Features Regulated Converter Universal input VAC 3W PCB mount package <75mW No load power consumption Ultra low profile, compact size - C to +85 C Operating temperature Continuous SCP, OCP, OVP IEC/EN/UL9 & CE certified, EN532 Class B Description 3 Watt 3 Single Output EMC Class B 3Y The series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input voltage range, regulated and short-circuit -proof isolated DC outputs, low standby power consumption and - C to +85 C operating temperature range. The have a built-in Class B / FCC Part 15 EMC filter, are certified to IEC/EN/UL9-1 and are pending to IEC/EN/UL62368 and EN61558 safety standards and come with a three year warranty. wa EAR rranty Selection Guide Part Number RAC3-3.3SGB (3) RAC3-5SGB RAC3-9SGB (3) RAC3-15SGB (3) RAC3-24SGB Input Voltage Range [VAC] Output Voltage [VDC] 3.3 5 9 12 15 24 Output Current [ma] 9 3 2 1 Efficiency typ (1) [%] 72 77 78 78 Notes: Note1: Efficiency is tested at and full load at +25 C ambient Note2: Max. Cap. Load is tested at nominal input and full resisitive load Note3: Minimum order quantity pcs Max. Capacitive Load (2) [µf] 1 E196683 UL9-1 certified IEC/EN9-1 certified UL62368-1 pending IEC/EN62368-1 certified EN61558-1 certified EN61558-2-16 certified IEC9-1 CB IEC62368-1 CB Model Numbering RAC3- SGB EMC Class B nom. Output Power Single nom. Output Voltage Ordering Examples: www.recom-power.com Single Output EMC Class B REV.: 3/18 PA-1
BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range (4) Input Current Inrush Current cold start at 25 C No load Power Consumption refer to line derating graph on PA-4 85VAC 1VDC Input Frequency Range AC Input 45Hz 65Hz Minimum Load % Power Factor Start-up Time, ms 1s Hold-up time Internal Operating Frequency % load at nominal Vin 65kHz Output Ripple and Noise (5) MHz BW C to 85 C - C to C 1 1 ma 45mA.53.41 ms ms Notes: Note4: The products were submitted for safety files at AC-Input operation Note5: Measurements are made with a 12 twisted pair-wire with a.1µf and µf parallel capacitor across output (low ESR) 5VAC 4VDC A A 75mW Pi-type mvp-p mvp-p 1mVp-p 1mVp-p mvp-p 2mVp-p mvp-p mvp-p 2mVp-p 2mVp-p mvp-p mvp-p Efficiency vs. Load RAC3-5SGB Efficiency [%] 115Vin 2Vin Efficiency [%] 115Vin 2Vin www.recom-power.com REV.: 3/18 PA-2
REGULATIONS Parameter Condition Value Output Accuracy PROTECTIONS Parameter Type Value Input Fuse internal T1A slow blow type, V Short Circuit Protection (SCP) below mw long-term mode, auto recovery Over Voltage Protection (OVP) Over Voltage Category Over Current Protection (OCP) Class of Equipment 1 1 3.8V - 4.9V 5.3V - 6.8V.3V -12.2V 12.6V - 16.2V 15.75V -.3V 25.2V - 32.4V 1.41A -3.A.91A - 2.2A.49A - 1.25A.37A -.95A.29A -.72A.19A -.45A hiccup mode, auto recovery OVCII hiccup mode, auto recovery Isolation Voltage (6) I/P to O/P rated for 1 minute 3kVAC/mA Isolation Resistance Isolation Capacitance Insulation Grade ±2.5% max. Line Regulation low line to high line ±.5% max. Load Regulation % to % load ±.5% max. Accuracy vs. Load RAC3-5SGB 2.5 2.5 Deviation [%] 2 1.5 1.5 -.5-1 -1.5-2 -2.5 Class II MΩ min. pf min., pf max. reinforced Leakage Current 277VAC, Hz.1mA max. Deviation [%] 2 1.5 1.5 -.5-1 -1.5-2 -2.5 Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: For operation, an external Circuit for MOV AC/DC is recommended. Components The (RAC s) Varistor + > should comply operation with IEC651-2. eg. EPCOS S14 series Protection Circuit L N FUSE U www.recom-power.com REV.: 3/18 PA-3
ENVIRONMENTAL Parameter Condition Value Operating Temperature Range (@ natural convection.1m/s) (see graph) with derating - C to +85 C Maximum Case Temperature Temperature Coefficient Operating Altitude + C ±.3%/ C Operating Humidity non-condensing 5% - 95% RH Pollution Degree Shock Vibration MTBF according to MIL-HDBK-217F, G.B. +25 C + C m PD2 G/11ms pulse, 3 times at each x, y, z axes -1Hz, 2G min./1cycle, period min. along x,y,z axes for 6 cycles x 3 hours 17 x 3 hours Derating Graph (@ Chamber and natural convection.1m/s) - - 85 1 Ambient Temperature [ C] Line Derating Graph 85 1 135 1 185 2 235 2 285 5 Input Voltage [VAC] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety (LVD) EN9-1: 6 + A2, 13 SA13184S 1 Information Technology Equipment, General Requirements for Safety (CB) IEC9-1, 2nd Edition: 5 + AM2, 13 Information Technology Equipment, General Requirements for Safety Audio/video, information and communication technology equipment. Safety requirements Audio/video, information and communication technology equipment. Safety requirements (CB) Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 V Part 2: Particular requirements RoHs 2+ E196683-A3-UL pending 4787985921-1725-CB SA 19184L 1 UL9-1, 2nd Edition, 14 CAN/CSA C22.2 No. 9-1-7, 2nd Edition, 14 UL62368-1, 2nd Edition CAN/CSA C22.2 No 62368-1 IEC62368-1, 2nd Edition: 14 EN62368-1: 14 EN61558-1: 5 + A1, 9 EN61558-2-16: 9 + A1, 13 RoHS 11/65/EU + AM15/863 continued on next page www.recom-power.com REV.: 3/18 PA-4
EMC Compliance Condition Standard / Criterion Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Limitations on the amount of electromagnetic intererence allowed from digital and electronic devices EA13184E 1 EN532: 15, Class B EA13184F 1 47 CFR FCC Part 15 Subpart B: 16 ESD Electrostatic discharge immunity test Air ±8kV, Contact ±4kV EN-4-2: 9, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN-4-3: 6 + A2,, Criteria A Fast Transient and Burst Immunity AC Power Port ±1kV EN-4-4: 12, Criteria A Surge Immunity AC Power Port L-N ±1kV EN-4-5: 14, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 3V EN-4-6: 14, Criteria A Voltage Dips and Interruption DIMENSION AND PHYSICAL CHARACTERISTICS Voltage Dips >95% Voltage Dips % Voltage Interruptions >95% EN-4-11: 4, Criteria A EN-4-11: 4, Criteria A EN-4-11: 4, Criteria C Parameter Type Value Material Package Dimension (LxWxH) Package Weight Dimension Drawing (mm) case PCB black plastic, (UL94 V-) FR4, (UL94 V-) 37. x 24. x 15.mm g typ. 37. embossed logo. ±.1 36.7 3.26 5.8 x 2.54 = 25. 1 2 3 Bottom View 5 4 7 x 2.54 = 17.78 3.11 3.5 ±.5 15. 24. 23.5 Recommended Footprint Deltais Top View 5 4 1 2 3 2.54 2.54 restricted area for PCB layout Pin Connections Pin # Single 1 VAC in (L) 2 VAC in (N) 3 NC 4 -Vout 5 +Vout NC: not connected Tolerance: XX.X ±.5mm Pin Width: XX.X ±.5mm 5.8 www.recom-power.com REV.: 3/18 PA-5
PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 5. x 39.7 x 23.2mm Packaging Quantity pcs Storage Temperature Range - C to + C Storage Humidity non-condensing 5% - 95% RH max. The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 3/18 PA-6