Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Similar documents
TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Outdoor, Fig 8 Armored, Multi Tube

Outdoor, CCTV or CCTV, Fig 8 Armored.

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

SPECIFICATION. Optical Fiber Cable

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

ETK Kablo SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -LWP)

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Standard Monotube SAFE

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

Ø 1250 * 688 mm 93 kg ± 105m

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

JFOC-BSG2D MODEL:JFOC-BSG2D. optic.com. For detailed inquiry please contact our sales team at:

Type QG-G50-2C- M-BU

Ø560*336mm 4.25 kg 2100 ± 105m

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

features and benefits

CommunicationCables FIBER OPTICS OPGW FTTH

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

OFS AllWave non-dispersion shifted single-mode optical fiber

Single-Armored Cables, Fibers

Optical Systems Contents

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

Integrating Global Communications...

Fiber Optic Outside Plant Cables (4-144 Fibers)

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Nufern 980 nm Select Cut-Off Single-Mode Fiber

ZHONGTIAN TECHNOLOGIES CO., LTD ZHONGTIAN TECHNOLOGIES FIBER OPTICS CO., LTD

INTERNATIONAL TELECOMMUNICATION UNION TRANSMISSION MEDIA CHARACTERISTICS CHARACTERISTICS OF A DISPERSION-SHIFTED SINGLE-MODE OPTICAL FIBRE CABLE

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Datasheet Outside Plant Cable

Industrial Automation

PERFORMANCE SPECIFICATION SHEET

ITU-T G.654. Characteristics of a cut-off shifted single-mode optical fibre and cable

ABOUT US ABOUT US 1 CRANE CABLES

ITU-T G.656. Characteristics of a fibre and cable with non-zero dispersion for wideband optical transport

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

FiberHome Fiber Products

Electric cables. Cranes

u n a B Optical Cables UNIFLEX CABLES LTD.

For Public Comment DRAFT MALAYSIAN STANDARD STAGE : PUBLIC COMMENT (40.20) DATE : 01/10/ /11/2015

DISPERSION COMPENSATING FIBER

Exhibit A Construction Project Manual and Drawings

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

Fibre Optic Indoor/Outdoor Cable

Z EE E E Z E Z Z Z Z Z

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

3M Clear Track Hallway Fiber Pathway

Optical Characteristics of a Reduced Bending-Loss Fiber with a Bending Radius of 5 mm

Measurement Considerations for Corning ClearCurve LBL and ZBL Optical Fiber

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

kv: medium voltage reeling cable with fibreoptics

Optical Ground Wires (OPGW)

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

Cable Type 100. CAI Certification Specification

Introduction.

Cable Type 125. CAI Certification Specification

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor

DRAFT MALAYSIAN STANDARD. Telecommunication cable: Single-mode optical fibre cable - Loose tube type for aerial installation

FTTH Fiber Optical Cable

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

Outside Plant All Dielectric

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Application of Ultra-Low Bending Loss Fiber PureAccess-R5 to Optical Wiring in FTTx Access Networks

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

DSMF FIBERS, A COMPARISON OF VARIOUS SOLUTIONS

Chapter 3 Signal Degradation in Optical Fibers

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Connection technology for wireless communication systems

Copper and Fiber Optic Cables

FCQ1064-APC 1064 nm 1x4 Narrowband Coupler. Mounted on

Advanced Fibre Testing: Paving the Way for High-Speed Networks. Trevor Nord Application Specialist JDSU (UK) Ltd

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Fiber Optic Principles. Oct-09 1

How to Speak Fiber Geek Article 2 Critical Optical Parameters Attenuation

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Optical Fiber Technology. Photonic Network By Dr. M H Zaidi

T E C H N I C A L D A T A for

Technical specification SiMTaCS Single Mode Tactical Cable System

Transcription:

SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D Product Model: GYFXTY 2~12C Our Ref: No.TS-FT201107-03-64-V1.0 GENERAL 1.1 These optical cables have excellent protection, optical transmission and mechanical performance. 1.2 The cable differential is to be composed of a single loose tube. 1.3 This specification covers the construction and the properties of Single Tube Dielectric Optical Cable. 1.4 This cable shall be used for internal or external installation, such as local internal networks and FDDI networks. 1.5 This cable has transmission capacity in wavelength of 850nm, 1310nm or 1550nm. 1.6 Color pattern is the same as NBR 9140 (Brazillian Standard) 1.7 Applicable Specification: ETT 0011/95 (Telcon) CROSS-SECTION FIGURE Optical Fiber Jelly PBT loose tube PE shealth Aramid Yarn Figure 1, Cross-section of Cable (GYFXTY 12C)

OPTICAL FIBER IN CABLE (ITU- G.652.D) Optical properties of the SM fiber are achieved through a germanium doped silica base core with a pure silica cladding which meets ITU-T G652D, UV curable acrylate protective coating is applied over the glass cladding to provide the necessary maximum fiber lifetime. Geometrical, optical, and mechanical characteristics of fiber in cable as the following table: 3.1. Construction Fiber Type Single mode type material Ge doped fused silica Mode field diameter 1310 nm 9.2±0.4 μm 1550nm 10.4±0.8 μm Core concentricity error 0.6 μm Cladding diameter 125±1.0 μm Cladding non-circularity 1% Coating material UV curable acrylic diameter 242±7 μm Cladding/Coating concentricity error 12 μm Coating non-circularity 6% Fiber proof-tested 0.7 Gpa (1%)in accordance with the optical fiber proof test by IEC 60793-1-B1 3.2 Optical characteristic Attenuation 1310 nm 0.35 db/km 1490 nm 0.21 db/km The Temperature dependent of Attenuation Induced Attenuation -10 C to 70 C Macrobend Attenuation (100 turns 60 mm. Diameter) The increase or decrease attenuation values not exceed 0.05 db/km 1310 nm 0.05 db 1550 nm 0.10dB Zero-Dispersion Wavelength 1300-1324 nm Zero Dispersion Slope Max. 0.092 ps/(nm2/km ) Chromatic Dispersion Coefficien 1228~1339 nm 3.4 (ps/nm.km) 1550 nm 17.5 (ps/nm.km) Cable Cut-off Wavelength (λ cc) 1260nm Polarization Mode Dispersion(PMD) 0.15 ps/km1/2

OPTICAL CABLE DESIGN 4.1. Cable construction and parameter Number of fibers 2~12 Fiber Construction Consult 3.1 Filling Compound Material Thixotropic Jelly Compound Loose Tube (mm) Material (PBT) Polybutylene Terephthalate Color Identification Nature Outer Diameter 3.5 (mm) Strength Member Material Aramid yarn Core Filling Compound Material Water Blocking Gel Outer Sheath Material PE Thickness(mm) 1.0 Cable Diameter Approx. (mm) 5.5 Cable Weight Approx. (kg/km) 30 4.2. Mechanical and Environmental Features Tensile performance (N) Crush (N/100mm) Short term Long term Short term Long term 500 200 1000 300 4.3. Identificatiuon: Color Code for fibers N Loose tube Identification Fiber Identification 1 White Blue 2 - Orange 3 - Green 4 - Brown 5 - Gray 6 - White 7 - Red 8 - Black 9 - Yellow 10 - Violet 11 - Rose 12 - Aqua

OPTICAL FIBER CABLE CHARACTERISTICS The cable characteristics shall be as following: 5.1 Tensile Loading Loading Loading Time 5.2 Impact Impact energy Number of cycles 5.3 Crush Test Steel plate Loading Loading time IEC 60794-1-2-E1 500N At least 5 min. No fiber break and no sheath damage. The fiber strain is measured during the cable has been subjected to the installation load 5 min. A fiber strain shall not be greater than 0.33% during and after testing. IEC 60794-1-2-E4 3J, Radius of hammer head 250mm 20 cycle,2 second/cycle IEC 60794-1-2-E3 100 mm 1 Cable weight per km At least 10 min. 5.4 Cable Bending Test IEC 60794-1-2-E11A Diameter of mandrel 10 x diameter of cable Number of cycles 5 cycles 5.5 Flexing / Repeat Bending Test IEC 60794-1-2-E6 Diameter of mandrel 10 x diameter of cable Number of cycles 25 cycles,2 second/cycle 5.6 Twist Torsion Test Sample length Number of cycles Twist angle IEC 60794-1-2-E7 2 m 10 cycles, 1 Min./cycle ± 180

OPTICAL FIBER CABLE CHARACTERISTICS 5.7 Water penetration Test IEC-794-1-2-F5 High of water column 1 m Sample length 3 m Test time At least 24 hour At the end, no water shall have leaked from the opposite end of the cable. 5.8 Circumnutate Test IEC 60794-1-2-E8 Diameter of mandrel 20 x diameter of cable Number of cycles 25cycles Change of attenuation < 0.1 db. 5.9 Temperature Cycling Test IEC 60794-1-2-F1 Number of cycles 2 cycle Temperature -20 C to + 70 C Time 24hours Change of attenuation < 0.1 db. 5.10 Compound Flow Test IEC 60794-1-2-E14 Sample 5 Sample length 300±5mm Remove length 130±2.5mm Time 24hours No gel dripped. Remark: No attenuation changes is considered as the attenuation changes 0.05 db. ENVIRONMENT CONDITIONS The cable shall retain the optical properties, detailed in the present specification over the following: Installation temperature : -10 C to + 70 C Operating temperature : -20 C to + 70 C Storage / Shipping temperature : -20 C to + 70 C Relative humidity : 0 to 90 %

IDENTIFICATION MARKING Unless otherwise specified, the cable sheath marking shall be as follows: Color : white Contents: The name of manufacturer, the year of manufacture, the type of cable, length marking Interval: 1m PACKING AND SHIPMENT 8.1 Reel Length Standard reel length: 4 km/reel 8.2 Cable Drum The cable are packed in iron-wooden drums The minimum barrel diameter of the drum shall be more than 30times of the nominal diameter for armored cable, and 25 times of the nominal diameter for unarmored cable. 8.3 Labeling The direction of rotation of the color scheme is shown by marking the clockwise and anti-clockwise ends with red and green adhesive tape respectively. The markings are on both sides of the flanges as follows: Cable Type / Size Cable Length Gross Weight FUTONG GROUP Shipping mark 8.4 Packing Both cable ends are provided with protections against water penetration and firmly secured to the drum, so the cable cannot move and the turns cannot slide when it is moved, handled or laid. The inner end has at least 3 meters of accessible length to perform reception tests in the cables.

R PACKAGING DISTRIBUIDO POR Av. Pedro de Valdivia 6154, Macul / Santiago Chile - Fono: (562) 411 4000 Sucursales: Viña del Mar - Fono: (5632) 267 2000 /Concepción - Fono: (5641) 224 7300