WHEN A PLC IS TOO MUCH, AND SPACE FOR

Similar documents
Solid-State Digital Counter H7AN

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Multi Function Timer with Free power, Compact size W38 H42mm

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

FC Series Signal Conditioners

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Fuzzy Temperature Controllers E5AF

MODEL: MRP6. Final Control Elements

MODEL: KS. Plug-in Signal Conditioners K-UNIT

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

Indicator (4digit) (5digit) 8-pin plug counter

Analog Timer TTL Series

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Solid-state Timer H3DE

SLIM COMPACT SAFETY RELAY

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

Ultraminiature Photoelectric Switches with Self-contained Amplifier


Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition)

instabus EIB product documentation

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Solid-state Timer H3DS

LOW-PROFILE SURFACE-MOUNT RELAY

EIB/KNX Switch Actuators. User manual

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Suitable for lighting and motor load, 1 Form A 50A latching relays

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

Slim compact safety relay

Two outputs: contact and non-contact

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

27/04/2015

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Section 11 Electronic Position Controls & Encoders

354B SERIES SHAWNEE II High Speed Predetermining

General Specifications

Series 10-ZSE30A(F)/10-ISE30A

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

Self-Powered Counters H7ET

Safety Precautions. Copyright / Trademarks

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

APPENDIX APPENDIX A 1

LOW PROFILE 2 FORM C RELAY TQ RELAYS Ð Ð.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC. 200 mw.

Series 354. SHAWNEE II High-Speed Digital Predetermining Counter. The 354B Directly Replaces 354A. COUNTERS PRODUCT HIGHLIGHTS

T ime Delay Relays General information

onlinecomponents.com

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance


Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types

KCM-50/51 Series. Consolidated Counter (Maintenance Counter) Features KCM-50 Series. KCM-51 Series. Electronic Counter / Controller.

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Type Nominal voltage (V) Code HSV V

K-BUS Switch Actuator

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

2000 h at 25 C Battery, charging time h at 25 C Battery, charging time. 8 mm 8 mm via push-button decade switches

The operator interface consists of an LCD and eight keys. Use the interface to program and operate the triggering controller.

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

Temperature Controllers E5 J

Monostable multivibrators

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

PIR6WT-1Z interface - time relays

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

83 SERIES. 83 Series - Modular timers A. Features

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Multifunctional counter tico 772/773/774

Featuring a 100 μs sampling period and ±0.1% linearity

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

How to Guide: Controlling Blinds in C-Bus

Maximum Value for OEMs SM. NX70 High-speed Counters (NX70-HSC1, NX70-HSC2) User Manual

Bulletin 700-HX Multifunction Digital Timing Relay

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

Instruction manual. art Installation manual

ECET 211 Electric Machines & Controls Lecture 7 Relays. Lecture 7 Relays

S11 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification

Rotational speed controller


General Specifications

4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

Electronic Circuit Protector ESX10-T

Transcription:

WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than relay sequence circuits Just wire the power supply, inputs and outputs and your finished. A wide operating voltage : 100V to 240V AC. A built-in power supply (24 V/200 ma) One-touch mounting to the DIN rails mm inch s Pattern Selector (AC) AFK-6DR-AC General specifications Rated operating voltage 100 to 240V AC (50/60 Hz) Operating voltage Momentary stoppage Rated power consumption Sensor power supply Operating temperature Storage temperature Operating humidity Storage humidity Breakdown voltage Insulation resistance Vibration resistance Shock resistance Noise resistance Functional Destructive 85% to 110% Continuous operation after stoppages of less than 10 ms 0.3 A max. 24 V DC±10%, 200 ma 10 to 55 C +14 to 131 F 20 to 70 C 4 to 158 F 30% to 85%RH (without condensation) (at 20 C) 30% to 85%RH (without condensation) (at 20 C) *One minute at AC 1,500V Operating power terminal I/O terminal Operating power terminal power terminal Operation power terminal earth terminal Output terminal earth terminal Input terminal output terminal Output terminal 1 output terminal 2 *One minute at 500 V AC Earth terminal output terminal Earth terminal power terminal Input terminal power terminal Min. 100 MΩ between each of the above terminals (with DC 500 mv insulation tester) 10 to 55 Hz sweeps/minute Compound amplitude 0.5 mm.020 inch in each axis (X, Y, Z), 10 min. 10 to 55 Hz sweeps/minute Compound amplitude 0.5 mm.020 inch in each axis (X, Y, Z), 1 hr. Functional 98 m/s 2, 4 impacts in each axis (X, Y, Z) Destructive 980 m/s 2, 4 impacts in each axis (X, Y, Z) 1,000V (with noise simulator) Timer specifications Timer points Timer precision 4 (T1 through T4) 2 timer potentiometers 4 settings (1 sec., 10 sec., 1 min., 10 min.) Setting error: Max. ±10% Repeat accuracy: Max. ±1% Temperature error: ±2% Note: Time settings are the same for both timers in the pair (T1/T3 or T2/T4). Use timer setting potentiometer 1 to set timers T1 and T3, and timer setting potentiometer 2 to set timers T2 and T4. Input specifications Input points Type of input Input ON voltage/ ON current Input OFF voltage/ OFF current Input impedance Minimum input pulse width Operation indication Method of external connection Method of insulation Output specifications Output points Output method Rated control capacity Input response time Mechanical life Electrical life Operation indication Method of external connection 4 points No-voltage contact or NPN open collector Up to 20.4V/up to 4 ma Up to 4.8V/up to 1 ma 4.7 kω (approx.) 3 ms LED Terminal board (M3.5 terminal screws) Optical coupler 2 points 1 a 5 A, 250 V AC; 5 A, 30 V DC OFF ON, 10 ms max. ON OFF, 5 ms max. 20 million operations minimum 1 million operations minimum LED Terminal board (M3.5 terminal screws) 53

Component Power Input Terminal 9 Frame Grounding Terminal Output Terminals COM COM 9 Sensor Power Output Terminals Input Terminals Time Range Selector Switch Timer Set Potentiometers Pattern Selector Switch Operation Indicator LEDs Preset Patterns A1: Bi-directional Limit Control (continuous input) A2: Bi-directional Limit Control (momentary input) A3: Timed Operation Control A4: Two Sequence Limit Control with Timed Operation A5: Timed and Instantaneous Event Monitoring A6: Annunciator Control A7: Time Delay Sequence Control A8: Manual Refill Control with Event Monitoring B1: Time Delayed Output Reversing B2: One-Shot Output B3: Output Reversing B4: AND Logic B5: OR Logic B6: Leading Edge Input/ One-Shot Output B7: Trailing Edge Input/ One-Shot Output 54

A1 Bi-directional Limit Control (continuous input) Shutter Upper limit limit IN 4 Ou Ou Upper limit switch button limit switch button Operation: Turn the pattern switch and dial to indicate pattern A1. Power is On. Inputs 1 & 2 are used to energize Outputs 1 & 2 which can be wired to raise/lower an elevator or open/close window shutters etc. The outputs are energized only as long as the momentary input switches are held closed. is an upper limit switch which activates. de-energizes after the selected time period has elapsed. is a lower limit switch which activates. de-energizes after the selected time period has elapsed. A2 Bi-directional Limit Control (momentary input) Upper limit limit IN 4 Stop button Ou Ou Upper limit switch button limit switch button Operation: Turn the pattern switch and dial to indicate pattern A2. Power is On. Momentary contact switches on Inputs 1 & 2 are used to energize Outputs 1 & 2 which can be wired to raise/lower an elevator or open/close window shutters etc. The outputs are energized and latched until (upper limit switch) or (lower limit switch) is activated. A Stop switch can also be added in parallel with the limit switches to provide the capability to stop operations midway if needed. Timers 1 & 2 provide a short delay before Outputs 1 & 2 energize to eliminate any contact chatter in the momentary switches. A3 (1) Timed Operation Control Application Example Both hands are used to operate Wiring Schematic Timing Chart Press Cylinders START A START B STOP Press Ou Ou Stop button Start button A Start button B Operation: Turn the pattern switch and dial to indicate pattern A3. Power is On. Momentary contact switches on Inputs 1 & 2 are pressed simultaneously to energize and. can be wired to start a pressing or imprinting machine, etc. The output remains energized until times out. A Stop switch can also be added to Input 3 to provide the capability to stop operations midway if needed. A3 (2) Timed Operation Control Parts full ON OFF IN 4 Ou Ou On Off Start switch Full detection switch Operation: Turn the pattern switch and dial to indicate pattern A3. Power is On. A sustained contact On/Off switch on is turned On to energize which can be wired to start a parts feeder, etc. The output remains energized until a switch on actuates and times out. 55

A4 Two Sequence Limit Control with Timed Operation START button Pressing cylinder Sectioning cylinder Pressing Sectioning Sectioning limit IN 4 Upper limit limit Ou Ou Press Extrude Upper limit switch Start button Sectioning limit switch limit switch Operation: Turn the pattern switch and dial to indicate pattern A4. Power is On. When the momentary contact switch connected to is pressed, is energized. can be wired to start a pressing or imprinting machine, etc. The output remains energized until the limit switch on is actuated and starts and times out. When the upper limit switch connected to is actuated, the second sequence begins by energizing. This output can be wired to start a sectioning or extruding machine, etc. When the limit switch connected to is actuated, turns off. For setups requiring the simultaneous pressing of two pushbuttons, connect both switches (wired in series) to. A5 Timed and Instantaneous Event Monitoring Sensor Warning An indicator lamp or other type of warning mechanism Interlock Contact Ou Ou Belt motion Interlock contact Operation: Turn the pattern switch and dial to indicate pattern A5. Jumper. Power is On. is on. This output can be connected to a motor start/stop circuit. A, whose contacts alternate from opened to closed during normal machine operation (eg. conveyor belt speed ) in connected to. is set to the maximum acceptable time the contact can be closed. is set to the maximum time the contact can be opened. When remains on or off beyond the preset time (eg. conveyor belt slippage or break), is turned off and is turned on. can be wired to an indicator lamp or annunciator circuit. When returns to normal, the outputs will return to their normal state. The jumper on can be replaced by another (normally closed contact) to interlock operation with another device. When the contact opens, immediately turns off and turns on. A6 Annunciator Control Flashes Warning Lights Warning A Warning B Intermittent sound Warning Continuous sound Abnormality 1 IN1 Abnormality 2 IN2 Abnormality 3 IN3 Abnormality 4 IN4 Ou Ou Warning Sensor B Warning Sensor A Alarm Sensor B Alarm Sensor A / 3 / 4 / 2 / 2 Timer 3 / 4 t3 Operation: Turn the pattern switch and dial to indicate pattern A6. Power is On. When a normally open contact (Warning Sensor A) connected across is closed, Output 1 will cycle on/off based on the interval set by Timers 1&3. If a similar contact (Alarm Sensor A) on is closed while is cycling, will stay on continuously. If opens, will begin to cycle again. If both inputs open, will turn off. Inputs 3 and 4 (Warning Sensor B & Alarm Sensor B), Timers 2&4, and perform the same function. A7 Time Delay Sequence Control Material Material A B START button Valve A Valve B Ou Ou STOP button A Stop button A Start button Stop button B IN 4 STOP button B Operation: Turn the pattern switch and dial to indicate pattern A7. Power is On. When a momentary contact switch connected to is pressed, is energized. can be wired to start a control valve or motor starting circuit, etc. The output remains energized until times out. then turns on and remains energized until times out. This can be used to control a simple batch mixing system feeding two ingredients. Inputs 3 and 4 can be wired to individual pushbuttons to turn off Outputs 1 & 2 individually, or to a single pushbutton switch to shut down the sequence pletely. 56

A8 Manual Refill Control with Event Monitoring Indicator lamp START button Valve Indicator Ou Ou Material flow switch Start button High level switch / 3 / 4 t3 t4 Operation: Turn the pattern switch and dial to indicate pattern A8. Power is On. When a momentary contact switch connected to is pressed, Outputs1 & 2 are energized. can be wired to start a control valve or motor starting circuit, etc. would be wired to an indicator light. If the momentary contact switch is released, both outputs deenergize. Timers T1/T3 and T2/T4 are used in conjunction with Inputs 2 and 3 ( can be connected to a high hopper level switch and to a supply material flow switch). With energized, energizing (hopper full) will cause to turn Off and will cycle On/Off based on the setting of T1. cycling will stop and will turn back On when is released. With energized, energizing (material supply empty) will cause to turn Off and will cycle On/Off based on the setting of T2. cycling will stop and will turn back On when is released. Turning Off will turn both Outputs Off. B1 Time Delayed Output Reversing (Forward) (Reverse) Reverse mand Forced set (forward) Forced reset (reverse) Forward Reverse Ou Ou Reverse switch Forward/Reverse toggle Forward switch Timer 4 t4 t4 Operation: Turn the pattern switch and dial to indicate pattern B1. Power is On (when power is applied, will energize after time period T2). When a momentary contact switch connected to is pressed, turns off. After time delay T2, energizes. Pressing the momentary switch on again will cause the outputs to transfer ( Off instantaneous, On after T4). The outputs can be wired to a motor direction circuit to switch between forward and reverse. T2/T4 provides time for the motor to slow before reversing. Timer T1 prevents additional mands from reversing the outputs during its time cycle. Momentary contact switches can be connected to to force On (after T2), and to to force On (after T4). B2 One-Shot Output Message signal Lamp and buzzer Verification pushbutton Ou Ou Normally closed Input B Normally open Input A Acknowledge Input B Acknowledge Input A Operation: Turn the pattern switch and dial to indicate pattern B2. Power is On. When a normally open contact connected to is closed, is energized. The output remains energized until times out, or a normally open contact connected to is closed. When a normally closed contact connected to is opened, Output 2 is energized. remains energized until times out, or a normally open contact connected to is closed. B3 Output Reversing Diverter valve Diversion Set Reset Ou Ou switch (reset) Output toggle (diversion) switch (set) Operation: Turn the pattern switch and dial to indicate pattern B3. Power is On ( energized is the power on default). When a momentary contact switch connected to is pressed and held for time T1, Outputs1 & 2 change state ( energizes, deenergizes). Pressing and holding the momentary switch on again will cause the outputs to transfer. This pattern can be used for switching or diverting applications. Timer T1 eliminates chatter of the mand. Momentary contact switches 57

B4 AND Logic Sensor 1 Sensor 2 Ou Ou Input B1 Input A1 Input B2 Input A2 can be connected to and 3 to force output settings ( On; = On, = Off On; = Off, = On). Operation: Turn the pattern switch and dial to indicate pattern B4. Power is On. When contact closures are received at both Inputs 1 and 2 and are sustained for time T1, energizes. Loss of either input turns Off. When contact closures are received at both Inputs 3 and 4 and are sustained for time T2, energizes. Loss of either input turns Off. For a four-point AND circuit, connect Outputs 1 and 2 in series. B5 OR Logic Sensor Misalignment detection Sensor Ou Ou Input B1 Input A1 Input B2 Input A2 Operation: Turn the pattern switch and dial to indicate pattern B5. Power is On. When a contact closure is received at or 2 or both and is sustained for time T1, Output 1 energizes. Loss of all inputs turns Off. When a contact closure is received at or 4 or both and is sustained for time T2, energizes. Loss of all inputs turns Off. For a four-point OR circuit, connect Outputs 1 and 2 in parallel. B6 Leading Edge Input / One-Shot Output Yes No Presence Synchronization Ou Ou Presence Synchronization B7 Trailing Edge Input / One-Shot Output Yes No Presence Synchronization Ou Ou Presence Synchronization Operation: Turn the pattern switch and dial to indicate pattern B6. Power is On. is connected to a normally open presence detection, and is connected to a timing synchronization. A one-shot output goes to if is energized when the leading edge of the synchronization signal is received at. The oneshot duration is set by. A one-shot output goes to if is deenergized when the leading edge of the synchronization signal is received at. The oneshot duration is set by. This pattern can be used for workpiece detection and other input synchronization applications. Operation: Turn the pattern switch and dial to indicate pattern B7. Power is On. is connected to a normally open presence detection, and is connected to a timing synchronization. A one-shot output goes to if is energized when the trailing edge of the synchronization signal occurs at. The one-shot duration is set by. A one-shot output goes to if is deenergized when the trailing edge of the synchronization signal occurs at. The one-shot dura- 58