Rotary actuators for ball valves

Similar documents
Rotary actuators for ball valves

Rotary actuators for ball valves

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Rotary actuators for ball valves

Rotary actuators for ball valves

Rotary actuators for ball valves

Air damper actuators

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

OpenAir Linear actuators GDB/GLB...2 Technical basics. CE1Z4664en Building Technologies

Electromotoric actuators

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Electromotoric actuators for stroke valves

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

M7061 ROTARY VALVE ACTUATORS

Outside Temperature Sensors

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Room Sensors. for relative humidity and temperature

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Electromotoric actuators for valves

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

Functional data Factory settings Variable Settings

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data sheet. Technical data. Safety notes

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Technical Instructions Document No EA GQD June 23, OpenAir

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

QFM21... Duct sensors. Symaro. for relative humidity and temperature

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Power consumption In operation At rest For wire sizing

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Power consumption In operation At rest For wire sizing

Room Temperature Controllers. for heating and cooling systems

Type overview. Technical data

Technical data. Safety notes

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Parameterisable damper actuator in the

Wireless multizone receiver RDE-MZ6

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Rotary gear motor series AG8...

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

Room Temperature Controllers. for heating and cooling systems

Float switch For industrial applications, plastic version Model RLS-2000

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Actuators for modulating control AME 85, AME 86

Zelio Control Measurement Relays

s Climatix extension module 26 I/Os POL985.00/XXX

Modulating control valves with magnetic actuator, PN 16

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Type overview

Spring Return DuraDrive Proportional Actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Differential pressure sensors

Room Temperature Controllers. for heating and cooling systems

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Rudder or propeller angular position transmitter KINAX WT720

Room Temperature Controllers. for heating and cooling systems

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Rotary Measuring Technology

EY-EM 522, 523: Remote I/O module, ecolink522, 523

Room Temperature Controllers. for heating and cooling systems

Rotary Measuring Technology

C series Product brief

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Type 3374 Electric Actuator

Power amplifier for thermic valve actuators

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Transcription:

4 657 Rotary actuators for ball valves GDB..9E GLB..9E for ball valves VAI61.. and VBI61.. / AC 230 V Electromotoric rotary actuators for 3-position and modulating control, pre-wired with 0.9 m long connection cables. Remarks This data sheet provides a brief overview of these rotary actuators. Please refer to the Technical Basics in document Z4634en for a detailed description as well as information on safety, engineering notes, mounting and commissioning. Use For 2-port and 3-port threaded ball valves from DN15 to DN50 Suitable for use with modulating controllers (DC 0 10 V) or 3-position controllers CM2N4657en 01.03.2010 Building Technologies

Type summary GDB/GLB131.9E GDB/GLB331.9E GDB/GLB161.9E Operating voltage Operating voltage AC 230 V 3-position Positioning signal Y = Position indicator U = Self-adaption of rotational angle range Rotary direction switch Functions Type GDB/GLB131.9E / GDB/GLB331.9E GDB/GLB161.9E Control type 3-position control Modulating control Rotary direction Clockwise or counter-clockwise direction depends....on the type of control. With no power applied, the rotary actuator remains in the respective position. NC (normally closed) ball valve Signal on Y1 rotation counter-clockwise ball valve opens Signal on Y2 rotation clockwise ball valve closes NO (normally open) ball valve..on the setting of the rotary direction DIL switch clockwise / counterclockwise NC (normally closed) ball valve DIL 2 set to counter-clockwise Flow = 0% at Y = 0 V Flow = 100% at Y = 10 V NO (normally open) ball valve Position indication: Mechanical Position indication: Electrical Manual adjustment Signal on Y2 rotation clockwise ball valve closes Signal on Y1 rotation counter-clockwise ball valve opens DIL 2 set to clockwise Flow = 100% at Y = 0 V Flow = 0% at Y = 10 V Rotary angle position indication by a position indicator/hand lever. Output voltage U = is generated proportional to the rotary angle. U depends on the rotary direction of the DIL switch setting. The rotary actuator can be manually adjusted by pressing the gear train disengagement button. 2/6

Equipment combinations The rotary actuators are suitable for operation of the following Siemens 2-and 3-port ball valves: VAI61.. VBI61.. PN GDB..9E GLB..9E Rp DN Type k vs [m 3 /h] Type k vs [m 3 /h] class Δp max Δp s Δp max Δp s Data sheet VAI61.15.. 1 10 VBI61.15.. 1.6 6.3 Rp ½ 15 VAI61.20.. 4 10 VBI61.20.. 4 6.3 Rp ¾ 20 350 1400 350 1400 VAI61.25.. 6.3 16 VBI61.25.. 6.3 10 Rp 1 25 PN40 VAI61.32.. 10 25 VBI61.32.. 10 16 Rp 1¼ 32 350*/240** 1000 VAI61.40.. 16 40 VBI61.40.. 25 Rp 1½ 40 350*/240** 800 N4211 VAI61.50.. 25 63 VBI61.50.. 40 Rp 2 50 350*/240** 600 * VAI61.32-10/16, VAI61.40-16, VAI61.50-25 **VAI61.32-25, VAI61.40-25/40, VAI61.50-40/63 * VBI61.15 VBI61.40-16 **VBI61.40-25, VBI61.50-40 Notes Mounting For more details about these rotary actuators see document Z4634. Both ball valve and rotary actuator can easily be assembled at the mounting location. Neither special tools nor adjustments are required. The rotary actuator is supplied with Mounting Instructions 74 319 0646 0 The ball valve is supplied with Mounting Instructions 74 319 0647 0 Orientation 90 90 4716Z16 Commissioning Manual adjustment When commissioning the system, check wiring and the functions of the rotary actuator. The rotary actuator can be manually adjusted into any position between 0 and 90 by pushing the gear train disengagement slider. If a control signal from the controller is present, this will take priority in determining the position after the slider is released. 3/6

Technical data GDB..9E / GLB..9E supply (SELV/PELV) AC 230 V supply Function data Positioning signal for GDB161.9E/GLB161.9E Position indicator for GDB/GLB161.9E Connection cable Degree of protection of housing Protection class Environmental conditions Standards and directives Weight Operating voltage / Frequency Power consumption GDB131.9E/GLB131.9E GDB161.9E/GLB161.9E Running Running Holding Operating voltage / Frequency Power consumption GDB331.9E/GLB331.9E Running Nominal torque Nominal rotary angle / Max. rotary angle Runtime for 90 rotary angle (GDB/GLB) Input voltage Y (wires 8-2) Max. permissible input voltage Output voltage U (wires 9-2) Max. output current Cross-section Standard length Degree of protection as per EN 60 529 (note mount. instructions) Insulation class AC 230 V Operation / Transport Temperature Humidity (non-condensing) Product safety: Automatic electrical controls for household and similar use Electromagnetic compatibility (EMC): Immunity Emission Conformity: Conformity: Without packaging: Electromagnetic compatibility Low voltage directive Australian EMC Framework Radio Interference Emission Standard ± 20 % / 50/60 Hz 2 VA / 1 W 3 VA / 2 W 1 W AC 230 V ± 10 % / 50/60 Hz 2 VA / 1 W 5 Nm (GDB) / 10 Nm (GLB) 90 / 95 ± 2 150 s (50 Hz) / 125 s (60 Hz) DC 35 V, internally limited to DC 10 V DC ± 1 ma 0.75 mm 2 0.9 m IP54 EN 60730 lll ll EN 60721-3-3 / EN 60721-3-2 32...+55 C / 32...+70 C < 95% r. h. / < 95% r. h. EN 60730-2-14 (Type 1) IEC/EN 61000-6-2 IEC/EN 61000-6-3 2004/108/EC 2006/95/EC Radio Communication Act 1992 AS / NZS 3548 0.75 kg Disposal The document on technical basics Z3634en and the environmental declaration provide information on environmental compatibility and disposal of this device. 4/6

Internal diagrams GDB131.9E / GLB131.9E 3-position control GDB331.9E / GLB331.9E 3-position control AC 230 V AC 0 V AC 230 V 6 7 6 7 M M (G) 1 4 GDB161.9E / GLB161.9E Modulating control DC 0 10 V SELV/PELV 1 8 M 100% 0% (G0) (U) 2 9 Cable labeling Connection Cable Code No. Color Abbreviation Meaning Rotary actuator G 1 red RD System potential G0 2 black BK System neutral Y1 7 orange OG Positioning signal AC 0 V, counterclockwise Y2 6 purple VT Positioning signal AC 0 V, clockwise Y 8 grey GY Positioning signal DC 0 10 V U 9 pink PK Position indication DC 0 10 V Rotary actuator N 4 blue BU Neutral conductor AC 230 V Y1 7 white WH Control signal AC 230 V, counter-clockwise Y2 6 black BK Control signal AC 230 V, clockwise 5/6

Dimensions 112.4 108 143.2 = > 100 mm = > 200 mm Minimum clearance from ceiling or wall for mounting, connection, operation, maintenance etc. 87.5 73.8 4657M01 Dimensions in mm 6/6 2010 Siemens Switzerland Ltd Subject to change