved Oxygen Measurement liquisys M COM 223 F / 253 F

Electromagnetic flowmeter in all metal design Model MIM

Magnetic Inductive Flowmeter

Temperature Transmitters

ph/orp Measurement OPM223/253

Full Metal Variable Area Flowmeter and Counter Model BGF

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

Conductivity measurement SmarTec S CLD 132

Liquid Level Switches

Electronic Flow Monitor

Coriolis Massflowmeter

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

Signet 9950 Dual Channel Transmitter

ph / ORP Measurement mypro CPM 431

Chlorine / Chlorine Dioxide Measurement liquisys M CCM 223 / 253

Coriolis Mass Flow Meter Model TM

Process displays For standard signals, temperature, resistance measurement

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

ph or ORP Transmitter

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

Signet 9950 Dual Channel Transmitter

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

dtrans Az 01 µp Indicator/Controller for analytical measurement

NGR. Guided Wave Radar Level Transmitter

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Signet 9900 Transmitter

The transducer component converts the measured signal and displays the actual value.

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Technical Information Liquisys M CCM223/253

Insertion Thermocouples with Bayonet Lock

ABB ph/orp analyzer and probe package

DIGEM f 96 x 48 EK. Applications. Description

Digital indicator for panel mounting With multi-function input Model DI25

Ultrasonic level transmitter, non-contact

Liquisys M CCM223/253

Drinking water monitoring

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

ph/orp Transmitter SIGNET

dtrans Lf 01 µp transmitter / controller for electrolytic conductivity

Liquid level monitoring relay CM-ENS.2x

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

For reliable and continuous measurement of water quality insist on Aqua SMARTPro Transmitters

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

PEM353. Universal measuring device

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

OPTISENS ORP 8590 Technical Datasheet

Digital inductive conductivity transmitter

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Analogue temperature controllers

dtrans ph 01 µp transmitter / controller for ph value or redox voltage

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

High-precision process calibrator Model CED7000

LST400 Ultrasonic level / open channel flow transmitter

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Conductivity Analyzer

Signet 9900 Transmitter

XUA1 - AC Voltage and phase balance relay

1000TR. Instructions

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

Coupling Relays and Converters

dtrans ph 01 µp Transmitter / Controller for ph or redox potential (ORP)

B850 Boiler House Energy Monitor

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

P5201 Universal Programmable Transmitters with Galvanic Isolation

Signet ph/orp Transmitter * *

DUK. Compact Ultrasonic Flowmeter

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

+GF+ SIGNET Temperature Transmitter Instructions

Level Limit Switch nivotester FTL 325 P

Electromagnetic Flow Transmitter

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

s Climatix extension module 26 I/Os POL985.00/XXX

Digital conductivity transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Electromagnetic flowmeters and switches DWM 1000/2000

XF2 Frequency Relay. Manual XF2 (Revision A)

Analog outputs (option) Outputs 1 + 2: 0(4) - 20 ma or 0-10 V

8900 Multi-Parameter Controller

Transcription:

KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue output Alarm relay Two additional relays (for use as control contacts) Simple operation with: Clear menu structured programming Two-point calibration with CAL key Manual control of contacts Large text display allowing: User guidance notes Error indication Easy programming Safe operation because of: Overvoltage protection (lightning protection) Plausibility calibration check and sensor monitoring Custom alarm configuration for alarm contact and residual current KOBOLD offices exist in the following countries: ARGENTINA, AUSTRIA, BELGIUM, BRAZIL, CANADA, CHINA, FRANCE, GERMANY, GREAT BRITAIN, ITALY, NETHERLANDS, POLAND, PERU, SWITZERLAND, USA, VENEZUELA KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. (06192) 299-0 Fax (06192) 23398 E-mail: info.de@kobold.com Internet: www.kobold.com Model: APM-X 9

Description The transmitter APM-X in a field or panel housing offers a conpetative solution for all applications in the area of water and waste-water treatment as well as in industrial process applications. The parameters to be measured (ph or ORP) are selected in the menu. The associated measured value can be displayed in the other measuring mode during measurement (for example ph can be switched to mv and mv/orp can be switched to ORP %). The temperature is shown simultaneously and can be toggled between C and F or removed as required. Typically ph electrodes are always calibrated with the same ph values. The transmitter therefore provides the settings from the last calibration as a pre-selection for the next one. Should the buffer solutions be swapped by mistake during calibration, the plausibility check ensures that the calibration is accepted. Due to the large display the user guidance is simple and elegant. The correctness of the measurement result is of the highest priority. Different alarms are needed depending on the application. Therefore, the transmitter allows the configuration of the alarm contact, and the residual current, independently of one another and isolated for every possible fault. Unnecessary or undesired alarms can thus be removed. The two additional contacts can be used as limit contacts (and for temperature as well), as P(ID) controller and for electrode cleaning functions. LCD display for the measured values, configuration data and actual value Push button for switch over of the relays during hand operation A full view The actual value and temperature are shown simultaneously on the display. This gives you a full view of the most important process data. Text information in the configuration menu helps to adjust the device parameters. Intelligent and simple All operating functions for the device are arranged in a clear menu structure. Individual parameters can be selected easily and changed after entering a code. Electrical connection All connections to the panel-mounted instrument are made with terminal blocks at the back. The entire wiring (including measuring cell cable) for field instruments is connected to terminals in the transmitter connection chamber. A complete measuring device comprises: the ph/orp transmitter model APM-X a ph combined electrode model APS-X1Q, APS-X2Q or APS-X5K or a ORP combined electrode model ARS-X1Q or ARS-X5K a suitable ph/orp measuring cable model APK-X as well as one of the following: a separate temperature sensor Pt100 model AZT-X transmitter wall (AZM-Z1) or pipe mounting (AZM-Z2) accessory. flow or immersion assembly for installation and protection of the electrodes (see Accessories) 4 main buttons for calibration and parametrisation Switch over between automatic and hand operation of the relays LED indication for alarm functions LED indication for the position of the alarm outputs 10 www.kobold.com

Application examples for ORP-measurement Drinking water: Chlorine batching Industrial waste-water treatment: Chromate reduction with iron(ii) or bisulphite Cyanide oxidation with Hypochlorite Nitrite oxidation with Hypochlorite Communal waste-water treatment: Controlling denitrification Swimming pools: Regulating Chlorine dosing Monitoring the water quality according to DIN 19 643 Application examples for ph measurements: Drinking water: Monitoring parameters according to the ordinance on drinking water Industrial waste-water treatment: Neutralization Detoxication Precipitation station Final inspection Communal waste-water treatment plants: Inflow/sand-trap Activation tanks (for nitrification) Run-off Digestion tower Production facilities of the following sectors: Chemical pulp/paper Paints Textiles Pharmaceuticals Chemical industry Food industry Technical Datas Inputs Measured quantities: ph, ORP, temperature ph-measurement Measuring range: ph 0-14 Indicating range: -2 - +16 ph with indication of measuring range overflow and underflow ph-offset-range: ±2 ph Adaptation of rate of rise: glass: 38.0-65.0 mv/ph (nominal 59.16 mv/ph) antimony: 25.0-65.0 mv/ph (nominal 59.16 mv/ph) Zero-point: glass: 5.0-9.0 ph (nominal 7.0 ph) antimony: -1.0-3.0 ph (nominal 1.0 ph) Max. cable length ph electrode: recommended: 50 m ph-signal input Input resistance under nominal reference conditions: >1 x 10 12 Ω www.kobold.com 11

ORP measurement Indication and measuring range: ORP-offset range: -1500 - +1500 mv / 0-100% ±200 mv / ±10% ORP signal input Input resistance under nominal reference conditions: > 1 x 10 12 Ω Temperature measurement Temperature sensor: Measuring range: Temperature offset range: Pt 100-20 - +150 C ±20 C Digital inputs 1 and 2 Voltage: Current consumption: 10-50 V max 10 ma Outputs ph-signal output Current range: Residual current: Load: Output range: Isolation voltage: Overvoltage protection (lightning protection): ORP-signal output Current range: Load: Transmission range: Isolation voltage: Overvoltage protection (lightning protection): Temperature signal output (optional) Current range: Load: Transmission range: Isolation voltage: Overvoltage protection (lightning protection): Auxiliary voltage output Output voltage: Output current: 0 / 4-20 ma, electrically isolated 2.4 / 22 ma max. 500 Ω adjustable, min. 1 ph max. 350 V eff / 500 V DC acc. EN 61000-4-5:1995 0 / 4-20 ma, electrically isolated max. 500 Ω absolute: adjustable,, min. 50 mv relative: fixed, 0-100% max. 350 V eff / 500 V DC acc. EN 61000-4-5:1995 0 / 4-20 ma, electrically isolated max. 500 Ω adjustable, 10-100% of full-scale value max. 350 V eff / 500 V DC acc. EN 61000-4-5:1995 15 V ± 0.6 V max. 30 ma Contact outputs (floating changeover contacts) Current max. switched under resistive load (cos ϕ= 1): Current max. switched under inductive load (cos ϕ = 0.4): Switching voltage: Breaking capacity under resistive load (cos ϕ = 1): Breaking capacity under inductive load (cos ϕ = 0.4): max. 2 A max. 2 A max. 250 V AC, 30 V DC max. 1250 VA AC, 150 W DC max. 500 VA AC, 90 W DC 12 www.kobold.com

Limit contact Pickup/ dropout delay: Controller Function (adjustable): Control response: Proportional band: Pulse length range: Pulse frequency range: Alarm Function (switchable): Alarm setting range: Alarm delay: 0-2000 s pulse length/ pulse frequency control PID (programmable) Kp: 0.10-10.00 0.5-999.9 s 60-180 pulses/min contact: steady/momentary-break/make ph / temperature: entire measuring range 0-2000 s Measurement accuracy ph-measurement Reference temperature: Resolution: Operating errors 1) display: Repeatability Operating errors 1) output signal: ORP-measurement Resolution Operating errors 1) display: Repeatability 1): Operating errors 1) output signal: Temperature measurement Measured-value resolution: Operating errors 1) display: Operating errors 1) output signal: +25 C 0.01 ph max. 0.5 % of measuring range max. 0.2 % of measuring range max. 0.75 % of measuring range 1 mv / 0.1 % max. 0.5 % of measuring range max. 0.2 % of measuring range max. 0.75 % of measuring range 0.1 C max. 1.0 % of measuring range max. 1.25 % of current output Environmental conditions Ambient temperature: Ambient temperature: Storage and transport temperature: Relative humidity: Protection for panel-mounted device: Protection for field housing: Electromagnetic compatibility: - 10 - +55 C (under nominal reference conditions) -20 - +60 C (for limit conditions of operation) -25 -+65 C 10-95 %, non-condensing (nominal reference conditions) IP 54 (front), IP 30 (rear) IP 65 emitted interference according to EN 50081-1:1992 Noise immunity according to EN 50082-2:1995 1) according to IEC 746-1, under nominal reference conditions www.kobold.com 13

Mechanical Design Dimensions of panel-mounted unit (H x Wx L): Mounting depth: Dimensions of field housing (H x Wx L): Weight of panel-mounted unit: Weight with field housing: Readout display: Materials Housing panel-mounted unit: Front membrane: Field housing: Power requirement Supply voltage: Power consumption: Fuse: Dimensions Field housing 96 x 96 x 145 mm approximately 175 mm 117 x 117 x 222 mm max. 0.7 kg max. 2.4 kg (with support or mounting bracket) Liquid Cristal, 5+9 -digit alphanumeric and status polycarbonate polyester, fine matt aluminium, powder coated 100 / 115 / 230 V AC +10%-15%, 48-62 Hz 24 V AC/DC +20%-15% max. 7.5 VA miniature, medium-time lag 250 V / 1 A Panel-mounted housing 117 221,8 Flat gasket (included in delivery) M a Mounting cutout according to DIN 43700 92 +0,5 33 117 57 90 96 92 +0,5 32,5 42,5 64 ca.25 max. 45 139 6 Type codes APM-X A Analytical technology P ph-value Mounting brackets on page 64 M Transmitter X Device version 2 2 contacts (as limit value contacts or P(ID) controller or timer) E F W S R Housing for panel mounting Field housing Field housing with wass mounting bracket (fix) Field housing with wall mounting bracket (360 rotation) Field housing with pipe mounting bracket 1 2 3 4 24 VAC/DC 230 VAC 115 VAC 100 VAC S T Analogue output ph or ORP Analogue output ph or ORP and temperature 0 No additional interface A P M X 2 0 14 www.kobold.com