SCHOTT Shaped Fiber Rods

Similar documents
PURAVIS High Performance Shaped Fiber Rods

Clinical Diagnostics. Lighting and Imaging Solutions

Light Guide Overview

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

High Intensity LumiBright LE LED Light Engine

Understanding Optical Specifications

The absorption of the light may be intrinsic or extrinsic

Chapter 23. Mirrors and Lenses

Optical Components - Scanning Lenses

Chapter 23. Mirrors and Lenses

Notation for Mirrors and Lenses. Chapter 23. Types of Images for Mirrors and Lenses. More About Images

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Spherical Mirrors. Concave Mirror, Notation. Spherical Aberration. Image Formed by a Concave Mirror. Image Formed by a Concave Mirror 4/11/2014

Kit for building your own THz Time-Domain Spectrometer

Chapter 23. Mirrors and Lenses

STATIS and SANAO. Quality and Precision Handpieces

YOUNGS MODULUS BY UNIFORM & NON UNIFORM BENDING OF A BEAM

Fiber Pigtailed Pulsed Laser Diodes

PURAVIS. Eco-friendly glass optical fibers

GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS

Mirrors and Lenses. Images can be formed by reflection from mirrors. Images can be formed by refraction through lenses.

LumiBright TM LE 2400B-270

Design Guide: CNC Machining VERSION 3.4

Chapter 23. Light Geometric Optics

A thin foil optical strain gage based on silicon-on-insulator microresonators

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

High Speed Air Turbine Handpiece

Fiber Pigtailed Pulsed Laser Diodes

Test procedures Page: 1 of 5

LOS 1 LASER OPTICS SET

APPLICATIONS FOR TELECENTRIC LIGHTING

COMPACT Diode Laser System (Water-Cooled)

COM 46: ADVANCED COMMUNICATIONS jfm 07 FIBER OPTICS

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Screen-Tech the screen company

Geometric Tolerances & Dimensioning

Reinforced all-rubber HSS seals. Reliable protection for large size bearings

User manual. Handpieces. Micro-Suction. Suction-Pen. Usable with Sonoca 300/Sonoca 400 Required Softwareversion: Dok-ID: _R05

Speed of light E Introduction

PHYS 1020 LAB 7: LENSES AND OPTICS. Pre-Lab

Devices & Services Company

Calibration of reflectance standards for hemispherical geometry

Chapter 18 Optical Elements

Geltech Aspheric Lenses

Test Review # 8. Physics R: Form TR8.17A. Primary colors of light

STATIS and SANAO. Quality and Precision Handpieces

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

Light sources can be natural or artificial (man-made)

RMS roughness: < 1.5Å on plane surfaces and about 2Å on smoothly bended spherical surfaces

UV COBRA Slim Supplementary information

ROBAX Glass Ceramic Panels

always positive for virtual image

Multi-kW high-brightness fiber coupled diode laser based on two dimensional stacked tailored diode bars

Beamsplitter Product Specification

Moulded Optics standard aspheres

Home Lab 5 Refraction of Light

EUV Plasma Source with IR Power Recycling

Solution of Exercises Lecture Optical design with Zemax Part 6

2.2 Wavefront Sensor Design. Lauren H. Schatz, Oli Durney, Jared Males

Section 5 ISO Drawings ISO 10110

Typical Parts Made with These Processes

MANUFACTURING TECHNOLOGY

Where brightness and quality are essential for you Specialty light sources for medical and industrial applications

User Manual Laser distance sensor. series OWLE. Welotec GmbH Zum Hagenbach Laer Manual_OWLE _EN 1/20

ISO 1101 Geometrical product specifications (GPS) Geometrical tolerancing Tolerances of form, orientation, location and run-out

Designing for machining round holes

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

[MILLIMETERS] INCHES DIMENSIONS ARE IN:

Chapter 18: Fiber Optic and Laser Technology

Exp. No. 13 Measuring the runtime of light in the fiber

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

APPLICATION NOTE

4-Channel Optical Parallel Transceiver. Using 3-D Polymer Waveguide

Aspheric Lenses. Contact us for a Stock or Custom Quote Today! Edmund Optics BROCHURE

Chapter 23 Study Questions Name: Class:

Operating Light marled V16 / V16 D

L4 and L4i 915/940 nm Fiber- Coupled Lasers

Section IX: AF Series Fibers and Fiber Couplers

FCQ1064-APC 1064 nm 1x4 Narrowband Coupler. Mounted on

Chapter 25. Optical Instruments

CBT-90-UV-405 LEDs. CBT-90-UV-405 CBT-120 Product Datasheet. Features: Table of Contents. Applications

Bandpass Edge Dichroic Notch & More

Vanishing Core Fiber Spot Size Converter Interconnect (Polarizing or Polarization Maintaining)

Basics of Light Microscopy and Metallography

Lecture 8. Lecture 8. r 1

915/940 nm Fiber-Coupled Diode Lasers. L4S-Series

The Canadian Tire Paint Roller A Technical Description

Operating Light marled V10 LC / V10 LC D

Chapter 23. Geometrical Optics: Mirrors and Lenses and other Instruments

3 Light Fiber Products

CML s 7530 series Rigid Light Guide Applications Note

Image Formation by Lenses

Chapter Ray and Wave Optics

COPYRIGHT 2013 LED ENGIN. ALL RIGHTS RESERVED. LZ1-00R500 (1.0 08/23/13)

Test Review # 9. Physics R: Form TR9.15A. Primary colors of light

Elite Series. Available in custom ordered lengths or 5, 10, 20 and 50 foot rolls* Description. Features C US LISTED.

High Luminous Efficacy RGB LED Emitter LZ4-00MC00. Key Features. Typical Applications. Description

Geometrical Optics. Have you ever entered an unfamiliar room in which one wall was covered with a

3B SCIENTIFIC PHYSICS

Image Formation. Light from distant things. Geometrical optics. Pinhole camera. Chapter 36

Transcription:

SCHOTT Shaped Fiber Rods Precisely Shaped Illumination for Dental Handpieces Examples of end configurations of shaped fiber rods High transmission and high numerical aperture in combination with excellent forming properties enable SCHOTT s shaped fiber rods to be the first choice in dental handpiece illumination. The shaped fiber optic rods replace short length flexible fiber optic components due to their advantage of no fiber breakage and easy assembly into dental handpieces without complicated adjustments. Consisting of a plurality of core/clad systems fused together to a multi core component, the Multi Core Rod type features excellent forming properties. Heating the raw rod up to the softening temperature makes it possible to shape complex 2D and 3D geometries according to customer specifications. The shaping process utilizes a mold which ensures highly uniform manufacturing output while maintaining precisely specified dimensions and tolerances. Final quality inspection by an automated optical inspection system further supports the high level of quality of the delivered components. Excellent mechanical as well as chemical stability facilitates a long lifetime and reliable functionality of the shaped fiber rod. Technical Data Description (FST-K3) Applications Dental handpieces Core Type Color of Outter Clad Multi Clear Numerical Aperture.63 Eff. Acceptance Angle according to DIN 58 141 Part 3 Theoretical ( = 587. 6 mm) 78 Dental drillers Dental scalers Dental spray units Lead-free Biocompatibility According to DIN ISO 1993-5 Temperature Operational (glass rod only) Storage/transport Shelf Life According to IEC 6721 Part 3-1 (Class: 1K2, 1B1, 1C1, 1S2) Yes Yes - 2 C/-4 F +35 C/158 F - 2 C/-4 F + 7 C/662 F min. 2 years

Typical Spectral Transmission MCR -3 Numerical Aperture The numerical aperture or respectively the acceptance angle of the basic rod is calculated by the ratio of the refractive indices of core and cladding. For the material the theoretical numerical aperture is.63, which results in a full acceptance angle of 78. The numerical aperture of the shaped fiber rod is influenced by the design of the rod, in particular bends, angles, and transformations of the cross section will influence the final aperture of the rod. Due to plurality of different influences the aperture cannot be predetermined, but needs to be evaluated in the final shaped rod. When further processed into the final shape the transmission may change, depending on the geometrical transformation. Further processing steps can be: cone shaping bending shaping into complex shapes end surface not perpendicular to axis of the rod Transmission The above displayed transmission curve represents SCHOTT s typical manufacturing level for rods. The transmission is controlled in the wavelength range between 46 and 66 nm. The following conditions influence the transmission of a fiber optic component: Transmission of core glass Core/clad surface ratio (maximum for single core) Quality of end polish Length: negligible for rigid fiber optics, due to short application length Sharp bends (light leakage)

max. Deflection [mm] Mechanical Strength of Shaped Rods Fire-polished rods have the original surface condition resulting from the initial rod drawing process. Diameter tolerances of the unprocessed rod are in the range of ±.3 mm. This raw material tolerance will change during the shaping process. Fire-polished round rods feature the highest breaking resistance with slightly better deflection than rounded rods. For higher requirements concerning mechanical tolerances the originally fire-polished rods can be rounded. These rods feature an improved diameter tolerance by mechanically grinding the outer diameter of the unprocessed rod to precise dimensions up to +/-.2 mm. This raw material tolerance will change during the shaping process. Since the common outer cladding is partially removed by the process, the breaking load resistance, as well as deflection, is lower in comparison to fire-polished rods. Shaped rods show different mechanical strength in comparison to the original round rods depending on the individual shapes and bends of the component. As an example the breaking load resistance of a kidney-shaped, straight rod is shown. The force has been applied to the concave side. The breaking load resistance is lower than for a round rod, but maximum deflection is significantly higher. Mechanical Strength Measurements Breaking Load F B [N] 12 1 8 6 4 2 Breaking Load Deflection,8,7,6,5,4,3,2,1 Firepolished Rods Rounded Rods Shaped Rods Cross section: straight sample F Mechanical Strength of Shaped Rods Test Conditions: 3 Point Bending Test F [N] Sample geometry No. of samples Starting force Feed rate 2.5 mm for round rods 3.95 * 1.3 mm for kidney shape 1 2 per type 5 N 2 mm/minute d = 3 mm

Design Guidelines for Shaped Rods Design examples SCHOTT s shaping process enables a variety of different shapes and cross-sections to be realized. The original circular shape of the basic rod can be transformed into flat, half-round or kidney-shaped designs. The straight rod can be angled in different shapes, realizing 2D as well as 3D configurations. Thus, the shape of the rod can be custom-tailored to the space requirements in the customer s application. Quality Inspection The precise dimensions of the shaped rods can be verified by an optical inspection system. Since all dimensions, except the overall length, are defined by the molding process, final process validation usually makes a 1% control of the finished fiber rods redundant. Some dimensions, i. e. angles or bends cannot be measured on the final rod, since reference edges are not accessible. In this case check dimensions will be agreed upon (see check dimension ZZ in the design guidelines below). Design Details Some basic values of dimensions and tolerances are listed in the table, as well as in the principle sketches of a shaped rod below. The design guidelines can only give a brief overview about general tolerances and angles, which can be realized. A combination of different requirements may result in variations basic numbers in the table below, which need to be agreed upon by the SCHOTT engineering department Design Details Light Input End The light input end usually maintains a round shape to gather as much light as possible from the light source, usually a small footprint halogen bulb or a light emitting diode - LED. The maximum diameter of a shaped fiber rod is 3. mm. If the light path needs to be split into 2 arms, two half-round rods can be combined to a full circle. Light Output End The light output ends can have different shapes depending on the requirements. Round, flat or kidney-shapes are common, usually with a sharp bend right before the end surface Diameter Tolerances The tolerances of specified diameters depend on the shape of the component. In bent sections the outer diameters are slightly larger than the diameter of the basic rod, due to material bulging slightly sideways. Angles The shaping process allows the fiber rods to be bent in narrow bend radii. Standard values are ± 1. Depending on the overall design smaller bend radii down to ±.5 mm are also possible. Metal Ferrules If required, metal ferrules can be attached to the final rod according to customer specifications.

Design Guidelines for Shaped Fiber Rods Characteristics Recommendation Comment Diameter of basic rod before shaping 1. 3. mm Reference view B Diameter tolerance of shaped rod in round section Fire-polished: ±.5 mm Rounded: ±.3 mm Reference view B Diameter tolerance of shaped rod in bent sections Width: approx..2 mm larger than maximum nominal diameter Height ±.5 mm Reference range C Minimum bending radii Bending angle tolerance Standard: 2.mm Optional: 1.mm Standard: ± 1 Optional: ±.5 Informal dimension only Informal dimension only Installation height bend to light output tolerance ±.7 mm Reference length ZZ Length ZZ is check dimension Straight length between bend and light output area Length 1. mm Reference length YY Cross-sectional shape at light output Standard: round, half-round, oval/flat Optional: kidney shape See picture above for reference Cross-section at light output Should be perpendicular to the axis of the rod Non-perpendicular cross-sections bear a high risk of chipped edges. In addition, the NA of the rod changes. Tolerances at light output Width ±.15 mm Height ±.5 mm Reference view A Overall length of shaped rod 3 mm 15 mm Reference length XX Overall length tolerance ±.15 mm Reference length XX

rel. Transmission [%] rel. Transmission [%] Chemical Resistance of Shaped Rods rods feature excellent chemical resistance. Core and cladding glasses have high chemical resistance classes, which ensure long-term stability over their lifetime under repeated reprocessing cycles. Resistance validated by optical measurement of relative transmission Measured in accordance with DIN 58 141 Part 2 Aperture of light beam:.1 Measurement wavelength: = 535 nm Prior to optical measurement cleaning of end surface with cloth and ethanol Autoclaving tests performed with un-mounted glass rods Thermal Disinfection Resistance Thermal Disinfection Resistance Test Conditions 1 Unit Miele Disinfector Automatic G7735 8 6 Cleaning program Simulation Standard program Sesin 95 C-1 4 2 Detergent Neodisher MA Dental, 3 ml dil. in 1 L Water 1 2 3 4 5 Number of Cycles Regeneration Neodisher Mielclear Autoclave Durability Autoclave Durability Test Conditions 1 8 Autoclave Standard laboratory autoclave 6 4 Autoclaving program 134 C, 1 min. sterilization time, 4 min. cycle time 2 2 4 6 8 1 Number of Cycles All specifications are subject to change without prior notice. This datasheet or any extracts thereof may only be used in other publications with express permission of SCHOTT. SCHOTT North America, Inc. Lighting and Imaging SCHOTT North America, Inc. 122 Charlton Street Southbridge, MA 155 USA Phone: +1 (58) 765-9744 Fax: +1 (58) 765-1299 lightingimaging@us.schott.com www.us.schott.com/lightingimaging