SHIMADEN DIGITAL INDICATORS

Similar documents
SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATOR

SHIMADEN PROGRAM CONTROLLER

SHIMADEN DIGITAL CONTROLLER

SHIMADEN DIGITAL CONTROLLER

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

SHIMADEN PROGRAMMABLE CONTROLLER

BASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter

General Specifications

General Specifications

General Specifications

General Specifications

SHIMADEN DIGITAL CONTROLLER

PROGRAMMABLE CONTROLLER

MICRO-CONTROLLER X (48 48 mm)

General Specifications

General Specifications

PROGRAMMABLE CONTROLLER

General Specifications

General Specifications

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MICRO-CONTROLLER X (96 96 mm)

DC1010/DC1020/DC1030/DC1040

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

DIGITAL INDICATING CONTROLLER

DIGITAL PROGRAM CONTROLLER

MICRO-CONTROLLER X (48 96 mm)

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

PROCESS & TEMPERATURE CONTROLLERS

MODEL: TC10EM. Temperature Controller TC10 Series

HYBRID RECORDER OUTLINE

General Specifications

General Specifications

General Specifications

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

Process displays For standard signals, temperature, resistance measurement

APPENDIX APPENDIX A 1

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Digital indicator for panel mounting With multi-function input Model DI25

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: W2TS. Mini-MW Series

MODEL: R30US4. Remote I/O R30 Series


General Specifications

PID CONTROLLERS LT SERIES

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

SINEAX V 604s Programmable multifunctional transmitter

Process and Temperature Controllers

Models UT350/UT320 Digital Indicating Controllers

VIEW RECORDERS SPECIFICATIONS

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

CONTA-ELECTRONICS. Converter Units

MODEL: M1EXT. with Display M1E Series

Temperature Controller

Network Instrumentation Module Controller Module NX-D15/25/35

Digital Meters With A Multicolour Bargraph LEL-NA3 one-channel LEL-NA5 one-channel LEL-NA6 two-channel

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

General Specifications

General Specifications

General Specifications

P5201 Universal Programmable Transmitters with Galvanic Isolation

General Specifications

Model UP350 Program Controller

B850 Boiler House Energy Monitor

High Performance Process & Temperature Controllers

Temperature Controllers E5 J

TxBlock-USB Transmitter

Excellent low-cost Process & Temperature Controllers

MICRO-CONTROLLER X (48mm 48mm)

General Specifications

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

PROGRAM CONTROLLER OUTLINE

MICRO-CONTROLLER X mm

Fuzzy Temperature Controllers E5AF

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

Ramp/Soak Temperature Controller REX-P250

SPECIFICATIONS Digital Indicator 1. General

DigitroniK TM Digital Indicating Controller SDC20

ADAM 4000/4100 Series

Easy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible

MV110-8A. Analog input module 8 channel. User guide

General Specifications

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

CompoBus/D-type Digital Controller

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

RE92. CHECKMATE. Dual loop controller for industry purpose.

[3] MOUNTING DIRECTION

* Our controllers can be used with other brand of strain gauge sensors. Please contact RKC for more details. DO1 Control output (CH1)

USB-2404-UI Specifications

General Specifications

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

B850 Boiler House Energy Monitor

Analogue temperature controllers

DRG-SC Series Signal Conditioners

Transcription:

Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright display Make reading from long distance and low light location easier Multi-inputs & Multi-ranges User selectable Thermocouple, RTD, V, mv and Current inputs A 25Ω resistor is required across the input terminal for 4-2mA DC Inverse scaling possible With voltage and current input signals, normal and inverse scaling is possible. Additionally, normal and inverse scaling is possible for the analog output signals. Dust and splash proof front panel Equivalent to IP66 Wide range of optional features Alarms, analog output signals and communication interface (RS-232C or RS-485: MODBUS / Shimaden) available Sensor power supply 24V DC available A six-point selector switch, (the series), is available for combined use.

SPECIFICATIONS Series SD16A Display Digital display Action display Display accuracy Display accuracy range Display resolution Measured value display range Display update cycle Setting Setting Setting range Setting protection Input Type of input Thermocouple External resistance Input impedance Burnout Cold junction temperature compensation accuracy R.T.D. Amperage Lead wire tolerable resistance Voltage (mv) Voltage (V) Input impedance Current Input impedance Input scaling function Scaling range Span Position of decimal point Sampling cycle PV bias PV filter Isolation Alarm output (option) Number of alarm points Alarm type Alarm setting range Alarm action Alarm sensitivity Alarm output / rating Alarm output update cycle : Process value (PV) 7 segment Red LED 4 digits (H: 2mm) : 1 point of parameter display (SET) by green LED : 1 point of communication display (COM) by green LED : 2 points of alarm (AL1, AL2) by red LED : ±(.3% FS+1 digit) within measuring range : Excluding cold junction temperature compensation accuracy in the case of thermocouple input : ±5%FS for temperature below 4 C of thermocouple B : When the thermocouple [T, U] indication value is ~1 C,.5%FS and when it is below -1 C, 1%FS : 23 C±5 C (18~28 C) : Depends on measuring range (.1,.1,.1, 1) : -1~11% of measuring range (Accuracy guaranteed for value is within measuring range only) : For R.T.D. input of -2~6 C: 21~68 C : For thermocouple [K] input of -199.9~8 C: -273.1~9. C :.25~5. seconds configurable (.25 seconds step) When.5 second or more is set, there may occur a difference among the displayed value, the analog output and the communication data. : By four (4) front key switches : Same as measuring range : Keylock ON/OFF : Three-type multiple input of Thermocouple, R.T.D., Voltage (mv, V) : B, R, S, K, E, J, T, N, {U, L (DIN 4371)}, WRe5-26 Refer to measuring range code table : 1Ω max. : 5KΩ max. : Standard (Up-scale) : ±1 C (18~28 C range) : ±2 C (5~18 C, 28~45 C range) (±5 C to the negative side of measuring range in case of T and U input) : JIS Pt1Ω 3-wire type : Approx..25mA :5Ω max. / wire (3 lead wire should have same resistance) When the resistance value of each wire is same ~5Ω:.5 C, 5~1Ω:.2 C, 1~2Ω:.6 C, 2~3Ω: 1.4 C max. : ~1mV DC : ~5V, 1~5V, ~1V DC : 5KΩ min. : 4~2mA DC : 25Ω [A shunt resistor needs to be connected to the terminal] : Scaling possible for voltage (mv, V) or current (ma) input and inverse scaling possible. : -1999~9999 unit : 1~1 unit : 1,.1,.1,.1 :.25 seconds : -1999~2 unit : ~1 seconds ( = without filter) : Isolated between input and analog output (sensor power supply), or between input and communication. Not isolated between input and system. : 2a (AL1 and AL2) for both normal open and common : Selectable from combinations of the following 4 types : Higher limit absolute value (latching function) : Lower limit absolute value (latching function) : Within measuring range or within full scaling range : ON-OFF action : 1~999 unit Within measuring range : Contact 1a (common) / 24V, AC1.5A (resistive load) :.25 seconds

SPECIFICATIONS Series SD16A Analog output (option) / Not selectable with the sensor power supply Analog output type Output resolution Output accuracy Output scaling Output update cycle Communication (option) Communication type Communication system Communication speed Data bit length Data format Communication address Multi-drop connection Communication delay Communication protocol Communication code Others Sensor power supply (option) Output rating ON/OFF Restrictions Others Data storage Ambient conditions for use Temperature and Humidity Height Installation category Degree of pollution Power supply voltage Power consumption Applicable standard Safety EMC Dust proof/drip proof Insulation resistance Dielectric strength Case material External dimensions Mounting Panel thickness Panel cutout Weight : ~1mV DC (output resistance: 1Ω) : ~1V DC (load current: 1mA max.) : 4~2mA DC (load resistance: 3Ω max.) : Approx. 1/14 : ±(.3%FS + 1 digit) of display value : Within measuring range or input scaling range (inverse scaling possible) :.25 seconds : RS-232C, RS-485 : Half duplex start-stop synchronized system : 12, 24, 48, 96, 192 bps : 7 bit even parity 1 stop bit 8 bit non parity 1 stop bit : 7E1, 7E2, 7N1, 7N2, 8E1, 8E2, 8N1, 8N2 : 1~1 : 31 max. (with RS-485) : 1~1 milli-seconds : Shimaden standard protocol, MODBUS ASCII, MODBUS RTU : Shimaden standard protocol: ASCII MODBUS ASCII: ASCII MODBUS RTU: binary : Start character and BCC operation method can be selected for Shimaden standard protocol. : 24V±3V DC 25mA max. : Depending upon instrument's power ON-OFF status. : Sensor power supply can't be selected when the analog output is selected. Sensor power supply can't be selected when the power supply 24V is selected. : By non volatile memory (EEPROM) : -1~5 C/9%RH max. (on condition that there is no dew condition) : 2m above sea level or lower : Category II : Degree 2 : 1~24V AC±1%, 5/6Hz 24V AC (5/6Hz) /DC±1% (option) : 11VA (1~24V AC), 7VA (24V AC), 5W (24V DC) : IEC611-1, EN611-1 : EN61326:1997+A1:1998, A2:21, A3:23 EMC testing display accuracy ±3%FS : IP66 (Complies with the IEC 529-IP66) : Between input/output terminal and power supply terminal: 5V DC 2MΩ minimum : Between input/output terminal and protective conductor terminal 5V DC 2MΩ minimum : Between all input/output terminals and power terminal: 23V AC for one minute (faradic current 1mA) : Between power terminal and ground terminal: 15V AC for one minute (faradic current 1mA) : PPO resin molding (equivalent to UL94V-1) : H48 x W96 x D11 mm : Push-in panel (one-touch mount) : 1.~4. mm : H45 x W92 mm : Approx. 25g

SPECIFICATIONS Series Selector series No. of switching points No. of switching circuits Switching operation method Applicable signal contact rating Contact method Voltage Current Contact resistance Operating ambient temperature range Operating ambient humidity range Material Color External dimensions Panel cutout Mounting Panel thickness Weight :6 :2 : Push button switching : DC voltage, current (R.T.D.is not applicable) : Contact slide : 3V DC max. : 1mA DC max. : 3m Ω max. : -1~5 C : 9% RH max. : PPO resin : Case : Munsell No. N-1 or compatible Front Panel: Munsell No. N-1 or compatible : H48 x W96 x D118 (panel depth: 1) mm : H45 x W92 mm : Push-in panel (one-touch mount) : 1.~4. mm : Approx. 25g APPLICATION EXAMPLE 1. Selection of T. C. Switching 2. Selection of Voltage Switching T. C. Compensating Lead Wire Compensating Lead Wire T. C. Converter Copper Lead Wire Copper Lead Wire Indicator Voltage Indicator Recorder R. T. D. Converter Recorder 3. Selection of Analog Output (Voltage) 4. Installation Example With SD16A Control Signal Controller Analog Output SD16A Indicator SD16A Controller Analog Output Control Signal Recorder

ORDERING INFORMATION Series SD16A ITEM CODE SPECIFICATIONS 1 SERIES SD16A- Digital Indicator DIN Size 48 96 mm 4 Current (4~2mA DC) Applied via enclosed 25Ω shunt resistor *Thermocouple B, R, S, K, E, J, T, N, 2 INPUT {U, L (DIN 4371)} 8 Multi input *R.T.D. Pt1Ω / JPt1Ω *Voltage (mv, V) ~1mV DC, ~5V DC, ~1V DC, 1~5V DC 3 POWER SUPPLY 9-1~24V AC±1% (5/6Hz) 8-24V AC ±1% (5/6Hz) / 24V DC ±1% (Note:2) None 4 ALARM OUTPUT (OPTION) Individual setting, individual output 2 points (a contact) 1 Contact capacity: 25V AC 1.5A / resistive load None 3 ~1mV DC Output resistance: 1Ω 5 ANALOG OUTPUT (OPTION) 4 4~2mA DC Load resistance: 3Ω max. OR SENSOR POWER SUPPLY (Note:2) 6 ~1V DC Load resistance: 1mA max. 8 Sensor power supply 24V DC 25mA max. (Note:2) None 6 COMMUNICATION FUNCTION (OPTION) 5 RS-485 Shimaden standard protocol/modbus (RTU/ASCII) communication protocol 7 RS-232C Shimaden standard protocol/modbus (RTU/ASCII) communication protocol Without 7 REMARKS 9 With (Please consult before ordering) Notes: 1. Scaling range: -1999~9999 unit, Span: 1~1 unit 2. The sensor power supply may not be used when you select the Power Supply Code 8 (24V AC/DC). MEASURING RANGE CODES INPUT TYPE CODE RANGE ( C) RANGE ( F) B 1 ~ 18 ~ 33 R 2 ~ 17 ~ 31 S 3 ~ 17 ~ 31 K 4-199.9 ~ 8. -3 ~ 15 K 5 ~ 12 ~ 22 THERMOCOUPLE E 6 ~ 7 ~ 13 J 7 ~ 6 ~ 11 T 8-199.9 ~ 3. -3 ~ 6 N 9 ~ 13 ~ 23 1 U 1-199.9 ~ 3. -3 ~ 6 1 L 11 ~ 6 ~ 11 2 WRe5-26 12 ~ 23 42 R.T.D. Pt 31-199.9 ~ 6. -3 ~ 11 32-1. ~ 1. -15. ~ 2. JPt * 33-199.9 ~ 5. -3 ~ 1 * 34-1. ~ 1. -15. ~ 2. ~1mV 71 VOLTAGE ~ 5V 81 1~ 5V 82 CURRENT ~1V 83 4~2mA 95 Initial value:.~1. Scaling possible (Inverse scaling possible) Scaling setting range: -1999~9999 Span: 1~1 unit Factory Setting: Universal-Input K: ~12 C Current Input 4~2mA.~1. (Without unit) Thermocouple T, U: Accuracy = ±.5%FS for -1~ C ±1%FS for -1 C or less Thermocouple B: Accuracy = ±5%FS for 4 C or less Thermocouple B, R, S, K, E, J, T, N: JIS/ANSI/IEC 1 Thermocouple U, L: DIN 4371 2 Thermocouple WRe5-26: Made of Hoskins Scaling possible (Inverse scaling possible) (Note:1) Value set at K ~12 C when shipped Voltage input: Scaling possible (Inverse scaling possible) (Note:1) Scaling possible (Inverse scaling possible) within a measuring range code * Scaleover occurs at -24. C at Pt (Code 31) or JPt (Code 33). Any decimal position shown in the measuring ranges of thermocouple and R.T.D. inputs may be concealed. ORDERING INFORMATION Series ITEM CODE SPECIFICATIONS 1 SERIES - Push button six-point selector Without 2 REMARKS 9 With (Please consult before ordering)

EXTERNAL DIMENSIONS & TERMINAL ARRANGEMENT Series SD16A & SD16A External Dimensions Terminal Arrangement AL1 AL2 SET COM 96 ENT 48 11 111 1 44.6X91.6 Alarm output COM AL1 AL2 11 12 13 Communication RS-232C RS-485 SG SG SD RD Analog output 15 16 17 18 19 Sensor power supply 18 19 SD16A 11 12 13 14 15 16 17 18 19 2 Panel Cutout 1 2 3 4 5 6 7 8 9 1 92 +.8 45 +.6 6min. L 1 2 3 1~ 24 V AC 5/6 Hz Power supply N 1 2 3 24 V AC/DC Input TC RTD Voltage (V) Voltage (mv) Current (ma) 6 7 6 7 9 5 6 7 6 7 5 6 7 A B B 25Ω register attached externally 11min. (Unit :: mm) External Dimensions Terminal Arrangement 1 2 96 18 3 4 5 6 118 1 6 + - 11 12 OUTPUT + 13 14 15-16 17 18 19 2 48 44.6X91.6 1 2 3 4 5 6 7 8 9 1 + - + - + - + - 1 2 3 4 INPUT + - 5 45 +.6 Panel Cutout 11min. In case installed with SD16A Panel Cutout 92 +.8 92 +.8 (Unit : mm) 93 +1 (Unit : mm) Warning The SD16A & series is designed for the control of temperature, humidity and other physical values of general industrial equipment. (It is not to be used for any purpose which regulates the prevention of serious effects on human life or safety.) Caution If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists, proper safety measures must be made before the instrument is put into use so as to prevent the occurrence of trouble. 66SD16A&3ILC