VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters

Similar documents
IEC Electrical fast transient / Burst immunity test

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Insulation Test System

MILITARY & AEROSPACE TESTING

Avionics Test System. Lightning Tests

Insulation Test System

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

XY-Capacitor Surge Test (IEC )

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

Combination Wave Test System

Low Frequency Measuring System

Electricity Meter Test System

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Regulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany

TK 100 Probe Calibrator. Instruction Manual

Specification. CTR 2 ESD calibration target

Telecom Test System. Lightning Tests

LS200 TEST DATA IEC61000 SERIES

Conducted Immunity Testing

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

ESD Test System. Immunity Tests

PML 711A-RO High impedance passive probe Features:

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

Vectron International Filter specification TFS246R 1/5

Electrical Specifications. Maximum Maximum Resistance Working Overload Temperature. Mechanical Specifications

SAW Bandpass Filter F2G12

Surge Generator for MIL-STD 1275

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

50W Constant Current (700mA) Dimming LED Driver

TETRIS User's Guide. High Impedance Active Probe DO177-1

Novità sulla IEC ; -10; -12

VI TELEFILTER Filter specification TFS 130C 1/5

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

Advanced Test Equipment Rentals ATEC (2832)

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Model 310H Fast 800V Pulse Generator

9 Specifications. Specifications NOMINAL CHARACTERISTICS

CS114 + CS115 + CS116

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Switching Regulator. LMT78_1.0R Series Wide input, non-isolated & regulated, single output, SMD package

VI TELEFILTER Filter specification TFS 248F 1/5

SCXI MHz Quad 8x1 50 Ω Multiplexer

In particular, the filter module is compliant with the following requirements of MIL-STD-461C/D/E standards :

NI PXI-2555 Specifications

Output Voltage* (nom.)(adjustable)

Professional Leaded Resistors

EMC Test Facility Sale

Product Specification sheet

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Metal Film Precision Resistor. Features

Metal Film Precision Resistor. Features

Digital Clamp Meter Model: &

Fast transient burst simulator

SPECIFICATIONS. Metal Film Precision Resistor. CSR-Serie SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

MTC Series 15 W AC/DC Switching Power Supply Module Medical

Vectron International Filter specification TFS1220 1/5

TA MHz oscilloscope probe TA MHz oscilloscope probe

Vectron International Filter specification TFS 125P 1/5

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

75W Constant Current (700mA) LED Driver

400 MHz Passive High-Voltage Probe R&S RT-ZH

Datasheet. IC50X, 250 W Single-Output 600 Vin 750 Vin. Rev00

Vectron International Temperatur sensor specification TFSS434B 1/6

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

RF Conducted Immunity and Automotive Transient Generator Test Systems

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

VI TELEFILTER Filter Specification TFS 211 C 1/5

HEC-30/35LTA-33TDAA Rev A

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

NI PXIe-5630 Specifications

HEC-35LTA-XXTSAA Rev A

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Series AM50E-NZ 50 Watt DC-DC Converter

Appendix A: Specifications

Vectron International Filter specification TFS 121 1/5

SAW Bandpass Filter F4521

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

R&S ZV-Z5x Calibration Units Specifications

DECLARATION OF CONFORMITY

Experiment #7: Designing and Measuring a Common-Emitter Amplifier

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

Technical Specification

Arbitrary/Function Waveform Generators 4075B Series

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Thin Film Rectangular Chip Resistors

Low Frequency Measuring System

MAX. OUTPUT POWER 24/48/72/96/110 VDC 5 VDC 6 A 30 W 82% 0RQB-30Y05L. 0 R QB - 30 Y 05 L y. Output Power. Input Range

Immunity Testing for the CE Mark

NI SCXI Specifications

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

CTR2 / CTR2-AD CALIBRATION TARGET AND VERIFICATION ADAPTER FOR ESD

DATASHEET SMT172. Features and Highlights. Application. Introduction

Transcription:

VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters Revised: 21.December 2010 1 General Information To oscilloscope VERI50 EFT To generator 1.1 Technical data Input impedance 50 Ohm ± 2% Maximum power dissipation 1000 spikes per seconds at 4400 V Nominal ratio DSO input 1 MOhm DSO input 50 Ohm ratio 1:500 54dB ratio 1:1000 60dB Standard IEC/EN 61000-4-4 For further information see Verification Protocol. 2 Application of the VERI50 EFT: The test generator characteristics shall be verified in order to establish a common reference for all generators. For this purpose, the following procedure shall be undertaken. The test generator output shall be connected to a 50 Ω and 1 000 Ω coaxial termination respectively and the voltage monitored with an oscilloscope. The 3 db bandwidth of the measuring equipment and the test load impedance shall be at least 400 MHz. The rise time, impulse duration and repetition rate of the impulses within one burst shall be monitored as well as the burst duration and burst period. For each of the set voltages of Table 2, measure the output voltage at a 50 Ω load - Vp(50 Ω). This measured voltage shall be [0.5 x Vp(open circuit)] ± 10%. Table 2 Output voltage peak values and repetition rates Set voltage Vp (open circuit) Vp (1 000 Ω) Vp (50 Ω) Repetition frequency khz 0,25 0,25 0,24 0,125 5 or 100 0,5 0,5 0,48 0,25 5 or 100 1 1 0,95 0,5 5 or 100 2 2 1,9 1 5 or 100 4 4 3,8 2 5 or 100 NOTE With the 50 Ω load, the measured output voltage is 0,5 times the value of the unloaded voltage as reflected in the table above. 21.12.2010 E-VERI50 EFT-E-IN 1/6

2.1 Application of the VERI50 EFT for TRA calibration: Electric diagram of the calibration set up VER50 EFT TRA1000/2000 generator with 50 Ohm source impedance DSO measurement equipment bandwidth min 400MHz, input impedance 50 Ohm The voltage ratio of the VERI50 EFT can be calculated as follow: Vout = Vch x 0.5 (explanation see page 1/4 of the instruction sheet or see IEC 61000-4-4 Ed.2) n = ratio = Vout / Vm. The Vout and Vm values can be found in the calibration report of the VERI50 EFT. On the type plate of the VRI50 EFT a ratio of 1:500 is indicated (DSO input 1 MOhm) The explanation can be given as follow: The calibration is made with 50 Ohm input impedance of the CRO. The input impedance 50 Ohm of the DSO together with the R5 divide the voltage signal by a factor 2. The real ratio of the VERI50 EFT is therefore the half value 1:1000 as indicated on the type plate. The value on the type plate must be used when the DSO input impedance is 1MOhm. When the input impedance of the DSO is 50 Ohm the ratio 1:500 must be used. The accuracy of the ratio is calculated by resistor +/- 1 % The ratio is checked with two methods: Step generator and the Networkanalyser with an accuracy of +/- 2%. With the step voltage generator >850V the time response and the voltage influence are checked. With the Networkanalyser the frequency response is measured. The VERI1k is o.k. when both calibration are within +/- 2%. db = 20 log Vout/Vm The plot shows 60 db The ratio calculation results in n = 10 60/20 = 1000 as indicated on the type plate. 21.12.2010 E-VERI50 EFT-E-IN 2/6

Type tests results damping factor in function of frequency The 4 Marker indicate the following: Marker 1: 1 MHz nominal. The ratio calculation results in n = 10 60.119/20 = 1013 Marker 2: 70 MHz corresponds to rise time at the lower tolerances 6.5ns. The ratio calculation results n = 10 60.112/20 = 1012. Deviation 1.2% Marker 3: 100 MHz corresponds to rise time at the highest tolerances 3.5 ns. The ratio calculation results n = 10 60.071/20 = 1008. Deviation less than 1% Marker 4: 400 MHz check to +/-3dB point as specified in the IEC 61000-4-4 Ed.2 21.12.2010 E-VERI50 EFT-E-IN 3/6

3 Standard accessory, dimensions 3.1 Included articles, dimensions 21.12.2010 E-VERI50 EFT-E-IN 4/6

4 Recycling / Disposal 4.1 RoHS directive 2002/95/EG The VERI50 EFT complies with the directive 2002/95/EG (RoHS - Restriction of certain Hazardous Substances). From December 2005, all EMC Partner products either hand soldered or by machine are produced using lead-free solder. 4.2 WEEE directive 2002/96/EG The EMC Partner VERI50 EFT, is exempted from the directive 2002/96/EG (WEEE) under category 9. The product should be recycled through a professional organisation with appropriate experience for the disposal and recycling of electronic products. EMC Partner are also available to help with questions relating to the recycling of this product. 4.3 Information for dismantling Remove always power cord fist. There is no special danger involved in dismantling the VERI50 EFT. 4.4 Parts which can be recycled The VERI50 EFT contains parts made from steel, aluminium, PVC, two-component sealing compound. The impulse capacitors are filled with non-poisonous mineral oil. The various parts can be separated and recycled. 4.5 Parts which can not be recycled All parts in the VERI50 EFT can be recycled. 21.12.2010 E-VERI50 EFT-E-IN 5/6

5 Service Information EMC PARTNER AG Baselstrasse 160 CH - 4242 Laufen Switzerland ++41 61 775 20 50 ++41 61 775 20 59 service@emc-partner.ch www.emc-partner.com 21.12.2010 E-VERI50 EFT-E-IN 6/6