Outdoor, CCTV or CCTV, Fig 8 Armored.

Similar documents
Outdoor, Fig 8 Armored, Multi Tube

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

SPECIFICATION. Optical Fiber Cable

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

Single-Armored Cables, Fibers

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Ø 1250 * 688 mm 93 kg ± 105m

Standard Monotube SAFE

Outside Plant All Dielectric

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Fiber Optic Outside Plant Cables (4-144 Fibers)

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

features and benefits

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Optical Systems Contents

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Ø560*336mm 4.25 kg 2100 ± 105m

Datasheet Outside Plant Cable

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

FiberHome Fiber Products

Exhibit A Construction Project Manual and Drawings

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

FTTH Fiber Optical Cable

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

OFS AllWave non-dispersion shifted single-mode optical fiber

Nufern 980 nm Select Cut-Off Single-Mode Fiber

CommunicationCables FIBER OPTICS OPGW FTTH

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

u n a B Optical Cables UNIFLEX CABLES LTD.

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

Fibre Optic Indoor/Outdoor Cable

Industrial Automation

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

Type QG-G50-2C- M-BU

Integrating Global Communications...

Fiber Optic Principles. Oct-09 1

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Electric cables. Cranes

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

CXP/CFP 100G MPO Cable Assembly

Total care for networks. Introduction to Dispersion

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Introduction.

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

COPPER + LWL RAW CABLES

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

Copper and Fiber Optic Cables

TECHNICAL ARTICLE: DESIGN BRIEF FOR INDUSTRIAL FIBRE OPTICAL NETWORKS

NETWORK CONNECTIVITY SYSTEMS

HIGH POWER DFB LASERS

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

kv: medium voltage reeling cable with fibreoptics

af-phy July 1996

GIGABIT ETHERNET. e-ready Building Next Generation IT infrastructures. The Cabling Partnership. Mike Gilmore Managing Director, e-ready Building

For Public Comment DRAFT MALAYSIAN STANDARD STAGE : PUBLIC COMMENT (40.20) DATE : 01/10/ /11/2015

HIGH BIT RATE OPTICAL FIBRE NETWORKS - optical fibre selection and implementation

Optical Fiber Technology. Photonic Network By Dr. M H Zaidi

1.25 Gbps Bi-Directional single fiber SFF transceiver

Chapter 3 Signal Degradation in Optical Fibers

PERFORMANCE SPECIFICATION SHEET

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Ultra High Power 980nm Pump Laser Module - Grating Stabilized, 750mW

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

DISPERSION COMPENSATING FIBER

DRAFT MALAYSIAN STANDARD. Telecommunication cable: Single-mode optical fibre cable - Loose tube type for aerial installation

Migration to 50/125 µm in the Local Area Network

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Information technology. Generic cabling systems, General requirements

Light Guide Overview

Multimode fiber media types for 802.3cd

ABOUT US ABOUT US 1 CRANE CABLES

Optical Fiber Attributes

Filled Solid ALPETH Cable

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Advanced Fibre Testing: Paving the Way for High-Speed Networks. Trevor Nord Application Specialist JDSU (UK) Ltd

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

NATIONAL RADIO ASTRONOMY OBSERVATORY GREEN BANK, WEST VIRGINIA ELECTRONICS DIVISION TECHNICAL NOTE NO. 168

Transcription:

Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM, FDDI Fiber channel and others. Cable Structure Outdoor, CTV or CCTV Fig 8 Armored fiber optic cable Singlemode and 50 or 62.5 /125um, multimode color coded fiber Single loose tube The interstices between the fibers filled with suitable waterproof compound. Filling compound is non hygroscopic, electrically non conductive, homogenous and free from any metallic or foreign particle Self supporting (Figure 8) provided by stranded galvanize steel wire Black HDPE jacket or other each PE, LDPE, MDPE, and LSZH with customer requested Feature High tensile strength of stranded galvanizes steel wire meet requirement of self supporting and reduce the installation cost. Excellent mechanical and temperature performance. High strength loose tube that is hydrolysis resistant. Special tube filling compound ensure a critical protection of fiber. Messenger wire size 7x 1.0 +/ 0.1mm (3.0mm) stranded galvanizes steel wire for tensile strength. Small diameter and light weight. Designed for aerial installation with strand messenger wire. Fiber Optic Cable in accordance with Standard as below. ISO 9001:2008 RoHS compliant 2002/95/EC ISO/IEC 11801:2002 IEC 60793 ANSI/TIA/EIA 568 B.3 IEC 60794 1 2 ANSI/TIA 568 C.3 IEC 60794 1 2 E1A ANSI/ICEA 640 IEC 60794 1 2 E3 ITU T G.652D (Singlemode) IEC 60794 1 2 E4 ITU T G.651 (Multimode) IEC 60794 1 2 E6 Telcordia (Bellcore) GR 20 CORE IEC 60794 1 2 E7 IEC 60794 1 2 F1 IEC 60794 1 2 F5 IEC 60794 1 2 E11B EN 50173 1 EIA 455 TIS 2165 2548 Page 1 of 5

Optical Fiber of Singlemode as detail below. Table for the Optical, Geometrical Performance of the Singlemode Fiber (The specification confirms to the requirement of ISO/IEC 11801:OS2, ANSI/TIA 568 C.3 IEC 60793 2B1.3, ITU T G.652D) Specification Fiber Type 9/125um(OS2) Max. / typical attenuation 1310 nm 0.36 / 0.34 db/km. 1383 nm 0.36 / 0.32 db/km. 1550 nm 0.25 / 0.21 db/km. 1625 nm 0.35 / 0.24 db/km. Core Mode Field Diameter 9.2 0.4 um @ 1310 nm 10 0.6 um @ 1550 nm Cladding Diameter 125 1.0 um Coating Diameter 250 5.0 um Cladding Non circularity 1.0 % Core/Cladding Concentricity error 0.5 um Coating/Cladding Concentricity error 12 um Zero Dispersion Wavelength 1300 ~ 1324 nm Zero Dispersion Slope 0.092 ps/(.km) Cut off Wavelength 0 (Fiber) 1150 ~ 1330 nm (Cable) 1260 um Proof Test Stress 100 Kpsi Chromatic Dispersion ; 1285 ~ 1340nm 3.5 ps/nm.km = 1550nm 18 ps/nm.km =1625nm 22 ps/nm.km Polarization mode dispersion (PMD) 0.20 ps/ km Fiber Curl 4M Numerical Aperture 0.130 0.010 Group refractive index 1.469@1310nm and 1550nm Page 2 of 5

Optical Fiber of Multimode as detail below. The optical, Geometrical Performance of the Multimode Fiber (The specification conforms to the requirement of ISO/IEC 11801, ANSI/TiA 568 C.3, IEC 60793 2A1a, IEC 60793 2A1b, ITU T G.651) s Specifications Fiber Type 62.5/125 um 50/125 um 50/125 um (OM1) (OM2) (OM3) Max. /Typ. Attenuation 850 nm 3.0/ 2.7 2.7/ 2.5 2.7/ 2.3 (db/km) 1300 nm 0.8/ 0.6 0.8/ 0.7 0.8/ 0.6 Bandwidth 850 nm 200 500 1500 (MHz/Km) 1300 nm 600 500 500 850 nm Laser Bandwidth (MHz/km) N.A N.A 2000 Core Diameter (um) 62.5 ± 2.5 50.0 ± 2.5 50.0 ± 2.5 Cladding Diameter (um) 125 ± 1 125 ± 1 125 ± 1 Core Non circularity (%) 5 5 5 Cladding Non circularity (%) 1.0 1.0 1.0 Core/Cladding Concentricity error (un) 1.5 1.5 1.5 Coating Diameter (um) 245 ± 5 245 ± 5 245 ± 5 Colored Fiber Diameter (um) 250 ± 5 250 ± 5 250 ± 5 Coating Non circularity (%) 5 5 5 Coating/Cladding Concentricity error (un) 6 6 6 Proof test Stress (kpsi) 100 100 100 Bending Loss @ 850 & 1300 nm (100 turns, D=75 mm) 0.5 db 0.5 db 0.5 db Zero Dispersion Wavelength 1320 ~ 1356 nm 1297 ~ 1316 nm 1297 ~ 1316 nm Zero Diapersion Slope (ps/(nm 2..km)) 0.097 0.101 0.101 Numerical Aperture 0.275 ± 0.015 0.200 ± 0.015 0.200 ± 0.015 Group refractive index 1.496 1.483 1.483 Page 3 of 5

CABLE CONSTRUTION The Construction of the cable shall be in accordance with Table below. Construction of Outdoor, CTV Stranded Drop wire, Armored, fiber optic cable. s Specifications Number of fiber 4, 6, 8, 12 Core PBT (Polybutylene Terephthalate) Loose tube Outer Diameter 3.0~4.2 ± 0.2 mm Color Natural Filling Compound Thyrotrophic jelly compound Water Blocking Tape Thickness 0.3 ± 0.05 mm Ripcord Polyester Cord Armored 0.25 mm; Corrugated Steel Tape Coated with Polymer Sheath UV Proof, Black HDPE Thickness 1.5 ± 0.2 mm Web Thickness 1.5 1.0 mm Messenger Wire Galvanize Steel Wire Diameter 7 1.0 ± 0.1 mm (3.0 mm) Water Resistant Test Sample 3m/water 1m/1h Cable Diameter (Approx.) 8.6± 0.2 mm Overall Diameter (Approx.) 14.5 ± 0.5 mm Cable Weight (Approx.) 122 ± 10 kg/km TEPERATURE RANGE For the cables covered by this specification. The Following temperature range apply. Operation Temperature : 40 C to + 70 C Installation Temperature : 40 C to + 70 C Storage/Shipping Temperature : 40 C to + 75 C MECHANICAL SPECIFICATION Maximum Span Length Maximum Wind Velocity Maximum Tensile Load Maximum Crush resistance Minimum Bending Radius Table Mechanical Specification of the cable Specification 60 m 100 km/hr Installation 6000 N Operation 3000 N 4400 N/10cm Installation 20 Cable Diameter Operation 10 Cable Diameter Page 4 of 5

FIBER AND LOOSE TUBE IDENTIFICATION The color code of the loose tubes and the individual fibers within each loose tube shall be in accordance with Table below TIA/EIA 598 C (Rev. TIA/EIA 598 A) and EIA 359 A Color Code for Fiber and Loose tube Identification. Table TIA/EIA 598 C Color Code For Fiber and Loose tube Identification No. Fiber color 1 Blue 2 Orange 3 Green 4 Brown 5 Slate 6 White 7 Red 8 Black 9 Yellow 10 Violet 11 Rose 12 Aqua MECHANICAL PERFORMANCE TEST Standard Standard IEC TIA/EIA Old New Revision Tensile loading Test TIA/EIA 455 33A IEC 60794 1 E1A IEC 60794 1 2 E1A Compression Test TIA/EIA 455 41A IEC 60794 1 E3 IEC 60794 1 2 E3 Repeated Bending Test TIA/EIA 455 104A IEC 60794 1 E6 IEC 60794 1 2 E6 Impact Test TIA/EIA 455 25B IEC 60794 1 E4 IEC 60794 1 2 E4 Cable Bending Test IEC 60794 1 E11B IEC 60794 1 2 E11B Cable Twist or Torsion Test TIA/EIA 455 85A IEC 60794 1 E7 IEC 60794 1 2 E7 Temperature Cycling test TIA/EIA 455 3A IEC 60794 1 F1 IEC 60794 1 2 F1 Water Penetration Test TIA/EIA 455 82B IEC 60794 1 F5 IEC 60794 1 2 F5 Ordering Information Descriptions Part Number 4 core 6 core 12 core FIG 8 Armored, SM. 9/125um(OS2) FIG 8 Armored, MM. 62.5/125um(OM1) FIG 8, Armored, MM. 50/125um(OM2) FIG 8 Armored, MM. 50/125um XG(OM3) BELL SMAA09U04C BELL SMAA09U06C BELL SMAA09U12C BELL MMAA50U04C BELL MMAA50U06C BELL MMAA50U12C BELL MMAA62U04C BELL MMAA62U06C BELL MMAA62U12C BELL MMAA50XGU04C BELL MMAA50XGU06C BELL MMAA50XGU12C Page 5 of 5