ZT 20xx IOG SERIES. Quick Start 1 What s in the Shipping Package? ANT

Similar documents
1 What s in the Shipping Package? The shipping package contains the following items:

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

3V TRANSCEIVER 2.4GHz BAND

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

G3P-R232. User Manual. Release. 2.06

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

WLS (Wireless Locating System)

Tire Temperature and Pressure Monitoring System - Datasheet

instruction manual for Open LRS New Generation

DRF4463D20 Medium Power ISM RF Transceiver Module V1.21

1 What s in the shipping package?

I-7088, I-7088D, M-7088 and M-7088D User Manual

Know your energy. Modbus Register Map EB etactica Power Bar

RF1276 Long Distance Transceiver module V2.0

Low Power with Long Range RF Module DATASHEET Description

VBRC 4. Radio Communicator. Installer Manual

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

CL4790 USER GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

Analog & Digital I/O Wireless Bridge USERS MANUAL R02

2302 Battery Simulator 2306, 2306-PJ Battery/Charger Simulators

BLE 4.0 Module ZBModule User Manual 1 / 15

8V General information. 2 Order data 8V

FRnet Remote I/O Modules

ANLAN203. KSZ84xx GPIO Pin Output Functionality. Introduction. Overview of GPIO and TOU

FLD00042 I 2 C Digital Ambient Light Sensor

Secure, Versatile and Award Winning Network Radio Devices.

Ku-Band VSAT Block Up Converters

InfraStruXure Manager v4.x Addendum: Building Management System Integration

I-2533CS series User Manual

Preliminary. DN-900 Series. 900 MHz Wireless Serial Modems

Pololu TReX Jr Firmware Version 1.2: Configuration Parameter Documentation

Catalogue

Applications QK-W015. Features. Sockets. Smart House. Plant Maintenance Valve Control Pumping Station Security Systems PLC. 1 of 13 V1.

Energy Efficient Spectrum Sensing and Accessing Scheme for Zigbee Cognitive Networks

DESIGN AND IMPLEMENTATION OF DC MOTOR SPEED CONTROL BY ARMATURE VOLTAGE VARIATION USING WIRELESS TECHNOLOGY

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

SV-MESH Mesh network series Catalogue

CoolEx User Manual 2008 XDIMAX LTD. Revision 1.0

QUICK GUIDE for multiguard Light. Installation

Battery Simulator Battery/Charger Simulators

FT-2500 Advanced Tachometer Operation manual

DN-90 Series. 900 MHz Wireless Serial Modems

Welcome! Device Characterization with the Keithley Model 4200-SCS Characterization System.

E31-TTL-500 Datasheet V Feature E31-TTL-500

Endurance R/C Wi-Fi Servo Controller 2 Instructions

General Description. The TETRIX MAX Servo Motor Expansion Controller features the following:

AC MHz OEM TRANSCEIVERS Specifications Subject to Change

SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery

The rangefinder can be configured using an I2C machine interface. Settings control the

Preliminary. RF Data Transmission Rates 38.4, 115.2, 200 and 500 kbps

Firmware Specification

Wireless replacement for cables in CAN Network Pros and Cons. by Derek Sum

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

RC-WIFI CONTROLLER USER MANUAL

External Source Control

MICROWAVE FREQUENCY SYNTHESIZER QP-FSPLL USER MANUAL

Catalog

Wireless Smart Metering LAN-WMBUS-G. Wireless MBUS, high performance Temperature, Humidity and Pulse counting device.

Preliminary. 4-Channel RTD/4-20 ma Wireless Sensor Node SN24R420-4

E70-433MS14 Datasheet v1.1

It s Logical! Technical Newsletter. Logic, the basics you need to know

Interface Manual Tank Level Float Stick System

Mercury technical manual

Integrity Instruments

RF7129 Ultra-low power Tranceiver module V2.0

C-Band VSAT Block Up Converters

USB Multifunction Arbitrary Waveform Generator AWG2300. User Guide

Characteristic Sym Notes Minimum Typical Maximum Units Operating Frequency Range MHz Operating Frequency Tolerance khz

Raritan PX2/PX3 Modbus Interface

LABORATORY AND FIELD INVESTIGATIONS ON XBEE MODULE AND ITS EFFECTIVENESS FOR TRANSMISSION OF SLOPE MONITORING DATA IN MINES

InsuLogix T MODBUS Protocol Manual

ACUMESH - WIRELESS RS485 NETWORK KEY FEATURES ACUMESH - WIRELESS METERING SYSTEM

Quick Start: Radiator Control

INDEX 1 - PRODUCT FEATURES

JDY-08 Bluetooth transparent transmission module

ASCII Programmer s Guide

EOS 80D (W) Wireless Function Instruction Manual ENGLISH INSTRUCTION MANUAL

8V General information. 2 Order data 8V

Radio Bridge User Guide. Document: DOC-VS-RB-UG-C-0

CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

RF1212 RF1212 Ultra-low Power ISM Transceiver Module V2.0

Copley ASCII Interface Programmer s Guide

DNT2400. Low Cost 2.4 GHz FHSS Transceiver Module with I/O

Technical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

Catalogue 1. Brief Description Product feature Typ. Circuit Block Diagram...

1. SYSTEM DESCRIPTION NON - DIRECTIONAL RADIO BEACON TRANSMITTER (NDB) JTM-30C

UNIT A 8-30VDC 8-28VAC POWER V IN3 IN4 COM1/2 NO3 NO4 IN1 IN2 GND NO1 NO2 COM3/4 ANY 8-28VAC OR 8-30VDC POWER ADAPTER (SOLD SEPARATELY)

OVEN INDUSTRIES, INC. Model 5C7-362

TETRIX Servo Motor Expansion Controller Technical Guide

^3 Remote MACRO Interface. ^4 3xx xUxx. ^5 April 4, 2007

Complete 2.4 GHz RF Transceiver Module with Built-In RFDP8 Application Protocol Part Numbers RFD21733, RFD21735, RFD21737, RFD21738, RFD21739

Universal laser controller and testunit for SPI Laser Systems and laser units enabled by PWM or analog control

DESCRIPTION DOCUMENT FOR WiFi <-> RS485 <-> LoRa DEVICE BOARD HARDWARE REVISION 0.1

ADP1043A Evaluation Software Reference Guide EVAL-ADP1043A-GUI-RG

Transcription:

ZT 20xx IOG SERIES Quick Start 1 What s in the Shipping Package? The shipping package contains the following items: ZT 20xx IOG Module ANT 124 05 Quick Start If any of these items are missing or damaged, please contact your local distributor for more information. Save the shipping materials and cartons in case you need to ship the module in the future. 2 Preparing the Device 1. Power Supply: +10 ~ +30 V DC +Vs GND +Vs GND 2. Install "ZT-2000 Configuration Utility" to configure the ZT-20xx-IOG device. - http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/utility/ - CD: \\Napdos\ZigBee\ZT_Series\Utility ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 1

3 Hardware Basic Setting 1. Hardware Setting Interface ZT-2043-IOG ZT-2053-IOG ZT-2055-IOG ZT-2060-IOG RF Channel ON Init. Run Pulse AES128 1 2 3 4 5 6 7 8 9 10 11 12 Disable Level Node ID Reserved AES128 Pulse Init. 2. Basic Setting Parameters for Hardware 1 DIP 1 : Module Initial Mode For normal operation, set the DIP_1 to the RUN position. For advanced setting, set the DIP_1 to the INIT position, then can do the setting by software. Trigger Mode DIP_1 RUN OFF INIT ON Descriptions Pan ID = according to the software setting (Default: 0x0000) RF Channel = set by the rotary switch Node ID = set by the rotary switch Software setting, via ZT-2550/ZT-2570/ZT-USBC remotely Pan ID = 0x3FFF RF Channel = set by the rotary switch ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 2

2 DIP 2 : DI Event trigger mode or way The event trigger modes of the ZT-IOG system, the same are the trigger ways for the DI channel of the ZT-IOG module. Users is able to choose the suitable mode via refering user manual for detail descriptions. Trigger Mode DIP_2 Level Mode OFF Pulse Mode ON Descriptions If any DI channel state is high, all DO channel states are high. If all DI channel states are low, all DO channel states are low. If any DI channel is triggered to rising edge, all DO channels will change to the reverse edge once. 3 DIP 3 : Encryption In wireless communication, it provides data encryption that supports AES-128 bit encryption algorithm. This setting is based on the ZigBee Coordinator, other ZT-IOG modules within the same group are synchronized passively. Encryption DIP_3 Descriptions Disable OFF Not using encryption Enable ON Using AES-128 bit encryption for wireless communications 4 DIP 4~8 : Node ID The Node ID is the ZigBee device ID, or known as the node addresses. The settable range is 0x0000 ~ 0x001F, up to 32 groups, cannot duplicate in the same group A ZT-IOG network must specify a device to 0x0000 (ZigBee Coordinator) The ZigBee Coordinator must be supplied power permanently, or the IOG system cannot work properly. ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 3

Node ID DIP_4 DIP_5 DIP_6 DIP_7 DIP_8 Node ID DIP_4 DIP_5 DIP_6 DIP_7 DIP_8 0x0000 off off off off off 0x0010 ON off off off off 0x0001 off off off off ON 0x0011 ON off off off ON 0x0002 off off off ON off 0x0012 ON off off ON off 0x0003 off off off ON ON 0x0013 ON off off ON ON 0x0004 off off ON off off 0x0014 ON off ON off off 0x0005 off off ON off ON 0x0015 ON off ON off ON 0x0006 off off ON ON off 0x0016 ON off ON ON off 0x0007 off off ON ON ON 0x0017 ON off ON ON ON 0x0008 off ON off off off 0x0018 ON ON off off off 0x0009 off ON off off ON 0x0019 ON ON off off ON 0x000A off ON off ON off 0x001A ON ON off ON off 0x000B off ON off ON ON 0x001B ON ON off ON ON 0x000C off ON ON off off 0x001C ON ON ON off off 0x000D off ON ON off ON 0x001D ON ON ON off ON 0x000E off ON ON ON off 0x001E ON ON ON ON off 0x000F off ON ON ON ON 0x001F ON ON ON ON ON 5 Rotary Switch:RF Channel RF Channel indicates the radio frequency channel, following the IEEE 802.15.4 standard and using the ISM 2.4G radio band. Rotary Switch Range Description Switch 0 ~ F 2405 MHz ~ 2480 MHz a. The RF Channel must be set to the same value as other modules on the same ZigBee network. b. For different ZigBee networks, first priority is to adjust the RF Channel, please directly switch the Rotary Switch. Announce! The 2.4GHz is a universal free-of-use band, such as wireless LAN, Bluetooth, ZigBee, etc., all can work in the 2.4GHz, so the user have better avoid to use the same wireless frequency with other devices in the same place to ensure the communication effectiveness. ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 4

4 Software Advanced Setting 1. Advanced Setting Parameters for Software The following items are the main functions and configurations to the software advanced setting, please refer the user manual for more information. http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-iog/ - Disconnection Detection : Safe Value (Router), Check-Router-Alive (Coordinator) - I/O Channel Pair Relationship : Channel Offset (DI/DO) - Other Parameters : Pan ID, RF Power, Refresh Interval 2. Software Setting Steps The following steps are used to start the advanced setting via software. 1 As the ZT-20xx-IOG device does not include a COM port, the user must prepare a ZigBee converter, e.g. ZT-USBC, ZT-2550 or ZT-2570, to convert the signal to wireless signal via the USB, RS-232 or RS-485 interface for remote setting the ZT-20xx-IOG module. 2 For building the wireless communication of the ZT-20xx-IOG and the ZigBee converter, first, set up the following parameters of the ZigBee converter via the "ZT-2000 Configuration Utility", so it can wirelessly communicate with the ZT-20xx-IOG that in the INIT mode. Model ZT-20xx-IOG ZT-USBC ZT-2550, ZT-2570 Application Mode N/A N/A Transparent Mode Pan ID INIT default to 0x3FFF Set to 0x3FFF by software Node ID INIT default to 0x0020 Fixed to 0x0000 as a ZigBee Coordinator RF Channel Set by Rotary switch Same with the Rotary switch of the ZT-IOG. 3 Switch the Dip Switch 1 (DIP_1) of the ZT-20xx-IOG module to INIT mode. 4 Restart the power of the ZigBee Converter and the ZT-20xx-IOG module, wait for the green LED (ZigBee) of the ZT-20xx-IOG module changing to steady lit, that means the wireless communication established, and then ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 5

can call the software utility. 5 Execute the ZT-20xx-IOG Configuration Utility (Windows Based): 6 Use ZT-IOG Series Configuration Utility to connect the ZT-20xx-IOG. a. Click COM Port Setting to select the COM port of the ZigBee converter. b. Click Read Setting to read the current settings of the ZT-20xx-IOG module. 7 After reading the settings, directly set the parameters in New column. The next section will describe the parameters of the advanced setting. 8 After setting the parameters, click Start Configure to complete the software setting. ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 6

5 Wiring Connection Model Input Type ON State Readback as 1 OFF State Readback as 0 Relay ON Relay OFF Dry Contact ZT-2053-IOG (Source) (Sink) Voltage > 3.5 V Open Collector ON Voltage < 1 V Open Collector OFF Close to GND Open Dry Contact ZT-2055-IOG (Source) (Sink) +10 ~ +50 V DC +4 V DC Max. +10 ~ +50 V DC +4 V DC Max. ZT-2060-IOG (Sink) (Source) +3.5 ~ +30 V DC OPEN or <1 V DC +3.5 ~ +30 V DC OPEN or <1 V DC ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 7

Model Output Type ON State Readback as 1 OFF State Readback as 0 ZT-2043-IOG Drive Relay Resistance Load ZT-2055-IOG Resistance Load Inductive Load ZT-2060-IOG Relay Output 6 Troubleshooting If you have any difficulties using your ZT-20xx-IOG series I/O device, please send the following contents of the problem to service@icpdas.com 1 Description of the problem 2 Architecture of application, such as model name, number and connection relationship. 3 The details of module configurations, such as the status of DIP switches, rotary switch and software configurations. ICP DAS, ZT 20xx IOG SERIES Quick Start, Version 1.0.0 Page 8