INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER
|
|
- James Jacobs
- 5 years ago
- Views:
Transcription
1 QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.COM
2 STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485 Repeater This Quick Start Guide USER-SUPPLIED COMPONENTS 10 to 48 VDC power supply; this repeater draws a maximum of 2.3 Watts. RS-232 cable; the converter is a DCE device. RS-422/485 cables. Recommended characteristics: 24 AWG twisted pair with a shunt capacitance of 16 pf per foot and 100 Ohm characteristic impedance. STEP 2 - Certifications & UL C1/D2 FCC Class A CE IEC IEEE 1613 UL CLASS 1 / DIVISION 2 WARNING INFORMATION SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY. CONVENANT À L EMPLOI DANS LES SITES DANGEREUX DE CLASSE I, DIVISION 2, GROUPES A, B, C ET D, OU DANS LES SITES NON HASARDEUX SEULEMENT. Field wiring connections must be made using 105 C minimum copper supply wires. Les connexions de câblage sur site doivent être réalisées en utilisant des câbles d alimentation en cuivre de 105 C minimum. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. ATTENTION - DANGER D EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT ENTRAÎNER UNE ADÉQUATION À LA CLASSE I, DIVISION 2. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS. ATTENTION - DANGER D EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT ENTRAÎNER UNE ADÉQUATION À LA CLASSE I, DIVISION 2.
3 STEP 3 - Front and Back Panels, DB9 Pin-out A B E D C Figure 1. Front Panel G F Figure 2. Back Panel TABLE 1. FRONT AND BACK PANELS A DB9 Female DCE port - see Section 4. B DB9 Male DTE port - see Section 4. C D Pin 3 LED Pin 7 LED Pin 2 LED Pin 8 LED Green, ON, when a TD input (Pin 3) is raised on the DCE port. Green, ON, when an RTS input (Pin 7) is raised on the DCE port. Green, ON, when an RD input (Pin 3) is raised on the DTE port. Green, ON, when a CTS input (Pin 8) is raised on the DTE port. E Power LED Red, ON when power is applied. Power Terminal F Block 2-position, removable (10 48 VDC), see Section 6. G Grounding Lug Chassis ground to earth ground, see Section 5.
4 STEP 4 - RS-232 Connections TD (Input) TD (Output) SG RD (Output) RD (Input) SG CTS (Output) RTS (Input) RTS (Output) CTS (Input) Figure 3. RS-232 Connectors Connect your RS-232 devices. A DTE device is Data Terminal Equipment ; this includes computers, PLCs, and most devices that are not used to extend communications. Think computer for DTE. A DCE device is Data Communications Equipment ; this includes devices intended to plug directly into a DTE port including modems and devices that extend communications like a modem, such as RS-422, RS-485, or fiber optic converters or radio modems. Think modem for DCE.
5 STEP 5 - Ground Connection Figure 4. Ground Connection Black Box recommends that you ground the chassis as shown in Figure 4: Connect a grounding wire from the ground lug to a good grounding source. STEP 6 - Power Connection Figure 6. Power Connections Connect the power. Power requirements: 10 to 48 VDC. This repeater draws a maximum of 1.5 Watts. The terminal block will accept 28 to 12 AWG wire.
6 STEP 7 - Loopback Test / Troubleshooting Figure 6. Connections for Loopback Testing. Black Box recommends: 1. Configure the converter for RS wire. 2. Jumper terminals A to C and B to D. 3. Connect a PC to the RS-232 port (see Section 3). Use a DB9 female to DB9 male cable to connect a PC to the DCE port. 4. On the DTE port jumper Pin 2 to 3 and Pin 7 to 8 on the female end of the cable. This loops TD to RD and CTS to RTS. 5. Using hyperterminal or a similar program, connect to the appropriate COM port. Turn off hyperterminal local echo. 6. Transmit the data. The same data that was transmitted should be returned, and the LED indicators should light per the table should light per Table 1 in Section 3.
7
8 COPYRIGHT 2018 BLACK BOX CORPORATION. ALL RIGHTS RESERVED. Documentation Number: pn8867-r2_icd201a_2318qsg
Mid-Power Expansion Unit (MxU) Quick Installation Sheet
Mid-Power Expansion Unit (MxU) Quick Installation Sheet CMA-597-AEN GENERAL INFORMATION 1. THE MxU supports the 2.5 GHz TDD band and is installed in conjunction with the mid-power remote unit (MRU) (ordered
More informationUniversal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485
4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel
More informationThis FAQ covers Single Direction use of current loop with transmitting devices.
PAGE 1 OF 5 This FAQ covers Single Direction use of current loop with transmitting devices. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has
More informationThis FAQ covers the common questions from technicians installing these converters.
PAGE 1 OF 6 This FAQ covers the common questions from technicians installing these converters. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has
More informationCONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual
5908 SCADAWave Radio Transceiver Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical
More informationSLC 500 RTD/Resistance Input Module
Installation Instructions SLC 500 RTD/Resistance Input Module (Catalog Number 1746-NR8) Inside page Important User Information... 2 For More Information... 3 Hazardous Location Considerations... 4 Environnements
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More informationPart Numbers. Fiber Driver - ST/DB25M FIBER DRIVER
January 2010 MD940A-F MD940A-M Part Numbers - ST/DB25F MD940A-F - ST/DB25M MD940A-M FIBER DRIVER CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical
More informationUniversal RS232/CMOS to RS422/RS485 Converter
TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.
More informationLCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS
USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product
More informationInterface converter G kbit/sec
converter User s Guide 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 Interface converter G.703.1 64 kbit/sec Features Maximum line attenuation
More informationADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.
User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS
More informationControlNet Modular Repeater Medium Distance Fiber Module
Installation Instructions ControlNet Modular Repeater Medium Distance Fiber Module Cat. Nos. 9904-RPFM Use this document as a guide when you install a ControlNet repeater fiber module for medium distances.
More informationMiniature Synchronous Multipoint Modems
ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours
More informationFOM-4SF Sync/Async Single Fiber Modem
ORDERING FOM-4SF/$/+ Sync/async single fiber modem $ Specify DTE interface type: V24 for V.24 interface, female connector V35 for V.35 interface, female connector X.21 for X.21 interface, female connector
More informationA50/A51/A60. June 2008 (4th Edition) All Rights Reserved
A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection
More informationFOM-5A, 6A Asynchronous Fiber Optic Modems
ORDERING FOM-5A/*/+ Asynchronous Sub-miniature Fiber Optic Modem FOM-6A/*/+/# Asynchronous Miniature Fiber Optic Modem * Specify: F for female 25-pin connector M for male 25-pin connector + Specify: ST
More informationPRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections
-01-1/ 00 by B&B Electronics. All rights reserved. Model Port-Powered RS- Fiber Optic Modem with Handshake Support Description The allows any two pieces of RS- asynchronous serial equipment to communicate
More informationUSER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters An ISO-9001 CertiÞed Company Part# 07M3PMF9 Rev. C Doc# 056020U Revised 1/23/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationTwelve Port Multi-Band Antenna
DATA SHEET Eight High Broadband ports covering PCS, AWS / AWS-3 and WCS bands (698-798 MHz, 824-896 MHz. & 1695-2360 MHz.) Four Low Band ports covering 700 MHz and 850 MHz bands Supports 8x8 MIMO in high
More informationNETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)
NETWORK INTERFACING TE NT NETWORK NT TE Interface Interface TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment) Interface
More informationM9606. FSK Modem. 5C Communications Inc.
FSK Modem Application modem is a voice-frequency telegraphy unit (VFT unit) which operates according to the principle of binary frequency shift keying. It is designed especially for Power Industrial applications.
More informationADA User manual ADA RS-232 to RS-485 / RS-422 Converter
User manual RS- to RS- / RS- Converter Copyright 001-01 CEL-MAR sp.j. 1 io_ada-100_v._en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...
More informationInterface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).
BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.
More informationWireless Communications Module Stand-Alone HE200WCM910 and SmartStack HE800WCM900 / HE-WCM900* * HE- denotes plastic case.
MAN0783-01 15 JUN 2005 PAGE 1 This datasheet also covers products starting with IC300 instead of HE800 or HE-. Additional technical information is found in the following supplements: HE200WCM910 (MAN0782)
More informationModem 1200 baud 500FSD10 EDS500 series - FSK modems
Manual Modem 1200 baud 500FSD10 EDS500 series - FSK modems Application, characteristics and technical data have to be taken from the hardware data sheet: 500FSD10 Data sheet 1KGT150982 Operation The 500FSD10
More informationUSER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationNon-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449
IC237A IC482A JUNE 1995 IC486A IC487A-F Non-Powered Interface Converters S-232 to S-530 S-422 to V.35 S-232 to S-485 S-232 to S-422/S-449 CUSTOME SUPPOT INFOMATION Order toll-free in the U.S. 24 hours,
More information5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic
Installation and Testing 5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic Models CBR-7AC CBR-7DC This manual describes the procedures for installing and testing the CBR-7 Fiber-Optic Repeaters.
More informationM-Bus Master MultiPort 250L Installation and User Guide
Installation and User Guide Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com Contents 1 Introduction 3 1.1 Design 3 2 Functionality 4 2.1 Overview
More informationTen Port Multi-Band Antenna
DATA SHEET Eight High Broadband ports simultaneously covering PCS, AWS / AWS-3 and WCS bands Eight High Broadband ports with two Low Band ports in one antenna Excellent elevation side-lobe performance
More informationAPPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT
ICS ICS ELECTRONICS division of Systems West Inc. AB- APPLICATION BULLETIN SERIAL BACKGROUNDER (Serial 0) INTRODUCTION Serial data communication is the most common means of transmitting data from one point
More informationMULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE
Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE
More informationHexPort Multi-Band Antenna
DATA SHEET Six foot (1.8 m), six port antenna with a 65 azimuth beamwidth covering 698-894 MHz and 1710-2360 MHz frequencies Four high band and two low band ports including the WCS band in a single antenna
More informationMD-45 AC MD-45 LV/HV INSTALLATION MANUAL
MD-45 AC MD-45 LV/HV INSTALLATI MANUAL 6157-2213 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission CE Approved Converter RS-232 RS-422/485 www.westermo.us
More informationHexPort Multi-Band Antenna
DATA SHEET Six foot (1.8 m), six port antenna with a 33 azimuth beamwidth covering 698-894 MHz and 1710-2360 MHz Four high band and two low band ports including the WCS band in a single antenna Sharp elevation
More informationTriBand Antenna HPA65R-KE4A DATA SHEET
DATA SHEET Four foot (1.2 m), TriBand, six port antenna with a 65 azimuth beamwidth covering 694-960 MHz and 1695-2690 MHz frequencies Four wide high band ports covering 1695-2690 MHz and two wide low
More informationConcept of Serial Communication
Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature
More informationFanuc Serial (RS232) Communications Information
Memex Automation Inc. 777 Walkers Line, Burlington, Ontario Canada L7N 2G1 Fanuc Serial (RS232) Communications Information Contents Signal Description Fanuc Serial Cable Information Timing Chart When The
More informationTriBand Twelve-Port Antenna
DATA SHEET Six foot (1.8 m) TriBand, twelve port antenna with a 65 azimuth beamwidth covering 694-960 MHz and 1695-2690 MHz frequencies Eight wide high band ports covering 1695-2690 MHz and four wide low
More informationTwelve Port Multi-Band Antenna
DATA SHEET Four foot (1.2 m) multiband, twelve port antenna with a 65 azimuth beamwidth covering 698-798 MHz, 824-896 MHz and 1695-2360 MHz frequencies Total of Eight high band ports, four high wide band
More informationMulti-Band Twelve-Port Antenna
DATA SHEET Eight foot (2.4 m) multiband, twelve port antenna with a 65 azimuth beamwidth covering 698-896 MHz and 1695-2400 MHz frequencies Eight high band ports covering 1695-2400 MHz and four low band
More informationOctoPort Multi-Band Antenna
DATA SHEET Four foot (1. m) multiband, eight port antenna with a 65 azimuth beamwidth covering 698-798, 84-896 MHz and 1695-400 MHz frequencies Four wide high band ports covering 1695-400 MHz and four
More informationInstallation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE
Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation
More informationTen Port Multi-Band Antenna
DATA SHEET Six foot (1.8 m) multiband, 10 port antenna with a 65 azimuth beamwidth covering 698-896 MHz and 1695-360 MHz frequencies Full Spectrum Compliance for WCS, AWS3 and upcoming Band 14 Operations
More informationCable and Port Specifications
APPENDIX D This appendix includes the following information: Cables and Adapters Provided, page D-1 Console Port, page D-2 COM1 Port, page D-3 MGMT 10/100 Ethernet Port, page D-5 SFP Transceiver Specifications,
More informationIntegrity Instruments
Integrity Instruments XP-A/I User Manual Integrity Instruments P.O. Box Order Phone 00-0-00 Pine River Minnesota Fax Phone -- USA Tech Phone --0 http://www.integrityusa.com XP-A ISOLATED XP-I RS- to RS-
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem
INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 0-00 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem Short Haul Modem
More informationTwelve Port Multi-Band Antenna
DATA SHEET Twelve Port Multi-Band Antenna Eight foot (2.5 m) multiband, twelve port antenna with a 45 azimuth beamwidth covering 698-960 MHz and 1695-2360 MHz frequencies Eight wide high band ports covering
More informationZCS485 User s Manual. Version ZYPEX, Inc.
ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter
More informationUltra-wideband Bi-SectorTM Array
DATA SHEET Five foot (1.4 m), four port, dual beam antenna with patented asymmetrical beam shapes optimized for LTE Two ultra-wideband 33 beams to match existing 65 patterns, covering 1710-2400 MHz One
More informationMulti-band Bi-Sector TM Array
DATA SHEET Multi-band Bi-Sector TM Array Six foot (1.8m), twelve port, dual beam antenna with patented asymmetrical beam shapes optimized for LTE Two independent 33 beams to match existing 65 patterns,
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationMDW-45 Converter RS RS-422/485
www.westermo.com MDW-45 Converter RS-232 - RS-422/485 2 6617-2203 General information Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties
More informationTBX-1329 AC/DC COUPLING TERMINAL BLOCK
INSTALLATION GUIDE TBX-1329 AC/DC COUPLING TERMINAL BLOCK Introduction This guide describes how to install and use the TBX-1329 AC/DC coupling terminal block with the SCXI-1120, SCXI-1120D, and SCXI-1121
More informationIC800SSD Hardware Manual Pub 348R5. for models. A publication of
IC800SSD Hardware Manual Pub 348R5 for models IC800SSD104S1A IC800SSD104RS1A IC800SSD107S1A IC800SSD107RS1A IC800SSD407RS1A IC800SSD216S1A IC800SSD216RS1A IC800SSD420RS1A IC800SSD228S1A IC800SSD228RS1A
More informationHybrid Bi-SectorTM Array
DATA SHEET Eight foot (2.4 m), multiband, ten port Hybrid Bi-Sector Antenna. Deploying a high performing 65 azimuth beamwidth covering 698-960 MHz and a pair of CCI s Patented Asymmetrical 33 Shaped Beams
More informationCANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en
CANHEAD Data Sheet Special features 10channel amplifier modules for installation close to measuring points Measured data transmission to communication master via field bus Base modules for individual SGs,
More informationSEL-3031 Quick-Start Guide
SEL-3031 Quick-Start Guide Introduction The SEL-3031 is a 900-MHz, license-free, spread-spectrum radio that reliably transports as many as three serial port communications channels in point-to-point or
More informationAccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1
INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,
More informationMDS SD4 Software-Controlled Digital Communications Firmware Release 1.x.x
MDS SD4 Software-Controlled Digital Communications Start-Up Guide Firmware Release 1.x.x MDS 05-4669A01, Rev. A December 2007 OPERATIONAL & SAFETY NOTICES RF Exposure Concentrated energy from a directional
More informationSasquatch User s Manual
Sasquatch User s Manual Revision 3 June 29, 2016 Table of Contents 1 Background... 1 2 Physical Connections... 1 2.1 Power... 1 2.2 Output Signal... 1 2.2.1 Dry Contact Input... 2 2.2.2 Voltage Input...
More informationUSER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter
USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)
More informationThere are many important factors when trying to achieve good, reliable communications between 2 devices.
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationHybrid Bi-SectorTM Array
DATA SHEET Eight foot (2.4m), multiband, ten port Hybrid Bi-Sector Antenna. Deploying a high performing 65 azimuth beamwidth covering 698-960 MHz and a pair of CCI s Patented Asymmetrical 33 Shaped Beams
More informationThermocouple/mV Isolated Input Module
Quick Start Thermocouple/mV Isolated Input Module Cat. No. 1746-INT4 Contents Use this document as a guide to install and wire the 1746-INT4 module. If you need more detailed information, refer to the
More informationAtrie WireSpan 600/610 MODEM User's Manual
Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER
More informationOPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module
OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871 4-Port, RS485/RS422 Serial Module This document describes how to use the National Instruments 9871 and includes specifications and pin assignments for
More informationRS-422/RS-485 Line Tester Model 485T
Not Recommended for New Installations. Please contact Technical Support for more information. RS-422/RS-485 Line Tester Model 485T Documentation Number 485T1995 This product Designed and Manufactured In
More informationAccutech BR20. DIN rail mounted base radio
Accutech BR20 DIN rail mounted base radio 1 At the heart of any Accutech wireless instrument network is the wireless base radio. The Accutech BR20 automatically communicates with deployed instrumentation
More informationDSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.
DSP4xxFP SA USER S MANUAL A01561 Rev. A This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA700425 and up. DSP4xxSA User s Manual A01561 Rev. X Proprietary Data This document
More informationATSBT-BOTTOM-FM-4G. Electrical Specifications. Product Classification. General Specifications. Mechanical Specifications. Bottom Smart Bias Tee
Electrical Specifications EU Certification Bottom Smart Bias Tee Injects AISG power and control signals onto a coaxial cable line Reduces cable and site lease costs by eliminating the need for AISG home
More informationOcean Controls KT-5221 Modbus IO Module
Ocean Controls Modbus IO Module 8 Relay Outputs 4 Opto-Isolated Inputs 2 Analog Inputs (10 bit) 1 PWM Output (10 bit) 4 Input Counters Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs,
More informationHybrid Bi-SectorTM Array
DATA SHEET Six foot (1.9 m), multiband, Ten port Hybrid Bi-Sector Antenna. Deploying a high performing 65 azimuth beamwidth covering 698-960 MHz and a pair of CCI s Patented Asymmetrical 33 Shaped Beams
More informationElectronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge
Electronics / Water analogy Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Resistor U = R * I 1 Capacitor U 1 i dt C U L di dt Inductance Turbine Flywheel Diode Transistor
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem
MA- AC MA- DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galavanic Isolation Transient Protection 0-00 Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem
More informationDigiPoints Volume 1. Student Workbook. Module 2 Modem Overview
Modem Overview Page 2.1 DigiPoints Volume 1 Module 2 Modem Overview Summary One of the potential advantages the cable telecommunications industry has is the ability to carry data signals at speeds significantly
More informationOPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module
OPERATING INSTRUCTIONS NI 9861 1-Port, Low-Speed/Fault Tolerant CAN Module These operating instructions describe how to use the National Instruments (NI) 9861 module. For information about installing,
More informationEIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA
EIA EIA-232 Information This is one of the most misunderstood areas of RS-232. DTE stands for Data Terminal Equipment, and DCE stands for Data Circuit-terminating Equipment or Data Communications Equipment.
More informationModem E1. Modem-converter E1-L. Features. Contents
Modem-converter E1-L User s Guide 1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890121234567 Modem E1 Features E1 G703/G704 channel Distance up to 1.5 km V.35/RS-530/RS-449/RS-232/X.21/
More informationSelection guide. Communication accessories. Communication accessory selection guide. Characteristics
Communication accessories Selection guide There are 2 types of Sepam communication accessories: b communication interfaces, which are essential for connecting Sepam to the communication network b converters
More informationITL Basics of Encoding and Wiring
ITL Basics of Encoding and Wiring Objectives Quick overview of wide-area communications Define the term Structured Wiring Define "analog" and "digital" data. List the common methods used to encode analog/digital
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV
MD-45 AC MD-45 LV/HV INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG MANUEL D INSTALLATI 6157-2003 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission
More informationPACSystems* RX3i and Series 90-30
May 2012 PACSystems* RX3i and Series 90-30 Series 90*-30 Analog Output Module, Current/Voltage, 8 Channel, IC693ALG392 RX3i Analog Output Module, Current/Voltage, 8 Channel, IC694ALG392 The PACSystems
More informationChapter 12: Digital Modulation and Modems
Chapter 12: Digital Modulation and Modems MULTIPLE CHOICE 1. FSK stands for: a. Full-Shift Keying c. Full-Signal Keying b. Frequency-Shift Keying d. none of the above 2. PSK stands for: a. Pulse-Signal
More information1.0 Introduction. Related Products and Documentation
Quick Start t Guide ER450 Data Radio 1.0 Introduction Welcome to the Quick Start Guide for the ER450 Data Radio. This guide provides step-by-step instructions, with simple explanations to get you up-and-running.
More information2- and 4-port Transceivers Piercing, N-type, and BNC
$0.00 June 1992 LE050 LE051 LE052 LE053 LE063 LE064 2- and 4-port Transceivers Piercing, N-type, and BNC ETHERNET / IEEE 802.3 10MBPS 4-PORT TRANSCEIVER (MAU) POWER REQUIREMENT 11V - 16V, 500mA SQE TEST
More informationContents. Warranty and Disclaimer 2
Contents Warranty and Disclaimer 2 Physical Dimensions Board Layout 3 Usage Using the PWM board 4 Setting the start address 4 Dimming LED s 5,6 Typical hookup 7 Terminator 8 Troubleshooting Ground, termination,
More informationR10-FA-01 Ruggedized Edge Filter for Xenus: User Guide
R10-FA-01 Ruggedized Edge Filter for Xenus: User Guide P/N 95-01178-000 Revision 1 January 2009 R10-FA-01 Ruggedized Edge Filter for Xenus This page for notes. TABLE OF CONTENTS About This Guide... 5 Overview
More information3-FIBMB2 Fiber Optic Interface Module Installation Sheet
Step 1: Installing the adapter card 1. Connect the ribbon cable (P/N 250222) to J2 on the adapter card (see Figure 1, items 1 and 2). Use the cable end that allows it to exit at a right angle. 3-FIM2 Fiber
More informationDS1000E, DS1000D Series Digital Oscilloscope
Quick Guide RIGOL Publication Number QGA07115-1110 May 2013 DS1000E, DS1000D Series Digital Oscilloscope DS1102E, DS1052E, DS1102D, DS1052D 2008 RIGOL Technologies, Inc. All Rights Reserved Copyright
More informationRS-232 / 20mA Interface Converter ELO E00Q. Operation manual
RS-232 / 20mA Interface Converter ELO E00Q Operation manual 2 ELOE00QZKE001 1.0 Introduction 4 1.1 Use of the converter 4 2.0 Operation principles 4 3.0 Installation 4 3.1 Converter connection to RS-232
More informationSpecifications / Installation
1 Specifications XL6/XL6M/XL6e OCS Models HE-XL105 / HE-XL1M5 / HEXT350C115 / HEXT280C115 HE-XL1E5 / HEXT351C115 12 Digital DC Inputs / 12 Digital DC Outputs 2 Analog Inputs (High Resolution) / 2 Analog
More informationXTL-FA-01 Edge Filter for Xenus: User Guide
XTL-FA-01 Edge Filter for Xenus: User Guide P/N 95-00378-000 Revision 3 June 2008 Edge Filter for Xenus: User Guide This page for notes. TABLE OF CONTENTS About This Guide... iii Overview and Scope...iii
More informationStat-4 Stat-8 Stat-24
JULY 1993 MX864A MX866A MX868A Stat-4 Stat-8 Stat-24 STAT-4 POWER MAIN 1 2 3 4 SYNC ERR OVF TEST 1 2 3 4 RESET STAT-24 STAT-8 POWER MAIN 1 2 3 4 5 6 7 8 SYNC ERR OVF TEST 1 2 3 4 5 6 7 8 TEST SYNC 23 24
More informationMAXI Remote Location Kit MRLK 900 Installation and Configuration Manual
MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual 01/18 635079 Table of Contents Introduction... 3 Materials Included... 3 Setup Overview... 4 Radio Configuration Overview:... 4 FreeWaveTool
More informationModem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.
RS-232 to Multimode Optic Modem RS232/RS422/RS485 Fiber Converter to MM optic fibers ELO E14C E17A DIN rail mounting TxD, RxD up to transferring 6km over MM fiber Communication Max. data rate 115.2 protocol
More informationContents. Warranty and Disclaimer 2 Introduction 3
Contents Warranty and Disclaimer 2 Introduction 3 Physical Dimensions Board Layout 4 Servo connections 5 Using the Serv8 Usage 6 Setting the start address 7 Setting the pulse width 8 Using the configuration
More informationOV-1000TSC OV-1000TLC/ Base-T to 1000Base-SX/LX Gigabit Ethernet Media Converter. User s Manual
OV-1000TSC OV-1000TLC/20 1000Base-T to 1000Base-SX/LX Gigabit Ethernet Media Converter User s Manual FCC Class B Certification This equipment has been tested and found to comply with the regulations for
More informationExternal RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual
External RF Driver Electrical Driver for AOTF-crystal Instruction Manual Table of Contents 1 General... 3 2 Compliance... 3 3 Labeling... 4 4 Interface... 5 4.1 Front Panel... 5 4.2 Back Panel... 6 4.2.1
More information