INSTALLATION MANUAL. Table of Contents Page

Similar documents
Glulam Connection Details

3.1 General Provisions

Fastener Type Chart. Fastener Categories. Sheet Metal Screws Fully threaded screws with a point for use in sheet metal. Abbreviated SMS.

ROOF-CEILING CONSTRUCTION

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

eb^sv=qfj_bo UNIVERSITY OF WISCONSIN - STOUT COLLEGE OF SCIENCE TECHNOLOGY ENGINEERING & MATHEMATICS Architectural Technology AEC 233

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

A Shell construction

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

Butt Two pieces of wood meeting with flat sides adjoining usually at right angles. Some type of connector is needed to prevent movement.

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Installation and Assembly: Ceiling mount for LCD screens up to 29"

Attach Trusses and Rafters Faster

HOME STRENGTHENING GUIDE HOW TO ECONOMICALLY STRENGTHEN YOUR HOUSE AGAINST EARTHQUAKES AND HURRICANES

Dublin Stalls Installation Instructions

Chapter 1. Beam and Sill Plates

Designed for Building Designed for Living

Installation Instructions for Solar Snow Pad (SSP-T-3)

MTS-ACB. RENOGY Photovoltaic Module Adjustable Curved Bracket E Philadelphia St, Ontario, CA Version: 1.

Downtown Rack. Custom logo option available

SECTION ROUGH CARPENTRY

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1

Umbrella Inserts and Stubby Screens

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Expressed Hardwood Structures

REPAIR INSTRUCTIONS: CABLE

mila-wall (Series100) General Operating Instructions page 1 of 15

ASSEMBLY AND ADJUSTMENT

b) It is assumed a suitably qualified electrical installer will make all electrical connections.

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Large Diameter Tapcon

Technologies, Inc. Installation Instructions for Anchors & Components. Rev PAGE 1 / 11

Umbrella Inserts and Stubby Screens

With time, the evolution of anchors have led to different designs More than one anchor type may be suitable for a particular purpose Thus there are

Closet Wall Drawer Unit

INSTALLATION INSTRUCTIONS

APA Performance Rated Rim Boards

Mount to the Wall INSTALLATION MANUAL

A. Rough carpentry includes but is not limited to the following:

FENCE INSTALLATION GUIDE 8 HIGH WALLS

Design Nailed and Wood Screwed Connections with Spreadsheet. Course Content

TABLE OF CONTENTS REQUIRED TOOLS

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

- Before You Begin - Standard Apex / Tall Apex Shed Kit Instructions IMPORTANT!

8' x 22' Cash Hut INSTALLATION INSTRUCTIONS

WOODEN BUILDINGS 6.1 INTRODUCTION 6.2 TYPICAL DAMAGE AND FAILURE OF WOODEN BUILDINGS. Chapter 6

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

EDGE2 DUAL MONITOR ARM

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

FORTRESS BOTTOM PLATE ANCHORS. Product. Scope. Building Regulations. Appraisal No. 687 [2017]

Installation and Assembly: Full Service Video Wall Mount

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

Swerve Rack CUSTOM RACKS AVAILABLE

LOG CABIN 40 ASSEMBLY INSTRUCTIONS

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

Assembly and installation help

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

AFB (AIR FAN BEARING) INSTALLATION GUIDE

GLOSSARY OF TERMS SECTION 8

Ratcheting and Angled Leg Vises. Ratcheting Parallel Guide

RUN-IN SHED INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MODUL METAL EXTERIOR

Sigma Fasteners, Inc. Section 7

APPENDIX FENCE GENERAL NOTES

Lok Fast Column Clamp General Information

FASTENERS BUILDING DEPARTMENT

INSTALLATION INSTRUCTIONS

VERSA-LAM. An Introduction to VERSA-LAM Products

joining materials - wood

Universal Projector Ceiling Mount Model: DPM-45

A Long-Term Survival Guide - How To Make Bamboo Joints:

ATTACH WALL PLATE TO WALL

KOLO SHELTER Installation Instructions Parts List

DUTCH GABLE FREESTANDING CARPORT

MOTORIZED STANDARD SHADE WITH CABLES Installation Instructions

Unirac Installation Manual

MONKEY BARS OVERHEAD RACK INSTALLATION

Installation Guide. deckorum Composite Decking

Mould Precision Co., Ltd

Installation Procedures

Side Mount INSTRUCTION BOOKLET #C122 BED STYLE: PARK CITY

Instruction Manual for MHE Products DeepWater2 PushPoint Sampler Ver. 2.0 November 21, 2016

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

Baby Grande or Grande Crank Shade with Cables and Housing Installation Instructions

Assembly Instructions

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

INSTALLATION INSTRUCTIONS

FENCE INSTALLATION GUIDE 6 HIGH FENCE

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

ALL SEASON PATIO COVER

Complete line of Holemaking Products and Accessories

RITE-HITE RAINGUARD TM

TITAN INDUSTRIAL RACK 6-FOOT TALL / 4-SHELF

Installation & Assembly: Two Piece Suspended Ceiling Plate

Ref: x 3m - 12 x 10 Pavilion with Single Rail Beams Step by Step Assembly Instructions. Product Ref:

Removing and Replacing the Y-truck

INSTALLATION INSTRUCTION

Lange Crank Hoist-a-top Assembly Instructions

Transcription:

INSTALLATION MANUAL Table of Contents Page parts description. 2 location of connector.. 3 drilling specifications.. 5 joint assembly. 6 split-ring connectors... 7 special purpose connectors.. 7 pin hole centering measurements... 7 recommended load ratings... 8 5 Jean Dempsey Gate West Hill, Ontario M1C 3C1 Canada TIMBERLINX Division of Michael Preston Distributors Limited Phone 416 284-8934 Fax 416 284-5152 Email timberlinx@sympatico.ca www.timberlinx.com U.S. pat. 5,741,083 Rev 1 st November 2003 Can. pat. 2,119,719

PARTS DESCRIPTION A : connecting tube The connecting tube is inserted equally into both joint members, perpendicularly to the contact area of the joint. B : expanding pin The expanding pins are inserted through each joint member, perpendicularly to the connecting tube, which they cross through slots "C". C : pin slot The elongated pin slots receive the expanding pins and provide room for expansion. D : tightening bolt Each expanding pin has a through bolt that can drive a pair of wedges "E" towards each other. E : expansion wedges The expansion wedges, when forced towards each other, pry apart both halves of the pin, expanding it in one direction. F : positioning shoulder These protrusions on the sides of the pins stop them at the correct location 2

CONNECTOR LOCATION Regardless of other considerations, access to each pin's expanding mechanism must be retained throughout structure assembly. Access must also be retained after completion if unseasoned lumber was used. Permanent accessibility is always a desirable feature. 1 - Right angle connections. - single connector: the connector should be located at the geometrical center of the contact area (fig.1). - double connector: the connectors should be located along the greater median line of the contact area, spaced equally from its midpoint, not less than 6.5 cm (2-1/2") apart (fig.2) - The member perpendicular to the connector tube may have the tube hole drilled right through, to allow insertion of the tube after the members have been positioned. This is often necessary when assembling configurations containing angled joints, such as trusses. fig. 1 fig. 2 3

2 - Angled connections. The connector should be located along the greater median line of the contact area, at a point that optimizes its effectiveness without compromising the members integrity. This ensures sufficient end distance from the pin, without being closer to the heel of the sloping member than necessary. Note: The connector tube cannot be allowed to protrude nor to be truncated in any way. In most cases, using the formula described in fig.3 will be satisfactory for a single connector, and also for a double if the connectors are kept a minimum of 6.5 cm (2-1/2") apart (fig.4). Either half of the tube hole may be drilled right through, to allow insertion of the tube after the members have been positioned. This is often necessary when assembling configurations containing angled joints, such as trusses. fig. 3 fig. 4 4

DRILLING Holes required for connector installation must be clean, straight, accurate bores best obtained with a drill press, when possible, or with a special drilling guide. Auger, sawtooth or twist drill bits are suitable, ordinary spade bits are not. A single size (1-1/8 or 28mm)* is required for all holes. This includes the holes for pins, as room is needed for 8mm (5/16") expansion. Bits must be able to drill into the wood to a depth of 12.5 cm (5"), cross- grain or end-grain. While some inaccuracy is acceptable for the pin bores, to the extent that pin insertion and expansion are still possible, both holes for the connector tube must be exactly perpendicular to the joint's contact area in order to line up Having to enlarge these would result in possible lateral movement of the joint, at the detriment of its resistance to sheer. Location of drilled holes, illustrated below (fig. 5), should be: - midway through the thickness of the members, for the tube, - centered exactly 10cm (3-15/16") away from the contact area for the pins. Pin bores must be perpendicular to the tube bore and centered on it. * (We recommend 1-1/8 or 28mm drill bits for all holes. 1-1/16 may be used for the pipe hole in seasoned lumber.) fig. 5 5

JOINT ASSEMBLY Careful consideration should be given to the assembly sequence of the structure being built. First of all, the 24cm (9-1/2") tube has to be inserted into one member of the joint, and then the other member has to slip over the protruding half. At some point the two parts of each joint have to be 12cm (4-3/4") apart prior to being connected. In situations where this is not possible (trusses for example), one of the members may have its tube hole drilled right through, to allow insertion of the tube after the members have been positioned. While this doesn't affect the strength of the joint, it requires more drilling, as well as plugging the extra perforation where it might not be concealed. Good planning sould keep this to a minimum. Assembling the joint is otherwise quite simple: - insert the tube into either one of the members - rotate it until the pin slot is in line with the pin bore - insert a positioning tool to hold it in place - slip the other member over the protruding part of the tube - insert the second positioning tool right through the 2nd member's pin hole and lever the tube away from the opposite end, until all play has been picked up. There should now be enough room to insert both pins. (Use the special insertion tool.) - using the Allen wrench, screw in the tightening bolt(s). If there is no more than 3mm (1/8") of play to be picked up before the joint starts to tighten, only 1 pin needs to be expanded. Otherwise try to divide the action of both pins equally. In all cases, do not underestimate the tremendous power of the expanding pins: overtightening will indent the wood the pins are resting on and reduce the availability of further expansion which might be needed if the lumber shrinks. Generally, 1/2 to 3/4 of a turn past the point where the joint is firm is quite sufficient - testing a joint with 2 scraps is a good way to feel what's right if you are new to the connector. NB Positioning Tools (pair) and Insertion Tool are available from supplier 6

SPLIT RING CONNECTORS To achieve greater shear resistance than the recommended rating (see "recommended load ratings" p8), for example with joist-bearing beams, standard split ring connectors (also called timber rings) can easily be added to the connection. Using the proper grooving tool, make grooves on both faces of the joint, centered on the connecting tube, before drilling for the tube. For specific ratings, consult with us or with an engineer. SPECIAL PURPOSE CONNECTORS The connector lends itself to an almost infinite variety of modifications for unusual situations. While some will become off-the-shelf items, others can be obtained as special orders. Here are some examples: connectors to anchor timbers to foundations or masonry walls connectors to fasten timbers to existing structures elongated connectors to fasten 2 beams through a post angled clusters for conical roof apexes roof sill to rafter connectors, including polygonal structure s hip to sill corner tie-up PIN HOLE CENTER TO CENTER MEASUREMENTS for various size TIMBERLINX (1-1/8 or 28mm bit only) A 095 9-1/2 connector 7-7/8 B 095 9-1/2 connector 7-7/8 A 155 15-1/2 connector 13-7/8 B 155 15-1/2 connector 13-7/8 A 175 17-1/2 connector 15-7/8 B 175 17-1/2 connector 15-7/8 A 475 4-3/4 half connector 7-7/8 plus threaded rod 7

RECOMMENDED LOAD RATINGS Standard term loading² Short term loading² Property single connector two connectors³ single connector two connectors³ (kn) (lb) (kn) (lb) (kn) (lb) (kn) (lb) Tension parallel to 12.0 2690 17.4 3920 13.7 3090 20.0 4510 grain Tension perpend. 11.2 2510 17.4 3920 12.9 2890 20.0 4510 to grain Shear parallel to 16.4 3700 - - 18.9 4260 - - grain Shear perpend to 7.3 1640 - - 8.4 1890 - - grain Notes: 1. For use with the limit states design procedures of the 1995 National Building Code of Canada and CSA Standard O86.1-94. 2. Short term loading includes wind and earthquake loads Standard term loading includes dead plus snow or use and occupancy loads 3. Connectors to be spaced 2-1/2" (65mm) on center minimum. In parallel to grain applications the edge distance shall be 1-1/2" (38mm) minimum 4. Values are for dry service conditions with no fire retardant treatment 5. Values are for minimum 6x6 (140mmX140mm) white pine or denser material 6. In all applications the pipe connector should be equally embedded into the two timber members. The hole for the pipe shall be 1-1/8" (28mm) diameter. Holes for the expansion anchor shall be 1" (25mm) to up to 1-1/8" (28mm) diameter. Table established by: Quaile Engineering Ltd 130 Davis Drive, Newmarket, Ontario, Canada L3Y 2N1 1-877-364-5209 quaile.eng@on.aibn.com 8