Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009

Similar documents
Operating instructions Contrast sensor O5K / / 2016

Operating instructions optical fork sensor OPU200 OPU200 / / 2018

Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

Operating instructions Measured signal converter for temperature sensors TP / / 2010

Operating instructions Electronic level sensor LK31xx

Operating instructions Temperature transmitters. TA2xxx / / 2015

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

Operating instructions Electronic level sensor LK / / 2008

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Operating instructions Magnetic-inductive flow meter SM6050 SM7050 SM / / 2016

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Operating instructions Flow sensor SAxx00 SAxx10 SAxx30 SAxx40

Operating instructions. Combined pressure sensor PN /00 11/03

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

laser sensors through-beam sensor switching output / analog output high precision repeatability

in one housing (3). The light beam is reflected by a reflector (4). The objects are detected by interruption of the light beam.

Operating instructions. Electronic pressure sensor PY2068 ENGLISH

Original operating instructions Fail-safe inductive sensor GM705S

Installation Instructions RF-identification system Read/write head ANT513

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

QL55 Series Luminescence Sensor

PICO-AMP Miniature Remote Sensing System

Operating instructions PMD 3D sensor. O3D2xx /02 04 / 2015

MLV40 Series Miniature Sensors

Original operating instructions Fail-safe inductive sensor GG507S

Operating instructions Electronic level sensor LR / / 2012

QL50 Luminescence Sensor

Operating instructions Magnetic-inductive flow meter FMM FMM

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Contrast scanners detect the little differences

Photoelectric Sensors XUV Sensors with Separate Optical Heads

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Info card. Ultrasonic sensors

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

Operating instructions. RFID UHF reader DTE800 DTE810 DTE900 DTE910 DTE / / 2017

Optical laser distance sensors. Dimensioned drawing

USi Product Presentation. Mayser Ultrasonic Industrial Sensor USi

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

SS-A5 SERIES SH SERIES

Amplifier-separated Manual Sensitivity Setting Photoelectric Sensor

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Installation Instructions RF identification system Read/write head ANT430 ANT431

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Optical laser distance sensors. Dimensioned drawing

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568

Operating instructions Electronic pressure sensor. PF205x /00 06/2011

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Operating instructions Electronic level sensor LR / / 2016

Torque Sensor Series 3000 and Series 4000

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

General-Purpose Photoelectric Sensor

Strain Gauge Measuring Amplifier BA 662

Color Detection Fiber Sensor FZ-10 SERIES. Reliable and precise color discrimination. Red, green and blue LEDs. Easy set up

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

SLE30 Expert Series Teach-Mode Slot Sensor

Seite 2 Standard-Empfänger. EN Operation Instructions

Distance sensors. System description. Distance measurement using triangulation

Repair Instructions. Replacing a La Z Time Mechanism Side Subassembly. Remove the Back(s): Remove the Mechanism Assembly: CAUTION.

Laser light scanner with background suppression. Dimensioned drawing

Twin adjuster enables delicate sensitivity setting

Remote Sensor Amplifier Terminal

Pulse Scaler for DIN Rail Attachment

Operating instructions Electronic level sensor LR / / 2016

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Electrical connection

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Operating instructions Electronic level sensor LR / / 2012

Distance-setting Photoelectric Sensor

Universal Voltage Cabled Photoelectric E3JK

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Operating Instructions

Long Range Metal Body Sensor

MLV12 Series Dura-Vue TM Sensors

Absolute Encoders Singleturn

Customized HP100 Sensors. HP300 Series. Customized to solve difficult application problems

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.

Distance-setting Photoelectric Sensor

Leuze electronic. 3 Series. Product description

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

3B SCIENTIFIC PHYSICS

PULSE/FREQUENCY/CONDITIONER USER GUIDE

Technical data. General specifications. Transducer frequency Indicators/operating means

Absolute Encoders Multiturn

Technical data. General specifications. Transducer frequency Indicators/operating means

MULTI-BEAM LS10 Light Screen System

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

REMOTE SENSOR SERIES. Description

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Type Nominal voltage (V) Code HSV V

Ultraminiature Photoelectric Switches with Self-contained Amplifier

PHOTOELECTRIC SENSORS. Online data sheet

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Operating instructions Electronic level sensor LR / / 2016

Transcription:

Operating instructions Switching amplifier for fibre optics OBF5xx 704513 / 00 04 / 009

Contents 1 Preliminary note...3 1.1 Symbols used...3 Functions and features...3.1 Applications...3 3 Installation...3 3.1 Attaching the fibre optics...4 4 Electrical connection...5 5 Operating and display elements...6 6 Set-up...6 7 Settings...7 7.1 Automatic setting of the sensitivity...7 7.1.1 The sensor is to switch when the object is detected...7 7.1. The sensor is not to switch when the object is detected...8 7.1.3 Measured value difference too small...8 7. Manual setting of the sensitivity...8 7.3 Setting of maximum sensitivity...9 7.4 Setting of the pulse stretching...10 7.5 Electronic lock... 11 8 Operation... 11 8.1 Set-up... 11 8. Fault indications...1 9 Maintenance, repair, disposal...1

1 1.1 Preliminary note Symbols used Instruction > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunctions or interference. Information Supplementary note. Functions and features The switching amplifier detects objects and materials without contact and indicates their presence by a switching signal..1 Applications Only for use with ifm fibre optics type FE-11 and FT-11. The range is determined by the fibre optics. Pulse stretching, adjustable 0 or 1... 90 ms. Each input pulse is stretched to the set value. 3 Installation Hook the unit into the DIN rail (1) and clip it into place () or fix it by means of a mounting fixture. 1 3 A Removal Lever out the mounting clip (A) with a screwdriver (3) and remove the unit. 3

3.1 Attaching the fibre optics 1 Loosen the screw (A). Push the fibre optics into the sensor holes (B) until you feel a slight resistance (O-ring). 3 Push the fibre optics until the end stop (optic elements) and hold them. 4 Tighten the screw (A). If the fibre optics are not in contact with the optic elements, the sensing range is reduced. 4

4 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply according to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: Automatic PNP / NPN detection M8 M8 M1 Cable Core colours: BN (brown), BU (blue), BK (black), VT (violet). On power up, the unit detects automatically if the switching output is connected to L- (= PNP) or to L+ (= NPN). The polarity of the function check output is set according to the polarity of the switching output. Both outputs must be connected with the same polarity: PNP or NPN! 5

5 Operating and display elements 1: Row of LEDs (4 x LED green 1 x LED red) Excess gain in % Input signal strength Pulse stretching in ms : Programming button [OUT on] Automatic setting "OUT on" Manual setting "+" Pulse stretching "+" 1 3: LED yellow Switching status 3 4 LED green Operating status 4 5: Programming button [OUT off] Automatic setting "OUT off" Manual setting "-" Pulse stretching "-" 5 6 Set-up Diffuse reflection optics (FT-11) For operation as diffuse reflection sensor, the light-on mode with maximum sensitivity is set on delivery. Through-beam optics (FE-11) For operation as through-beam sensor, the light-on mode with maximum sensitivity is set on delivery. Carry out the automatic setting of the sensitivity to determine the light-on / dark-on mode 7.1 Automatic setting of the sensitivity. 6

7 Settings 7.1 Automatic setting of the sensitivity 7.1.1 The sensor is to switch when the object is detected Diffuse reflection optics (FT-11) Position the object. 1 Press [OUT on] for > s to < 6 s. >> The sensitivity is set to the object. >> The green LED lights, the yellow LED flashes x. Remove the object. Press [OUT off]. >> The sensitivity is set without object. >> The green LED lights, the yellow LED indicates the switching status. >> The programming is finished. Through-beam optics (FE-11) Position the object. 1 transmitter Press [OUT on] for > s to < 6 s. >> The sensitivity is set to the object. >> The green LED lights, the yellow LED flashes x. receiver 7

Remove the object. transmitter Press [OUT off]. > The sensitivity is set without object. > The green LED lights, the yellow LED indicates the switching status. > The programming is finished. receiver 7.1. The sensor is not to switch when the object is detected Position the object (see figure 1) and press [OUT off]. Remove the object (see figure ) and press [OUT on]. The settings can also be carried out first without object (step 1) and then with object (step ). Timeout If no button is pressed for 15 min during the setting procedure, the unit changes to the normal operating mode with unchanged values. 7.1.3 Measured value difference too small If the measured value difference is too small, the switching threshold can be manually adjusted. > The unit changes to the manual setting mode. 7. Manual setting of the sensitivity / step. 7. Manual setting of the sensitivity Carry out the automatic setting prior to the manual setting to determine the light-on / dark-on mode. Diffuse reflection optics (FT-11) / through-beam optics (FE-11) Press [OUT off] for > 6 s to < 0 s. out on 1 % 400 00 150 100 50 > The green LED flashes with Hz, the yellow LED indicates the switching status. > The row of LEDs indicates the input signal strength and flashes to indicate the switching threshold. 8

Modify the switching threshold Press [OUT off] to reduce the switching threshold. Press [OUT on] to increase the switching threshold. --Fast forward by keeping the button pressed. 3 Exit setting Press [OUT on] + [OUT off] simultaneously. >> The unit changes to the normal operating mode. 4 Check the safe switching function. If necessary, repeat the setting ( step 1). Timeout If no button is pressed for 15 min during the setting procedure, the unit changes to the normal operating mode with unchanged values. 7.3 Setting of maximum sensitivity Align the fibre optics so that no light is received. The sensor is to switch when light is received First press [OUT on], then [OUT off]. The sensor is to switch when no light is received First press [OUT off], then [OUT on]. 9

7.4 Setting of the pulse stretching The length of the output signal can be adjusted. If the object does not stay in the detection zone long enough, it is possible to stretch the pulse time. 1 3 Press [OUT on] for > 6 s to < 0 s. >> The green LED flashes with 4 Hz, the yellow LED indicates the switching status. >> The row of LEDs indicates the pulse stretching. Set the pulse stretching time. Press [OUT off] to reduce the pulse stretching time. Press [OUT on] to increase the pulse stretching time. --1 push on the button corresponds to 1 ms. --Fast forward by keeping the button pressed. Exit setting Press [OUT on] + [OUT off] simultaneously. >> The unit changes to the normal operating mode. 0 1-10 11-0 1-30 31-40 41-50 51-60 61-70 71-80 81-90 time (ms) lighting LEDs 10

Timeout If no button is pressed for 15 min during the setting procedure, the unit changes to the normal operating mode. 7.5 Electronic lock The unit can be locked electronically to prevent unauthorised setting. On delivery the unit is not locked. Locking / unlocking Press [OUT on] and [OUT off] simultaneously for 10 s. >> Acknowledgement is indicated by a change of the status of the yellow LED. >> The unit is locked. To unlock repeat this step. 8 8.1 Operation Set-up After installation, electrical connection and parameter setting, check whether the unit operates correctly. >> Display by LEDs. The red LED lights and the output FC "function check output" is switched in case of a detection problem (insufficient object recognition, maladjustment, soiling of the lens). After rectification of the fault and several successful switching operations, the function check output is automatically switched off. 11

8. Fault indications Display Cause LED yellow flashes at Hz. LED green is off. Row of LEDs is off. Internal fault LED yellow flashes at 8 Hz. Green LED is lit. Row of LEDs is off. Timeout: Max. Programming time of 15 min. exceeded. Change to the normal operating mode. 9 Maintenance, repair, disposal Faulty sensors must only be repaired by the manufacturer. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. Technical data and further information at www.ifm.com Select your country Data sheet direct: 1

13