TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Similar documents
C B. Models. Models 2MOPP

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Metal Case Power Supplies

Output Voltage* (nom.)(adjustable)

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

General. Environmental. EMC & Safety

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

Output Voltage nom. (adjustable)

Enclosed Power Supplies

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

CB Scheme UL508 UL ATEX II3G

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Load (2) Single or Dual

Load (2) Single or Dual

Output Voltage nom. (adjustable)

Features. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

MXD40Multi_ EH-0218 PART NUMBER STRUCTURE. Vo3 (Triple only) 9: 24V. y: refer to Suffix yy. P-DUKE Technology Co., Ltd.

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Output Full Load

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

VOF XX - XXX - X

For more information, please visit the product page. output. output current max (A)

FED30-48 S 05 - N HC Series Name Input Output Output Remote Control Assembly Option Voltage Quantity Voltage Option PART NUMBER STRUCTURE

IEC/EN/UL60950 & CE certified, EN55032 Class B

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

Pinning (3) 4:1 Input Single or Dual. Notes: Note3: /X2 is without ON/OFF CTRL and without Output Voltage Trimming

LB115S 115W Single Output

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

FED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly Option Voltage Quantity Voltage Range Option

General. Environmental. EMC & Safety

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Packaging. nom. Output Voltage

Features. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter

Encapsulated Power Supply

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Features. Switching Regulator. 0.5 Amp SIP3 Single Output R R DC/DC Converter

WAF S 12 W - N S DR Series Name Input Output Output Input Remote Control Load Share Assembly Voltage Quantity Voltage Range Option Option Option

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Notes: Note3: without suffix, standard isolation voltage (1kVDC/1 second) with suffix /H, high isolation voltage (3kVDC/1 second)

PDAM500 Series 500W Power Supply

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

Features. Regulated Converters. RS6 6 Watt. SIP8 Single and Dual Output. DC/DC Converter. Description. Selection Guide

High power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

VMS-300A - XX - XXX - X

TE W Single Output External Power Test & Measurement/Industrial Series

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

TE90 90W Single Output External Power Test & Measurement/Industrial Series

Features. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

TE40 40W Single Output External Power Test & Measurement/Industrial Series

Watts HCP Series

150 Watt Industrial (WLT)

LFWLP W 12V 15.00A 25.00A 92%

Switching Power Supply Type SPP1 60W Enclosed type

Doc. EA Model Number:

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma)

DN03S/D Series DC/DC CONVERTER 2-3W, DIP-Package

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Output Current 1.2VDC 1.5VDC 1.5VDC 1.2VDC 1.5VDC 1.5VDC 0.65VDC. Vout=3.6VDC 180µA. Vout=1.8VDC, use E-cap 330µF Vout=3.3VDC and 3.6VDC.

Transcription:

, Features High power density 40 W power supply (enclosed / open frame) 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency across full load range Protection class II prepared Operating up to 5000m altitude Adjustable output voltage 3-year product warranty C B Scheme prepared ES 60601-1 UL 60950-1 The of AC/DC power supplies feature a reinforced double I/O isolation system according to latest medical safety standards (60601-3 3rd edition, 2 x MOPP). The excellent efficiency of up to 92% allows a high power density for the standard 2.44 x 3.0 packaging format. The full load operating temperature range is 40 C to +70 C while it goes up to 85 C with 50% load derating (for single output models). They come with an active power factor correction and the EMC characteristic is dedicated for applications in industrial and domestic fields. High reliability is provided by use of industrial quality grade components and an excellent thermal management. It makes the products an ideal solution for medical devices and for demanding safety and space critical applications. Models Order code Output voltage Output current max. Efficiency enclosed, open frame, max. screw terminal pin connector Vout 1 Vout 2 Vout 3 Vout 1 Vout 2 Vout 3 TPP 40-105 TPP 40-105A-J 5 VDC (± 10 %) 8.0 A 90 % TPP 40-112 TPP 40-112A-J 12 VDC (± 10 %) 3.34 A 92 % TPP 40-115 15 VDC (± 10 %) 2.67 A 92 % TPP 40-124 TPP 40-124A-J 24 VDC (± 10 %) 1.67 A 92 % TPP 40-148A-J 48 VDC (± 10 %) 0.84 A 92 % TPP 40-221 1) +12 VDC (± 10 %) +5 VDC 3.34 A 4 A 89 % TPP 40-231 1) +15 VDC (± 10 %) +5 VDC 2.67 A 4 A 88.5 % TPP 40-251 1) +24 VDC (± 10 %) +5 VDC 1.67 A 4 A 86 % TPP 40-321M2 1) +12 VDC (± 10 %) +5 VDC 12 VDC 3.34 A 4 A 0.5 A 88 % TPP 40-331M3 1) +15 VDC (± 10 %) +5 VDC 15 VDC 2.67 A 4 A 0.5 A 88 % TPP 40-3512 1) +24 VDC (± 10 %) +5 VDC +12 VDC 1.67 A 4 A 0.5 A 86 % 1) Total power should not exceed nominal power http://www.tracopower.com Page 1 of 5

Input Specifications Input voltage range AC range (universal input) 85 264 VAC DC range 120 370 VDC Input frequency 47 63 Hz Input current at full load at 115 VAC / 230 VAC 1.05 A max. / 0.55 A max. Input protection Input inrush current at 230 VAC 60A max. Zero load power consumption Output Specifications T3.15 A/250 VAC (internal fuse in both line & neutral) 0.15 W max. (acc. ErP directive) Voltage set accuracy single output: ±1% multi output: ±1% Vout1 ±2% Vout2, Vout3 Regulation - single output Input variation 0.2% max. Load variation (0-100%) 5 VDC model: 0.7% max. other models: 0.5% max. Regulation - multi output Input variation 0.2% max. Load variation (0-100%) Vout1: 0.5% max. Vout2: 1.5% max. (0.1W to full load 0.7% max.) Vout3: 0.7% max. cross regulation (25% / 100%) 1.5% max. Minimum load Temperature coefficient not required (Vout 3 requires 0.5 W over Vout 1/Vout 2 to be stabilized) 0.02%/K Hold-up time Vin = 115 VAC 25 ms typ. Start-up time <1s Rise time Ripple and noise - single output (20Mhz Bandwidth) 20 ms typ. 5-15 VDC models: 75 mvp-p typ. with cap. 10µF/25V 1206 X7R MLCC 24 VDC models: 75 mvp-p typ. with cap. 1µF/50V 1206 X7R MLCC 48 VDC models: 150 mvp-p typ. with cap. 0.1µF/100V 1206 X7R MLCC Ripple and noise - multi output Vout 1 12 VDC model: 120 mvp-p typ. with cap. 1µF/50V 1206 X7R MLCC (20Mhz Bandwidth) 15 VDC model: 150 mvp-p typ. with cap. 1µF/50V 1206 X7R MLCC 24 VDC model: 240 mvp-p typ. with cap. 1µF/50V 1206 X7R MLCC Vout 2 all models: 100 mvp-p typ. with cap. 10µF/25V 1206 X7R MLCC Vout 3 12 VDC model: 120 mvp-p typ. with cap. 10µF/25V 1206 X7R MLCC 15 VDC model: 150 mvp-p typ. with cap. 10µF/25V 1206 X7R MLCC Overvoltage protection 125 140% of nominal Vout Overload protection by current limit single output: at 145% Iout typ. multi output: at 145% Pout1 +Pout2 Short circuit protection continuous (automatic recovery) Transiente response Peak deviation Vout1: 3% of Vout max. (25% load step change) Recovery time 600µs typ. General Specifications Operating temperature 40 C to +85 C with derating, see graph on p.3 Output power derating Temperature single output: 2.67 %/K above +70 C at 230 VAC 2.75 %/K above +65 C at 115 VAC multi output: 1.60 %/K above +60 C at 230 VAC 1.67 %/K above +55 C at 115 VAC Low input voltage 1.33 %/V below 100 VAC All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 5

General Specifications (continued) Storage temperature Humidity (non condensing) Altitude during operation Switching frequency - single output (at 230 VAC) 40 C to +85 C 5 95 % rel. H max. 5000 m 5 VDC model: 70 khz typ. (pulse frequency modulation) other models: 120 khz typ. (pulse frequency modulation) Switching frequency - multi output Vout 1 5 VDC model: 70 khz typ. (pulse frequency modulation) (at 230 VAC) other models: 115 khz typ. (pulse frequency modulation) Vout 2 750 khz typ. (pulse frequency modulation) Vout 3 510 khz typ. (pulse frequency modulation) Isolation voltage 1min (2 x MOPP insulation) Input / Output 4000 VAC Input / Case 2500 VAC Leakage current (at 264 VAC/60Hz) 75 µa max. Isolation resistance (at 500 VDC) 100 Mohm min. Reliability calculated MTBF at +25 C acc. to IEC 61709 3 010 000 h for single output models 1 716 000 h for multi output models Protection class class II prepared Electromagnetic compatibility Conducted input RI suppression EN 55022, class B (EMC), emissions Harmonic current emissions IEC / EN 61000-3-2, class A Voltage flicker IEC / EN 61000-3-3, (class tba.) Radiated input surpression EN 55011, class B Electromagnets compatibility Electrostatic discharge ESD IEC / EN 61000-4-2, 8kV/6kV perf. criteria A (EMC), immunity RF field immunity IEC / EN 61000-4-3, 20V/m perf. criteria A Electrical fast transients/burst immunity IEC / EN 61000-4-4, ± 2kV perf. criteria A Surge IEC / EN 61000-4-5, ± 1kV/± 2kV perf. criteria A Conducted RF IEC / EN 61000-4-6, 20 Vrms perf. criteria A Magnetic field (only for single output models) IEC / EN 61000-4-8, 10A/m perf. criteria A Voltage dip and interruptions according to EN 60601-1-2 30%, 500ms perf. criteria A reference: 100 VAC / 50Hz 60%, 100ms perf. criteria B > 95%, 10ms perf. criteria A > 95%, 5000ms perf. criteria B Safety standards and certification UL 60950-1, IEC/EN 60950-1, www.ul.com File e188913 (pending) IEC/EN 60601-1 3rd edition, ANSI/AAMI ES60601-1:2005(R)2012 Environment Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 55Hz, 1g, 1oct/min Shock acc. IEC 60068-2-27 3 axis, 10g half sine, 11msShock 20 G (3 directions each 3 times) Environmental compliance Reach www.tracopower.com/overview/tpp40 RoHS RoHS directive 2011/65/EU Connection screw terminal / pin connector Power Single derating output depending models: on temperature (for horizontal mounting) Power Multi derating output models: depending on temperature (for horizontal mounting) 100 80 100 80 Output Power [%] 60 40 20 115 VAC 230 VAC 0 0-25 0 20 40 60 80-25 Ambient Temperature [ C] 115 VAC 230 VAC 0 20 40 60 80 Ambient Temperature [ C] All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 5 Output Power [%] 60 40 20

Dimensions Single output: Screw Terminal Weight: 169g (5.96 oz) Input Output Pin CON 1 Pin* CON 2 1 Line 1,2 Vout 3 Neutral 3,4 + Vout *Terminal rated for 10 A max. (at higher current connection has to be split) Multi output: Screw Terminal Weight: 216g (7.80 oz) Dimensions in inch, () = mm Tolerances: x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) Wire dimensions range 26-16 AWG M3 0.5 screw locked torque MAX 5Kgf.cm/0.49N.m Terminal screw locked torque MAX 2Kgf.cm/0.2N.m Input Output Pin CON 1 Pin* CON 2 1 Line 1 Vout 3 3 Neutral 2,3 Com 4,5 Vout 2 6 Vout 1 *Terminal rated for 10 A max. (at higher current connection has to be split) Customized versions on request! Page 4 of 5

Outline Dimensions Single output: each one of the 4 srew holes can be used as a PE connection for class I applications Pin Connector Input Output Pin CON 1 Pin CON 2 1 Line 1,2 Vout 3 Neutral 3,4 + Vout CON 1: JST series mates with JST crimp terminal: BVH-21T-P1.1 and terminal housing: VHR-3N CON 2: JST series mates with JST crimp terminal: BVH-21T-P1.1 and terminal housing: VHR-4N Dimensions in inch, () = mm Tolerances: x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com Rev. April 27. 2016 www.tracopower.com Page 5 of 5