Schlöder GmbH - EMC Test and Measurement Systems Model #

Similar documents
Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Coupling/Decoupling Networks (CDN)

Coupling/Decoupling Networks (CDN)

MGA Magnetic field system. DC khz

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

Coupling / decoupling network (CDN) for screened or coaxial cables

Data sheets CDN-M, CDN-AF, CDN-S, CDN-T, CDN-RJ, CDN-USB

RADIATED IMMUNITY TEST SYSTEMS

Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

COUPLING DECOUPLING NETWORKS FOR IEC / EN

EMC TEST SYTEMS / INSTRUMENTS AND CONTROL SOFTWARE

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

Conducted Immunity Testing

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

MONITORING DEVICE 4 khz to 400 MHz

Technical Specification

Surge Generator for MIL-STD 1275

LANGER EMV-TECHNIK. Operating Instructions. A 100 / A 200 / A 300 Optical Fibre Probe

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

Technical Specification

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

IEC Electrical fast transient / Burst immunity test

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

D10 Demonstration Board

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Voltage Transient Emission Test

Insulation Test System

ELECTRONICS TESTING CENTER(ETC), TAIWAN

LS200 TEST DATA IEC61000 SERIES

We re In The Business Of Making Your Life Easier

ACCREDITED LABORATORY. LIBERTY LABS, INC. Kimballton, IA for technical competence in the field of Calibration

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

Insulation Test System

Trees, vegetation, buildings etc.

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

TEST REPORT... 1 CONTENT...

Combination Wave Test System

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B


Fast Transient / Burst Simulator

Lightning Surge Simulator LSS-F03 series

P331-2 set ESD generator (IEC )

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Loop & Magnetic Field Coil

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

RADIATED IMMUNITY TEST SYSTEM 6 GHz

Advanced Test Equipment Rentals ATEC (2832)

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

Advanced Test Equipment Rentals ATEC (2832)

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Avionics Test System. Lightning Tests

High precision measurement system for current and voltage IHC-A/B-RM01/03

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan

For the National Voluntary Laboratory Accreditation Program

MILITARY & AEROSPACE TESTING

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Coils Loop sensors / radiating loops / Helmholtz coils

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

DECLARATION OF CONFORMITY

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

CE EMC Test Certification

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

1 SUMMARY OF STANDARDS AND RESULTS

Vector Network Analyzers ZVB

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

Oscilloscope Probes and Accessories

EMI Test Lab LLC Electro Magnetic Interference Testing EmiTestLab.com

EMC Test Report. Report Number: M030826

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

CS114 + CS115 + CS116

EMC LAB EQUIPMENT CALIBRATION SCHEDULER

TesT system for ConduCTed and radiated immunity

Fast transient burst simulator

CE TEST CERTIFICATION

Transcription:

Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD generator 30 kv CON / 30 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 30000 ESD generator 30 kv CON / 30 kv AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pf/ 330 ohm, mechanical polarity module (to reverse the polarity of the pulses, the module must be removed, turned 180 degrees and reinserted), includes factory calibration for 150 pf/330 ohm SESD 30000 P ESD generator 30 kv CON / 30 kv AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pf/ 330 ohm, electronic polarity module (A Polarity Switch allows the user to quickly and easily change the polarity of the pulses), includes factory calibration for 150 pf/330 ohm SESD 30000 A SESD 30 S 100 KAL SESD 30000-1 KAL SESD 30000-4 KAL SESD 30000-9 SESD 30 C 50 SESD 30 C 100 SESD 30 C 150 SESD 30 C 200 SESD 30 C 250 SESD 30 C 300 SESD 30 C 330 SESD 30 C 500 SESD 30 C 680 SESD 30 C 1000 SESD 30 R 0 SESD 30 R 50 SESD 30 R 100 SESD 30 R 150 SESD 30 R 200 SESD 30 R 250 SESD 30 R 330 SESD 30 R 500 SESD 30 R 560 SESD 30 R 1000 SESD 30 R 1500 SESD 30 R 2000 SESD 30 R 5000 SESD 30 P 200 SESD 30 M 200 SESD 30 T 630 SESD 3036 SESD 3036 SESD 30 Z 01 SESD 30 Z 02 SESD 3021 SESD 3025 SESD 3026 SESD 3027 ESD generator 30 kv CON / 30 kv AIR acc. to IEC 61000-4-2 and ISO 10605/2008, 150 pf/ 330 ohm, electronic polarity module, includes factory calibration for 150 pf/330 ohm, battery and main operation, includes factory calibration for 150 pf/330 ohm Control software ESD, with optical interface and fiber optic cable 10m. For the generators SESD 216, SESD 230, SESD 30000 refers to the impedances 150 pf / 330 Ω (IEC), because the conversion with the HBM module in ISO 10605 calibration (4 impedances 202 values), before delivery of a new ESD generator, if refers to the impedances 100 pf / 1500 Ω, only rise time and peak current are measured becau Capacity module 50 pf Capacity module 100 pf Capacity module 150 pf Capacity module 200 pf Capacity module 250 pf Capacity module 300 pf Capacity module 330 pf Capacity module 500 pf Capacity module 680 pf Capacity module 1000 pf Resistor module 0 ohm,only for AIR discharge,c max 330 pf Resistor module 50 ohm Resistor module 100 ohm Resistor module 150 ohm Resistor module 200 ohm Resistor module 250 ohm Resistor module 330 ohm Resistor module 500 ohm Resistor module 560 ohm Resistor module 1000 ohm Resistor module 1500 ohm Resistor module 2000 ohm Resistor module 5000 ohm Electronic polarity module Fast discharge module, rise time < 400 ps Balancer for ESD Hook on the generator - for hanging on a balancer. Before delivery of a new ESD generator, if a customer purchase a new ESD generator Hook on the generator - for hanging on a balancer. Mounting a hook for an existing customer SESD xxx generator BNC trigger output, instead of a trigger input Special module with HV cable 1m long (instead of test tip) Test tip (metal part) Contact discharge, 30 kv, standard Test tip (metal part) Air discharge, 30 mm half ball Test tip (metal part) CON with spring contact, 50 mm long Test tip (metal part) CON with spring contact, 70 mm long

SESD 30 MOD-1 HBM (Human Body Model) module 5 ns (100 pf/1500 ohm), 100 pf module and 330 ohm module are needed - the 1500Ω are obtained by the HBM module + 330 ohm. Included plot. SESD 30 MOD-1-U2 Modification of an existing SESD 30000 for option HBM (MOD-1) SESD 30 MOD-3-U1 Modification of an existing SESD 30000 for automatic absorbing. Calibration has to be quoted additionally. SESD 231 Discharge return cable, 2m long SESD 271 VCP vertical coupling plate, include earth cable SESD 272 SESD 272 Earth cable include 2 x 470 kohm resistor, 2 m long SESD 8800-4 ESD calibration set 2 ohm (4 GHz), traceable to National standard. Necessary acc. to the new revision of the standard IEC 61000-4-2. Included accredited calibration. ATT-20 Additional attenuator 20 db for the SESD 8800-4 SESD 2910 ESD test system, 30 kv for testing electro explosive devices acc. EN 13763-13- Basic unit, includes electronic polarity module, RS 232 interface. SESD 29 R 05 Resistor module 0,5 ohm SESD 29 R 2 Resistor module 2 ohm SESD 29 R 5 Resistor module 5 ohm SESD 29 R 10 Resistor module 10 ohm SESD 29 R 20 Resistor module 20 ohm SESD 29 R 150 Resistor module 150 ohm SESD 29 R 330 Resistor module 330 ohm SESD 29 R 500 Resistor module 500 ohm SESD 29 R 2000 Resistor module 2000 ohm SESD 29 R 5000 Resistor module 5000 ohm SESD 29 C 150 Capacity modules 150 pf SESD 29 C 200 Capacity modules 200 pf SESD 29 C 300 Capacity modules 300 pf SESD 29 C 330 Capacity modules 330 pf SESD 29 C 470 Capacity modules 470 pf SESD 29 C 500 Capacity modules 500 pf SESD 29 C 1000 Capacity modules 1000 pf SESD 29 C 1500 Capacity modules 1500 pf SESD 29 C 2000 Capacity modules 2000 pf SESD 29 C 2500 Capacity modules 2500 pf SESD 29 C 3000 Capacity modules 3000 pf SESD 29 C 3500 Capacity modules 3500 pf SESD 29 C 5000 Capacity modules 5000 pf SESD 2990 Transport case for max. 12 modules IEC / EN 61000-4 - 4 Burst SFT 1400 Burst generator 125 khz, 5 kv, acc. to IEC 61000-4-4 SFT 1420 Burst generator 2 MHz, 4.8 kv acc. to IEC 61000-4-4 SFT 415 Capacity clamp to test I/O leads, in conformity with IEC 61000-4-4, includes the high-voltage cable. SFT 415-1 Capacity clamp to test I/O leads, in conformity with IEC 61000-4-4 with special protection against touch, includes the high voltage cable. SFT 415-CS Calibration Set for calibration of the capacity coupling clamp acc. IEC 61000-4-4, 2012 SFT 450-1 50 Ohm Attenuator for calibration SFT 415; 54 db, conform divider 500:1 at 50 ohm termination (scope input) SFT 450-2 1000 Ohm Attenuator for calibration SFT 415 and SFT 1400, 1420; 60 db, conform divider 1000:1 at 50 ohm termination (scope input) SFT 450-Set 50 Ohm and 1000 Ohm Attenuator for calibration the SFT 415 and SFT 1400, SFT 1420 SFT 470 Probe set for Burst generator, to create short time magnetic fields IEC / EN 61000-4 - 5 Surge CWG 1500 Surge generator according to IEC 61000-4-5, max. 4,4 kv CWG 520 3-phase coupling network, 400 V / 4 x 16 A for burst and surge CWG 520-550 3-phase coupling network, max. 550 V / 4 x 16 A for burst and surge CWG 523 3-phase coupling network, 400 V / 4 x 32 A for burst and surge CWG 523-550 3-phase coupling network, max. 550 V / 4 x 32 A for burst and surge

CWG 524 3-phase coupling network, 400 V / 4 x 60 A for burst and surge CWG 524-550 3-phase coupling network, max. 550 V / 4 x 60 A for burst and surge CWG 524-B 3-phase coupling network, 400 V / 4 x 60 A, for burst coupling only CWG 1525 Coupling network, 2 unshielded symmetrical data lines (field bus, interconnectin lines), 1 A, max. 50V AC/DC, coupling via gas arrestors CWG 1526-4 Coupling network, 0,5uF / 40 Ohm, 2 unshielded unsymmetrical interconnection lines, 4A/ 240 VAC, 120 VDC CWG 1526-10 Coupling network,, 2 unshielded unsymmetrical interconnection lines, 10A/ 240 VAC, 120 VDC CWG 1528 Coupling network, 0,5uF / 40 Ohm, 4 unshielded unsymmetrical interconnection lines, 6 A, 3 x 250 VAC, max. 120 VDC; Remote control RS 232 CWG 550 External 18 μf capacitor within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kv, include HV cable 35 cm, for verification of the Surge pulse / tests to cable shields. CWG 553 0,5 μf capacitor + 40 Ohm resistor within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014; max. 250 VAC, max. 400 VDC, max. pulse voltage 4,4 kv, include HV cable 90 cm, for verification of the Surge pulse / tests to cable shields. CWG 554 External 18 μf and 9 μf capacitor and 10 ohm within a housing, acc. IEC 61000-4-5 Ed.3.0, 2014, max. 550 VAC, 1200 VDC, max. pulse voltage 6,0 kv, for Surge tests without coupling networks to cable shields and verification of the Surge pulse. Includes HV cable, to connect to the CWG 1500 CDG 6000-DC Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 khz 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 db), - built-in directional coupler CDG 6000 Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 khz 300 MHz, amplifier 25W for 10 V (15 V) with 80% AM (without 6 db), - without directional coupler CDG 6000-75-DC Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 khz 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - built-in directional coupler CDG 6000-75 Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 100 khz 300 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - without directional coupler CDG 6000-75-DC_10 Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 10 khz 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - built-in directional coupler CDG 6000-75_10 Conducted RF generator, acc. IEC 61000-4-6, Ed.4.0, 10 khz 250 MHz, amplifier 75W for 30 V (40 V) with 80% AM (without 6 db), - without directional coupler CDG 6050 6 db Attenuator, 20W, for test level max. 20V CDG 6050-100W 6 db Attenuator, 100W Coupling networks - Calibration adapters required Special CDNs upon requirement CDN L1-16 1 line, 250VAC, 16A, 150 khz 230 MHz, 4mm MC jack, black CDN M1 ground cable PE, 250 VAC, 150 khz 230 MHz, 4mm jack, gn/yellow CDN M1_10 ground cable PE, 250 VAC, 10 khz 230 MHz, 4mm jack, gn/yellow CDN M2-16 2 lines L + N, 250 VAC, 16 A, 150 khz 300 MHz CDN M2-16_10 2 lines L + N, 250 VAC, 16 A, 10 khz 230 MHz CDN M2-32 2 lines L + N, 250 VAC, 32 A, 150 khz 230 MHz CDN M2-32 HV 2 lines L + N, 600 VAC, 32 A, 150 khz 230 MHz CDN M2-63 HV 2 lines L + N, 600 VAC, 63 A, 150 khz 80 MHz CDN M2-100 HV 2 lines L + N, 600 VAC, 100 A, 150 khz 80 MHz CDN M2+M3-16 2 + 3 lines, switchable, 250 VAC, 16 A, 150 khz 300 MHz CDN M2+M3-16_10 2 + 3 lines, switchable, 250 VAC, 16 A, 10 khz 230 MHz CDN M2+M3-32 2 + 3 lines, switchable, 250 VAC, 32 A, 150 khz 230 MHz CDN M3-16 3 lines L + N + PE, 250 VAC, 16 A, 150 khz 300 MHz CDN M3-L16 3 lines 3 x L, 250 VAC, 16 A, 150 khz 230 MHz CDN M3-32 3 lines L + N + PE, 250 VAC, 32 A, 150 khz 230 MHz CDN M3-L32 3 lines 3 x L, 250 VAC, 32 A, 150 khz 230 MHz CDN M3-L32_10 3 lines 3 x L, 250 VAC, 32 A, 10 khz 230 MHz CDN M3-LN32 3 lines L1 + L2 + N, 250 VAC, 32 A, 150 khz 230 MHz CDN M3-32 HV 3 lines L + N + PE, 600 VAC, 32 A, 150 khz 80 MHz CDN M3-63 HV 3 lines L + N + PE, 600 VAC, 63 A, 150 khz 80 MHz CDN M3-100 HV 3 lines L + N + PE, 600 VAC, 100 A, 150 khz 80 MHz CDN M3-L100 HV 3 lines, 3 x L 600 VAC, 100 A, 150 khz 80 MHz

CDN M4-16 4 lines 3 x L, 1 x PE, 250 VAC, 16 A, 150 khz 230 MHz CDN M4-N16 4 lines 3 x L, 1 x N, 250 VAC, 16 A, 150 khz 230 MHz CDN M4-32 4 lines 3 x L, 1 x PE, 250 VAC, 32 A, 150 khz 230 MHz CDN M4-N32 4 lines 3 x L, 1 x N, 250 VAC, 32 A, 150 khz 230 MHz CDN M4-32 HV 4 lines 3 x L, 1 x PE, 600 VAC, 32 A, 150 khz 80 MHz CDN M4-32_10 4 lines 3 x L, 1 x PE, 250 VAC, 32 A, 10 khz 230 MHz CDN M4-N63 HV 4 lines 3 x L, 1 x N, 600 VAC, 63 A, 150 khz 80 MHz CDN M4-63 HV 4 lines 3 x L, 1 x PE, 600 VAC, 63 A, 150 khz 80 MHz CDN M4-100 HV 4 lines 3 x L, 1 x PE, 600 VAC, 100 A, 150 khz 80 MHz, incl. cable 3m with 2 plugs. CDN M4-N100 HV 4 lines 3 x L, 1 x N, 600 VAC, 100 A, 150 khz 80 MHz, incl. cable 3m with 2 plugs. CDN M5-16 5 lines 3 x L, 1 x N, 1 x PE, 250 VAC, 16 A, 150 khz 230 MHz CDN M5-32 5 lines 3 x L, 1 x N, 1 x PE, 250 VAC, 32 A, 150 khz 230 MHz CDN M5-32 HV 5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 32 A, 150 khz 80 MHz CDN M5-32 VHV 5 lines 3 x L, 1 x N, 1 x PE, 1000 VAC, 32 A, 150 khz 80 MHz CDN M5-63 HV 5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 63 A, 150 khz 80 MHz CDN M5-100 HV 5 lines 3 x L, 1 x N, 1 x PE, 600 VAC, 100 A, 150 khz 80 MHz CDN S 1-75 1 screened line, 75 Ohm connector BNC, 150 khz 230 MHz CDN S 1 1 screened line, connector BNC, 150 khz 230 MHz CDN S 1_10 1 screened line, connector BNC, 10 khz 230 MHz CDN S 2 2 screened lines, connector XLR, 150 khz 230 MHz CDN S 2_10 2 screened lines, connector XLR, 10 khz 230 MHz CDN S 3_10 3 screened lines, connector XLR, 10 khz 230 MHz CDN S 4 screened lines, connector XLR, 5 pole, 150 khz 230 MHz CDN S 8 screened lines, connector 8 pole Mini DIN, 150 khz 230 MHz CDN S 9 screened lines, connector 9-pol SUB-D, 150 khz 230 MHz CDN S 9_10 screened lines, connector 9-pol SUB-D, 10 khz 230 MHz CDN S 15 screened lines, connector 15-pol SUB-D, 150 khz 230 MHz CDN S 25 screened lines, connector 25-pol SUB-D, 150 khz 230 MHz CDN S K75-BNC Screened lines, for coaxial-cable 75 Ohm, BNC 150 khz 230 MHz CDN AF 2 2 unscreened non balanced lines, terminal clamp, 150kHz 300MHz CDN AF 2-MC 2 unscreened non balanced lines, 4mm MC jacks,150khz 300MHz CDN AF 2-MC_10 2 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 3 3 unscreened non balanced lines, terminal clamp, 150kHz 230MHz CDN AF 3-MC 3 unscreened non balanced lines, 4mm MC jacks,150khz 230MHz CDN AF 3-MC_10 3 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 4 4 unscreened non balanced lines, terminal clamp, 150kHz 230MHz CDN AF 4_10 4 unscreened non balanced lines, terminal clamp, 10 khz 230MHz CDN AF 4-MC 4 unscreened non balanced lines, 4mm MC jacks, 150kHz 230MHz CDN AF 4-MC_10 4 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 5-MC 5 unscreened non balanced lines, 4mm MC jacks, 150kHz 230MHz CDN AF 5-MC_10 5 unscreened non balanced lines, 4mm MC jacks, 10kHz 230MHz CDN AF 8 8 unscreened non balanced lines, terminal clamp, 150kHz 230MHz CDN AF 8_10 8 unscreened non balanced lines, terminal clamp, 10kHz 80MHz CDN AF 8-MC 8 unscreened non balanced lines, 4mm MC jacks, 150kHz 80MHz CDN AF 8-MC_10 8 unscreened non balanced lines, 4mm MC jacks, 10kHz 80MHz CDN AF 8-SUBD_10 8 unscreened non balanced lines, 4mm SUB-D9, 10kHz 230MHz CDN AF 12 SUB-D 12 unscreened non balanced lines, SUB-D15, 150kHz 230MHz CDN T 2 2 unscreened balanced lines, terminal clamp, 150 khz 230 MHz CDN T 2_10 2 unscreened balanced lines, terminal clamp, 10 khz 80 MHz CDN T 4 4 unscreened balanced lines, terminal clamp, 150 khz 230 MHz CDN T 4_10 4 unscreened balanced lines, terminal clamp, 10 khz 80 MHz CDN T 8 8 unscreened balanced lines, terminal clamp, 150 khz 230 MHz CDN RJ 11 unscreened lines, 6 pins, RJ11 connector, 150 khz 230 MHz CDN RJ 45 unscreened lines, 8 pins, RJ45 connector, 150 khz 230 MHz CDN RJ 45S screened lines, 8 pins, screened RJ45 connector, 150 khz-230 MHz CDN RJ 45S_10 screened lines, 8 pins, screened RJ45 connector, 10 khz-230 MHz CDN HDMI screened lines, 19 pins, screened HDMI connector, 150kHz-230MHz, HDMI 1.3a CDN Firewire CDN for IEEE 1394 units, 6 pol, Firewire jack, 150 khz - 230 MHz

CDN CAN-BUS L4 CDN for CAN-BUS, 9 pol SUB-D socket, 150 khz - 230 MHz CDN CAN-BUS L5 CDN for CAN-BUS, 9 pol SUB-D socket, 150 khz - 230 MHz CDN USB-C CDN for central USB units, 8 pins connector, 150 khz - 230 MHz, EUT side: USB-B -> square, AE side: USB-A -> flat CDN USB-C_10 CDN for central USB units, 8 pins connector, 10 khz-230 MHz, EUT side: USB-B -> square, AE side: USB-A -> flat CDN USB-P CDN for periphery USB units, 8 pins connector, 150 khz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square CDN USB-P_10 CDN for periphery USB units, 8 pins connector, 10 khz-230 MHz, EUT side: USB-A -> flat, AE side: USB-B -> square CDN USB-3.0 CDN for USB 3.0, 150 khz-230 MHz, EUT side: USB-A -> flat, AE side: USB-A -> flat CDN D 100 100 ohm resistor for direct injection, connectors: BNC / alligator clip CDNs for Emissions Testing CDN M2-16_9K EMI 2 lines L + N, for emissions testing, 250 VAC, 16A, 9 khz 300 MHz CDN M3-16_9K EMI 3 lines L+N+PE, for emissions testing, 250 VAC, 16A, 9 khz 300MHz Calibration material CDG A 3100 Mounting plate include 50/150 ohm passage and 50 ohm termination CDG 3110 100 Ohm resistor (50/150 ohm passage) BNC to BNC CDG A 3101 Calibration adaptor for CDN M3, M2, M1, L1 16A / 32A CDG A 3107 Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (AE-port) CDG A 3128 Calibration adaptor for CDN M5/M4-16/32A / AF5/AF4-MC (EUTport) CDG A 3125 Calibration adaptor for CDN M3, M2, 63A CDG A 3126 Calibration adaptor for CDN M3, M2, 100A CDG A 3115 Calibration adaptor for CDN M5, M4, 63A CDG A 3116 Calibration adaptor for CDN M5, M4, 100A CDG A 3102 Calibration adaptor for CDN AF 2 CDG A 3101 Calibration adaptor for CDN AF 2-MC CDG A 3108 Calibration adaptor for CDN AF 3 CDG A 3101 Calibration adaptor for CDN AF 3-MC CDG A 3108 Calibration adaptor for CDN AF 4 CDG A 3107 Calibration adaptor for CDN AF 5/AF4-MC (AE-port) CDG A 3128 Calibration adaptor for CDN AF 5/AF4-MC (EUT port) CDG A 3110 Calibration adaptor for CDN AF 8 CDG A 3114 Calibration adaptor for CDN AF 8-MC CDG A 3143 Calibration adaptor for CDN AF 12-SUBD CDG A 3103 Calibration adaptor for CDN S 1 CDG A 3104 Calibration adaptor for CDN S 2 CDG A 3130 Calibration adaptor for CDN S 4 CDG A 3129 Calibration adaptor for CDN S 8 CDG A 3105 Calibration adaptor for CDN S 9 CDG A 3113 Calibration adaptor for CDN S 15 CDG A 3106 Calibration adaptor for CDN S 25 CDG A 3144 Calibration adaptor for CDN S K75-BNC CDG A 3111 Calibration adaptor for CDN T2 CDG A 3112 Calibration adaptor for CDN T4 CDG A 3109 Calibration adaptor for CDN T8 CDG A 3117 Calibration adaptor for CDN RJ 45 S CDG A 3118 Calibration adaptor for CDN RJ 45 CDG A 3120 Calibration adaptor for CDN RJ 11 CDG A 3121 Calibration adaptor for CDN USB-C (also USB 3.0C) CDG A 3122 Calibration adaptor for CDN USB-P (also USB 3.0P) CDG A 3123 Calibration adaptor for CDN HDMI CDG A 3127 Calibration adaptor for CDN Firewire CDG A 3131 Calibration adaptor for CDN CAN-BUS, 9-pol SUB-D male and CDN AF 8-SUBD_10 Coupling clamps CDN DCL-20 Decoupling clamp for immunity, acc. IEC 61000-4-6, 100 khz 1000 MHz, cable diameter max. 20mm.

CDN EMCL-20 EM clamp acc. to /EC/EN 61000-4-6 incl. calibration kit and factory calibration, traceable, cable diameter max. 20 mm CDN EMCL-35 EM clamp acc. to /EC/EN 61000-4-6 incl. calibration kit and factory calibration, traceable, cable diameter max. 35 mm CDN-EMCL-NW_10 Matching network 10 khz 150 khz, for using EMCL 20 from 10 khz to 150 khz KAL SET EMCL Calibration set for EMCL, acc. IEC 61000-4-6, Ed. 4.0, 2014 IEC / EN 61000-4 - 8 / EN 55103 / MIL STD / ISO DC - 250 khz MGA 1033 Magnetic field analyzer and generator acc. to EN 55103 + IEC 6100-4-8 + MIL-STD-461 E/F, DC-250 khz, Amplifier 50V / 16A MGA 1034_16-SYS Complete Test-System for Magnetic field tests acc. ISO 11452-8, MIL-STD-461 E/F and other incl. compensation board and Triax Coil MGA_HCST_50-28 for magnetic fields until 1000 A/m at 1000 Hz, DC 250 khz, Amplifier 50V / 16A MGA_RLS 133 Radiating / Loop sensor 133 mm acc. to EN 55103-2, incl. 3m cable MGA_RL 120 Radiating loop 120 mm acc. to MIL-STD-461E / RS101, 3m cable MGA_BC-500 Radiating loop 50 cm, acc. to EN 55103-2, item A 3.1 MGA_LS 040 Loop sensor 40 mm acc. to MIL-STD-461E / RE101, incl. 3m cable MGA_LS 133 Loop sensor 133 mm acc. to MIL-STD-461E / RE101, 3m cable MGA_B1 Test adapter acc. to EN 55103-2, Fig. B1 MGA_B2 Calibration network acc. to EN 55103-2, Fig. B2 MGA_B4 Current transducer acc. to EN 55103-2, Fig. B4 MGA_HCS_100-60 Helmholtz coil 1-axis (50 khz) 1,00x1,00m, distance 0,60m MGA_HCS_125-75 Helmholtz coil 1-axis (50 khz) 1,25x1,25m, distance 0,75m MGA_HCST_50-28 Helmholtz coil 3-axis (50 khz) 0,5 x 0,5m, distance 0,28m MGA_HCS_50-28 Helmholtz coil 1-axis (50 khz) 0,5 x 0,5m, distance 0,28m MGA_CT-50A Coupling transformer acc. MIL-STD-461 CS 101 MGA_ISS-19 Coupling transformer for tests acc. DO160, Sec. 19 (19.3.1; 19.3.2; 19.3.3), in combination with MGA 1033 MGA_SO_CE101 Software plug-in MIL-STD-461E / CE101 MGA_SO_CS101 Software plug-in MIL-STD-461E / CS101 MGA_SO_CS109 Software plug-in MIL-STD-461E / CS109 MGA_SO_4-16 Software plug-in EN 61000-4-16 IEC / EN 61000-4 - 16 Immunity DC 150 khz PGA 1240-5 Power Generator DC 300 khz; +/-50V; +/-5A, also for the continuous disturbances acc. IEC 61000-4-16. PGA 1240-16 Power Generator DC 300 khz; +/-50V; +/-16 A PGA 1240-PSG 300 Option External voltage-source, input for phase-triggering of an external voltage-source, 50 ohm output, for the short-term tests up to 300V. Option instead of PGA 1330. PGA 1330 Immunity generator for short-term tests up to 300 V, with 50 ohm serial resistor to the output IT - 06 IT - 16 CN M2-AC-32 CN M2-DC-32 CN M3-AC-32 CN M3-DC-32 CN M4-AC-32 CN M5-AC-32 CN 1240-32 CN 1240-125 CN M2+M3-32-HV CN AF 2 CN AF 4 CN AF 4 CN AF 8 CN T 2 CN T 4 Isolation transformer 6 A Isolation transformer 16 A Coupling network for 2 lines 250 VAC, 15 Hz 150 khz Coupling network for 2 lines 250 VDC Coupling network for 3 lines 250 VAC, 15 Hz 150 khz Coupling network for 3 lines 250 VDC Coupling network for 4 lines 250 VAC, 15 Hz 150 khz Coupling network for 5 lines 250 VAC, 15 Hz 150 khz Coupling network switchable M2, M3, M4, M5, 32A, 250 V AC+DC, 15 Hz 150 khz Coupling network switchable M2, M3, M4, M5, 125A, 250 V AC+DC, 15 Hz 150 khz CN for 2 and 3 lines, 32A, 520 VAC / 620 VDC, Housing 4 HE CN for 2 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz CN for 4 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz with 4mm MC banana plugs CN for 8 unsymmetrical, unshielded lines, DC, 15 Hz 150 khz CN for 2 symmetrical, shielded data lines, DC, 15 Hz 150 khz CN for 4 symmetrical, shielded data lines, DC, 15 Hz 150 khz

CN T 8 CN for 8 symmetrical, shielded data lines, DC, 15 Hz 150 khz CN RJ 45 CN for unsymmetrical, unshielded RJ45, DC, 15 Hz 150 khz CN ITU-T CN acc. ITU - Fig.1/K 54, for Telecom lines IEC / EN 61000-4 - 11 and - 4-29 Voltage interruption and Voltage dips VIS 1700_1 Voltage interruption simulator according to IEC 61000-4-11, AC and DC ramp function, includes factory calibration VIS 1700_1 VIS 740 Step transformer 16,0 A for voltage dips, AC using only, 0%, 40%, 70%, 80% - necessary to reach the requirement acc. IEC 61000-4-11 (should also quote KAL VIS 740) KAL VIS 740 Additional cost for factory calibration of the step transformer. Before delivery of a new VIS 740, if a customer orders the VIS 1700_1 and VIS 740 RF - Power Amplifier PA 1020-25-250 RF broadband power amplifier, 25 W, 100 khz 250 MHz PA 1020-75-300 RF broadband power amplifier, 75 W, 100 khz 300 MHz PA 1020-75-400 RF broadband power amplifier, 75 W, 100 khz 400 MHz PA 1020-75-250 RF broadband power amplifier, 75 W, 10 khz 250 MHz PA 1020-180-400 RF broadband power amplifier, 180 W, 1 MHz 400 MHz FNN Chapter 3.7.1 Rules (Electricity Meters) PG01-2000 Pulse generator 0,1μs/2000μs, 10 kv acc. FNN rules IEEE 644 CAL 1250 Generator of magnetic fields with 3 channel generator / amplifier for calibration 50 / 60 Hz. Additions EMV-SOFT Control software (MS-Windows ) for Schloeder EMC generators (Burst, Surge, Voltage interruption, 3-phase coupling networks)