MIT480/2 Series Insulation Testers

Similar documents
MIT2500 CAT IV Insulation Testers

MIT2500 CAT IV Insulation testers

MIT480/2 Insulation testers

MIT400/2 CAT IV Insulation testers

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT400/2 CAT IV Insulation testers

MIT415 Insulation tester

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

GROUND TESTERS GROUND RESISTANCE TEST TEST EQUIPMENT DET3 CONTRACTOR SERIES WHAT S IN THE DET3T NAME? DIGITAL EARTH TESTER 3 TERMINAL

RISH Clamp POWER 1000A / 400A AC-DC. Application. Product Features. Unique Design. Non Contact Voltage Detection. Three Phase Power Measurement

PV210. Solar PV tester and I-V curve tracer

PV200. Solar PV tester and I-V curve tracer

Electronic motor protection relay

RISH CON - Hz FREQUENCY TRANSDUCER

Indicator No mark Single preset Dual preset DIN W144 H72mm DIN W48 H96mm No mark DIN W72 H72mm (4 digit) (6 digit) Counter/Timer

AME50461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY

AME28461 SERIES EMI FILTER HYBRID-HIGH RELIABILITY

Model Display digit Size Output Power supply 24VAC 50/60Hz, 24-48VDC 9999 (4-digit) 1-stage setting

Electrical test instruments

HB860H 2-phase Hybrid Servo Drive

ICM7213. One Second/One Minute Timebase Generator. Features. Description. Ordering Information. Pinout. August 1997

DET4 Series. 4-Terminal Earth/Ground Resistance and Soil Resistivity Testers. DET4 Series. Earth/Ground Resistance & Soil Resistivity Testers

NEW PRODUCT LAUNCH SALES GUIDE MIT480/2

Trms Power Multimeter

Electrical Test Instruments

Subscriber Pulse Metering (SPM) Detection

HELIARC. THE FIRST NAME IN TIG.

By: Pinank Shah. Date : 03/22/2006

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features. n n n n n n n n n n

MULTIMETER FOR POWER AND ENERGY MEASUREMENT HIGH-END DIGITAL MULTIMETER

X-Bar and S-Squared Charts

MIT400 Series Insulation and continuity testers

LIQUIDS AND GAS FLOW REGULATORS. Design Features. n n n n. Regulator Systems. Normally closed (NC) when de-energized.

Transformer testing equipment

MIT400 Series Insulation and continuity testers

Features. +Vout. +Vin. AHF28XX/CH (or Other) DC/DC Converter. Input Return. +Vout AHF28XX/CH (or Other) DC/DC Converter Output Return.

PowerLab. Electrical Power and Machines. Electrical Power & Machines. PowerLab. Features. Curriculum Coverage

Test & Measurement. Hand-held, ield and laboratory test and measurement instruments

ANALOG -DIGITAL MULTIMETER NP10 USER S MANUAL

Embedded Microcomputer Systems Lecture 9.1

Transformer testing equipment. Includes the new TRAX transformer and substation test system. Insulating. Contact timing. Cellulose insulation

Protective relay testing equipment

CareMat C DATASHEET. The pressure-sensitive mat for supervision of people with dementia and disorientation. RoHS

Methods to Reduce Arc-Flash Hazards

Mobrey MSP 2 wire 24V loop powered ultrasonic level transmitters

BMM80 Premium Insulation Multimeters

Features. +Vout. +Vin. +Vout AMF28XX (or Other) DC/DC Converter Input Return. Output Return. +Vout AMF28XX (or Other) DC/DC Converter Input Return

Technical Data Sheet. Zeta 20

Protective relay testing equipment

High Temperature Accelerometers

Insulation Testers and Earth Ground Testers

Measurement of Equivalent Input Distortion AN 20

TECHNICAL DATASHEET Incremental Encoder RI 30-O

kw (60 Hz) kva (50 Hz) ,800 Volts (60 Hz) ,000 Volts (50 Hz)

MIT510/2, MIT520/2 and MIT1020/2

KMXP SERIES Anisotropic Magneto-Resistive (AMR) Linear Position Sensors

FEATURES 4:1 single-ended multiplexer Q nominal output impedance: 7Ω (V DDO

1507/1503. Insulation Testers. Technical Data. Features and benefits:

EVB-EMC14XX User Manual

HEXFET MOSFET TECHNOLOGY

Technical Explanation for Counters

SUBJECT TO CHANGE WITHOUT NOTICE

ELEC 204 Digital Systems Design

Min. Meas. Range flow velocity = 0 to 1.64 ft/s

MINIMUM RANGE METE R* CAP ACITY MAXIMUM S IZE. in. mm gpm gpm L/min gpm L/min 1/

Indeks: WMXXCMM60 Advanced Industrial Multimeter

e n t r y A C O U S T I C

TORKEL 900-series Battery Load Unit

Tehrani N Journal of Scientific and Engineering Research, 2018, 5(7):1-7

BM25 Automated 5-kV Insulation Tester

MINIMUM RANGE METER* CAPACITY. MAXIMUM RANGE in. mm gpm gpm L/min gpm L/min SIZE 1/

HEXFET MOSFET TECHNOLOGY

32-Channel, 16-/14-Bit, Serial Input, Voltage Output DAC AD5372/AD5373

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

From the beginning of the 19th century, there was the yellow of amber. Then manufactured

NetSure 702 DC Power System. DC Power for Business-Critical Continuity

High-Impact Resistant Windows. With Storm Armor we offer protection with choices.

CR Regeneration Ovens. Keep Hot 17.01

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

TARRANT COUNTY RESOURCE CONNECTION

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

SEE 3263: ELECTRONIC SYSTEMS

Electro-Magnetic Flowmeters MINI-MAG W Vibration Limits: MAGNETIC FLOWMETER (with Integral XE Converter) Power Requirements: Power Consumption:

Hipulse UPS ( kva) 3 Phase. Digital UPS For The Digital World And Industrial Automation

Analog Digital Multimeter with Insulation Resistance Measurement

System 8000 Fiber-Optic Interfacility Links

PRACTICAL ANALOG DESIGN TECHNIQUES

Density Slicing Reference Manual

1587/1577 Insulation Multimeters

Digital insulation tester

GENERATE AND MEASURE STANDING SOUND WAVES IN KUNDT S TUBE.

MEGGER BMM2000 Series Insulation Multimeters User Guide

CR Regeneration Ovens

Design and Construction of a Three-phase Digital Energy Meter

GAMMA 20 DIGITAL MULTIMETER

Transcription:

Isulatio testig up to 500 V ad 100 GΩ rage i a hadheld istrumet 3-wire coectio for A, B ad E (Tip, Rig ad Groud) coectio (NEW) Gated access to 500 V to prevet accidetal damage (NEW) Rechargeable optios for ac ad car chargig (NEW) Sigle rage, faster cotiuity testig from 0.01 W to 1 MW (NEW) Differetial measuremet capability (NEW) Stabilized isulatio test voltage (NEW) 600 V Trms AC ad DC voltage measuremet Test result storage & Bluetooth dowloadig CATIV 600V ad IP54 DESCRIPTION The MIT480/2 series isulatio ad cotiuity testers replace the origial MIT480 rage ad are desiged specifically for the Telecommuicatios ad Cable testig markets. The ew uits feature a redesiged case, back-stad, ad 6 cell battery compartmet with separate fuse access. All istrumets are over-moulded for icreased protectio ad achieve a IP54 weatherproof ratig. THREE TERMINAL CONNECTION (NEW) Three termial measuremet permits the coectio of all three test leads for A, B ad E (or Tip, Rig ad Groud). The measuremet pair is selected from the A-B-E (T-R-G) butto o the frot pael. (New). Selectio is cofirmed i the display. No discoectio of test leads to measure idividual pairs are required. Alteratively the uits ca be used as a covetioal Two Termial istrumet.sectio of this user guide. THE MIT480/2 RANGE (FOR TELECOMMUNICATIONS, REFER TO THE MIT480 DATASHEET) The rage cosists of two istrumets: MIT481/2 50 V, 100 V, 250 V, 500 V* + Storage MIT485/2 50 V, 100 V, 250 V, 500 V* + Storage + Dowload + recharge ready * Gated access prevets accidetal selectio INSULATION RESISTANCE TESTING: The feedback cotrolled isulatio test voltage is ow accurate to +2% -0% compared to the origial +20%, providig a more accurate test voltage without the risk of over-voltage damage to circuits. A variable rage allows the exact test voltage to be selected from 10 V up to 500 V. FEATURES INCLUDE: Test voltages (New) - 50 V, 100 V, 250 V, ad 500 V. Variable test voltage (New) - Adjustable test voltage from 10 V to 500 V. 2% test voltage accuracy - The output test voltage is maitaied withi the tolerace or -0% +2% +2 V. PASS/FAIL ( / ) idicatio (New) - PASS or FAIL ( / ) displayed depedig o threshold voltage. Stabilized test voltage - The voltage is feedback cotrolled to esure it remais withi specificatio throughout the full test rage. Test voltage display (New) The actual test voltage is displayed o the smaller digital readout, with the measuremet o the larger digital display.

Test rage - Isulatio testig up to 100 GΩ * @ 500 V. Measuremet rage displayed (New) - The test rage is displayed durig selectio. Measuremet voltage display - The measuremet voltage is displayed durig the test. Aalog arc - The display also features a aalogue arc to replicate the respose of a movig coil display. Timed testig - Automatically test to a time limit. Silicoe leads - High quality flexible silicoe test leads are comfortable to use ad prevet measuremet errors o GΩ rages above 5 GΩ. Test ihibit - Prevets testig if voltages i excess of 25, 30, 50, 75 or 100 V (set by the user) are detected whe makig isulatio tests. Default is 50 V. Isulatio buzzer - The buzzer ca be set to buzz if the isulatio resistace is above a user adjustable limit, set i the Setup meu. Test Lock - Holds isulatio test o cotiuously. * Gated access prevets accidetal selectio. Test rages exted from 10 GΩ to 100 GΩ depedig o test voltage as below: 50 Volts up to 10 GΩ 100 Volts up to 20 GΩ 250 Volts up to 50 GΩ 500 Volts up to 100 GΩ CONTINUITY (RESISTANCE) TESTING Sigle resistace rage (New) - Oe rage fully automatic from 0.01 Ω to 1.0 MΩ. 200 ma or 20 ma - Either 200 ma or 20 ma cotiuity test currets are available. 20 ma test curret will cosiderably icrease battery life. Lead ull - Lead resistace compesatio (NULL) operates up to 10 Ωs of resistace. Buzzer - ON/OFF selected by simple push butto. Buzzer limit - Cotiuity buzzer limit alarm provides adjustmet of the maximum resistace the cotiuity buzzer souds. This is adjustable from 1 Ω to 200 Ω i 12 steps. Differetial measuremet (New) - Allows the differece betwee two cosecutive cotiuity tests to be measured REN (New) - Displays the appropriate REN value for the circuit uder test. Avaliable o 100 V is or cotiuity rage VOLTAGE MEASUREMENT True RMS voltage measuremet to 600 V ac or dc with resolutio from 0.1 mv. Digital voltage measuremet up to 600 V ac/dc Aalog arc measuremet to 600 V ac/dc Automatic display of frequecy durig voltage measuremet. Iput impedace is 10 MΩ to prevet loadig the circuit ad reportig low voltages. (New) CURRENT MEASUREMENT ø - 400 ma AC/DC DISPLAY The display offers a combiatio of aalog arc ad a dual digital readout: Aalog arc: Full display width aalog arc. Aalog arc display shows essetial charge ad discharge characteristics ot visible o a digital display. Sigle poiter eedle respose is similar to a movig coil meter. Setup fuctios allow cotrol of Buzzer limit alarms, Cotiuity test currets, kω/mω/gω. Dual digital display Large mai digital readout for good visibility of all mai measuremet results Secod digital display for additioal data such as: Isulatio test voltage. Isulatio leakage curret. Supply frequecy (whe measurig volts). Differetial measuremet result display OTHER FUNCTIONS AND FEATURES Weatherproof - Every tester is sealed to IP54, providig a weatherproof case to reduce the chaces of water igress, icludig the battery ad fuse compartmet. Tough housig - Rubber over mouldig combies the tough shock absorbig outer protectio with excellet grip, o a strog modified ABS housig, providig a almost idestructible case. Batteries - Battery requiremets are 6 AA batteries of either stadard Alkalie or Nickel Metal Hydride (NiMH) rechargeable type, providig a miimum of 3000 isulatio tests at 500 V. VARIABLE INSULATION VOLTAGE TESTER * The variable mode provides a uique solutio for awkward isulatio voltage measuremet applicatios. The rage optio allows a isulatio test voltage from 10 V to 500 V i 1 V steps. STORAGE AND DOWNLOADING RESULTS Revised Bluetooth ad pairig procedures have made the MIT480/2s far easier to pair ad dowload data.* The test results are dowloaded to a CSV file which ca the be opeed as a Excel spreadsheet.*

SAFETY Desiged to be exceptioally safe to use, fast detectig circuitry prevets damage to the istrumets if accidetally coected to live circuits or across phases. Specifically, all istrumets: Meet the iteratioal requiremets of IEC61010 ad EN61557. Live circuit detectio ihibits isulatio testig o circuits above 25, 30, 50, 75 or 100 V default (50 V). Live circuit detectio ad test ihibit o cotiuity measuremets. Default display of live circuit voltage o all rages. Detectio ad ihibit fuctios eve if the protectio fuse has failed. Suitable for use o CAT IV applicatios ad supply voltages to 600 V. FEATURES AND BENEFITS Desiged for the Telecommuicatios ad Cable TV markets Isulatio testig up to 500 V ad 100 GΩ rage i a had held istrumet 3 wire coectio for Tip, Rig ad Groud coectio (New) Gated access to 500 V to prevet accidetal damage (New) Adjustable isulatio test voltage from 10 V to 500 V (New)* Differetial measuremet capability (New) New case desig with optioal magetic hagig strap (New) Rechargeable optios for mais ad car chargig (New) Sigle rage, faster cotiuity testig from 0.01 Ω to 1 MΩ (New) Feedback cotrolled isulatio test voltage (New) Stabilized isulatio test voltage (New) 600 V Trms AC ad DC voltage measuremet Test result storage ad Bluetooth dowloadig* Live circuit detectio ad protectio CAT IV 600 V ad IP 54 SPECIFICATION SUMMARY TABLE INSULATION RANGES MIT481/2 MIT485/2 50 V / 100 V / 250 V / 500 V Variable 10 V to 500 V μa butto (Leakage) Lock butto o MΩ REN telephoe cout (discharge) > 500 V Gated operatio OHMS RANGES Cotiuity 0.01 Ω - 10 MΩ Isc: 200 ma R 4Ω Isc 20 ma Differece measuremet [REL] Lead ull (<10 Ω) VOLTAGE FUNCTION AC/DC Volts 600 V mv AC/DC rage TRMS Frequecy measuremet 15-400 Hz Iput impedace 10 MΩ 10 MΩ CAPACITANCE Capacitace 0.1 F - 10 μf Distace by μf (ope loop) REN calculatio OTHER FEATURES Curret measuremet ma AC/DC PASS/FAIL o limit alarms A/B/E or T/R/G switchig Number of termials 3 3 O-board memory Bluetooth ad software Recharger ready AA alkalie or NiMH Both Both CAT IV/600 V ACCESSORIES Silicoe leads (R,B,G) Switched probe supplied

SPECIFICATIONS All quoted accuracies are at +20 C Isulatio. Test voltage Nomial: MIT481/2 ad MIT485/2 50 V, 100 V, 250 V, 500 V Isulatio accuracy 50 Volts 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ 100 Volts 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ 250 Volts 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ 500 Volts 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ Service Error: BS EN 61557-2 (2007). 50V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.5% 100V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 250V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 500V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% Display rage Resolutio Short circuit/ charge curret Ope circuit voltage isulatio Test curret Leakage curret Timer cotrol NOTE Cotiuity: Cotiuity rage Aalog: 1 GΩ full scale 0.1 kω 2 ma +0% -50% to EN61557-2 (2007) -0% +2% ± 2 V 1 ma at mi. pass value of isulatio to a maximum of 2 ma max. EN61557 Operatig rage:0.10 MΩ to 1.0 GΩ 10% ±3 digits Coutdow timer 60 secod Above specificatios oly apply whe high quality silicoe leads are beig used. 0.01 Ω to 1.0 M Ω Cotiuity accuracy ± 3% ± 2 digits (0 to 100 Ω) ±5% ±2 digits (>100 Ω- 500 kω) (>500 kω - 1 MΩ uspecified) Service Error: BS EN 61557-4 (2007) - ± 2.0%, 0.1Ω - 2Ω ± 6.8% Ope circuit voltage 5 V ± 1 V Test curret 200 ma ( 0 ma +20 ma) (0.01 Ω to 4 Ω) Lead resistace Nullig up to 10 Ω Voltage: Voltage rage Volt rage accuracy Waveform Default voltmeter Frequecy: Frequecy measuremet rage Frequecy measuremet accuracy Capacitace measuremet: Capacitace rage Capacitace accuracy Cable coefficiet Uit of measure Result storage: Storage capacity Data dowload Rage Power supply Battery life AC: 10 mv to 600 V TRMS siusoidal (15 Hz to 400 Hz) DC: 10 mv to 600 V AC: ± 2% ± 2 digits DC: ± 2% ± 2 digits Service Error: BS EN 61557-1 (2007) - ± 2.0% ± 2d, 0V - 300Vac/dc ± 5.1 Uspecified rage: 0 10 mv (15 to 400 Hz) For o-siusoidal waveforms additioal specificatios apply: No-siusoidal waveforms: ±3% ± 2 digits >100 mv to 600 V TRMS ±8% ± 2 digits 10 mv to 100 mv TRMS Operates at > 25 volts ac or dc o ay rage except OFF 15 Hz - 400 Hz ± 0.5% ± 1 digit 0.1 F to 10 μf ± 5.0% ± 2 digits ( 1 F-10 μf) 40F/ km to 70F / km 50F/ km >1000 test results Bluetooth wireless Bluetooth Class II Up to 10 m (33 ft) 6 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkalie 6 x 1.2 V NiMH rechargeable cells may be used. 3000 isulatio tests with duty cycle of 5 sec ON /55 sec OFF @ 500 V ito 500 kω Charger (Optioal): 12-15 V dc (accessory iterface)

Dimesios 9.00 i x 4.25 i x 2.32 i (2.28 mm x 108 mm x 63 mm) Weight 1.76 lb (800 g) Weight (istrumet 3.86 lb (1.75 kg) ad case) Fuse Use oly 2 x 500 ma (FF) 1000 V 32 x 6 mm ceramic fuse of high breakig capacity HBC 30 ka miimum. Glass fuses MUST NOT be fitted. Safety protectio The istrumets meet EN 61010-1 (1995) to 600V phase to earth, Category IV. Refer to safety warigs supplied. EMC I accordace with IEC61326 icludig amedmet No. 1. Temperature coefficiet <0,1% per C up to 1 GΩ <0,1% per C per GΩ above 1 GΩ Evirometal Operatig temperature 14 F to 131 F (-10 C to +55 C) Humidity 90% RH at 40 C Storage temperature -13 F to +158 F (-25 C to +70 C) Calibratio temperature -8 F (+20 C) Maximum altitude 6560 ft (2000 m) IP ratig IP54 The Bluetooth word, mark ad logos are registered trademarks owed by Bluetooth SIG, Ic. ad is used uder licese.

Descriptio MIT481/2-3 termial 50 V to 500 V + storage ad recall 1006-752 MIT485/2 - as MIT481/2 + Bluetooth dowload 1006-758 Icluded accessories Red/Black 1 kv silicoe test leads with probes ad clips 1007-780 SP5 Switched probe 1007-757 Owers Iformatio CD dowload at www.megger.com Batteries 6 x AA Alkalie 1002-753 Hard carry case 2006-649 Dowload maager software dowload at www.megger.com ORDERING INFORMATION Order Code Descriptio Order Code Optioal accessories Replacemet Red/Black 1 kv silicoe test leads with probes ad clips 1007-780 AC charger kit (MIT485/2 oly) 1007-464 12 V DC battery charger (requires AC charger kit) 1004-183 SP5 Switched probe 1007-157 Test lead set ad crocodile clips 1002-001 2 wire 500 ma fused test lead set 1002-015 Batteries (6 x NiMH) 1002-753 SALES OFFICE Megger 2621 Va Bure Aveue Norristow, PA 19403 USA T 610 676 8500 E VFCustomerSupport@megger.com _DS_US_V01 www.megger.com ISO 9001 The word Megger is a registered trademark