TYPE OF PIPING PRESSURE TESTING. For large diameter piping hand wipe/ sweep should be applied as much as possible (inspection to be recorded).

Similar documents
CORPORATE QUALITY SYSTEM PROCEDURE

Inspection and Test Plan for Water Tube Boiler

INSPECTION AND TEST PLAN

This specification describes the minimum requirements for piping systems for the following service:

MEC-QW-E-2002 Senior QA/QC Welding Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

This specification describes the minimum requirements for piping systems for the following service:

Annexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)

NCCER Progress Blvd, Alachua, Florida Phone: (888)

Introduction to Piping Material Activities

Heat Exchanger Construction Checklist

National Craft Assessment and Certification Program S P E C I F I C A T I O N S. INDUSTRIAL BOILERMAKER - MAINTENANCE V4 RBLMK34_04 October 2014

BHARAT HEAVY ELECTRICALS LIMITED

A representative from Occupational Health is to be involved in the commissioning process to address any Respiratory Protection Program requirements.

for industry.com

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

This specification describes the minimum requirements for piping systems for the following service:

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

ANSI ORIFICE FLANGES METAL-KOREA

MTS AND MTS PR¼ 16 OUTPUT SEQUENTIAL TIMER PENTAIR CLEAN AIR SYSTEMS

Note: Do not bury sulphur dioxide lines Use stainless steel pipe and fittings only where specified on project drawings.

STANDARD PHRASEOLOGY SECTION G. 1. This section of standard phraseology is for general use in piping disciplines.

Trade of Metal Fabrication. Module 5: Pipe Fabrication Unit 3: Flanges Phase 2

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

Products catalogue (I-P Edition)

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

STANDARD PHRASEOLOGY SECTION G. 1. This section of standard phraseology is for general use in piping disciplines.

Product Guide Specification

DEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN )

No September, Char-Lynn. Power Steering. Repair Information. 20 Series Steering Control Unit 001

TABLE OF CONTENTS A-1

Table Of Contents Casing Head 02 Christmas Tree & Tubing Head Tubing Spool 04 Contact Us

Fisher 667 Diaphragm Actuators Size 80 and 100

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove

Specifications for EA31002 U Tube Bundle for CDU 3

This specification describes the minimum requirements for piping systems for the following service:

Technical Specifications: Supply of Seamless Grade TP304L Pipe and Grade WP304L Pipework Fittings to the ITER Organization (IO).

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

SUBMITTAL REVIEW Food Service Equipment Data Sheets GCAN. Notes: 1. See D-C Design comments. Submittal: No. 035.

No November, Char-Lynn. Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor

DETAILED ENGINEERING OF PROCESS PIPING SYSTEMS

WATERFLUX 3000 Quick Start

PIPING NOMENCLATURE. Header Branch connection Valve Flange Expansion joint Expansion loop Pipe support Reducer Elbow

PRODUCT CATALOGUE. Major Features: Arc Bends Manufactured to: Pipestar now offering full-line of flanged Arcbends

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

Pump Replacement Manual. Bill Wallace by Wallace Marine Services, Inc.

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

Stepping ahead in technology & innovation PIPING INSTITUTE OF TECHNOLOGY & ANALYSIS SOLUTIONS

Lockformer / 16 Gauge Speednotch

DNVGL-CP-0212 Edition March 2016

The DeltaGrip System. Safety and Operating Instructions. Trigger. Air Supply Connection. Handle Assembly. Air Line Assembly.

TECHNICAL SPECIFICATION FOR ANNUBAR (DELTA TUBE)

Drawings & Documentation Rotary Compressors

Quality Management system to Enhance Offshore & Subsea ESP Run life and Reliability Reda Elmahbes Baker Hughes / Mohamed Elmhabbes Saipem Libya

Multi-Bowl Applications

Appendix E Part Details for the PT20 with Standard Bypass Valve

Select, wear adjust, use and maintain personal protective equipment

Sheet Metal Worker A Guide to Course Content

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

WATERFLUX 3000 Quick Start

FORM A-1P MANUFACTURER'S DATA REPORT FOR PLATE HEAT EXCHANGERS As Required by the Provisions of the ASME Code Rules, Section VIII, Division 2

SAMAMAT FLOW CONTROL L.L.C.

SECTION THERAPEUTIC POOL ACCESSORIES

Sight glass (Low pressure) Types SG, SGI, SGN, SGR, SGRI and SGRN

CONSTRUCTION STANDARD FOR PLANT PIPING SYSTEM

STANDARD SPECIFICATION FOR FABRICATION & ERECTION OF PIPING

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

PLD-E-2007 Piping Design & Technical Office Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Scope/Purpose of SI Training:

Hospital Grade Welded Ceiling System

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

Comparison that shows the differences between a PFD and P&ID :

General Four-Way Operation, Maintenance & Service Manual

PLACE LOGO HERE. Final Project Report 10/02/2014. Chemical Clean & Oil Flush of Company 1 Lube Oil & Control Oil Systems.

Char-Lynn Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor November, 1996

CV Control Valves Installation and Operation Manual

Clayton Off Road COR COR COR

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

GENERAL ISOMETRIC LAYOUT

RHINO II Bottom Drain Installation Instructions

Symphony II Adaptable Table System

Installation and Specification Manual December 2012

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

Gas Solutions. Perfection Permasert 2.0 Gas Coupling Installation Guide

TOOLS FOR THE SPECIALIST UNDERWATER TOOLS

WHO WE ARE. ITS holds a Certificate of Authorization Permit (CAP) under the AB-5I5 program from ABSA.

BRAZING PROCEDURE SPECIFICATION NO

Asme B31 1 Power Piping Design Standard Certification

Series 760 Heavy Duty Fixed Displacement Motor. Parts and Repair Manual

HSB Global Standards ASME Code Changes and Discussions

METAL FABRICATION SECTION 8: METAL FABRICATION SCOPE MATERIAL.

Satish Lele M:

Design Guide for Hot Dip Galvanizing best practice for venting and draining

4 Briefing. Responsible investor

PLAN CEILING FRAMING PLAN CEILING JOIST SCHEDULE. Tenant Improvements. UNLV Police Station Maryland Parkway.

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Multi-Set II Drop-In Anchors

Digitally Signed 06/02/2015

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

INSTALLATION GUIDE StreamLine Linear Drain

Transcription:

ATTACHMENT A (1/1) TYPE OF PIPING PRESSURE TESTING TEST TYPE TEST MEDIUMS APPLIED (As per Block Dia.) WORK SEQUENCE HYDROSTATIC Water * For SS/HA piping Max. Cl. 40 ppm General CASE-1 (Base Case) CASE-2 (When app. by NIOEC) check/ Dry out PNEUMATIC * Oil free air for IA to air-operated valves and N2 for unit 02 Large Dia Piping - line - Flare - Gas CASE-1 (Base Case) CASE-2 (When app. by NIOEC) check/ blowing blowing IN SERVICE Service Fluid Only Approved by NIOEC check/ Flushing/ Blowing Service test Note for line For large diameter piping hand wipe/ sweep should be applied as much as possible (inspection to be recorded).

ATTACHMENT B (1/2) PIPING TEST PACKAGE (TP) FLOW CHART REVIEW / LINE CHECK / PUNCH LIST EXECUTION (PUNCH OUT/ LINE CLEANING/ PRESS. TEST/ POST TEST) DOCUMENTATIO N (FINAL DOCUMENT CONFIRMATION) RECORD EMPLOYER (NIOEC) - Review -line check QC Gr. Piping Gr. -Review -Register - Review QC items -Review -line check Working copy TP Copy Keep by contractor (&NIOEC) Working copy CONST. TP Copy TP Original Keep by CC -Execution TP Original Keep by CC & finally submit to NIOEC - CC will prepare original TP and one copy for working LEGEND: Working copy TP flow Original TP flow Original TP (*) working copy TP flow

ATTACHMENT B (2/2) DETAIL WORK FLOW FOR A/G TEST PACKAGE DOCUMENT HANDLING/ LINE CLEANING/ PRESS. TEST/ POST TEST ACTIVITY TEST PACKAGE LINE CHECK NIOEC//PUNCH OUT LINE CLEANING PRESS. TEST POST TEST TIME/PERIOD Three Weeks Before ing One Week Immediately after testing EMPLOYER (NIOEC) - check - QC document review Confirmation of Witness Witness Check Copy of test pack. - check - QC document review Confirmation of Witness Witness Check Copy of test pack. Two Copies Notice No Ok Notice No Ok CONST. Package preparation Follow up Punch Item -Preparation of line (R)* -Preparation of line (R)* -Drain out -(Drying) - Post (R)* - Finalize test package * (R) Inspection record required. TEST PACKAGE : - Contents Refer to Package Contents T TO INSTALL - PSV - Control valve - Thermwell - Strainer element - Orifice plate - All instruments - Disconnect all inst. - Lead pipings INSTALLATION - Control valve - Thermwell - Strainer element - Level Instrument REMOVE - Temporary blind - Other temp. part INSTALLATION T TO INSTALL - PSV - Orifice plate * Spring Hanger set pin do not remove Note 1: NIOEC / Contractor conformation is required.

ATTACHMENT C (9/16) PIPING SPOOLS SHOP FABRICATED ISO DRG : INSPECTION SPOOL : Relase Report LINE : CHECK ITEMS 1 CONFORMITY WITH ISO DRG (CONFIGURATION, DIMENSIONS, SIZE, ) 2 PIPE MATERIAL & THIKNESS. CORRECT 3 FLANGE MATERIAL & RATING. CORRECT 4 TYPE & MATERIAL OF FITTINGS, VALVES & OTHER COMPONENTS (if any) CORRECT 5 WELDING COMPLETED, VISUALLY INSPECTED. EXT. & INT (if possible) & ACCEPTED 6 NDE (RT,PT,MT) COMPLETED AND RESULTS STATIS FACTORY 7 PWHT AND HARDNESS TEST COMPLETED SATIS FACTORILY 8 OLETS FOR INSTRUMENTS CONNECTIONS CORRECTLY INSTALLED (LOCATION & ORIENTATION) 9 INSTRUMENT FLANGES TO PIPE WELDED JOINTS ARE INTERNALLY FLUSHED. (SMOOTHED) 10 INTERNAL PARTS OF VALVES & OTHER COMPONENTS PRONE TO DAMAGE WERE REMOVED BEFORE WELDING OR OTHERWISE PROPERLY PROTECTED. 11 VISUAL INSPECTION OF SPOOL FOR DAMAGE (SPECIALLY FLANGE FACES) 12 CLEANINESS OF THE SPOOL EXTERNALLY & INTERNALLY ACCEPTED OTHERS: CONS. CONT. NIOEC FABRICATION & INSPECTION COMPLETED PIPE SPOOL RELEASED FROM WORK SHOP CONS. TOTAL SHOP PREFAB. WEIGHT (kg) = NIOEC

LINE ISOMETRIC JOINT NATIONAL IRANINAN OIL ENGINEERING AND CONSTRUCTION COMPANY SIZE INCH WELD TYPE WELDER LOCATION DATE WELDED LINE HISTORY SHEET VISUAL RT PT MT P.W.H.T Report DATE Rep1 Rep2 Rep3 ACCEPT RJ1 RJ2 ACCEPT No. ATTACHMENT C (10/16).: TEST PACKAGE No.: TEST BLOCK No.: P&ID No.: HARDNESS P.M.I Construction Contractor Q/C Contractor NIOEC NAME: NAME: NAME: SIGN & DATE: SIGN & DATE: SIGN & DATE: