INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-44 AC MD-44 DC

Similar documents
INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-42 AC MD-42 DC

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-34 AC LD-34 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

INSTALLATIONSANVISNING INSTALLATION MANUAL MA-44/MA-44DC OMVANDLARE RS RS-422/485 CONVERTER RS RS-422/485. Balanced Transmission

User Guide. Westermo Teleindustri AB 2004 REV.A MDW Converter RS-232 RS-422/485.

MDW-45 Converter RS RS-422/485

Universal RS232/CMOS to RS422/RS485 Converter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

FOM-5A, 6A Asynchronous Fiber Optic Modems

User Guide Westermo Teleindustri AB TR-36. Tele and leased line modem for RV rack system.

Miniature Synchronous Multipoint Modems

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

M-Bus Master MultiPort 250L Installation and User Guide

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Concept of Serial Communication

Voice-Frequency Telegraph Modem HY101-SWT

ZCS485 User s Manual. Version ZYPEX, Inc.

Lecture #3 RS232 & 485 protocols

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

MODEL: DLS. Telemetering System

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

1 What s in the shipping package?

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

M9606. FSK Modem. 5C Communications Inc.

Interface converter G kbit/sec

Intermittent Vibration 0.075

Telemetrie-Messtechnik Schnorrenberg

MULTICONT MULTICHANNEL PROCESS CONTROLLER

Power Quality and Energy Measurement PEM735

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

Absolute encoder HE-65

TD-36 TD-36. DIN-rail Tele and Leased Line modem TD DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

MGE TM Galaxy TM , 60 Hz kva

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

XIOC technology and networking modules

CP485-4 User s Manual

USER'S MANUAL. Model : K

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

User Guide. Westermo Teleindustri AB 2006 IDW ISDN Terminaladapter.

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

DATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks

Cable and Port Specifications

Select datum Page backward in. parameter list

MULTICONT OUR PROFESSION YOUR LEVEL

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

MV110-8AS. Analog input module 8 channel. User guide

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

OD Max and OD Max Transparent displacement sensors highly accurate, non-surface dependent distance measurement

Select datum Page backward in parameter list

User Guide Westermo Teleindustri AB IDW-90. ISDN Terminaladapter.

This FAQ covers Single Direction use of current loop with transmitting devices.

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

FA Wireless SS Terminals

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

Power Quality and Energy Measurement PEM575

9600 bps, Dual Modem 170 Card Private Wire Only

This FAQ covers the common questions from technicians installing these converters.

Interface converter RS-232 / RS-485 TECHNICAL GUIDE. Review date: 9 Jun 2010 TECHNOTRADE LTD

Product Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

MODEL AT-10 ANALOG TRANSMITTER

ABSOLUTE ROTARY ENCODER SSI

Power Quality and Energy Measurement PEM575

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Components Signal Conditioning For Your Computer Instruments Standard Models

Energy Management Energy Meter Type EM21 72R Retro-Fit

SIN 57 Issue 2.4 May 2018

RM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

Liquid Level Sensors. M-Series Magnetostrictive Sensors

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

KiloStream Data Sheet

PEM353. Universal measuring device

The i-7531 CAN Repeater

Transcription:

MD-44 C MD-44 DC INSTLLTISNVISNING INSTLLTI MNUL INSTLLTIS NLEITUNG Galvanic Isolation 6155-2002 Transient Protection alanced Transmission CE pproved Westermo Teleindustri 1999 REV. Omvandlare RS-22 RS-422/485 Converter RS-22 RS-422/485 RS-22 RS-422/485 Wandler www.westermo.se

1 2 4 5 6 7 8 9 Specifications MD-44 Transmission Interface 1 synchronous, full/half duplex or simplex EI RS-22-C/CCITT V.24/V.28 9-position D-sub female, DCE Interface 2 EI RS-422/RS-485/CCITT V.11 Data rate 00 bit/s 8.4 kbit/s Indicators Power, RD, DCD, CTS, RTS, TD Insulation Galvanic insulation with opto-coupler (data transmission) and transformer (supply) Insulation voltage 150 Overvoltage protection Mains: reakdown voltage 4 at 2 C Interface 2: reakdown voltage transmitter and receiver 7V Surge capacity 0.6 kw for 1ms Power supply 2 +15/ 10% 48 62Hz Fuse 100 m fast 5x20 mm Power consumption Max 22 m at 2 Temperature range 5 50 C, ambient temperature Humidity 0 95% RH, non-condensing Dimensions 55x100x128 mm (WxHxD) Weight 0.5 kg C / 0.25 kg DC Mounting On DIN-rail 5 mm Switch settings MD-44 The MD-44 can through different switch settings be adapted to a variety of running conditions. To set the switches, open the plastic case with e.g. a screw-driver. Danger! Do not open connected unit PWR TD RD RTS CTS DCD DTR DSR SG MD-44 DC V24/RS-22-C RS-422/RS-485/V11 CVERTER V24/RS-22-C CNECTI :1-4 :1-9 LINE CNECTI R+ R- T+ T- 1 2 4 5 POWER + 8 6155-2002

Selection of data rate Selection of bits 00 9 600 10 1200 11 2400 12 4 800 2/4-wire transmission 9 600 2-wire 19 200 4-wire 8 400 Termination with fail-safe * : 8-9 not used. Terminated (4-wire) 124 * The fail-safe function forces the signal state of the receiver to OFF when the connected transmitter is in tri-state (transmitter inactive). The receiver located furthest away shall be terminated. 124 124 Terminated (2-wire) No termination Supervision table when selecting data bits 7 bits 8 bits No parity Parity 1 stop bit 2 stop bits Number of bits 9 10 10 10 11 11 11 12 Factory settings 124 : 8 and 9 not used 6155-2002 9

Connections MD-44 C Line connection (5-position screw-terminal) Direction No. CCITT V.11 Description Receiver 1 (R+) Receiver 2 (R ) Transmitter (T+) Transmitter 4 (T ) 5 Shield The definations R+/R,T+/T can be various between different manufactures. Terminal connection (DCE) (RS-22-C/V.24/V.28, 9-position D-sub, female) Direction 1) Pin Screw- CCITT V.24 Description no. terminal Circuit number I 8 10 TD / Transmitted Data O 27 104 RD / Received Data I 7 6 105 RTS / Request to Send O 8 5 106 CTS / Clear to Send O 6 2107 DSR / Data Set Ready 5 9 & 1 102SG / Signal Ground O 1 4 109 DCD / Data Carrier Detect I 4 108/2DTR / Data Terminal Ready 1) I = input O = output on MD-44 Line connection 4-wire 2-wire MD-44 Twisted pairs RS-422/485 equipment MD-44 Receiver 1 2 Transmitter Transmitter Receiver Transmitter/ 4 Receiver 4 Shield 1) 5 Shield 1) 5 / / Twisted pairs / / RS-422/485 equipment Transmitter/ Receiver 1) If shielded cable is used, connect the shield only at one end to avoid ground currents. 10 6155-2002

Transmission range (interface 2) Use twisted pair cable. Max transmission range 1200 m (cable specifications 0. mm 2 and capacitance 42pF/m). The transmission range will increase if a cable with lower capacitance and larger diameter is used. Use shielded cable in heavy industrial environments. MD-44 DC Specifications Power supply 12 6V DC Power consumption Max 1.8W Insulation 100 Fuse F1 1.6 fast 5x20 mm I övrigt gäller MD-44 C specifikationerna Connections ccording to MD-44 C, except power supply Connection no. Power supply 1 Voltage 2+ Voltage Switch settings ccording to MD-44 C 6155-2002 11

Hints RS-422/485 was designed for multidrop applications. When a system is installed it should form a bus structure (see diagrams). Star shaped networks should never be created, there are other Westermo products designed to work in star net applications. To get a correct installation according to the RS-422/485 specification it s very important that the line is terminated at the correct points. The recommendation is to terminate the receiver on the master unit and the final bus slave unit. See diagrams for details of how this is done with RS-485 (2-wire) and RS-422 (4-wire). The line transmitter used in the MD-44 is activated by data received on the RS-22 interface, unlike conventional converters that rely on a control signal (e.g. RTS). If any problems do occur on set up of the MD-44, the LED s will be helpful. PWR: The unit has power. RD: Data received on the RS-422/485 interface. DCD: Follows RD in two wire operation. lways active for four wire. CTS: Follows RTS. RTS: Status of RTS from the RS-22 interface. TD: Data received on RS-22 interface. =Termination Max 1 200 metres Max 0. metre Max 2 connections =Termination Max 2 connections N.. R+/R, T+/T definitations are not standard, it can help to shift and if the unit does not work. 12 6155-2002

OWN COMMENTS 6155-2002 1

V.24/RS-22 lock diagram V.11/RS-422 RS-485 X TD TD X2 RTS CTS 7 8 DCD RTS CTS +5V us termination 4 4 DCD 1 DSR 6 +5V RD ctivity Trig +5V us termination 2 RD SG 2 5 J2 1) 6, 7 +12V +5V -12V & 1 X2 1 2 5 ' ' Shield PE Power supply F1 Insulated power supply PE J 1) +5V 1) The jumpers J2 and J is normally not mounted Westermo Teleindustri have distributors in several countries, contact us for further information. Westermo Teleindustri S-640 40 Stora Sundby, Sweden Phone +46 16 612 00 Fax +46 16 611 80 E-mail: info@westermo.se Westermo Web site: www.westermo.se Westermo Data Communications Ltd Unit 14 Talisman usiness Centre Duncan Road Park Gate, Southampton SO1 7G Phone: +44(0)1489 580 585 Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Web: www.westermo.co.uk Subsidiaries Westermo Data Communications GmbH ruchsaler Straße 18, 6875 Waghäusel Tel.: +49(0)7254-95400-0 Fax.:+49(0)7254-95400-9 E-Mail: westermo.germany@t-online.de 6155-2002 10.99 TunaTryck, Eskilstuna, Sweden