Electronic Air / Fuel Ratio Control System

Similar documents
Universal Controller

ASZ... Potentiometers. Siemens Building Technologies HVAC Products. ASZxx.7xx or ASZxx.8xx

ASZ... Potentiometers. Building Technologies HVAC Products. ASZxx.3x

SQN7... Actuators. Building Technologies HVAC Products

Actuators SQN7... Siemens Building Technologies HVAC Products. for air dampers and control valves of oil or gas burners

Room Temperature Controllers. for heating and cooling systems

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Room Temperature Controllers. for heating and cooling systems

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Room Temperature Controllers. for heating and cooling systems

Configured air damper actuators 6FU11xx-xDxxx-xxxx

RS /M MZ SERIES

EY-EM 527: Remote I/O module, ecolink527

Operating Instruction

Functional data Factory settings Variable Settings

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Power consumption Operation At rest Wire sizing

Electromotoric actuators

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Overcurrent Protection / 7SJ45

XUA1 - AC Voltage and phase balance relay

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Analog amplifier RA. RE Edition: Replaces:

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

KS 40-1 burner Universal Burner Controller

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Rotary actuators for ball valves

EY-EM 522, 523: Remote I/O module, ecolink522, 523

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

AC 01.2 HART Technical data Actuator controls

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Rotary actuators for ball valves

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Self-learning Room Temperature Controller Receiver

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Outside Temperature Sensors

Spring Return DuraDrive Proportional Actuator

3B SCIENTIFIC PHYSICS

XF2 Frequency Relay. Manual XF2 (Revision A)

Phase sequence and phase failure monitor

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Electronic Thermostat TE-1 Version according to EN

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Drive Electronics pq11

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Electromotoric actuators for stroke valves

Rotary actuators for ball valves

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Power consumption In operation At rest For wire sizing

658 Current to Position Converters

XP2-R Power and Reverse Power Relay

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Valve amplifier for proportional pressure valves

Inductive sensor slot-type SI2-K08-AP7

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data sheet. Technical data. Safety notes

Instruction Manual for Digital Grounding Resistance Meter

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

s Climatix extension module 26 I/Os POL985.00/XXX

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Differential pressure sensors

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

PHOENIX CONTACT - 09/2009

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Power consumption In operation At rest For wire sizing

Overview of types. Technical data

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Technical data. Parameterisable damper actuator in the

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Process displays For standard signals, temperature, resistance measurement

HAWK5000 Operators Manual

Power consumption In operation At rest For wire sizing

Miniature resistance thermometer Model TR33, thread-mounted

Technical data. Safety notes

Impulse system MPT 700. Manual Edition GB

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

3B SCIENTIFIC PHYSICS

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Operating instructions Fail-safe delay timer AZS About this document. Content

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Transcription:

7 871 ISO 9001 Electronic Air / Fuel Ratio Control System RVW20... Electronic control unit - for use with modulating single- and dual-fuel burners - with extended functionality for mechanical air / fuel ratio control The RVW20... and this Data Sheet are intended for use by OEs which integrate the control system in their products! Use -dependent control of the burner s air damper the fuel valves an additional actuator Suited for use in connection with O2 trim control RPO25... Optimum and efficient burner operation 24.10.2001 HVAC Products

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! Do not open, interfere with or modify the unit! Before performing any wiring changes in the connection area of the RVW20, completely isolate the unit from the mains supply (all-polar disconnection) Ensure protection against electric shock hazard by providing adequate protection for the terminals Check wiring and all safety functions To warrant protection against electric shock hazard, ensure that AC 230 V mains voltage is strictly separated from extra low voltage Engineering notes For additional information, especially on commissioning, refer to Basic Documentation P7871.2 The following types of burner controls can be used in connection with the RVW20...: LAL..., LFL..., LEC..., LGK16... and LOK16... ounting notes Ensure that the relevant national safety regulations are complied with After commissioning, check the flue gas values The RVW20... is designed for flush panel mounting with housing ARG61.010 wall mounting with housing ARG61.040: fitting the screw terminal base to the subassembly terminal 32 at the top terminal 2 at the bottom wiring to be made according to the plant connection diagram Installation notes Installation work must be carried out by qualified staff Prior to startup, check wiring and parameter settings carefully Commissioning notes Commissioning and maintenance work must be carried out by qualified staff After commissioning, check the flue gas values Disposal notes The unit contains electrical and electronic components and may not be disposed of together with household garbage. Local and currently valid legislation must be observed. 2/10

echanical design RVW20... Insert of plug-in design with European standard printed circuit boards 2 x 32-pin DIN connectors exchangeable relay board for controlling the actuators Supplied without housing Located on the front of the unit are: - LED 1 for fuel 1 - LED 2 for fuel 2-7-segment display (3 digits) for operating phases, burner output and fault indication Housing ARG61.0X0 ade of impact-proof plastic With a transparent cover To be ordered as a separate item (refer to «Ordering») Ordering Air / fuel ratio control unit - With data storage module RZD20 plugged in RVW20.000E27 Air / fuel ratio control unit RVW20.001E27 - For fuel changeover in operation and correcting variable authority of 50 % - With data storage module RZD20 plugged in Housings - For flush panel mounting, complete with ARG61.010 connection terminals and cover - For wall mounting, complete with ARG61.040 connection terminals and cover Accessories Handheld terminal - Complete with cable KF8859 (2 m) - For setting the parameters - For fault detection - For troubleshooting Separate cable for handheld terminal (20 m) AZW20.20 KF8860 Data storage module (2 pieces in one package (backup data carrier)) RZD20 Relay board 4 668 9846 0 - Exchangeable - Plug-in design Conductive plastic potentiometers for actuators refer to Data Sheet 7921 3/10

Technical data ains voltage AC 230 V ±15 % ains frequency 50 Hz ±6 % Power consumption 25 VA Plug-in system design D to DIN 41 612 Dimensions of RVW20... board 100 x 160 mm Connection terminals for 2 x 1.5 mm ² or 1 x 2.5 mm ² ounting position optional Safety class II to IEC 730-1 Degree of protection of housing - Front - Base Weight - With housing - Without housing IP 42 to IEC 529 IP 10 to IEC 529 approx. 1.4 kg approx. 0.75 kg Switching capacity of terminals L-Q1 - Current Switching capacity of terminals Q4-Q5 / H - Current at AC 230 V - Current at AC 24 V Extra low voltage inputs Hum voltage Terminals B1...B4 - Impedance Conductive plastic potentiometers - Resistance - Angular rotation - Refer to Data Sheet 7921 ing signal X3 - Internal resistance Switching capacity of control outputs Y1...Y6 - Current - Number of switching cycles at AC 230 V ±15 % 0.005...2 A AC 24...265 V 0.005...2 A 0.02...2 A max. AC 50 mv (50 Hz) 100 kω 1 kω 90...135 470 Ω Terminals +5 V - Amperage 1 ma Extra low voltage outputs terminal U10 - Current (all terminals) Terminals X2, U1 - Impedance AC 230 V ±15 % max. 5...150 ma eff. cos ϕ = 0.6: 13 x 10 6 cos ϕ = 0.8: 18.8 x 10 6 cos ϕ = 1: 20 x 10 6 DC 10 V max. 50 ma 25 kω 4/10

Control outputs Q2, Q3, Y10, Y20, F1, F2 on off - Current on signal X1 - Internal resistance AC 187...265 V < AC 50 V < 1 ma 100 Ω Environmental conditions Transport Climatic conditions echanical conditions Temperature range Humidity Operation Climatic conditions echanical conditions Temperature range Humidity IEC 721-3-2 class 2K2 class 22-25...+70 C < 95 % r.h. IEC 721-3-3 class 3K5 class 32 0...60 C < 95 % r.h. Condensation, formation of ice and ingress of water are not permitted! CE conformity According to the directives of the European Union Electromagnetic compatibility EC 89 / 336 EEC incl. 92 / 31 EEC Directive for gas appliances 90 / 396 EEC (level to EN 298) 5/10

Function General Parameter settings Supervision and display Startup Controlled operation Shutdown Correcting signal Compensation of hysteresis The RVW20... controls the actuators depending on the positioning signals delivered by the load controller according to curves whose parameters can be set for each type of fuel synchronously With the help of the handheld terminal AZW20.20 (to be ordered as a separate item) Setting the parameters of the setpoint curves Setting other plant parameters 3 channels For 2, 3 or 4 actuators Each with 2 setpoint curves, with a maximum of 17 breakpoints Can be parameterized and stored in nonvolatile memory: Ignition position -specific operating positions Other parameters Using the data storage module RZD20, the values can be transferred to other RVW20... If inadmissible operating states or system faults occur, the burner will be shut down During startup and shutdown, the RVW20... shows operating phases 0...9 on the display (during operation, the burner s output is displayed as a percentage) Faults are indicated by a flashing 2-digit code Burner startup is controlled by the burner control The RVW20... identifies the startup sequence during the startup phase, based on valve and fan control; the actuators are controlled accordingly checks the correct functioning of the connected components during the startup sequence runs to the parameterized ignition position to enable startup runs to the parameterized low-fire position after ignition After reaching the operating position, the burner control will enable the load controller The load controller controls the burner s output via the RVW20... The positions of the actuators will be reached based on the required burner output based on the selected type of fuel with the help of the parameterized setpoint curves The RVW20... drives the actuators to the calculated target positions The RVW20... drives the actuators to their start positions after burner shutdown on completion of the postpurge time, if scheduled Changes to the combustion parameters (e.g. density of air or quality of fuel) can be offset by connecting O2 trim control RPO25... to the input for the correcting signal the authority of the correcting variable can be parameterized The RVW20... offsets mechanical play between actuator and controlling element The authority of compensation of the hysteresis can be parameterized 6/10

Basic diagram RVW20 AIR1 Y1 X2 X2' ' AIR2 Y2 P AIR B1 FUEL1 B2 FUEL1 X1 FUEL2 Y3 Y4 P P B3 Fuel 1 FUEL2 U1 AUX1 FS Fuel 2 LR Y10 Y20 Integrator AUX2 Y5 Y6 P AUX B4 Programming Fuel select F1 F2 Q3 Q2 Control Q1 Q4 Q5 H 7871a06/0801 AZW20.20 FS FA Legend AIR Setpoint curves of the air damper actuators FUEL Setpoint curves of the fuel actuator AUX Setpoint curves of the auxiliary actuators H... Terminal markings (refer to «Connection diagram») B... Terminal markings (refer to «Connection diagram») LR controller F... Terminal markings (refer to «Connection diagram») Fan motor FA Burner control P Potentiometer FS Fuel selector Q...Y Terminal markings (refer to «Connection diagram») 7/10

Sequence diagram Phase 0 1 2 3 4 5 6 7 R 8 9 0 BETRIEB lim1 lim5 t4 SERVICE lim8 STOP STOP OPERATION Q3 G Q2 Y10 1) 5) 7) R Y20 1) 5) 5) 7) R Q1 Quit Q4-Q5 Ready Y1,Y3,Y5 Y2,Y4,Y6 SA SA X1 (0...10 V) 2) 4) 5) Burner 3) 2) Output A ax IgnPos 6) SA1 (AIR) in IgnitLo Z SA4 (AUX) A ax in IgnitLo 6) SA2 (FUEL1) SA3 (FUEL2) Z 7871d02/0801 Legend Signal must be present or output is under voltage 1) Signals at«y10» or «Y20» only act on output «X1» Signal may not be present or output is dead 2) Output «X1» gives the current air damper position 3) Output «X1» gives the current burner output Signal can be present 4) Output «X1» changes according to signals «Y10» Controlled output and «Y20» Prerequisite for changing to the next phase 5) Signals at «Y10» or «Y20» have no impact Phase Parameter setting phase 6) If ignition load «IgnitLo» is set to a level above the minimum burner output, the ignition load will be AIR Setpoint curves of the air damper actuators approached in phase 7 AUX Setpoint curves of the auxiliary actuators 7) Optionally «Y10 / Y20» or analog signal at «U1» for AZW... Handheld terminal controlled operation FA Burner control FS Fuel selector lim... Duration of phase is limited. If the sequence does not FUEL Setpoint curves of the fuel actuator change by the time the set period has elapsed, the unit will LR controller initiate lockout Fan motor lim1 = 30 s P Potentiometer lim5 = 75 s Q...Y Terminal markings (refer to «Connection diagram») lim8 = 30 s SA Actuators t4 Interval 8/10

Connection terminals ains voltage side Extra low voltage side Q5 Q4 +5 V H Y6 Q3 Y5 Y10 Y20 N Q2 Q1 Y4 Y3 F1 Y2 F2 Y1 N N L L X1 U1 U10 B4 U10 B2 X2 U10 B3 U10 B1 7871a03/0901 Legend Terminal Input / Voltage Description output B1 I Feedback signal air damper actuator B2 I Potentiometer (wiper) fuel actuator (Fuel 1) B3 I Potentiometer (wiper) second fuel actuator (Fuel 2) B4 I Potentiometer (wiper) auxiliary actuator (AUX) F1 I AC 230 V Selection of fuel: fuel 1 F2 I AC 230 V Selection of fuel: fuel 2 L I AC 230 V Live for internal power supply, actuator outputs and «Q1» --- --- Reference potential for all low voltage inputs / outputs and for screening (all -terminals are internally interconnected) N I --- Neutral conductor for internal power supply, reference potential for the mains voltage inputs (all N-terminals are internally interconnected) Q1 O AC 230 V Acknowledge signal: indicates when certain actuator positions are reached Q2 I AC 230 V Signal from the burner control: first fuel valve on / off Q3 I AC 230 V Signal from the burner control: fan on / off Q4-Q5 / H O Potentialfree Readiness contact or nonreadiness / control loop: indicates when the RVW20... is ready to operate U1 I Signal input for analog burner output control U10 O DC 10 V Power supply for the potentiometers (all «U10» terminals are internally interconnected) X1 O Burner load signal X2 I Correcting signal of O2 trim control RPO25... Y1 O AC 230 V ing signal (open) (3-position control of actuators) Y2 O AC 230 V ing signal (closed) (3-position control of actuators) Y3 O AC 230 V ing signal (open) (3-position control of actuators) Y4 O AC 230 V ing signal (closed) (3-position control of actuators) Y5 O AC 230 V ing signal (open) (3-position control of actuators) Y6 O AC 230 V ing signal (closed) (3-position control of actuators) Y10 I AC 230 V Signal for increasing the burner s output (from the 3-position controller) Y20 I AC 230 V Signal for decreasing the burner s output (from the 3-position controller) +5 V O DC 5 V Auxiliary voltage, max. 1 ma 9/10

Dimensions Dimensions in mm Housing ARG61.040 for wall mounting Housing ARG61.010 for flush panel mounting 7871m03/0598 10/10 2001 AG Subject to change