PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :
|
|
- Caitlin Randall
- 6 years ago
- Views:
Transcription
1 Section : 0 Document : DQM-01 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Section I(B)-Technical Specification Tender Enquery No PUR/UARC-02/14-15 Name of the Equipment: Damped Oscillatory ring wave Generator Name Of Vendor Offer Number and Date PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. : FORMAT NO.:PUR/TENDDOC/P6/06 CPRI Page No. : 6 OF 21 Issued by : Q A Sl.No. Parameters CPRI Specification/Requirements for Damped Oscillatory and Ring Wave Generator 1 Scope Supply, Installation, Commissioning and Training of Damped Oscillatory and Ring wave Generator. 2 Purpose of use To verify the Immunity of Electrical & Electronic products (Single phase & Three phase Delta and Star configuration) for Damped oscillations and Ring wave according to latest EN/IEC , EN/IEC , EN/IEC & IEC standards. To be completed by the Bidder Guaranteed Technical Particulars(GTP) Deviation/ Remarks Specify if any
2 3 Application The equipment shall be suitable for testing Equipment Under Test (EUT) with Star and Delta configuration. The application areas are: Power sector, Industrial, Medical, Residential, Telecoms etc. 4 Damped Oscillatory wave generator shall consists of following: (1) Generator (2) Coupling Decoupling Networks (CDN s) (3) Magnetic field coil The following specifications are Minimum and bidder shall provide suitable Generator, CDN s & Magnetic field coil with appropriate values so as to meet the overall test system requirements as per latest EN/IEC , EN/IEC & IEC standards. I. Slow Damped Oscillatory Wave as per latest EN/IEC : Generator Specification: Peak open circuit voltage range: 250V to 3,000V ±10% or better; Indicate other ranges and shall be quoted separately as an option. Voltage Rise time (first peak): 75ns±20% or better Voltage oscillation frequency: 100kHz and 1MHz ±10% or better Decaying: Peak5 must be > 50% of the peak1 value and peak10 must be < 50% of the peak1 value.
3 Short circuit current (Peak 1 value): 1.25A to 12.5A ±20% Output/Source impedance: 200 ohm ±20% or better Polarity of first half-period: Positive & negative selectable Repetition rate: At least 40 transients/s for 100kHz ±10% and 400 transients/s for 1MHz ±10% Burst duration: not less than 2s Release of pulses: Automatic & manual. Test duration: provision for selecting 2s (+10%, -0%) and continuous duration shall be provided. Display of test parameters: LCD/on software or any suitable display. Output: Direct via HV safety connectors. CRO trigger: Trigger signal for oscilloscope shall be provided. Suitable cable/ probe shall be provided. Coupling mode: Line to Line; Line (s) to ground (PE). Test level: shall meet the requirement of latest EN/IEC Waveform: The waveform of damped oscillatory wave with peak points shall comply with latest EN/IEC Verification of the characteristics of the generator: Shall comply with all the requirements as per latest EN/IEC The generator characteristics shall be verified from an accredited lab compliant to ISO/IEC standard and certificate with data shall be provided. The certificate shall be in name of CPRI.
4 II. Coupling Decoupling network (CDN) for AC/DC power supply ports (Built in or external) : Suitable CDN shall be provided for damped oscillatory generator. (a) The CDN shall comply with all requirements of latest EN/IEC for shielded and unshielded lines. Supply voltage rating/current rating: AC: 440V/32A per phase (3 Phase), 50/60 Hz; Quote for 690V (L L)/32A per phase separately as an option. Indicate other higher ratings and shall be quoted separately as an option. DC: 250V/20A per line; Indicate other higher ratings and shall be quoted separately as an option. (b) The CDN shall comply with all requirements of latest IEC and EN/IEC for shielded and unshielded lines. The coupler shall offer capability to test up to 4 pairs / 8 lines. Supply voltage rating/current rating: AC: 250V/4A per phase (3 Phase), 50/60 Hz; Indicate other higher ratings and shall be quoted separately as an option. DC: 250V/4A per line; Indicate other higher ratings and shall be quoted separately as an option. Coupling mode: 4 (L1, L2, L3 & L4) + PE; Line to line or
5 Indications: To indicate selected coupling mode and lines to be tested. Remote/manual controlled via Damped oscillatory wave generator. Waveform verification at the CDN output: The waveform and characteristics requirements detailed in latest EN/IEC shall be met for all coupling modes. The waveform characteristics shall be verified from an accredited lab compliant to ISO/IEC standard and certificate with data shall be provided. The certificate shall be in name of CPRI. All required verification kit for calibration/verification shall be provided.
6 III. Coupling/Decoupling network (CDN) for Signal/data lines: Suitable CDN for at least 4 signal / data lines shall be provided for damped oscillatory generator. The CDN shall comply with all requirements of latest EN/IEC for shielded and unshielded lines. Voltage rating/current rating: AC: 250V/4A per phase, 50/60 Hz; Indicate other higher ratings and shall be quoted separately as an option. DC: 250V/4A per line; Indicate other higher ratings and shall be quoted separately as an option. Output EUT terminal: At least 4mm dia. connector of suitable rating shall be provided. CDN shall be compatible with commonly available communication interfaces. Indicate the communication interfaces the CDN supports. Coupling modes as per latest EN/IEC Remote/manual controlled via Damped oscillatory wave generator. Indications: To indicate selected coupling mode and lines to be tested. Quote separately for Coupling/Decoupling network (8 signal/data lines). Waveform verification at the CDN output:
7 IV. Magnetic field coil for Damped Oscillatory wave complying to EN/IEC standard: The Magnetic coil suitable for testing table top equipment, floor standing equipment and larger EUT s complying to latest EN/IEC shall be provided. Dimension: 1x 1 m minimum; Quote for 1x2.6m separately as an option. Indicate other dimension and shall be quoted separately. Max. Damped oscillatory wave magnetic field: up to 100 A/m or better Output current range: from 10A to 100A, divided by the coil factor. Note : The output current range for the standard coil is from 12A to 120A. Frequency: 100 khz & 1 MHz ±10% Polarity: Positive & Negative Synchronisation angle: 0 to 360 deg. Induction coil current waveform: shall comply with the requirements of latest EN/IEC Test duration setting: 2s and continuous The magnetic field coil shall be adjustable in height and allow for 360 rotation. Shall allow easy moving of the coil. Suitable stand shall be provided. Suitable current source for the magnetic coil shall be provided. The magnetic coil shall be directly connected to the corresponding HV output of Damped oscillatory wave
8 5 Ring wave generator shall consists of following: (1) Generator (2) Coupling Decoupling Networks (CDN's) The following specifications are Minimum and bidder shall provide suitable Generator with appropriate values so as to meet the overall test system requirements as per latest EN/IEC standard. The Ring wave generator shall be built in along with Damped oscillatory wave generator or shall be an independent device. General Specification: Open circuit voltage (Pk1 value): 250V - 6,000V ± 10% or better; Indicate other ranges and shall be quoted separately. Voltage Rise time: 0.5µs ± 30% or better Current Rise time: 1µs (short circuit condition) Voltage oscillation frequency:100 khz ± 10% or better Decaying: 0.4<Ratio of Pk2 to Pk1< <Ratio of Pk3 to Pk2< <Ratio of Pk4 to Pk3<0.8 Output impedance: 12 ohm & 30 ohm (switchable) ± 20% or better Short circuit current (Pk1 value): 500A ± 10% for 12 ohm generator setting; 200A ± 10% for 30 ohm generator setting;
9 Polarity of the first half-period: Positive & negative selectable. Repetition rate: 1 to 60 transients per minute Release of pulses: Automatic & manual. Phase relationship with power supply: synchronizable from 0 to 360, resolution 1, tolerance ±10 or better. Display of test parameters: Peak voltage, peak current etc in LCD/software or any suitable display. Output: Direct via HV safety connectors. CRO trigger: Trigger signal for oscilloscope shall be provided. Suitable cable/ probe shall be provided. Coupling mode: Line to Line; Line (s) to ground (PE). Test level: shall meet the requirement of latest EN/IEC Waveform: The waveform requirement of Ring wave generator shall comply with latest EN/IEC Verification of the characteristics of the generator: Shall comply with all the requirements as per latest EN/IEC The generator characteristics shall be verified from an accredited lab compliant to ISO/IEC standard and certificate with data shall be provided. The certificate shall be in name of CPRI. All required verification kit for calibration/verification shall be provided.
10 Coupling/Decoupling network (CDN): Suitable CDN for AC/DC power supply ports, signal & control ports shall be provided. Coupling/Decoupling network (4 signal/data lines) for unshielded symmetrical & unsymmetrical interconnections lines shall be provided. The specification of CDN's are mentioned in page No. 2 of this document. The CDN s shall comply with all requirements of latest EN/IEC Waveform verification at the CDN output: The waveform and characteristics requirements detailed in latest EN/IEC shall be met for all coupling modes. The waveform characteristics shall be verified from an accredited lab compliant to ISO/IEC standard and certificate with data shall be provided. The certificate shall be in name of CPRI. All required verification kit for calibration/verification shall be provided. 6 Protection Overload, Over temperature. Indicate other protections. 7 Test routines The following specifications are minimum and bidder shall provide suitable test routines so as to meet the overall damped oscillatory wave and Ring wave test system requirements as per EN/IEC , EN/IEC , IEC and IEC standards. 1. User test routine: Customer specific routines. 2. Service: Service routines, setup. 3. Quick start: Immediate start, easy to use and fast shall be possible. 4. Standard test routine: According to EN/IEC , EN/IEC , IEC and IEC standards.
11 8 Software The following specifications are minimum and bidder shall provide suitable software so as to meet the overall damped oscillatory wave and Ring wave test system requirements as per the latest EN/IEC , EN/IEC , IEC and IEC standards. - To control the test including standard library, test report facility. - Windows based menu-driven, user friendly interactive operation. - Modular and flexible enough to allow the user to adapt the system to new Regulations / Standards or extend or modify the hardware due to new test requirements. - Software shall support Windows 7 and latest operating system. - Graphical representation of the results on computer screen. - Download the results data in internal / external memory. - Software license: 01 (One) Note: (1) List of all the test standards the software support shall be provided. (2) The license for all software s including bought out shall be submitted. (3) The software shall be upgradeable in future to handle the changes in the test standards for a period of 5 years without any additional charges. Software updates/version shall be provided free of charge. (4) Software operating instruction manual including stepby-step procedure for carrying out the tests as per standard shall be provided. (5) The bidder shall indicate the minimum computer system requirement (hardware & OS) for the software.
12 9 Communication Interface RS 232/USB/GPIB/IEEE 488/Ethernet(LAN), remote control interface allow programming of equipment functions from an external computer. 10 Front panel control and display Alpha-numeric with LCD display/software (Indicate other display) and easy menu structure. 11 Calibration The bidder shall provide the calibration certificate with calibration data for Damped oscillatory wave generator, Magnetic field coil, Ring wave generator & CDN s issued by the accredited calibration laboratory compliant to ISO/IEC standard traceable to recognized national standards laboratory upon delivery of the equipment. The calibration certificate shall be in the name of CPRI. Calibration certificate shall not be older than two months from date of shipment. General Specification 1 Input Supply voltage Single phase, 230V AC +10%/-15%, 50 Hz. Power cord suitable for Indian type conditions shall be provided. 2 Power consumption Bidder shall indicate the total power requirements for the proposed system. 3 Operating condition Temp: 15 to 35 C. RH: up to 75%. 4 Safety regulation EN/IEC and shall comply with relevant EMC & EMI standards. 5 Dimension and Weight Bidder shall indicate the Dimension and Weight of the proposed test equipment. Other Requirements 1 Accessories All standard accessories, interconnecting cables, connectors etc., shall be included. The bidder shall provide Oscilloscope requirement for verification of characteristics of Generators. 2 Spares The bidder shall recommend mandatory spares & shall be quoted separately. 3 Optional items All optional items shall be quoted separately.
13 4 System Documentation One (1) copy of documentation, inclusive of its softcopy covering the equipment installed shall comprise of the following: 1. Safety manual 2. Installation manual 3. Operating manual. 5 Training at CPRI Proposal shall include training for members of CPRI at site by a qualified trainer covering the following areas: - System Integration, operation and testing. - Demonstration & functionality of supplied equipment. - Demo for carrying out testing as per latest EN/IEC , EN/IEC , IEC and IEC standards. - Verification of the characteristics of Generator as per latest EN/IEC and IEC standards. - System maintenance & trouble shooting over view. - Safety considerations during operation & maintenance of the equipment. - Preventive and corrective maintenance of equipment. There should be a technically competent individual (or other resources) made available to CPRI to consult with on matters arising within the warranty period. The bidder shall appoint suitably qualified personnel authorized by the principal to provide on-site training. All costs towards training shall be borne by the bidder.
14 6 Installation, Commissioning and Testing The bidder shall be responsible for the installation, commissioning and test-run of equipment to the satisfaction of CPRI. When the installation is complete, the bidder shall demonstrate that the equipment meets the published specifications and provide instruction to CPRI personnel. All costs on installation, commissioning and test run of the equipment shall be borne by the bidder. 7 Warranty The equipment shall have a 2 years warranty (minimum). The warranty period starts after successful installation, commissioning and Provisional Acceptance Test at CPRI laboratory. The bidder shall also propose and quote the AMC charges separately (The scope of AMC shall be provided) after warranty period for a minimum of two (2) years at the time of tender submission. The AMC charges shall not be included in the quote & shall be quoted as option. The equipment shall be fully integrated and warranted by a single principal. The bidder shall enclose the Performance Warranty Letter from the Principal in relation to the equipment tested and commissioned by the bidder.
15 8 After Sales Service The bidder shall provide an original authorization letter from the principal signed by the authorized signatory. The bidder shall propose after sales service program including the response for the expected time to repair (ETTR). During warranty: Local support essential. After warranty/amc: Local support essential. Service call: within 24 hours it should be acknowledged; within 48 hours initial diagnosis; within one week it shall be resolved. Maintenance: Repair/service support during or after warranty shall be provided by the Indian agent during the entire life of the equipment. 9 Eligibility Criteria for Bidders The bidder shall provide documents establishing experience and capability as follows: The bidder shall have minimum of 3 year s experience in supplying similar or higher system. The end users list whose facility has been accredited to ISO/IEC standard shall be provided. The bidder shall provide the feedback from the users for the satisfactory performance of the test equipment. 10 Delivery period Differed delivery of items are recommended by CPRI. However, it will be informed on readiness of the Parent building. The bidders may indicate the delivery period in the quote. Note:- (1) The manufacturing of items shall start only on receipt of written confirmation from CPRI. (2) Shipment shall be made only after obtaining clearance from CPRI.
OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE
OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE FOR TESTS ACCORDING TO... > ANSI/IEEE C37.90 > ANSI/IEEE C62.41 > EN 61000-4-10 > EN 61000-4-12 > EN 61000-4-18 > IEC
More informationTo be completed by the Bidder. Sl.No. Parameters CPRI Specification / Requirements Qty
Revision N : 03 Issue No : 2 Dt of Revis : 25.07.207 Issue Dt. : 30.06.2003 Page No. : of 5 Issued by : P A CENTRAL POWER RESEARCH INSTITUTE, BHOPAL, Web: www.cpri.in, www.tenderwizard.com/cpri, Telefax:
More informationThe RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.
TECHNICAL SPECIFICATION FOR PORTABLE ELECTRONIC REFERENCE STANDARD METER (ERS) FOR TESTING OF SINGLE PHASE KILOWATT HOUR ENERGY METERS (ACCURACY CLASS 0. 2) 1. SCOPE: The specification covers the requirement
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) 1 MIG Tester Type MIG2000-6 Technical Specification E-MIG2000-6 revised: 07. May 2009 1 MIG Tester Type MIG2000-6 1
More informationSI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical
Section II Technical Specifications Tender enquiry no. : STDS/12-1/2016-17/PUR/STL/A-1849 Name of the equipment : SPECIFICATIONS OF SYSTEM FOR CONDUCTING DETERMINATION OF ERRORS TEST ON INSTRUMENT TRANSFORMERS
More informationCS114 + CS115 + CS116
System description Test Setup for MIL-STD-461 D, E&F CS114 + CS115 + CS116 1. MONTENA EMC... 2 1.1 PRODUCTS... 3 1.2 TURN KEY MIL STD 461 TEST INSTALLATIONS... 3 2. TEST SETUP DESCRIPTION... 4 2.1 TEST
More informationNovità sulla IEC ; -10; -12
Novità sulla IEC 61000-4-9; -10; -12 DIPL. ING. MARKUS FUHRER 11.06.2018 Content Recently revised standards IEC 61000-4-9 Ed. 2.0 2016-07 Impulse magnetic field IEC 61000-4-10 Ed. 2.0 2016-07 Damped oscillatory
More informationSchlöder GmbH - EMC Test and Measurement Systems Model #
Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD
More informationSurge Generator for MIL-STD 1275
Surge Generator for MIL-STD 1275 This generator PG1275 is specially designed for the test of the susceptibility to surges and spikes of military 28 Vdc electric circuits. The equipment allows performing
More informationTechnical Specification
LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification No. E-MIG0603IN2.doc revised: 20.October 2004 1 MIG Tester Type MIG0603IN2 1 MIG Tester Type MIG0603IN2 1 1.1 Introduction 1 2
More informationIEC Electrical fast transient / Burst immunity test
CONDUCTED RF EQUIPMENT POWER AMPLIFIERS IEC 61000-4-4 Electrical fast transient / Burst immunity test IEC 61000-4-4 Electrical fast transient / Burst immunity test Markus Fuhrer Phenomenom open a contact
More informationTechnical Specification
LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification E-MIG1203CWG revised: 22. June 2003 1 MIG Tester Type MIG1203CWG 1 MIG Tester Type MIG1203CWG 1 1.1 Introduction 1 2 General 2
More informationConducted Immunity Testing
EMC PARTNER COMPLETE TEST SOLUTIONS FOR Conducted Immunity Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management
More informationTHE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT
THE KENYA POWER AND LIGHTING CO. LTD SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT NAME DESIGNATION SIGNATURE DATE Compiled by Ephantus Nyagah Ag. Senior Engineer Checked by Eng. Thagichu Kiiru Deputy
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Intertek Japan K.K. Calibration Laboratory 3-2 Sunayama Kamisu Ibaraki 314-0255 JAPAN Ms. Masako Oyamada Phone: 81-465 89 2316 Fax: 81-465 89 2160 E-mail: masako.oyamada@intertek.com
More informationCONDUCTED IMMUNITY EMC TEST SYSTEM
System NSG 2050 is a modular, multi-role EMC test facility adaptable to meet variety of test specifi cations, from compliance with basic national and international standards, through detailed design characterisation
More informationFast transient burst simulator
Fast transient burst simulator FNS-AX4 series www.noiseken.com Fast transient / burst simulator FNS-AX4-A20/B63 Feature IEC 61000-4-4 Ed.3 standard compliance. Pre-check function is installed. Inspection
More informationSpecification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.
Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Scope: This specification defines the requirement of a Three
More informationCombination Wave Test System
Immunity Tests Combination Wave Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................
More informationMIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA
MIL Standard 461 G final release December 11 th, 2015 EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA CDN-UTP8 Ed. 3 - Universal The Swiss CDN company for data EMC and telecom
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationIssue No : 2 Dt of Revision :
PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No : 2 Dt of Revision : 17.9.2012 Issue Dt. : 30.06.2003 Page No. : 1 OF 3 Issued by : Q A Section : 0 Document : DQM-01 Topic : FORMAT
More informationEMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing
EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management
More informationTECHNICAL SPECIFICATION OF UNIVERSAL TYPE COMBINED THREE PHASE & SINGLE PHASE PORTABLE ELECTRONIC REFERENCE STANDARD METER CAPABLE OF TESTING OF ALL
TECHNICAL SPECIFICATION OF UNIVERSAL TYPE COMBINED THREE PHASE & SINGLE PHASE PORTABLE ELECTRONIC REFERENCE STANDARD METER CAPABLE OF TESTING OF ALL 1.0 Scope: TYPE OF HT AND LT METERS This specification
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61000-4-5 Second edition 2005-11 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques Surge immunity test This English-language
More informationUCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV
UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV FOR TESTS ACCORDING TO... > IEC 61000-4-4 > IEC 61000-4-5 > IEC 61000-4-8 > IEC 61000-4-9 > IEC 61000-4-11
More informationP331-2 set ESD generator (IEC )
User manual Probe set set ESD generator (IEC 61000-4-2) Copyright January 2017 LANGER GmbH 2017.01.09 User manual Table of contents: Page 1 ESD generator (IEC 61000-4-2) 3 1.1 Design and function of the
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More informationUCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY
UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY FOR TESTS ACCORDING TO... > ANSI/IEEE C62.41 > ECE-R10 > EN 61000-4-11 > EN 61000-4-29 > EN 61000-4-4 > EN 61000-4-5 > EN 61000-4-8
More informationLightning Surge Simulator LSS-F03 series
Lightning Surge Simulator LSS-F03 series Compliant with IEC61000-4-5 Edition 3 requirements Lightning Surge Simulator LSS-F03 series Feature "Output voltage 15kV, current 7500A" which can conduct breakdown
More informationTECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS
TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential
More informationMILITARY & AEROSPACE TESTING
EMC PARTNER CONDUCTED SUSCEPTIBILITY MILITARY & AEROSPACE TESTING WHEN GETTING RESULTS MATTERS THERE IS ONLY ONE CHOICE Military and avionic testing is all about quality and precision. MIL3000 brilliantly
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationFast Transient / Burst Simulator
EMC TESTS EQUIPMENTS CATALOGUE Fast Transient / Burst Simulator Reproduce showering arc at switching on/off of electric point of contact A simulator to reproduce fast repetitive frequency noises which
More informationTECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS
TR550004 TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR NO. 174001 EDITION 2.1 September 3 rd, 2018 Nippon Telegraph and
More informationUCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.
UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.5KV FOR TESTS ACCORDING TO... > EN 300329 > EN 300340 > EN 300342-1 > EN
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE (Main Laboratory) 5-1-1 Onna, Atsugi-shi, Kanagawa-ken, 243-0032 Japan (Commercial Office) 1-329 Kifune, Meito-ku Nagoya-shi,
More informationImmunity Testing for the CE Mark
Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationVoltage Transient Emission Test
Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along
More informationCOUPLING DECOUPLING NETWORK MODEL CDN-AF4
COUPLING DECOUPLING NETWORK MODEL CDN-AF4 II Warranty Com-Power warrants to its Customers that the products it manufactures will be free from defects in materials and workmanship for a period of 2 years.
More informationRIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.
RIGOL Data Sheet DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A Product Overview DG3000 Series Function/Arbitrary Waveform Generators adopt DDS technology, which enables
More informationEMC Seminar Series All about EMC Testing and Measurement Seminar 1
EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC
More informationTECHNICAL SPECIFICATION OF PORTABLE ELECTRONIC REFERENCE STANDARD ENERGY METER (ERS METER) FOR T E S T I N G O F HT THREE PHASE ENERGY METERS:-
TECHNICAL SPECIFICATION OF PORTABLE ELECTRONIC REFERENCE STANDARD ENERGY METER (ERS METER) FOR T E S T I N G O F HT THREE PHASE ENERGY METERS:- 1.0 SCOPE:- A lightweight electronic precision portable energy
More informationTHE MODULAR SOLUTION FOR 6 KV APPLICATIONS
THE MODULAR SOLUTION FOR 6 KV APPLICATIONS Teseq s new NSG 3060 conducted immunity generator takes the proven, user-friendly design of the highly successful Modula series to a new level. This innovative
More informationEMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter
Page 1 of 48 EMC TEST REPORT for Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Prepared for : Coliy Technology Co.,Ltd. Address : Block B,9 th Floor,Xinzhongtai Business Building,Gushu 2nd Road,Xi Town,Bao
More informationC-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply
C-Tick EMC TEST REPORT For AC/DC Switching Power Supply Model: CP0515(5V/1.5A); CP0520(5V/2A); CP0530 (5V/3A); CP0540 (5V/4A); CP0550 (5V/5A); CP0560 (5V/6A);CP0615(6V/1.5A); CP0620(6V/2A); CP0625 (6V/2.5A);
More informationRIGOL Data Sheet. DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A. Product Overview. Main Features.
RIGOL Data Sheet DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A Product Overview DG2000 Series Function/Arbitrary Waveform Generators adopt DDS technology, which enables to generate
More informationCOMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) COMPACT NX5 MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV FOR TESTS ACCORDING
More informationINSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:
A V T E C H E L E C T R O S Y S T E M S L T D. N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P.O. BOX 265 OGDENSBURG, NY U.S.A. 13669-0265 TEL: 888-670-8729 (USA & Canada)
More informationAC/DC Current Probe TCP0150 Datasheet
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com AC/DC Current Probe TCP0150 Datasheet Low noise and DC drift Provides automatic units scaling and readout
More informationHigh Stability Voltage Source
Bilt System module - BE2100 High Stability Voltage Source Voltage to ±12V, current to ±200mA High Resolution: 21 bits, 6 ½ digits Ultra Low Noise: down to 6µVp-p Clean output noise spectrum with no spike
More informationWaveStation Function/Arbitrary Waveform Generators
WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in
More informationCDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M
1 CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL 601-142M CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL CDN 117 / 117-M
More informationAvionics Test System. Lightning Tests
Lightning Tests Avionics Test System Avionics Test System Overview 2 Features & Benefits 4 Application Options 6 Applicable Standards 7 Generator Specifications 8 Accessories and Options 10 Software 17
More informationEMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationBumbleBee. High Voltage Differential Probe Ord.-No: Features:
High Voltage Differential Probe Ord.-No: 880-102-501 Features: 2000 V rms Measurement Category I, 6000 V transient Overvoltage 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating
More informationEMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009
EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009 Our trek started in a small laboratory over 25 years ago. Since then, we ve been focused on making EMC measurements easier and the measuring
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationSystem description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7
Ultra Wide Band test setup System description 1. UWB TEST SYSTEM DESCRIPTION... 2 2. SYSTEM MONITORING... 5 3. OTHER MEASUREMENT SYSTEMS & ACCESSORIES... 6 3.1 OSCILLOSCOPE & SHIELDED ENCLOSURE... 6 3.2
More informationELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS
Academic Year 2015-2016 ELEC 0017: ELECTROMAGNETIC COMPATIBILITY LABORATORY SESSIONS V. BEAUVOIS P. BEERTEN C. GEUZAINE 1 CONTENTS: EMC laboratory session 1: EMC tests of a commercial Christmas LED light
More informationAdvanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.
Lightning Surge Simulator Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) LSS-F02 www.noiseken.com Conforming to IEC61000-4-5 ed2 Standard LSS-F02 series A simulator
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 JEL LIMITED 2971 Nakabyo, Abiko-City Chiba-Prefecture, 270-1121, JAPAN Keiichiro Murata Phone: +81 4 7188 5333 Email: murata@jel.co.jp CALIBRATION Valid To:
More informationDDA55 DISCONTINUOUS DISTURBANCES ANALYSER
DDA55 DISCONTINUOUS DISTURBANCES ANALYSER Fully digital analyser for measurement of discontinuous disturbances Compact designed and manufactured compliant to CISPR 16 International Standard for measurements
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationRIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design
RIGOL Data Sheet DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator Product Overview DG1000 series Dual-Channel Function/Arbitrary Waveform Generators adopt DDS technology, which enables
More informationVERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters
VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters Revised: 21.December 2010 1 General Information To oscilloscope VERI50 EFT To generator 1.1 Technical data
More informationArbitrary/Function Waveform Generators 4075B Series
Data Sheet Arbitrary/Function Waveform Generators Point-by-Point Signal Integrity The Arbitrary/Function Waveform Generators are versatile high-performance single- and dual-channel arbitrary waveform generators
More informationEMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011
EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011 All-in-one Digital EMI Analyzer 10 Hz - 3 GHz PMM 9010/30P EMI Analyzer 10 Hz - 3 GHz Our trek started in a small laboratory over 25
More informationIn late 2011, The International Standards
CISPR 32: New International Standard on Electromagnetic Emissions from Multimedia Equipment DAN HOOLIHAN Hoolihan EMC Consulting Lindstrom, Minnesota USA In late 2011, The International Standards Commission's
More informationRegulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany
Emission Measurements Regulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany Martin Lutz, Reto Casanova, Nicholas Wright Contents 1. Introduction... 2
More informationPHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design
High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip Certificate of Calibration available on request Read-out BNC Connector
More informationAppendix A: Specifications
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Appendix A: Specifications This section provides a complete description of the video measurement set specifications.
More informationRF Conducted Immunity and Automotive Transient Generator Test Systems
August 2008 RF Conducted Immunity and Automotive Transient Generator Test Systems rf/microwave instrumentation 1 This Will Get Your Pulse Going at whatever rate you need! DUT Coupling Network TGA20000
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) 6500 Series Loop Antennas User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described
More informationCOMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV
COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV FOR TESTS ACCORDING TO... > IEC 61000-4-4 > IEC 61000-4-5 > IEC 61000-4-8 > IEC 61000-4-9 >
More informationPROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. :
Revision No. : 03 Page 1 of 5 1 Place where equipment to be supplied 1. CPRI, Hyderabad 2. CPRI, Bhopal 3. CPRI, Noida 4. EMC, Trivandrum 1 set at each location 2 Scope (supply / supply & Installation
More informationPower Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report
PSL Standards Lab 980 Atlantic Avenue Alameda, CA 94501 USA TEL ++1-510-522-4400 FAX ++1-510-522-4455 www.standards.com Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report IEC 62053-22
More informationWaveStation Function/Arbitrary Waveform Generators
Function/Arbitrary Waveform Generators Key Features High performance with 14-bit waveform generation, up to 500 MS/s sample rate and up to 512 kpts memory 2 channels on all models Large color display for
More informationPhysical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free
Physical Properties Measurement System (PPMS): A Cryogen-free Physical Properties Measurement system that operates over a wider range of temperature and magnetic fields: fully automated/computer controlled
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationLow Frequency Measuring System
Emission Measurements Low Frequency Measuring System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................
More informationTechnical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent
Technical Requirements for Resistibility of Telecommunications Equipment to Overvoltage and Overcurrent TR NO.189001 Edition 3 1st, April, 2018 Nippon Telegraph and Telephone Corporation Notice This document
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationCoupling/Decoupling Networks (CDN)
Coupling/Decoupling Networks (CDN) For immunity testing according to IEC / EN 61000-4-6 Immunity testing CDNs are the preferred coupling and decoupling devices, for reasons of test reproducibility and
More informationAMERICAN NATIONAL STANDARD
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 81 2007 Surge Withstand Test Procedure NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards
More informationWaveStation Function/Arbitrary Waveform Generators
WaveStation Function/Arbitrary Waveform Generators Key Features High performance with 14-bit, 125 MS/s and 16 kpts 2 channels on all models Large 3.5 color display for easy waveform preview Over 40 built-in
More informationSpectrum Analyzers 2680 Series Features & benefits
Data Sheet Features & benefits n Frequency range: 9 khz to 2.1 or 3.2 GHz n High Sensitivity -161 dbm/hz displayed average noise level (DANL) n Low phase noise of -98 dbc/hz @ 10 khz offset n Low level
More informationCOMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV
COMPACT NX5 SERIES MULTIFUNCTIONAL TEST GENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 5.5 KV FOR TESTS ACCORDING TO... > IEC 61000-4-4 > IEC 61000-4-5 > IEC 61000-4-8 > IEC 61000-4-9 >
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More informationTechnical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories
Technical Criteria for the Accreditation Of Electromagnetic Compatibility (EMC) And Radio Testing Laboratories ACIL - American Council of Independent Laboratories 1629 K Street, NW, Washington, DC 20006-1633
More informationCenter for Quality Engineering. Test Report No.: B0JA0002
DAT-P-002/91-02 Center for Quality Engineering Test Report No.: Order No.: B0JA Pages: 10 Munich, Sep 12, 2008 Client: Infineon Technologies AG OP TTR RPT 2 Equipment Under Test: Manufacturer: Task: Test
More informationAC/DC Current Oscilloscope Probe Model SL261
AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated
More informationPROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:
Programmable AC Power Source MODEL 6500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES The global AC power testing requirements demand more sophisticated AC Power Source that is capable
More informationRIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview The DS1000E, DS1000D series instruments are economical, high-performance digital oscilloscopes.
More informationTRANSMITTER MODEL: KAS-2030M
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved
More informationCAR - TEST - SYSTEM 14
CAR - TEST - SYSTEM 14 EMC-Test Equipment for electrical installation of vehicles Acc. to ISO 7637-2, ISO 16750-2 ISO 21848 Rise time variable 1-5µs Pulse Waveforms : #1 1-5/2000µs, 600 V, ISO 1-5/1000µs,
More informationINTRODUCTION TO CONDUCTED EMISSION
IEEE EMC Chapter - Hong Kong Section EMC Seminar Series - All about EMC Testing and Measurement Seminar 2 INTRODUCTION TO CONDUCTED EMISSION By Duncan FUNG 18 April 2015 TOPICS TO BE COVERED Background
More informationesa Space Station Electromagnetic Emission and Susceptibility Requirements International Space Station Revision C May 31, 1996 SSP Revision C
Space Station Electromagnetic Emission and Susceptibility Requirements International Space Station Revision C May 31, 1996 esa european space agency National Aeronautics and Space Administration Space
More information