Samples from

Similar documents
3.1 General Provisions

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

UNDER-FLOOR PLAN SCALE: 3/16"=1'-0"

Sections & Details VOCABULARY

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

Garage Design Guide. October 2018

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

APPLICATION FOR A BUILDING PERMIT

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

Wood structures Copyright G G Schierle, press Esc to end, for next, for previous slide 1

E-Blueprints. Children s Backyard Playhouse 8 x sq. feet main 32 sq feet porch 2 x 4 Framed Walls 6' Ceiling Height

Shearwall System Installation Guide

FASTENERS BUILDING DEPARTMENT

24 X32 3 CAR GARAGE POLE BARN STYLE FRAME

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

PANEL NOTATION (3) D4 D3 D2 D3X2 SHEATHING THICKNESS (IN.) D " NAILS/ SPACING " o.c. SILL BOLT SPACING 1 2 " 36" O.C. 1 2 " Ø

WOODEN BUILDINGS 6.1 INTRODUCTION 6.2 TYPICAL DAMAGE AND FAILURE OF WOODEN BUILDINGS. Chapter 6

GlasRoc Sheathing Type X

Exterior Wall Fastener Schedule

Featuring TJ Rim Board and TimberStrand LSL

SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

MAT106: Wall Framing. AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products

A Shell construction

SECTION ROUGH CARPENTRY

GLOSSARY OF TERMS SECTION 8

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

Building for High Wind Resistance in Light-Frame Wood Construction

PART II ENGINEERED BASIS OF RIDGE AND EAVE VENT DETAILS

A - 1 ELEVATIONS ELEVATION 1/A1 ELEVATION 2/A1 PROJECT TITLE: CALLENDER HANDCRAFTED LOG HOME PREPARED FOR:

City of Long Beach Department of Development Services Building and Safety Bureau. Wood Frame Prescriptive Provisions For Residential Construction

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

STRUCTURAL WOOD DETAILING IN CAD FORMAT

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

Acceptable Standards of Domestic Construction

Construction Manual. 1. Delivery Day

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

Appendix C: Cheat Sheets Construction Manual

24" max from each end of the ledger. See detail 6A & 6B, typ. both ends IRC R Ledger R507.2

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

8x8 Shed Plans and Building Guide

ROOF-CEILING CONSTRUCTION

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

Casa de Dios. 16 x 20 House. Construction Plans

S001 LOWER LEVEL ISO SECOND FLOOR ISO S001 FULL ISO FIRST FLOOR ISO. O="Katahdin Engineering, LLC",

A. Rough carpentry includes but is not limited to the following:

KS SERIES - VERTICAL INSTALLATION

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

Section Downloads. Terminology Outline. Industry Standards/ Publications. American Softwood Lumber Standard ANSI/TPI 1. Section 02: Terminology

APA Performance Rated Rim Boards

MAT105: Floor Framing

Load Tables, Technical Data and Installation Instructions

10x10 Shed Plans and Building Guide

VERSA-LAM. An Introduction to VERSA-LAM Products

Drywall, Wood and Truss Uplift

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California / 16

12x12 Shed Plans and Building Guide

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

6x6 Shed Plans and Building Guide

Chapter 7 - Porch Framing

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

Attached/Detached Patio Cover

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA


ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

Gambrel Barn with Overhang Manual

Trusted ICC ES PASLODE, Evaluation. report, or as to any. ICC-ES Evaluation

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Belmont with pocket doors. Building Size 12'x16' or 12'x20' Revised January 10, 2012

Carpentry/Carpenter CIP Task Grid

Deck Design Guide. One and Two Family Residential Dwellings

BUILDING PLANS. BUILDING DEPARTMENT

ROOF-CEILING CONSTRUCTION

Material List for Log Complete Packages

Connections in CLT Assemblies

City of Virginia Beach, Virginia Typical Deck Details

Wood Connections. Concepts of Well Designed Connections

The better way to build TM. Installation Manual ROOF SIPs

3 DATE ISSUE R# Forefront Dermatology. CONFLUENCE DESIGN GROUP #2 Daniel Drive O'Fallon, MO ph: St. Peters, Missouri 63376

Accessory Dwelling Unit Prototype 4 Plan Sets. Prototype 4: Detached 1- Story ADU using alternate materials and techniques

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Unit 9. Wall and Ceiling Framing

Typical Deck Details

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

HOME STRENGTHENING GUIDE HOW TO ECONOMICALLY STRENGTHEN YOUR HOUSE AGAINST EARTHQUAKES AND HURRICANES

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

The Base Shear Formula

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

Classic Connection Conundrums

ROOF-CEILING CONSTRUCTION

SECTION ROUGH CARPENTRY

SDWH TIMBER-HEX Screw

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

Deck Evaluation Checklist

Wall and Ceiling Framing

Transcription:

ANCHOR BOLT CORNER LOCATION 1-2x4 or 1-2x6=4 1/4" 1-3/4 or 1-3x6=5 1/4" 2-2x4 or 2-2x6=5 3/4",------------2-3x4 or 2-3x6=7 3/4" 1-4x6 or 1-6x6=8 1/4" 1-4x8 or 1-6x8=1 A" 1-4x10 or 1-6x10=12" I ------1er----- '----_Compression Post

r-- 41/4" 1-2x4 or 1-2x6 / 5 1/4" 1-3x4 or 1-3x6 /1 1 53 / 4 " 2-2x4 or 2-2x6 / 7 3/4" 2-3x4 or 2-3x6 /1 t-- 81/4" 1-4x6 or 1-6x6 ~/ 10" 1-4xB or 1-6xB +--12" 1-4x10 or 1-6x10 2 3/4" Typ. / / / Compression Post 6" Max --~ ANCHOR BOLT Mid-Wall Location

1-2x4 or 1-2x6=4 1/4" 1-3/4 or 1-3x6=5 1/4" 2-2x4 or 2-2x6=5 3/4" 2-3x4 or 2-3x6=7 3/4" 1-4x6 or 1-6x6=8 1/4" 1-4x8 or 1-6x8=10" 1-4x10 or 1-6x1 0=12" ANCHOR BOLT Perpendicular-To-Wall Location

TOP PLATES ~-SPLICE PER SCHED TIE @48" ~ BN SN TO BLKG 4" MAX I "~-- ------" 2x BLKG _-----l '--------HGR '--------2x LEDGER WI -------'--'----J'------'----- Ballooned Framed Shear Wall W/Ledger

TIE @ 48" TOP PLATES ~-----=~~... SPLICE PER SCHED BN I SN TO BLKG //~BN TO BLKG 4" MAX -",,-- I-+t-?r-- 1'- MIN------+ft- 2x BLKG 2x LEDGER WI ~/ 2x BLKG @ 48" JST PER PLAN Ballooned Framed Shear Wall W/Ledger

1 1/8" Maximum Hole Bearing plate at double top plate No splice in the top plate permitted within 8" of the rod. ATS-3 1 1 1 1-1----

~-NUMBER OF HOLD DOWNS PER PLAN AB PER SHEAR WALL SCHED PLAN VIEW MARK ANCHOR LGTH POST (ON) PERMFR PER MFR PER MFR X 4x 4x Bolted Hold down & Schedule

cc. WALL & FTG FULL HGT-- OF HOLD DOWN POST ~ HOLD DOWN POST (FULL HGT) r--- HOLD DOWN PER PLAN INSTALL PER MFR -" & GERAL NOTES ~ ~ 7 MB Dia Min. k--'=~;f:=='s;==~i!iii----- 1/2" Min. HOLD DOWN ANCHOR li- P III III ==,~ Note: 1/2" Min. above the plate to allow for pretensioning the anchor to minimize the connector slip. Bolted Hold down

1 1 1 Cf. OF POST 7 MB DIAMIN JOISTS-- ~_FULLD BEARING _I BEAM / POST ~ ------'-----,~'~ Column Cap (Strap)-Beam to Beam

Starter Shaped Blocking FA anel (Roof '-----_Diaphragm, Roof Sheathing) Joist/Rafters Fascia Soffit """~_ /, Top Plates SN ~ 16' 4 /1111"--_--, ~-- Studs _---Plate ~- Panel or Floor Panel ---~~~~====::1~======r_----rtoor--,:; BN ~ Blocking _ LEGD -~~_.. ~:'::::::J Shear Wall Panel Floor Joist =Panel Edge Nailing BN =Panel Boundry Nailing SN =Shear Nailing FA = Framing Anchor Shear Wall Length Er> =Shear Wall Mark Anchor bolt ~Plate (Sill plate, foundation plate) / / _Slab on Grade ~.II~~t=~~~------,,~~~-~- <l <l Footing I 11111 111 <l <l 'J 'J 'J III 111-; 111== ~ <l >J"~>I 111== 'J <l EXAMPLE OF TIMBER TERMS

r-+-_sn BN Insulation Per Local Code Req. V 2x BLKG OR 2xRIMJST '-------Sub-Floor I ~ «w @) z ~ Co Stem Wall Per Local Code Req. Rebar Per Local Code or Req. / '1 'J'J II -- II "Q II '1 II II 'J'1 1 1 I '1 'J II --~ I JI'1~ 'J _ ~ "1-1 Mud Sill JOIST z ~ Co -'... Footing Per Local Code Req. Exterior Footing W/Crawlspace

STUDS PER PLAN c-----l---_sn PLATE FA Installed Per MFG Inst. BN_~ BN TO BLKG ~ 2x BLKG @ 48" ~----+-t++\-i+----- 2x BLKG OR ji GIRDER & HGR 2x RIM JST ~~w-~~=----~-----'----------j ~_Per Plan (Full width PLATE @ HGR) STEM WALL Per Local Req. Footing Per Local Code Req. II Z',II 1'1 II / -- 'Q II II Z', 17 Z', 'Q II 'I I~-l------- ----------''t: II 1 II I----+-~ I Z',;Q 'I I ~-~~----~ 111 111 I I III=- '~-IIII 11-111- -'- Rebar Per Code Req. z :2: Exterior Footing W/Crawlspace

BN SN STUDS PER PLAN ~~ ~-FA AS REQD r----_2x BLKG @ 48" BN TO BLKG,-------- 2x RI M JST _~ TOP PLATES SPLICES PER ~ SCHED STUDS PER PLAN ~ PLATE ~~ 0" @ 2x 1/2" @ 3x 1" @ 4x,I II-II( 1- I++-----+-------ft-4fflrt------;f-t- 111-111 111. I I.III=- -'- <i Exterior Footing W/Cripple wall

- \ STUDS PER PLAN ~~'.'.'.'.'.'...~~~ ~ FAASREQD / ~ ~ 2x BLKG _LI----------~I ~---_. <H=~~<:::: />< 1/ '\ TOP PLATES ~//I~ ~~ /~/ ~ /~ STUDS PER PLAN /"- ~ ~-=i~ ~ PLATE / f-----------j( I~ [/! ~ ~ / "...' / '.. ~/ "~I" " / ~ ~ <I 6" z I" ~ 0" @ 2x 1/2" @ 3x 1" @ 4x STEM WALL/// PER LOCAL CODE <I j Exterior Footing W/Cripple Wall

2"MAX r-- STUDS PER PLAN O"@2x 1/2"@3x 1"@4x, PLATE, AB & PLATE WASHER PER SCHED r-- SLAB & BASE COURSE PER PLAN 6" MIN @EARTH ~ ~ " ~ " " '7 ~~='LLEL'L"--'-LC' -'--'JL"'1,,~ 1_-1I-II I~-II-II IIT' '-----= I I ' ~ Note: The 1/2" min. distance specified for the 3X plates from the concrete to bottom of the panel provides some moisture protection for the panel. Prevents dry rot. I I I -III I '-----= I I ' Exterior Footing

Exterior Shear Wall W/Blocking ~STUDS PER PLAN PLATE SN - ~2x BLKG WI FA PER SCHED JOIST BN TOP PLATES '---------SPLICES PER SCHED

~_STUDS PER PLAN SN BN 'I' JOIST BLOCKING OR LAMINATED BLOCKING W/FA PER -~ CODE ~ PLATE -~,k----l-=----=-------- \ 'I' JOIST WI STIFF PER MFR Exterior Shear Wall WII-Joists

STUDS PER PLAN ~- SN ------, BN I r----plate 'I' JOIST BLKG OR r---laminated BLKG WIFA PER CODE / / / 'I' JOIST WI STIFF PER MFR Interior Shear Wall W/I-Joist

STUDS PER PLAN r----plate SN~ ~_2x BLKG @ 48" BN TO BLKG BN ~ MIN JOIST 2x RIM JST W/FA PER CODE REQD TOP PLATES,--SPLICES PER PLAN Interior Shear Wall W/Rim Joist

SN BN MATCH WALL BELOW 4" MAX 4" MAX BRACE ~PER PLAN -~ FA PER SCHED ~TOPPLATES SPLICE PER TRUSS Gable End Truss Over Shear Wall

V' / SN / / / -/ 1"- f ~ vir ~ --- BN ------*I" FA AS REQD! \ 0" @ 2x 1/2" @ 3x 1" @ 4x ~~~~~~<I,111-111111-111111-1111 STEM 11=111- VVALL ~ 'I zs Interior Footing VV/CrawlSpace & Cripple VVall

BN -+-------- SN r-- ~_STUDS PER PLAN PLATE (Sill) FA Installed Per MFG Instructions '-------_2x BLKG 4-16d@JSTLAP ~~_JOIST STEM WALL Per Code ~~ Req.,-----PLATE co _I T""" Footing Per Code Req. Rebar Per ~~-Code Req. Interior Footing W/Crawlspace

-~:I~ STUDS PER PLAN BN PLATE FAPERSCHED 2x BLKG @ 48" BN TO BLKG 2xRIMJST _~ STRAP PER PLAN ~~/~Girder & HGR Per Plan 1\1 (Full Width Plate @ f----~~-----==l!======li======!#=~~===~=jf'l~ :lr-hgr) PLATE (Sill) EQUAL STEM WALL Per Code Req.,III-II(1-111111-111-'- I I III=- Footing Per Code Req.,I II-II( 1-111 111-111 -'- I I III=- Rebar Per Code Req. Interior Footing W/Crawl space

-~~- 1,.--------------/ / ~ I~ /I"----~ ~--J/ ~- STUDS PER PLAN 4-16d @ JST LAP 0" @ 2x 1/2" @ 3x 1" @ 4x / ~ ~ ---~ _ /Z\ STUDS PER PLAN TOP PLATES ~ //!I~~~ r- SPLICE PER / I, ~ / SCHD I~ /I~ ~V~~~ )~~PLATE / f= 1"-- ~ ( = C= ~ /~ ~ _ /.1-------- ~ ~ 1- \~~ " ~~ I'",I II-II( 1-111 111 I I III=- STEM WALL ~ 111- -'- Interior Footing W/Cripple Wall

2"MAX ---STUDS PER PLAN O"@2x 1/2"@3x 1"@4x ---PLATE, AB & PLATE WASHER PER SCHED SLAB & BASE COURSE ---PER PLAN 1 1_-II"~-IIII II~ I ------= I 1 ' Interior Footing

SN -- BN ~, -, ~_STUDS PER PLAN 7 / PLATE 2x SOLID BLKG =1] JOIST ------" ~"'" TOP PLATES ~SPLICEPER SCHED Interior Party Shear Wall W/Blocking

~_STUDS PER PLAN SN - BN SN \~~ / / I 2x BLKG @ 48" BN TO BLKG 1'- MIN JOIST -_/ 2-2x RIM JSTS WI FA PER SCHED TOP PLATES '-----_SPLiCE PER CODE Interior Party Shear Wall W/Rim Joists

STUDS PER PLAN SN PLATE / JOIST 2x BLKG Interior Shear Wall Above

r---bn JOIST ~4-16d @ JST LAP \ \ 2x BLKG WI FA PER CODE TOP PLATES '--------SPLICES PER SCHED Interior Shear Wall Below W/Blocking

r-----2x BLKG @ 48" BN r----- TO BLKG 1'-0" JOIST 2x BLKG W/FA PER CODE TOP PLATES '------SPLICE PER SCHED Interior Shear Wall Below W/Rim Joist

BN 2x VERT ES OF TRUSS TRUSS TOP I\/~------t----CHORD BN SHAPED BLKG TRUSS I-I-----+---+----VERT MATCH WALL A BELOW / ~ X TRUSS BOT CHORD SECTION X-X \ TOP PLATES SPLICE PER SCHED Interior Shear Wall Perpendicular To Trusses

STUDS PER PLAN SN BN~ \ \ ~PLATE 4-16d @ JST LAP JOIST 2x BLKG WI FA AS REQD TOP PLATES \-SPLICES PER SCHED Interior Shear Wall W/Blocking

r----studs PER PLAN SN --, BN \ PLATE TOP PLATES r----splice PER SCHED '-'I' JOIST WI STIFF PER MFR '--------BLKG Interior Shear Wall W/I-Joist

~-STUDS PER PLAN SN ------, BN \ \ I ~PLATE 'I' JOIST BLKG OR r---laminated BLKG WIFA PER CODE 'I' JOIST WI STIFF PER MFR Interior Shear Wall W/I-Joist

STUDS PER PLAN r---_plate SN~ ~_2x BLKG @ 48" BN TO BLKG BN ~ MIN JOIST 2x RIM JST W/FA PER CODE REQD TOP PLATES ~-SPLICES PER PLAN Interior Shear Wall W/Rim Joist

2xSHAPED BLKG BN FA PER SCHED TOP PLATES SPLICE PER SCHED Joist At Bearing Wall

BN ~ BN Toenail ---, \FA as Required ~ Load Path--Exterior Floor/Roof Framing

BN ~ BN ~ ~ Blocking \j Load Path--Exterior Floor/Roof Framing

,_-+-_SN BN SN r- SN - '---- BN \ FA as Required For Shear transfer -----" Where a double sill plate is used the sill shear nailing of both the upper &lower plates are frequently missed. Penetration of the nail from the lower plate thru the panel & into the blocking should be checked. FA as Required For Shear transfer A Load Path--Exterior Floor/Roof Framing \j B

Cont. Panel -- /, Fire Blocking \~/ '-----_Ceiling Joist Used in dropped ceilings for kitchens or bathrooms. Wall panel is normally installed after all walls & joists are in place. Load path is often broken at the ceiling joist. Leaving a space for the installation of the panel is the correct solution. Load Path--Interior Wall W/Ceiling Joist

Blocking, \: ~ ~- -~ Fire Blocking This wall panel is normally installed after all walls &joist are in place. Found or used in kitchen & bathrooms with dropped ceilings. Load Path--Interior Wall W/Ceiling Joist

\ Missing nails (shiners or air nails) must be corrected. One line of missing nailing can greatly reduce the diaphram's capacity to resist loads. Excessive slanting of nails will adversely affect the lateral capacity of the shear walls. -- -- / LOAD--Path Nailing

<C. WALL & FTG FULL HGT / OF HOLD DOWN ~ / POST ~~ ~--HOLD DOWN POST (FULL HGT) HOLD DOWN PER PLAN I //-------;NSTALL PER MFR >F-+-+- / &GERAL NOTES ~ ~~+=======~-- 1/2" Min. HOLD DOWN ANCHOR Nailed/Screwed Hold down

BN 2x RIM JSTW/ FA PER SCHED TO BLKG ~---rr--- 2x BLKG @ 48" /,,~... MATCH WALL BELOW " ~2x4 STUDS @ 16" '-------BRACE PER PLAN ~----++---- SN Platform Framed Party Shear Wall W/Attic Rake

2x RIM JOIST BN BN TO BLKG \ JOIST PER PLAN ~ 2x BLKG ONE BAY @48" _----.-J ~TOPPLATES SPLICE PER SCHED 3x BLKG Rim Joist At Shear Wall

MARK (1 ) (2) FOUNDATION PLATE JOINT FA NUMBER OF FA'S AB STUDS ON CONC SN SPACING PER BLOCK ON WOOD (EDGE NAILING) (FOUNDATION PLATE) &BLKG OR MAS (SHEAR NAILING) RIM BLKG BLKG ANCHOR BOLTS) JOIST @16" @24" ~ 10d @6" 5/8" DIA @ 48" 3x 2x 3x 16d @6" 24" 1 1 ~ 10d @4" 5/8" DIA @ 24" 3x 2x 3x 16d @4" 12" 2 2 B> 10d @3" 5/8" DIA@ 16" 3x 2x 3x 16d @3" 12" 2 3 (1) cf]; WOOO MIN LGTH (WIDTH) OF SHEAR WALL (FT) STRUCTURAL PANEL MARK (NAIL SPACING) (2) PROVIDE PLATE WASHERS 1/4 x 2112 x 0'-21/2" TYP.

BN - 4"MAX MATCH WALL BELOW '-------BRACE PER PLAN FAPERSCHED '----- TOP PLATES '--SPLICE PER SCHED ---'---'-------j\-------,------- Platform Framed Party Shear Wall W/Trusses

EQUAL ct. OF STRAP EQUAL 1/ 1/ 1/ / / / JOISTS \ / FULL D BEARING v I~.. X/.. /... /.. /.. /.. /... /..\ X... /.. /.. /.. /..//.. /... V IX./.. /.. /.. /... /.. /.. /.. /.. / X ~ v 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 J BEAM / \ STRAP PER PLAN POST ~ Strap-Beam To Beam

EQUAL i OF STRAP EQUAL / 1/ / / / 1/ JOISTS,--FULL D BEARING -'\ / /_STRAP PER PLAN 1.. 1.. /..//.. / X/ 0 0 0 0 0 0 0 /../../../../../..\ X../../ / V// IX //../ / / / / / IX // /1<> ~ "----0 o =_ 0 --:- 0 ~ ~ ~ o =_ 0 --:- 0 ~o o~ 0 ~ +- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o~ 0 0 ~ 0 0 \ \ \ TOP PLATES o BEAM_/ POST ~~-------'---_, ~'--'------'---_ Strap-Beam To Top Plates

'f. OF STRAP 1/ / EQUAL I. EQUAL / 1/ / BEAM \ / / STRAP PER PLAN DBl STUD TYP ~-~ ON PLAN /: vv\~ '------TOP PLATES Strap-Beam To Top Plates

JOIST PER PLAN W/"U" HGR TYP ~- BN --STRAP PER PLAN SHAPED RIDGE BM PER PLAN Tie At Ridge Beam

~BN ~ == == == == ---,---If-------_ 4" MAXi _//,--------BRACE PER PLAN MATCH WALL BELOW ~-FA PER CODE 4" MAX ----I ---I -------Y TOP PLATES ~-SPLICE PER SCHED Truss Over Shear Wall

BN 2x SHAPED BLKG t TRUSS PER PLAN FA PER CODE TOP PLATES '---SPLICE PER SCHED Trusses At Bearing Wall

- - - -- I _ BLOCKING ON PLAN I _ BN STGR @ CONT PANEL EDGES (WHERE BLKG REQD) '-----_FN @ 12" BN STGR NOTES: 1. FOR ITEMS NOT NOTED SEE PLANS. 2. MINIMUM PANEL DIMSION IS 2'-0". Typical Blocked Roof & Floor Diaphrams

2x SCAB PLATE W/ 4-16d EA D PLATE, AB W/ PLATE WASHERS 1/4 x 2 1/2 x 0'-2 1/2" PER PLAN / DETAILS 5" MIN Note: Holes for anchor bolts shall be 1/32" to 1/16" larger than anchor bolt diameter. If holes are over size repair with epoxy. 5" MIN... ;PLAN STUDS PER TOP OF SLAB 7" MIN INTO CONC (WHERE CURB OCCURS ADDL LGTH EQUAL TO CURB HT) 12" MAX 12" MAX z ~ ~ ~ k--++i IT] >-"k- --------+ 2" MAX / AT CORNER AT INTERSECTION Typical Plate Anchor Bolts AT SPLICE

TOP PLATES -----, @JOINT r----(stagger) HOLD DOWN POST PER PLAN J--\---+-I JOINT STUD PER SHEAR WALL SCHED 1/2" MIN EDGE I~-----DISTANCE TYP ~_~ HOLD DOWN ANCHOR PER PLAN _ STUD PER '-------PLAN ~FN Typical Shearwall Elevation @PLATE '-----(STAGGER) NOTES: 1) FOR ITEMS NOT NOTED SEE PLAN & SHEAR WALL SCHED. 2) MINIMUM PANEL DIMSION IS 1'-0". 3) USE FULL SIZE PANELS WHERE POSSIBLE. 4) FIELD NAILING (FN) @ 12" ON. 5) 3x SOLID BLKG @ HORIZ JOINTS.

---@. ~1>.t " SN - [] ---@ ---@ [] [] SN_/ (si [;:1> I-l \_:: ~ ---@ ---@ ---0 Typical Shear Wall Intersection (No Hold downs)

SN []> ---0 ---------j@ SN ---@ ------{@ o {~ ---@ ---------j0 ---@ Typical Shear Wall Intersections (With Hold downs)

NOTES: /----~-~~-~~~\~ /\ ~ /\ \ ~ \ \ \ " ( \ \ \ ~" I \ \ \ I \ \ \ I \ \ \ \ f I I \ \ \ \ 1\ \ \ \ I \ \ \ \ 1 \ \ \ \ \.. \ 1 \ ~ \ \ I \ " \ \. ~. ~ \ ~\ \ ~ V 1 ~ \ ~ \/ I I " " \ " \..... \ " / 1. FOR ITEMS NOT NOTED SEE PLANS. 2. MINIMUM PANEL DIMSION IS 2'-0". Typical Unblocked Rood & Floor \ / I \ ------ BN STGR FN @ 12" Ef-----------..-----------.._-~~3

NOTE NOTE NOTE 0 NOTE @ OR BN PER PLAN ~t-- NOTE (] PANEL OR BN PER PLAN NOTE CD NOTE 0 NOTE G) CLEARANCES PER PANEL MFR 1/2" MIN PANEL EDGE DISTANCE 3/8" MIN LUMBER EDGE DISTANCE STUD OR JOIST FRAMING I - JOIST FRAMING