MODEL: TC10EM. Temperature Controller TC10 Series

Similar documents
MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

MODEL: R30US4. Remote I/O R30 Series

MODEL: RZMS-U9. PC Recorders RZMS Series

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

MODEL: M1EXT. with Display M1E Series

RZUS-U9 PC RECORDER MODEL. PC Recorders RZUS Series. (universal input, 12 points; isolated; bus-powered USB) MODEL & SUFFIX CODE SELECTION

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: W2TS. Mini-MW Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: SC110. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel, MV output backup) MODEL: SC110 [1]0 [2][3]

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

SHIMADEN DIGITAL INDICATORS

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

SHIMADEN DIGITAL INDICATOR

MICRO-CONTROLLER X (48mm 48mm)

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

General Specifications

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

MODEL: SC210. Single Loop Controller Series

SHIMADEN DIGITAL INDICATORS

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

General Specifications

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

SHIMADEN PROGRAM CONTROLLER

MICRO-CONTROLLER X mm

DC1010/DC1020/DC1030/DC1040

[3] MOUNTING DIRECTION

High Performance Process & Temperature Controllers

General Specifications

SHIMADEN DIGITAL CONTROLLER

Fuzzy Temperature Controllers E5EF

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

General Specifications

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

REX-F400 REX-F700 REX-F900

General Specifications

MICRO-CONTROLLER X (48 96 mm)

Excellent low-cost Process & Temperature Controllers

1/16 DIN (48 48 mm) temperature controller PXR

PROCESS & TEMPERATURE CONTROLLERS

MICRO-CONTROLLER X (48 48 mm)

Analogue temperature controllers

General Specifications

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: MRP6. Final Control Elements

APPENDIX APPENDIX A 1

DIGITAL PROGRAM CONTROLLER

MODEL: DLS. Telemetering System

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

General Specifications

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

General Specifications

General Specifications

MODEL: DAST-20. Telemetering System

HYBRID RECORDER OUTLINE

Multi-point Temperature Controller

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

Temperature Controllers E5 J

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1)

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

PROGRAMMABLE CONTROLLER

MODEL: WL40MW1F. Wireless I/O WL40F Series

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control

MICRO-CONTROLLER X (96 96 mm)

MODEL: M2DYS SEN TRONIC AG

MICRO-CONTROLLER X (48 96 mm)

Temperature Controller


INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

MICRO-CONTROLLER X (48 48 mm)

PROGRAMMABLE CONTROLLER

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

CompoBus/D-type Digital Controller

SHIMADEN DIGITAL CONTROLLER

General Specifications

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

SHIMADEN PROGRAMMABLE CONTROLLER

Models UT350/UT320 Digital Indicating Controllers

MODEL: KS. Plug-in Signal Conditioners K-UNIT

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

LT23A SERIES. Digital Indicating Controller PSE x48mm compact body Easy to use small size controller at reasonable price CE RoHS compliance

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

DISCRETE INPUT MODULE, 16 points

PID CONTROLLERS LT SERIES

Fuzzy Temperature Controllers E5AF

Digital indicator for panel mounting With multi-function input Model DI25

ADAM 4000/4100 Series

DIGITAL INDICATING CONTROLLER

Transcription:

Temperature Controller TC0 Series TEMPERTURE CONTROLLER (Modbus, 5 digit, LED display type, size 9 x 9 mm) Functions & Features Two PID controllers* Universal input x points, control output x points, discrete input x points, clamp-on current sensor input x points universal inputs configurable to T/C, RTD, DC current or voltage independently Discrete inputs usable to switch PID bank or operation mode Control outputs configurable to MV, PV or alarm Clamp-on current sensor input enables to detect heater wire break or over current uto tuning function *Only single loop control is available while loop remote SP is enabled. 9(3.8) 9(3.8) 08(.5) mm (inch) MODEL: TC0EM[]M ORDERING INFORMTION Code number: TC0EM-[]-M Specify a code from below for []. (e.g. TC0EM--M) [] CONTROL OUTPUT : 0 0 m DC (Load resistance 500 Ω max.) Open-collector points V: 0 0 V DC (Load resistance kω max.) Open-collector points P: V pulse (Load resistance 00 Ω max.) Open-collector points POWER C Power M: 00 0 V C (Operational voltage range 85 V, Hz) RELTED PRODUCTS PC configurator software (model: TC0CFG) Downloadable at M-System s web site. dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. Clamp-on current sensor (model: CLSE) (Used for detecting the heater wire break) GENERL SPECIFICTIONS Construction: Panel flush mounting Degree of protection: IP5; applicable to the front panel of the unit with single mounting according to the specified panel cutout Configuration jack:.5 dia. miniature jack connector; RS--C level Connection: M3 separable screw terminal (torque 0.5 N m) Solderless terminal: Refer to the drawing at the end of the section. Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd pplicable wire size: 0.5 to.5 mm (WG to ) Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (black) : Pv to Pv to CT or CT to Di or Di to MV or MV to Do or Do to Modbus to power CT Input waveform RMS sensing: Up to 5 % of 3rd harmonic content Control mode: Standard PID, heating and cooling control (ON/OFF, PID) Proportional band (P): 0. to 300.0 (temperature unit) Integral time (I): 0 to 3999 sec. Derivative time (D): 0.0 to 999.9 sec. uto-tuning: Limit cycle method larm: Deviation high & low, absolute high & low, etc. Sampling cycle: 00 msec. Control cycle:.0 to 99.9 sec. (00 msec. fixed for Mv output 0-0 m DC and 0-0 V DC) Mv output range: -5-05 % for output scale Parameters: Stored in non-volatile memory; write/erase cycle endurance: less than 000 000 Parameter setting: With front panel operation buttons or PC configurator software (model: TC0CFG) Universal input urnout Control output Loop TC0EM SPECIFICTIONS ES-958 Rev.3 Page /

ank Event input CT input uto-tuning Refer to the instruction manual for detail. Recommended solderless terminal (.) max 3.3 (.) max mm (inch) MODUS COMMUNICTION Communication: Half-duplex, asynchronous, no procedure Standard: Conforms to TI/EI-85- Transmission distance: 500 meters max. Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.) Node adress: to Data mode: RTU (inary) Parity: None, even or odd aud rate: 800, 900, 9. k, 38. k, 5. k (bps) Stop bit: or Node adress, parity, baud rate setting: With front panel operation buttons or PC configurator software (model: TC0CFG) Terminating resistor: uilt-in (Enable by shorting between pin and 5) DISPLY PV display: 5 digits -segment green LED, 9.5 mm (. ) height SP display: 5 digits -segment red LED,.5 mm (.9 ) height, switchable to MV display Display range: -3000 to 3000 Decimal point position: 0 to 0 or none Zero indication: Higher-digit zeros are suppressed. Loop status indicators Loop: mber LED turns on when loop chosen Loop: mber LED turns on when loop chosen ank: Green LED turns on when bank chosen ank: Green LED turns on when bank chosen ank3: Green LED turns on when bank 3 chosen ank: Green LED turns on when bank chosen larm: Red LED turns on at alarm larm: Red LED turns on at alarm larm3: Red LED turns on at alarm 3 larm: Red LED turns on while setting is saving to the non-volatile memory. Run: Green LED turns on while loop is in operation. Man: Green LED turns on during manual mode Local: Green LED turns on when local SP chosen t: Green LED turns on during auto-tuning Out: Green LED turns on when MV output Out: Green LED turns on when MV output SPECIFICTIONS Universal input, (Pv, Pv) For type and range configuration, refer to the instruction manual. DC Current: Input range: 0-0 m DC Input resistance: 9.9 Ω resistor incorporated DC voltage input Input resistance: 0 kω (-000 to 000 mv DC) Input resistance: MΩ (-0 to 0 V DC) Thermocouple Input resistance: 0 kω Input range: Refer to the table urnout sensing: μ Conformance range: Refer to the table RTD (-wire or 3-wire) Excitation: 0.33 m Input range: Refer to the table llowable leadwire resistance: 0 Ω per wire Resistance Excitation: 0.33 m llowable leadwire resistance: 0 Ω per wire Potentiometer Excitation: 0.33 m Input range: 0 to 000 Ω llowable leadwire resistance: 0 Ω per wire Clamp-on current sensor (CT, CT) (Sensor model No.: C input) CLSE-R5: 0 5 CLSE-05: 0 50 CLSE-0: 0 00 CLSE-0: 0 00 CLSE-0: 0 00 CLSE-0: 0 00 Frequency: 50 / 0 Hz (5-5 Hz) Max. working voltage: 80 V C (primary side) Overload capacity: CLSE-R5: 0 continuous, x0 ( sec.) CLSE-05: 0 continuous, x0 ( sec.) CLSE-0: 0 continuous, x0 ( sec.) CLSE-0: 0 continuous, x0 ( sec.) CLSE-0: 80 continuous, x0 ( sec.) CLSE-0: 0 continuous, x0 ( sec.) Operational range CLSE-R5: 5 CLSE-05: 50 TC0EM SPECIFICTIONS ES-958 Rev.3 Page /

CLSE-0: 00 CLSE-0: 00 CLSE-0: 00 CLSE-0: 00 Caution : The output values may vary depending on the accuracy of engagement at the clamp connection. Caution : The sensor s mechanical construction may cause it to generate resonance sound. However, it does not affect the perfomrance of the sensor. Discrete Input (Di, Di) Contact rating: 3.3 V @ m Detection levels: 5 kω / 0.5 V at close 350 kω /.5 V at open OUTPUT SPECIFICTIONS Four control outputs are configurable to Mv, o or Do. Control Output (Mv, Mv) Specify one type of output with the code number from 3 types shown below. DC Current: 0 0 m DC Operational range: 0 m DC Load resistance: 500 Ω DC Voltage: 0 0 V DC Operational range: 0 -.5 V DC Load resistance: kω V Voltage pulse Maximum frequency: Hz Minimum pulse width: msec. Hi level: V ±5 % Lo level: 0.5 V Load resistance: 00 Ω min. Control Output (Do, Do) Open collector Maximum frequency: Hz Minimum pulse width: msec. Output rating: 50 V DC 00 m (resistive load) Saturation voltage: 0.5 V DC PERFORMNCE in percentage of span ccuracy Pv or Pv: Refer to "Input type, range & conversion accuracy" section. CT or CT: ± % (sensor error margin not included) Mv or Mv: ±0.5 % Cold junction compensation error (thermocouple input): ±.0 C at 0 50 C (±3. F at 3 F) CJC sensor is adjacently attached to the input terminals. CJC is available for each universal input and. Temp. coefficient Pv or Pv: ±0.03 %/ C (± 0.0 %/ F) CT or CT: ±0.03 %/ C (± 0.0 %/ F) Response time CT or CT: sec. (0 90 %) Mv or Mv: sec. (0 90 %, DC output) urnout response (thermocouple, RTD input): 0 s Insulation resistance: 00 MΩ with 500 V DC Dielectric strength: 000 V C @ minute (Pv to Pv to CT or CT to Di or Di to MV or MV to Do or Do to Modbus to power to ground) STNRDS & PPROVLS EU conformity: EMC Directive EMI EN 000-- EMS EN 000-- Low Voltage Directive EN 00- Installation Category II Pollution Degree Input to output to power Reinforced insulation (300 V) Input or output or power to Modbus asic insulation (300 V) RoHS Directive EN 5058 INSTLLTION Power Consumption C: pprox. V at 00 V pprox. V at 00 V pprox. 8 V at 0 V Operating temperature: -0 to 55 C ( to F) Operating humidity: 5 to 90 %RH (non-condensing) tmosphere: No corrosive gas or heavy dust Mounting: Panel flush mounting Weight: 50 g (0.99 lb) TC0EM SPECIFICTIONS ES-958 Rev.3 Page 3/

TYPE, RNGE & CONVERSION CCURCY TYPE RNGE CCURCY DC CURRENT 0 to 0m DC ±0μ DC VOLTGE -000 to 000mV DC When max. range* is 0mV ±0μV When max. range* is 0mV ±30μV When max. range* is 0mV ±00μV -0 to 0V DC ±0mV ±0.% POTENTIOMETER Total resistance up to 000Ω* 3 ±0.Ω or ±0.%, whichever is greater RESISTOR 0 to 000Ω ±0.Ω or ±0.%, whichever is greater Thermocouple C F RNGE CCURCY CONFORMNCE RNGE RNGE CCURCY CONFORMNCE RNGE (PR) 0 to 0 ±.80 0 to 0 3 to 300 ±3. 3 to 300 K (C) -0 to 0 ±0.0-50 to 0-5 to 98 ±0. -8 to 98 E (CRC) -0 to 000 ±0.0-0 to 000-5 to 83 ±.08 - to 83 J (IC) -0 to 00 ±0.0-80 to 00-3 to 9 ±. -9 to 9 T (CC) -0 to 00 ±0.50-0 to 00-5 to 5 ±0.90 - to 5 (RH) 00 to 80 ±.00 00 to 0 to 3308 ±3.0 5 to 300 R -50 to 0 ±.00 00 to 0-58 to 300 ±.80 39 to 300 S -50 to 0 ±.00 0 to 0-58 to 300 ±.80 3 to 300 C (WRe 5-) 0 to 5 ±.00 0 to 5 3 to 99 ±.80 3 to 99 N -0 to 00 ±0.50-0 to 00-5 to ±0.90-0 to U -00 to 00 ±0.50-00 to 00-38 to ±0.90-38 to L -00 to 900 ±0.30-00 to 900-38 to 5 ±0.5-38 to 5 P (Platinel ll) 0 to 95 ±0.30 0 to 95 3 to 53 ±0.5 3 to 53 RTD C F RNGE CCURCY RNGE CCURCY Pt 00 (JIS 9, IEC) -00 to 850 ±0.0-38 to 5 ±0. Pt 500-00 to 850 ±0.0-38 to 5 ±0. Pt 000-00 to 850 ±0.0-38 to 5 ±0. Pt 50Ω (JIS 8) -00 to 9 ±0.0-38 to 00 ±.08 JPt 00 (JIS 89) -00 to 50 ±0.0-38 to 950 ±0. Ni 508.Ω -50 to 00 ±0.0-58 to 39 ±.08 Cu 0 (5 ) -50 to 50 ±.00-58 to 8 ±3.0 *.Thermocouple: dd.0 C of cold-junction-compensation error. *. Max. range: absolute range (greater of 0% and 00% range values), whichever is greater. *3. Refer to the operating manual for details. EXTERNL VIEW FRONT VIEW RER VIEW Cold Junction Compensation ( CJM) Loop status indicators Run Man Local T Out Out PV PV Display 3 Loop 3 3 ank uto/manu Local/Remote Esc SP MV larm Loop/ SP/MV Enter SP/MV Display 5 8 9 0 5 8 9 0 5 Config 8 9 30 Operation uttons Configuration Jack TC0EM SPECIFICTIONS ES-958 Rev.3 Page /

CONNECTION DIGRMS MSTER CONNECTION TERMINTOR HOST PC TC0EM TC0EM TX/RX * TX/RX SG RX RX D D NO. ID D FUNCTION D *. For using internal terminator, short-accross terminals and 5. DIMENSIONS unit: mm (inch) M3 Screw Watertight Sealing Mounting racket Terminal Cover 30 M3 Terminal Screw 0 (.33) 9 (3.8) 3 5 8 9 0 5 8 9 0 5 8 9 30 9 (3.) (.08) 9 (3.8) 8 (.3) 98 (3.8) 9 (3.) 00 (3.93) PNEL CUTOUT unit: mm (inch) 9 0.8 0 Pitch (5.9) 9 0.8 0 Pitch (.80) Mounting bracket: 0.5 0 (0.0 to 0.39) TC0EM SPECIFICTIONS ES-958 Rev.3 Page 5/

SCHEMTIC CIRCUITRY & CONNECTION DIGRM Pv UNIVERSL 3 /D Converter Indicator LEDs... Control Comm. 5 8 9 TERMINTOR MODUS D NC NC CT CT Pv UNIVERSL 5 5 /D Converter /D Converter Output Output 0 NC 5 8 9 30 Mv Do Mv Do Di Di 5 8 9 0 Input Display/ Setting 3 U() V () NC POWER JCK UNIVERSL CONNECTION (Pv) e.g. DC Voltage (-0 0V DC) DC Current (0 0m DC) UNIVERSL CONNECTION (Pv) e.g. DC Voltage (-0 0V DC) DC Current (0 0m DC) CT / CT CONNECTION e.g. Clamp-on current Sensor (model : CLSE) Power Side k l k l 5 DC Voltage (-000 000mV DC) DC Voltage (-000 000mV DC) Load Side DISCRETE CONNECTION e.g. Di Di 8 9 Thermocouple CJC SENSOR RTD/Resistor (3-wire) comp. leadwire Thermocouple CJC SENSOR RTD/Resistor (3-wire) comp. leadwire 0 CONTROL OUTPUT & CONNECTION e.g. 5 Mv Mv CONTROL OUTPUT 3 & CONNECTION e.g. 8 9 Do Do RTD/Resistor (-wire) RTD/Resistor (-wire) 30 Potentiometer Potentiometer MX MX MIN MIN TC0EM SPECIFICTIONS ES-958 Rev.3 Page /

Specifications are subject to change without notice. TC0EM SPECIFICTIONS ES-958 Rev.3 Page /