GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Similar documents
Ø560*336mm 4.25 kg 2100 ± 105m

Ø 1250 * 688 mm 93 kg ± 105m

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Single-Armored Cables, Fibers

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

Outdoor, Fig 8 Armored, Multi Tube

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Outdoor, CCTV or CCTV, Fig 8 Armored.

Optical Systems Contents

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

features and benefits

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Fibre Optic Indoor/Outdoor Cable

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Outside Plant All Dielectric

Standard Monotube SAFE

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Fiber Optic Outside Plant Cables (4-144 Fibers)

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Exhibit A Construction Project Manual and Drawings

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

SPECIFICATION. Optical Fiber Cable

u n a B Optical Cables UNIFLEX CABLES LTD.

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

Datasheet Outside Plant Cable

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

COPPER + LWL RAW CABLES

Information technology. Generic cabling systems, General requirements

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

Data, Network and Bus Technology

Integrating Global Communications...

Industrial Automation

Z EE E E Z E Z Z Z Z Z

FiberHome Fiber Products

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

OFS AllWave non-dispersion shifted single-mode optical fiber

Type QG-G50-2C- M-BU

FTTH Fiber Optical Cable

There are lots of problems or challenges with fiber, Attenuation, Reflections, Dispersion and so on. So here we will look at these problems.

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Connection technology for wireless communication systems

Category 6 A F/FTP Euroclass C ca Cables

Electric cables. Cranes

14 AWG 2 AWG: 600 Volt

Medium Voltage Power Cables

NETWORK CONNECTIVITY SYSTEMS

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

Category 6 UTP EuroClass C ca Cables

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Multi Fiber Cable Assemblies

DESIGNING AND DEPLOYING SPECIAL MULTI FUNCTION FIBER OPTIC CABLES

Why Using Fiber for transmission

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Migration to 50/125 µm in the Local Area Network

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

kv: medium voltage reeling cable with fibreoptics

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Technical specification SiMTaCS Single Mode Tactical Cable System

Fiber Optic Principles. Oct-09 1

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

Faster. Easier. Better.

Application of Ultra-Low Bending Loss Fiber PureAccess-R5 to Optical Wiring in FTTx Access Networks

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

CommunicationCables FIBER OPTICS OPGW FTTH

GIGABIT ETHERNET. e-ready Building Next Generation IT infrastructures. The Cabling Partnership. Mike Gilmore Managing Director, e-ready Building

Jumper cable. Feeder cable + connector. Cable clamp. Grounding kit

OptoLup TM POF cable Data Sheet. Overview. COMOSS OptoLup TM Cable is a type of APF, All. for the transmitting. compliant POF cables.

Optical Characteristics of a Reduced Bending-Loss Fiber with a Bending Radius of 5 mm

Cabling, FP PRO-series

Y O U R W A Y ENGINEERING PRODUCTS. adritec.com

UNIRAIL D RS485 and BUS cables

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

Optical Ground Wires (OPGW)

CXP/CFP 100G MPO Cable Assembly

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Transcription:

GUXW Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection 05--0 v5.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6.5/5-OM GUXW04 GUXW06 GUXW08 GUXW 50/5-OM BI GUXW04 GUXW06 GUXW08 GUXW 50/5-OM3 BI GUXWD04 GUXWD06 GUXWD08 GUXWD 50/5-OM4 BI GUXWE4 GUXWE06 GUXWE08 GUXWE 9/5 ITU G.657A BI GUXWA04 GUXWA06 GUXWA08 GUXWA 9/5 ITU G.657A BI GUXWF04 GUXWF06 GUXWF08 GUXWF 9/5 ITU G.657B3 BI GUXWI04 GUXWI06 GUXWI08 GUXWI Std. plywood reel (non-returnable) Std. delivery length Ø800*475mm 7.65 kg 00 ± 05m Ø000*530mm 8 kg Applications Structured (premises) wiring systems: campus and/or building backbone (riser) and/or horizontal cabling. Support all computer network applications such as FDDI, Gigabit Ethernet and ATM. Easy to install in ducts, tunnels and trenches. Not recommended for direct burial. Features & Benefits These cables are halogen-free (= FRNC and LSNH) and watertight and therefore suitable for internal and external use. Consequently splicing can be avoided and the installation gets more cost-effective. High mechanical and full rodent protection provided by Steel Wire Armor (SWA). Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794). Swellable reinforced glassyarns as common strength members and for the longitudinal watertightness.. Primary coated optical fibres: Ø 80 ± 5 um. 3. Tight buffered fibres: Ø 0.9 ± 0.05 mm. Colour coding of the buffered fibres: white red blue yellow green violet brown black orange turquoise pink grey The fibres 3 4 are ringmarked. 4. Swellable glassyarns for longitudinal watertightness. 5. Halogen-free inner jacket. 6. Steel Wire Armouring (SWA): helical stranded galvanized steel wires of Ø 0.9 mm 7. Black halogen-free (FRNC/LSNH) outer jacket. Identification: BELDEN OFC cable type number x type of fibre + date-, meter- and. Mechanical Data No. of fibres 4 6 8 Ø nom. (mm) 0.8.. 4.0 Max. pulling tension (N) Short term 30 460 50 330 Energy of flame (kj/m) 05 50 77 746 Weight (kg/km) 3 46 5 33

Optical Characteristics Characteristics Single-Mode Matched-Cladded optical fibres according to ITU. Fibre-Type Mode-Field /Cladding Diameter (um) Attenuation B typical/ max. (db/km)) Dispersion (ps/(nm-km) PMD A (ps/km) Cable Cut-off A 9/5 G.657A BI 8.9 ± 0.4 4.8 ± 0.3 30 65 0.34 / 0.35 0.9 / 0 / 4 3.5 8 0.06 60 F 9/5 G.657A BI 8.9 ± 0.4 4.8 ± 0.3 30 65 0.34 / 0.35 0.9 / 0 / 4 3.5 8 0.06 60 I 9/5 G.657B3 BI 8.8 ± 0.4 5 ± 0.4 30 65 0.34 / 0.35 0.9 / 0 / 3 3.5 8 0.06 60 Note A- Link design value Note B- Due to cabling the optical attenuation values can increase with max 0.5 db/km (30 nm), max. 0.09 db/km ( nm) and max. 7 db/km (65 nm) Characteristics Multi-Mode Graded-Index optical fibres according to IEC 60793 Fibre- Type Core/ Cladding Diameter (um) Attenuation C typical/ max. (db/km)) Bandwidth (MHzkm) Ethernet Performance (m) GBE 0 GBE Num. Apert. (µm) 6.5/5 OM 6.5 ±.5 5 ±.7 / 3.0 0.7 / 0.8 00 600 0 33 75 ± 0.05 50/5 OM BI 50 ±.5 5 ±.3 /.5 / 0.6 600 600 83 0 ± 0.05 D 50/5 OM3 BI 50 ±.5 5 ±.3 /.5 / 0.6 000 0 ± 0.05 E 50/5 OM4 BI 50 ±.5 5 ±.3 /.5 / 0.6 3500 00 0 ± 0.05 Note C- Due to cabling the optical attenuation values can increase with max. 0.4 db/km 3

Macro Bending Performance Fibers Maximum attenuation increase for Bend Insensitive Single Mode fibers in db depending on turns and radius. Fibre-Type 00 5 mm 0 5 mm Turn 0 mm Turn 7.5 mm Turn 5 mm ) A 9/5 G.657A 65 0.0 0.05 F 9/5 G.657A 65 0.03 0. 0..0 I 9/5 G.657B3 65 0.03 0.0 0.08 5 0.5 0.45 Maximum attenuation increase for Bend Insensitive Multi Mode fibers in db depending on turns and radius. Fibre-Type 6.5/5 OM 00 37.5 mm 5 mm ) 7.5 mm 50/5 OM BI 0. 0.3 D 50/5 OM3 BI 0. 0.3 E 50/5 OM4 BI 0. 0.3 4

Mechanical, Physical and/or Environmental Characteristics Description: Tested according to: Requirement: According to Family specification: Storage Temperature Range IEC 60794---F -30 to +70 C IEC 60794--0 Installation Temperature Range -5 to +50 C Operating Temperature Range -30 to +70 C Strippability Secondary coating only 0 cm Secondary + primary coating 0 mm Bending radii for fibres and tight buffers Installation/operation For Bend Insensitive fibres >5 mm See Optical Characteristics Cable Core Water Blocking IEC 60794---F5 Pass Cable Min. Bend Operation (Long Term) IEC 60794---E 5 x Cable Diam. IEC 60794--0 Cable Min. Bend Installation (Short Term) IEC 60794---E6 0 x Cable Diam. Cable Max. Tensile Strength Operation (Short Term) IEC 60794---E See table with dimensions IEC 60794--0 Cable Max. Crush Resistance Operation (Long Term) Cable Max. Crush Resistance Installation (Short Term) IEC 60794---E3 8 kn/m 0 kn/m IEC 60794--0 Safety Testing standard Description / Value Reaction to fire IEC 6033- IEC 6033-3- Smoke density IEC 6034- Halogen acid gas content IEC 60754- Zero Degree of acidity of gases IEC 60754- Min. 4.3 ph IEC 60754- Max. 0 µs/mm 5

Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. It is advisable to cap the cable-ends during storage. Options Non-standard cable constructions with standard rodent protection, colours, details and/or additional information regarding specifications are available on request. 6