TECHNICAL INFORMATION TRANSOZINC EPOXY PRIMER Primario Epóxico Orgánico de Zinc COMPONENT

Similar documents
TECHNICAL INFORMATION CLEAR CONCENTRATED INDUSTRIAL VARNISH BARNIZ INDUSTRIAL CONCENTRADO TRANSPARENTE

WEGPOXI WET SURFACE 89 PW ALUMINUM

PRODUCT GUIDE: CATALYZED TOPCOATS. Version:

WEGTHANE HPA 501 (HPA 501/ HPA 502/ HPA 503/ HPA 504)

Semimatte Volume Solids 55 ± 2% (ISO ) VOC. Overcoating Data 10ºC 25ºC 35ºC Min. 4 hours 2 hours 1 hour Max. 7 2 hours 48 hours 36 hours

PRODUCT GUIDE: CATALYZED PRIMERS. Version:

Gloss Volume Solids 88 ± 2% (ISO ) VOC. Overcoating Data 10ºC 25ºC 35ºC Min. 24 hours 12 hours 8 hours Max. 72 hours 24 hours 24 hours

Specification Guide. Portable & Modular Buildings

Knowledge Requirements. Protective Coatings Applicator Abrasive Blast Cleaning Operator Spray Painting Operator. trainthepainter.

SUNBELT transformer WIDTFA3501 PAINTING TRANSFORMERS WITH WATERBORNE PAINT SYSTEMS INTERNAL USE ONLY DOCUMENT HISTORY

PRODUCT GUIDE: WATERBORNE TOPCOATS. Version:

PRODUCT GUIDE: COMPLIANT TOPCOATS. Version:

AquaCLAD Water-Reducible Rust Preventative Alkyd

10P20-44MNF High Solids Epoxy Primer

CUPRON NEXT TECHNICAL DATA SHEET

Physical constants Finish: ASTM D Flash point: Rangan Far, s Adding thinner to a paint may change the flash point of the diluted material.

HP Chromate Free Epoxy Primer P /-4505/-4510

HP Epoxy Primer P

Use suitable respiratory protection Akzo Nobel Sign Refinishes recommends the use of a fresh air supply respirator.


Technical Data Sheet ACRYLIC FILLER 4:1 Acrylic filler with anti-corrosion additives RELATED PRODUCTS. Acrylic and polyurethane thinner

1. Labels: Do not paint over UL, FMG, or other code-required labels or equipment name, identification, performance rating, or nomenclature plates.

Product Data Sheet November 2016

Quality Marine Equipment Since Antifouling Paint For Metal Under The Waterline SPRAY. Application Instructions.

These Application Instructions cover surface preparation, application equipment and application details for HEMPADUR MASTIC 45880/45881.

Full Product Name. Products. Properties. 2K Etch Primer. Type of Product Description

Aerodur 3001 Base Coat Special Effects

A Guide to the Application and Use of Organic and Inorganic Paints and Surface Coatings

Specification Guide. Conveyors

Data Sheet 5741 Englisch

CITY OF TOMBALL. Section FIRE HYDRANTS 1.01 SECTION INCLUDES. A. Fire hydrants. B. Adjustment of fire hydrants and gate valves.

APPLICATION NOTE - SR001. Cold Weather Application

WATER-BORNE SOL-GEL BASED BINDERS FOR THE FORMULATION OF AMBIENT CURING ZINC DUST PAINTS

APPLICATION NOTE - SR001. Cold Weather Application

South African Qualification and Certification Committee (Corrosion Protection) SYLLABUS MODULE PS PAINTING SUPERVISORS COURSE

Metal 3in1. Applied directly to rust A smooth gloss anti-rust enamel paint for metal surfaces

Product Data Sheet August 2006 (Updated in December 2014)

A-LF-Sea. Application Manual for M&R. (Full blasting)

Painting Procedure Aeroglaze Z306 Flat Black Absorptive Polyurethane

E380 and E381 Epoxy Primer

Big Sky Product Information Sheet. Epoxy Prime Primer/Sealer PS3042 (Lt. Gray) PS3044 (Dk. Gray) PS3045 (Black) PS3047 (Yellow Oxide)

A. Section includes surface preparation and the application of paint systems on exterior substrates.

Marine. Paint Specification: November ::Fiberglass Substrate:: PAINT that OUTLASTS & OUTPERFORMS

Technical Data Sheet Primers/Surfacers LV 350 Primer EP FOR PROFESSIONAL USE ONLY

Painting Safety Procedure

SELECTION AND PREPARATION OF SUBSTRATES

RAPTOR EPOXY PRIMER RAPTOR 4:1 ANTI-CORROSIVE EPOXY PRIMER DESCRIPTION

BRUSH APPLICATION INSTRUCTIONS

January 2007 Product Information DELTRON D821

Volume Solids % Weight Solids %

TECHNICAL DATA SHEET IVY COATINGS:

Technical Data Sheet Primers/Surfacers LV 250 Primer EP /005 FOR PROFESSIONAL USE ONLY

PercoTop PUR 2K MS Topcoat

Primer Surfacer EP II

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

PercoTop 449 2K Structure Topcoat

Specification Guide. Construction Equipment

DULUX UNIVERSAL UNDERCOAT

VELOX PLUS APPLICATION INSTRUCTIONS QUALITY MARINE EQUIPMENT SINCE 1981

Quality Marine Equipment Since Antifouling Paint For Metal Under The Waterline ROLLER. Application Instructions.

EXTERIOR PAINTING

Getting the Most Out of Airless Spray

Paints for sheet-iron roofs. For corrosion protection of metal surfaces outdoors

High-quality, water-dilutable satin gloss enamel on the basis of a modified alkyd technology.

The Application Guide offers product details and recommended practices for the use of the product.

Epoxy Coal Tar. Protects Steel and Concrete in Marine and Industrial Environments.

Sketchpaint. Ideal for turning any smooth surface into a whiteboard. Ready to use in 5 days

Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

mm bar at the air inlet minutes at 20 C 5-10 minutes at 20 C. 8 hours at 20 C 45 minutes at 60 C 3 coat application

Industrial paints for metal surfaces. Product catalogue

Union County Vocational - Technical Schools Scotch Plains, New Jersey

The Application Guide offers product details and recommended practices for the use of the product.

Application of Air & Water Barrier Using Sprayers and Power Rollers TDS 410M

Data Sheet K-Aqua Silk Matt Enamel K-Aqua Seidenmattlack K-Aqua Hardener Properties. Material description.

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel and iron.

The Application Guide offers product details and recommended practices for the use of the product.

MATERIAL AND EQUIPMENT STANDARD FOR VINYL PAINT (ALUMINUM) AS INTERMEDIATE AND TOP COAT (FINISH) ORIGINAL EDITION MAY 1993

INDUSTRIAL & OEM PRIMER AND TOPCOAT PRODUCT INFORMATION

06/09/54. Theory of Rust

Desobond CA102 Adhesive Bonding Primer

APPLICATION HANDBOOK for BUILDING COATINGS for Thermal Insulation, Mold Resistance, UV Resistance, Lead Abatement

SECTION 025 INDUSTRIAL PAINTING

STANDARD SPECIFICATION FOR SHOP AND FIELD PAINTING

Magnetpaint & Sketchpaint

PRODUCT DESCRIPTION High quality interior or exterior enamel for surfaces where a glossy durable finish is required

Impredur Silk Matt Enamel 880

SECTION EXTERIOR PAINTING PART 1 - GENERAL

orthwest Corrosion Engineering

PRODUCT GUIDE FIRST FOR LASTING IMPRESSIONS

.3 Comply with the requirements of the Manitoba Occupational Health and Safety Act and Regulations for Construction Projects.

UHS Duralit Extra Tinters series 150

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

The Application Guide offers product details and recommended practices for the use of the product.

Ontario ENGINEERING STANDARD SPECIFICATION 1/14 REV. CIVIL MATERIAL PROTECTION PAINTS GENERAL REQUIREMENTS. Approved by.

SEA45 Water Borne Acrylic Gloss

BEST PRACTICES REPORT. Parks & Recreation Dept. City of Sioux Falls, SD PROJECT OVERVIEW: Industrial Customer: City of Sioux Falls Parks & Recreation

IRON MIOX Micaceous iron polish, anticorrosive for iron surfaces with no patchy finish

Surface Finishes. For woods metals and plastics

APPLICATION HANDBOOK for INDUSTRIAL COATINGS

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel.

Transcription:

COMPONENT Component A Component B 513-80859-999 DESCRIPTION Zinc organic primer with galvanising USE Transozinc Epoxy Primer can be used as a high performance anticorrosive base coat on steel surfaces, as structures, machinery and tank walls. It's recommended for severe industrial environments and over permanently immersed surfaces. It can be covered with any finish. Structure Exterior/Interior Surface Product line Buried Pipes, Buried Structures, Exterior pipes, exterior tank walls, Interior Pipe Walls, Metallic Structures, Structural elements (column, trusses, etc.), Wastewater tanks Indoor, Outdoor, Roofed Exterior walls Steel Professional/industrial Line CHARACTERISTICS ASSESSMENT Finish Primer Excellent cathodic protection Matte PHYSICAL PROPERTY DATA

Volume Solids (%) 57 to 59% Weight per Gallon (kg/gl) 11,8 Weigth Solids of the mix (%) 86 to 88% Theoretical Yield (m²/gallon) 103 m² a 1 mil VOC (grams/liter) 365 Maximum Service Temperature ( C) 120 Pot life 12 h to 20 C Useful life in stock Comp. A: 12 months Comp. B: 12 months Recommended Dry Film Thickness 3 mils Definition of theoretical yield: Maximum surface that can be covered with a painting under ideal conditions. The practical performance varies depending on the type of surface used tool, applicator experience and other factors. 1 mil = 0.0254 mm. PRESENTATION AVAILABLE PRESENTATIONS, Metal container of 3,785 Liters = 1 Gallon AVAILABLE COLORS Gris 513-80859-999, Metallic Container of 0.946 Liters = 1/4 Gallon SURFACE PREPARATION CONDITION New steel Surfaces INSTRUCTION New steel or iron surfaces should be cleaned with Desoxidante- Desengrasante Sur # 305-900.

Mechanical cleaning Abrasive blast Cleaning Use hand or power tools to clean surface up to a SSPC (Standard Steel Structures Painting Council) SP2 or SP3 Cleaning Standard. Clean with abrasive blast to get a SSPC (Standard Steel Structures Painting Council) SP5 o SP10 cleaning standard. PRODUCT PREPARATION COMPONENT MIXING RATIO MIXING INSTRUCTIONS Component A: - Component B: 513-80859-999 - COMPONENTE B 4 partes Mix Component A and B as indicated, wait for the induction time and finally add the diluent.: 1 parte INDUCTION TIME : 20 minutes PRODUCT APPLICATION IT CAN BE APPLIED WITH Airless spray Brush Spray gun (gravity or suction feed)

Airless spray application Nozzle size. 0,43-0,50 mm Fan Angle 60-80 Dry Coat Thickness Wet Film Thickness Line Pressure 3 mil 5,2 mil 180 BAR These are references values. It may be necessary to vary output pressure or nozzle size to get better results. Application conditions Surface Temperature 5 C - 35 C Room Temperature 10 C - 40 C Relative Humidity 10% - 85% Surface temperature should be at least 3 C (5 F) over dew point. Number of layers and thickness Apply the following layers of the intended paint system within the recommended repainting times. Drying times Dry-to-Touch Time Recoat time Curing Time (days) 1,5 h 4 h - 24 h 7 d Dry times are based in normal application, temperature, film thickness and dilution conditions and are provided to serve as a guide. If necessary to apply a second coat, or the next layer of the paint system, observe the recommended drying times.

OBSERVATIONS If you need more information, one of our technicians will assist you. Call 800-SUR-2000 or email us at customerservice@gruposur.com Keep container tightly closed in a ventilated place, between 20 and 30 C, out of reach of children. Container must be kept tightly closed to avoid loss of its properties. HEALTH The user of this product may need the appropriate Personal Protection Equipment (PPE), as described in its Safety data Sheet (MSDS), available at http://www.gruposur.com If you need to dispose of empty containers of our products in Costa Rica, contact your SUR Color paint store or our industrial compound in La Uruca, San Jose.