Features Regulated Converter Long 5 year warranty 2MOPP/2VAC Suitable for built in Class II applications Wide input voltage range (85-264VAC) Low leakage current (<75µA) m operation - C to +85 C operating temperature Description The is a compact 3 x 2 high effi ciency AC/DC power supply with 2xMOPP safety approval for medical applications. These space saving enclosed power supplies have an universal input voltage range (85-264VAC), 4kVAC isolation, require no minimum load and can be used at ambient temperatures of between - C and +85 C. The 5V, 12V, 15V, 24V or 48V output voltages are fully protected and have tolerances of less than ±.2% over the entire input voltage range and less than ±.5% over the entire load range. The output voltage can be trimmed over a ±1% range. The series is certifi ed to medical safety standard IEC/ES/EN-1-1 3rd Edition and with less than 75µA leakage current. It has a built-in Class B EMI fi lter and comes with a 5 year warranty. 65 Watt Enclosed & Open Frame Case Style Single Output Selection Guide Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ. Load (1) [VAC] [VDC] [A] [%] [µf] -5S (1,2) 85-264 5 1-12S (1,2) 85-264 12 5.42 92.5 45-15S (1,2) 85-264 15 4.34 93.5-24S (1,2) 85-264 24 2.71 93.5 11-48S (1,2) 85-264 48 1.36 93 235 2MOPP 2VAC Notes: Note1: Max Cap Load is tested at minimum input and full resistive load Model Numbering Output Power Output Voltage Single - S / - Connections (3) Case Style (1) E314885 CSA/CAN-C22.2 No 1-1:14 certified ANSI/AAMI ES1-1 certified EN1-1-2 CISPR11 FCC Part 15 & 18 Notes: Note2: Case Style: without suffi x, standard enclosed case add suffi x /OF for open frame style Note3: Connections: without suffi x, standard connection with connector with suffi x -ST connection with screw terminals Examples: -12S = 12Vout, standard enclosed case -48S/OF = 48Vout, open frame style -15S/OF-ST = 15Vout, open frame style with screw terminal connection www.recom-power.com REV.: 7/19 MED-1
BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Input Current 115VAC, full load 2VAC, full load 85VAC 2VAC 264VAC VDC (4) 3VDC Inrush Current cold start, 2VAC A No load Power Consumption.11W Input Frequency Range AC Input /Hz 4Hz (4) Output Voltage Trimming on-board trimpot ±1.% Minimum Load % Start-up Time Rise Time Hold up Time 115VAC, full load 16ms Operating Frequency Range Output Ripple and Noise (measured @ MHz BW) -24S Efficiency [%] Efficiency vs. Load 5VDC, 2VAC others, 2VAC 5VDC, 12VDC and 15VDC with 1µF/25V MLCC 24VDC, with 1µF/V MLCC 48VDC, with.1µf/v MLCC ms khz 1kHz 75mVp-p 75mVp-p 1mVp-p Notes: Note4: Confi rmed performance, but not covered in certifi cates. V input voltage with derating 115VAC 1 2VAC 1 Efficiency [%] Line Derating Efficiency vs. Input Voltage 1.6A.9A 1 % load % load 85 15 125 145 165 185 5 225 245 264 Input Voltage [VAC] 1s 85 15 125 145 165 185 5 225 245 264 Input Voltage [VAC] www.recom-power.com REV.: 7/19 MED-2
REGULATIONS Parameter Condition Value Set Voltage Accuracy 2VAC, full load ±1.% Line Voltage Regulation low line to high line, full load ±.2% Load Voltage Regulation % to % load 1% to % load Transient Peak Deviation load step from % - 75% change at 2.5A/µs 3.% Vout max. Transient Recovery Time load step from % - 75% change at 2.5A/µs µs typ. Deviation vs. Load Deviation [%] 1.75.5.25 -.25 -.5 -.75 115VAC 2VAC -24S 5VDC others 5VDC others -1 1.7%.5%.6%.4% PROTECTIONS Parameter Condition Value Input Fuse Short Circuit Protection (SCP) internal line neutral T3.15A / 2VAC, slow blow type T3.15A / 2VAC, slow blow type continuous, auto-recovery Over Load Protection (OLP) % of Iout rated (Hiccup) 145% typ. Over Voltage Protection (OVP) % of Vout nominal (Latch off) 125% min / 1% max. Isolation Voltage (5) tested for 1 minute I/P to O/P I/P to Case, O/P to Case 4kVAC 2.5kVAC Isolation Resistance VDC MΩ min. Insulation Grade reinforced Leakage Current 264VAC 75µA max. Means of Protection working voltage 2VAC/continuous 2MOPP Medical Device Classifi cation Internal clearance creepage Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage built-in power supply >8.mm >8.mm www.recom-power.com REV.: 7/19 MED-3
ENVIRONMENTAL Parameter Condition Value Operating Temperature Range refer to derating graph - C to +85 C Temperature Coeffi cient Operating Altitude ±.2%/K m max. Operating Humidity non-condensing 5% to 95% RH Pollution Degree Shock Vibration PD2 according to IEC68-2-27 according to IEC68-2-6 MTBF according to MIL-HDBK-217F, full load, +25 C 1494 x 1 3 hours Derating Graph (@ natural convection.1m/s) -5,12,48S(/OF) 1 115VAC 2VAC - - - -1 1 11 Ambient Temperature [ C] 75 85-15,24S(/OF) 1 115VAC 2VAC - - - -1 1 11 Ambient Temperature [ C] 75 85 SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Medical Electric Equipment, General Requirements for Safety and Essential Performance Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB Scheme) E314885 151113 CAN/CSA-C22.2 No. 1-1:14 ANSI/AAMI ES1-1:5 + A2:1 IEC1-1:5 + C2:7, 3rd Edition EN1-1:6 Information Technology Equipment - General Requirements for Safety (LVD) EN9-1:6 + A2:13 TW18-1 Information Technology Equipment - General Requirements for Safety IEC9-1:5, 2nd Edition + A2:13 EAC RU-AT.49.9571 TP TC 4/11 TP TC 4/11 RoHs2+ RoHS-11/65/EU + AM-15/863 EMC Compliance (Medical) Conditions Standard / Criterion Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests Industrial, scientifi c and medical equipment - Radio frequency disturbance characteritics - Limits and methods of measurement EN1-1-2:15 CISPR11:9 + A1:1, Class B continued on next page www.recom-power.com REV.: 7/19 MED-4
EMC Compliance (Medical) Conditions Standard / Criterion ESD Electrostatic discharge immunity test Air ±15kV; Contact ±8kV IEC-4-2:8 Radiated, radio-frequency, electromagnetic fi eld immunity test V/m (-MHz) 27V/m (385MHz) 28V/m (4MHz) IEC-4-3:6 + A2:1 Fast Transient and Burst Immunity AC Power Port: ±2kV IEC-4-4:12 Surge Immunity AC Port: L-N= ±1kV L-GND= ±2kV IEC-4-5:14 Immunity to conducted disturbances, induced by radio-frequency fi elds Vr.m.s IEC-4-6:13 Power Frequency Magnetic Field Hz, A/m IEC-4-8:9 Voltage Dips and Interruptions Limits of Voltage Fluctuations and Flicker Dips: >95%; %; Interruptions >95% IEC-4-11:4 EN-3-3:13 Limitations on the amount of electromagnetic intererence allowed from digital & electronic devices 47CFR FCC Part 15 Subpart B, Class B Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to GHz ANSI C63.4:14 FCC methods of measurement of radio noise emissions from industrial, scientifi c, and medical equipment FCC OST/MP-5 EMC Compliance (Industrial) Conditions Standard / Criterion Electromagnetic compatibility of multimedia equipment Emission Requirements Information technology equipment - Immunity characteristics - Limits and methods of measurement EN532:15+AC:13, Class B EN524:1+A1:15 ESD Electrostatic discharge immunity test Air ±15kV; Contact ±6kV IEC-4-2:8, Criteria A Radiated, radio-frequency, electromagnetic fi eld immunity test 1V/m (-MHz) V/m (-MHz) IEC-4-3:6 + A2:1, Criteria A Fast Transient and Burst Immunity AC Power Port: ±4kV IEC-4-4:12, Criteria A Surge Immunity AC Port: L-N= ±2kV L-PE= ±4kV IEC-4-5:14, Criteria A Immunity to conducted disturbances, induced by radio-frequency fi elds AC Power Port 1V, V IEC-4-6:13, Criteria A Power Frequency Magnetic Field Voltage Dips and Interruptions Damped oscillatory wave immunity test Limits of Voltage Fluctuations and Flicker Hz/Hz, A/m, A/m Dips: >95%; %; % Interruptions >95% AC Port: L-N= ±1kV L/N-G= ±2.5kV IEC-4-8:9, Criteria A IEC-4-11:4, Criteria A IEC-4-11:4, Criteria B IEC-4-18:6 + A1:1, Criteria A EN-3-3:13 DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material Dimension (LxWxH) Weight enclosed case PCB enclosed case open frame enclosed case open frame + -ST version aluminum FR4, (UL94V-) 91.4 x.5 x 33.3mm 76.2 x.8 x 26.5mm 172g 137g continued on next page www.recom-power.com REV.: 7/19 MED-5
Dimension Drawing Enclosed Case (mm) Top View 51.3 14.3 FC 41.3 76.2 FC 84.2 91.4 Side View 1. 33.3.5 logo embossed AC Input Connector () Pin# Terminal Mating Housing 1 AC/L 3 AC/N (SD-2478) (931) DC Output Connector () Pin# Terminal Mating Housing 1,2 V- 3,4 V+ (SD-2478) (941) Bottom View 1. 3.5 9.6 M3 screws continued on next page www.recom-power.com REV.: 7/19 MED-6
Dimension Drawing Open Frame (/OF) (mm) Top View 44. 76.2 Connector Version Ø3.2 51.3 14.3 FC 69.8 Screw Terminal Version -ST 51.3 14.3 DC Output Connector () Pin# Trim Terminal Adj. Mating Housing Screw Terminal Connection -ST Top View logo embossed Screw Terminal Version -ST Enclosed Version logo embossed Open Frame Version 51.3 14.3 logo embossed 2.5 FC 44.4.8 1. Side View 1.6 24. AC Input Connector () Pin# Terminal Mating Housing 1 AC/L 3 AC/N 1,2 V- 3,4 V+ (SD-2478) (SD-2478) (931) (941) Screw terminal information # Function AWG Model 1 VAC in (L) 26-16 ETB 3 VAC in (N) 26-16 (EK381V) 1,2 -Vout 26-16 ETB 3,4 +Vout 26-16 (EK381V) recommended tightening torque:.2nm www.recom-power.com REV.: 7/19 MED-7
PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) cardboard box enclosed case 1. x. x 85.mm open frame 111. x 94. x 51.mm Packaging Quantity 1pcs Storage Temperature Range - C to +85 C Storage Humidity non-condensing 5% to 95% RH The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 7/19 MED-8